ACMD-6207_15 AVAGO | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 15
Technical content
Features
- Miniature Size - 1.6 x 2.0 mm size - 0.9 mm height - Standard 1.6 x 2.0 mm PCB footprint
- Balanced Rx Port, 100 Ω
- No external matching required
- High Isolation
- High Power Rating - +31 dBm Abs Max Tx Power
- Environmental - RoHS Compliant - Halogen free - TBBPA Free Specifications
- Rx Band Performance, 2620-2690 MHz, – 20 to +85°C - Insertion Loss: 3.0 dB Max - Rx Noise Blocking: 50 dB Min
- Tx Band Performance, 2500-2570 MHz, – 20 to +85°C - Insertion Loss: 3.0 dB Max - Tx Interferer Blocking: 55 dB Min
Applications
Handsets or data terminals operating in the Band 25 fre - quency range. Ant Port 3 (Pin 4) Tx Port 1 (Pin 1) Rx (Balanced) Port 2 (Pins 6, 7)
– 20°C +25°C +85°C Min Max Min Typ [3] Max Min Max Antenna Port to Receive Port ZRx Impedance of Balanced Rx Port, Real Part Ohms 100 S23 Insertion Loss in Receive Band 2620 – 2690 MHz dB 3.0 1.8 3.0 3.0 DS23 Amplitude Imbalance in Receive Band 2620 – 2690 MHz dB ±1.8 ±0.6 ±1.8 ±1.8 DS23Ø Phase Imbalance in Receive Band 2620 – 2690 MHz deg ±8 ±5.1 ±8 ±8 S23 Attenuation in Transmit Band 2500 – 2570 MHz dB 45 45 63 45 S23 Attenuation, 50 – 2380 MHz dB 40 40 63 40 S23 Attenuation, 2380 – 2450 MHz (Wi-Fi Low) dB 40 40 55 40 S23 Attenuation, 2450 – 2484 MHz (Wi-Fi High) dB 35 35 62 35 S23 Attenuation, 2775 – 8500 MHz dB 18 18 48 18 S22 Return Loss (SWR) of Rx Port in Rx Band (100 W), 2620 – 2690 MHz dB 9 (2.1) 9 20 (1.2) (2.1) 9 (2.1) S33 Return Loss (SWR) of Ant Port in Rx Band 2620 – 2690 MHz dB 9 (2.1) 9 19 (1.3) (2.1) 9 (2.1) Transmit Port to Antenna Port S31 Insertion Loss in Transmit Band 2500 – 2510 MHz 2510 – 2570 MHz dB 3.0 2.4 2.1 1.4 3.0 2.4 3.0 2.4 S31 Attenuation in Receive Band 2620 – 2690 MHz dB 45 45 60 45 S31 Attenuation, 50 – 1565 MHz dB 45 45 61 45 S31 Attenuation 1565 – 1574 MHz (GPS Low Band) dB 45 45 48 45 S31 Attenuation, 1574 – 1577 MHz (GPS L1 Band) dB 45 45 48 45 S31 Attenuation, 1577 – 1585 MHz (Wideband GPS High) dB 45 45 48 45 S31 Attenuation, 1597 – 1607 MHz (GLONASS) dB 45 45 47 45 S31 Attenuation, 1607 – 1680 MHz dB 40 40 47 40 S31 Attenuation, 1805 – 1880 MHz (Band 3 Rx) dB 40 40 47 40 S31 Attenuation, 2110 – 2170 MHz (Band 1 Rx) dB 40 40 56 40 S31 Attenuation, 2402.5 – 2461.5 MHz (Wi-Fi Bands 1 – 9) dB 40 40 48 40 S31 Attenuation, 2447.5 – 2481.5 MHz (Wi-Fi Bands 10 – 13) dB 35 35 46 35 S31 Attenuation in Tx 2nd Harmonic Band 5000 – 5140 MHz dB 35 35 47 35 S31 Attenuation, 5150 – 5850 MHz dB 20 20 42 20 S31 Attenuation, 7500 – 7710 MHz dB 25 25 27 25 S11 Return Loss (SWR) of Tx Port in Tx Band 2500 – 2570 MHz dB 10 (1.9) 10 20 (1.2) (1.9) 10 (1.9) S33 Return Loss (SWR) of Ant Port in Tx Band 2500 – 2570 MHz dB 10 (1.9) 10 20 (1.2) (1.9) 10 (1.9) Isolation Transmit Port to Receive Port S21 Tx-Rx Isolation in Receive Band 2620 – 2690 MHz dB 50 50 60 50 S21 Tx-Rx Differential Isolation in Transmit Band, 2500 –
2570 MHz
S21 Tx-Rx Common Mode Isolation in Transmit Band, 2500 – 2570 MHz dB 55 55 60 55 Notes: 1. T C is the case temperature and is defined as the temperature of the underside of the Duplexer where it makes contact with the circuit board. 2. Min/Max specifications are guaranteed at the indicated temperature with the input power to the Tx port equal to or less than +27 dBm over all Tx frequencies unless otherwise noted. 3. Typical data is the average value of the parameter over the indicated band at the specified temperature. Typical values may vary over time. 4. Integrated Insertion Loss over any 1.25 MHz channel within the band.
