Features
- Performance Specified for Fast IPM Applications over Industrial Temperature Range: -40°C to 100°C
- Wide Operating VCC Range: 4.5 to 20 Volts
- Typical Propagation Delays 150 ns
- Maximum Pulse Width Distortion PWD = 250 ns
- Propagation Delay Difference Min. –100 ns, Max. 250 ns
- 30 kV/µs Minimum Common Mode Transient Immunity at VCM = 1000 V
- Hysteresis
- Totem Pole Output (No Pull-up Resistor Required)
- Safety Approval: UL 1577, 3750 Vrms / 1 minute CSA File CA88324, Notice #5 IEC/EN/DIN EN 60747-5-2, VIORM = 630 Vpeak
Applications
- IPM Interface Isolation
- Isolated IGBT/MOSFET Gate Drive
- AC and Brushless DC Servo Motor Drives
- Low Power Inverters
- General Digital Isolation Note: The connection of a 0.1 µF bypass capacitor between pins 5 & 8 is recommended. ACPL-4800 High CMR Intelligent Power Module and Gate Drive Interface Optocoupler Data Sheet Schematic IF SHIELD V F V CC V O GND ICC IO Lead (Pb) Free RoHS 6 fully compliant RoHS 6 fully compliant options available; -xxxE denotes a lead-free product CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to prevent damage and /or degradation which may be induced by ESD.
1.080 ± 0.320 (0.043 ± 0.013) 2.54 ± 0.25 (0.100 ± 0.010) 0.51 (0.020) MIN. 0.65 (0.025) MAX. 4.70 (0.185) MAX. 2.92 (0.115) MIN. 5˚ TYP. 0.254 + 0.076 - 0.051 (0.010 + 0.003) - 0.002) 7.62 ± 0.25 (0.300 ± 0.010) 6.35 ± 0.25 (0.250 ± 0.010) 9.65 ± 0.25 (0.380 ± 0.010) A XXXXZ YYWW DATE CODE DIMENSIONS IN MILLIMETERS AND (INCHES). 5678 4321 OPTION CODE* UL RECOGNITION UR TYPE NUMBER * MARKING CODE LETTER FOR OPTION NUMBERS "V" = OPTION 060 OPTION NUMBERS 300 AND 500 NOT MARKED. 3.56 ± 0.13 (0.140 ± 0.005)
Ordering Information
ACPL-4800 is UL Recognized with 3750 Vrms for 1 minute per UL1577 and is approved under CSA Component Acceptance Notice #5, File CA 88324. Part number Option Package Surface Mount Gull Wing Tape& Reel IEC/EN/DIN EN 60747-5-2 Quantity RoHS Compliant ACPL-4800 -000E 300mil DIP-8 50 per tube -300E X X 50 per tube -500E X X X 1000 per reel -060E X 50 per tube -360E X X X 50 per tube -560E X X X X 1000 per reel To order, choose a part number from the part number column and combine with the desired option from the option column to form an order entry. Example 1: ACPL-4800-560E to order product of 300mil DIP Gull Wing Surface Mount package in Tape and Reel packaging with IEC/EN/DIN EN 60747-5-2 Safety Approval in RoHS compliant. Example 2: ACPL-4800-000E to order product of 300mil DIP package in tube packaging and RoHS compliant. Option datasheets are available. Contact your Avago sales representative or authorized distributor for information.
0.635 ± 0.25 (0.025 ± 0.010) 12˚ NOM. 9.65 ± 0.25 (0.380 ± 0.010) 0.635 ± 0.130 (0.025 ± 0.005) 7.62 ± 0.25 (0.300 ± 0.010) 5678 4321 9.65 ± 0.25 (0.380 ± 0.010) 6.350 ± 0.25 (0.250 ± 0.010) 1.016 (0.040) 1.27 (0.050) 10.9 (0.430) 2.0 (0.080) LAND PATTERN RECOMMENDATION 1.080 ± 0.320 (0.043 ± 0.013) 3.56 ± 0.13 (0.140 ± 0.005) 1.780 (0.070) MAX.1.19 (0.047) MAX. 2.54 (0.100) BSC DIMENSIONS IN MILLIMETERS (INCHES). LEAD COPLANARITY = 0.10 mm (0.004 INCHES). NOTE: FLOATING LEAD PROTRUSION IS 0.25 mm (10 mils) MAX. 0.254 + 0.076 - 0.051 (0.010 + 0.003) - 0.002)
Solder Reflow Temperature Profile (Gull Wing Surface Mount Option 300 Parts) Note: Non-halide flux should be used TIME (SECONDS) TEMPERATURE (˚C) 200 100 50 150100 200 250 300 SEC. 50 SEC. SEC. 160˚C 140˚C 150˚C PEAK TEMP. 245˚C PEAK TEMP. 240¡C PEAK TEMP. 230˚C SOLDERING TIME 200˚C PREHEATING TIME 150˚C, 90 + 30 SEC. 2.5˚C ± 0.5˚C/SEC. 3˚C + 1˚C/-0.5˚C TIGHT TYPICAL LOOSEROOM TEMPERATURE PREHEATING RATE 3˚C + 1˚C/-0.5˚C/SEC. REFLOW HEATING RATE 2.5˚C ± 0.5˚C/SEC. Recommended Pb-Free IR Profile 217˚C RAMP-DOWN 6˚C/SEC. MAX. RAMP-UP 3˚C/SEC. MAX. 150 - 200 ˚C 260 +0/-5˚C t 25˚C to PEAK 60 to 150 SEC. 20-40 SEC. TIME WITHIN 5˚C of ACTUAL PEAK TEMPERATUREtp ts PREHEAT 60 to 180 SEC. tL TL Tsmax Tsmin Tp TIME (SECONDS) TEMPERATURE (˚C) NOTES: THE TIME FROM 25 C to PEAK TEMPERATURE = 8 MINUTES MAX. Tsmax = 200˚C, Tsmin = 150˚C Note: Non-halide flux should be used
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics (Option 060) Description Symbol Characteristic Unit Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤ 300 Vrms I-IV for rated mains voltage ≤ 450 Vrms I-III Climatic Classification 55/85/21 Pollution Degree (DIN VDE 0110/1.89) 2 Maximum Working Insulation Voltage VIORM 630 Vpeak Input to Output Test Voltage, Method b* VIORM x 1.875=VPR,100% Production Test with tm=1 sec, Partial discharge < 5 pC VPR 1181 Vpeak Input to Output Test Voltage, Method a* VIORM x 1.5=VPR, Type and Sample Test, tm=60 sec, Partial discharge < 5 pC VPR 945 Vpeak Highest Allowable Over-voltage(Transient Over-voltage tini = 10 sec) VIOTM 6000 Vpeak Safety-limiting values - maximum values allowed in the event of a failure. Case Temperature TS 175 °C Input Current IS, INPUT 230 mA Output Power (refer to Thermal Derating Curve) PS, OUT- PUT 600 mW Insulation Resistance at TS, VIO = 500 V RS >109 W * Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles. Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application. Insulation and Safety Related Specifications Parameter Symbol 8-Pin DIP Unit Conditions Minimum External Air Gap(External Clearance) L(101) 7.1 mm Measured from input terminals to output terminals, shortest distance through air. Minimum External Track- ing (External Creepage) L(102) 7.4 mm Measured from input terminals to output terminals, shortest distance path along body. Minimum Internal Plastic Gap (Internal Clearance)
0.08 Through insulation distance, conductor to conductor,
usually the direct distance between the photo emitter and photo detector inside the optocoupler cavity. Minimum Internal Tracking (Internal Creepage) NA mm Measured from input terminals to output terminals, along internal cavity. Tracking Resistance (Comparative Tracking Index) CTI 200 mm DIN IEC 112/VDE 0303 Part 1 Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1) Option 300 - surface mount classification is Class A in accordance with CECC 00802.