Absolute Maximum Ratings [1] Parameter Unit Value Storage temperature °C –65 to +125 Maximum RF Input Power to Tx Port dBm +31 Maximum Recommended Operating Conditions [2] Parameter Unit Value Operating temperature, Tc [3] , Tx Power ≤ 29 dBm, CW °C –40 to +100 Operating temperature, Tc [3] , Tx Power ≤ 30 dBm, CW °C –40 to +85 Notes: 1. Operation in excess of any one of these conditions may result in permanent damage to the device. 2. The device will function over the recommended range without degradation in reliability or permanent change in performance, but is not guaranteed to meet electrical specifications. 3. T C is defined as case temperature, the temperature of the underside of the duplexer where it makes contact with the circuit board.
Figure 23. Package Outline Drawing Figure 25. Product Marking and Pin Orientation Figure 24. Pad Detail
0.15 X 45°
- Dimensions in millimeters
- Tolerance, unless otherwise noted:
- Dimensions nominal unless otherwise noted
- Contact areas are gold plated
4 Ant
6 Rx-B
7 Rx-A
Figure 29. PCB Detail, Metal Dimensions. (line width and spacing) can be adjusted to retain a Zo of 50 ohms.
0.100 X 45° (X2)
Figure 31. PCB Detail, Dimensions for Asymmetrical Via Pattern.
- All vias Ø 0.25 mm, /f_illed
Figure 30. PCB Detail, Dimensions for Symmetrical Via Pattern.
0.310 PITCH
- Via pattern symmetrical about
- All vias Ø 0.25 mm, /f_illed
Figure 34. SMT Reel Drawing
- Reel shall be labeled with the following
- A certi/f_icate of compliance (c of c) shall
- Reel must not be made with or contain
- All dimensions in millimeters (mm)
Figure 35. Verified SMT Solder Profile
6 February 2003
Ordering Information
Part Number No. of Devices Container ACMD-6207-BLK 100 Tape Strip or Anti-static Bag ACMD-6207-TR1 3000 178 mm (7-inch) Reel
For product information and a complete list of distributors, please go to our web site: www.avagotech.com Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies in the United States and other countries. Data subject to change. Copyright © 2005-2013 Avago Technologies. All rights reserved. AV02-4282EN - September 2, 2013 Appendix A – Package Marking Cross Reference Marking “W” Work Week Marking “W” (cont) Work Week (cont) 1 1 S 27 2 2 T 28 3 3 U 29 4 4 V 30 5 5 W 31 6 6 X 32 7 7 Y 33 8 8 Z 34 9 9 a 35 A 10 b 36 B 11 c 37 C 12 d 38 D 13 e 39 E 14 f 40 F 15 g 41 G 16 m 42 H 17 n 43 J 18 q 44 K 19 r 45 L 20 t 46 M 21 < 47 N 22 > 48 O 23 / 49 P 24 \\ 50 Q 25 ( 51 R 26 ) 52