Parameter Symbol Min. Max. Units Note Storage Temperature TS -55 125 °C Operating Temperature TA -40 100 °C Average Forward Input Current IF(AVG) 10 mA Peak Transient Input Current IF(TRAN) ( ≤ 1 µs Pulse Width, 300 pps) 1.0 A ( ≤ 200 µs Pulse Width, < 1% Duty Cycle) 40 mA Reverse Input Voltage VR 5 V Average Output Current IO 25 mA Supply Voltage VCC 0 25 V Output Voltage VO -0.5 25 V Total Package Power Dissipation PT 210 mW 1 Lead Solder Temperature (Through Hole Parts Only) 260 °C for 10 sec., 1.6 mm below seating plane Solder Reflow Temperature Profile (Surface Mount Parts Only) See Package Outline Drawings section Parameter Symbol Min. Max. Units Power Supply Voltage VCC 4.5 20 V Forward Input Current (ON) IF(ON) 6 10 mA Forward Input Voltage (OFF) VF(OFF) - 0.8 V Operating Temperature TA -40 100 C OUTPUT POWER - PS , INPUT CURRENT - IS TA - CASE TEMPERATURE - oC 20050 400 12525 75 100 150 600 800 200 100 300 500 700 175 P S (mW) IS (mA) Recommended Operating Conditions Thermal Derating Curve
-40°C ≤ TA ≤ 100°C, 4.5V ≤ VCC ≤ 20V, 6mA ≤ IF(ON) ≤ 10 mA, 0V ≤ VF(OFF) ≤ 0.8 V, unless otherwise specified. All Typicals at TA = 25°C. Logic Low Output Voltage VOL 0.5 V IOL = 6.4 mA 1, 3 Logic High Output Voltage VOH 2.4 VCC - 1.1V V IOH = -2.6 mA 2, 3, 72.7 IOH = -0.4 mA Output Leakage Current(VOUT = VCC+0.5V) IOHH 100 µA Vcc = 5 V IF = 10mA
500 Vcc = 20 V
ICCL 1.9 3.0 mA Vcc = 5.5 V VF = 0 V IO = Open2.0 3.0 Vcc = 20 V Logic High Supply Current ICCH 1.5 2.5 mA Vcc = 5.5 V IF = 10 mA IO = Open1.6 2.5 Vcc = 20 V Logic Low Short Circuit Output Current IOSL 25 mA VO = Vcc = 5.5 V VF=0V 2
50 VO = Vcc = 20 V
IOSH -25 mA VCC = 5.5 V IF=6mA VO=GND -50 VCC = 20 V Input Forward Voltage VF 1.5 1.7 V TA = 25 C IF=6mA 4 1.85 Input Reverse Breakdown Voltage BVR 5 V IR = 10 µA Input Diode Temperature Coefficient DVF DTA -1.7 mV/ IF = 6 mA Input Capacitance CIN 60 pF f = 1 MHz, VF = 0 V 3
Switching Specifications (AC) -40°C ≤ TA ≤ 100°C, 4.5V ≤ VCC ≤ 20V, 6mA ≤ IF(ON) ≤ 10 mA, 0V ≤ VF(OFF) ≤ 0.8V. All Typicals at TA = 25°C, IF(ON) = 6 mA unless otherwise specified. Propagation Delay Time to Logic Low Output Leve tPHL 150 350 ns With Peaking Capacitor 5,6 5 Propagation Delay Time to Logic High Output Level tPLH 110 350 ns With Peaking Capacitor 5,6 5 Pulse Width Distortion PWD 250 ns | tPHL - tPLH | 8 Propagation Delay Dif- ference Between Any 2 Parts PDD -100 250 ns 10 Output Rise Time (10- 90%) tr 16 ns 5,8 Output Fall Time (90- 10%) tf 20 ns 5,8 Logic High Common Mode Transient Immu- nity |CMH| -30000 V/µs |VCM| = 1000 V, IF = 6.0 mA, VCC = 5 V, TA = 25 C 9 6 Logic Low Common Mode Transient Immu- nity |CML| 30000 V/µs |VCM| = 1000 V, VF = 0 V, VCC = 5 V, TA = 25 C 9 6 Package Characteristics * The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your equipment level safety specification or Avago Application Note 1074 entitled “Optocoupler Input-Output Endurance Voltage, ” publication number 5963-2203E. Notes: 1. Derate total package power dissipation, PT, linearly above 70°C free-air temperature at a rate of 4.5 mW/°C. 2. Duration of output short circuit time should not exceed 10 ms. 3. Input capacitance is measured between pin 2 and pin 3. 4. Device considered a two-terminal device: pins 1, 2, 3, and 4 shorted together and pins 5, 6, 7, and 8 shorted together. 5. The tPLH propagation delay is measured from the 50% point on the leading edge of the input pulse to the 1.3 V point on the leading edge of the output pulse. The tPHL propagation delay is measured from the 50% point on the trailing edge of the input pulse to the 1.3 V point on the trailing edge of the output pulse. 6. CMH is the maximum slew rate of the common mode voltage that can be sustained with the output voltage in the logic high state, VO > 2.0 V. CML is the maximum slew rate of the common mode voltage that can be sustained with the output voltage in the logic low state, VO < 0.8 V. 7. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 4500 V rms for one second (leakage detec- tion current limit, II-O ≤ 5 µA). This test is performed before the 100% production test for partial discharge (Method b) shown in the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table, if applicable. 8. Pulse Width Distortion (PWD) is defined as |tPHL - tPLH | for any given device. 9. Use of a 0.1 µF bypass capacitor connected between pins 5 and 8 is recommended. 10. The difference between tPLH and tPHL between any two devices under the same test condition. Input-Output Momentary Withstand Voltage* VISO 3750 Vrms RH < 50%, t = 1 min.TA = 25°C 4,7 Input-Output Resistance RI-O 1012 W VI-O = 500 Vdc 4 Input-Output Capacitance CI-O 0.6 pF f = 1 MHz, VI-O = 0 Vdc 4