Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nuclear systems. ACI-3000 Inrush current limiting accessory GENERAL FEATURES: Suitable for the series: ODS-1500 ODS-3000 ODX-3000 Active polarity reversal protection According to EN-50155 According to EN-45545 Model Nominal Input Voltage Input voltage range Inrush current Typical serial resistance Remote ON/OFF input Impedance ACI-3000-9333 24 Vdc 16.8 … 30 V < 10 A 0.4 mΩ 9.5 kΩ ACI-3000-9334 36 Vdc 25.2 … 45 V < 9 A 0.24 mΩ 15 kΩ ACI-3000-9335 48 Vdc 33.6 … 60 V < 9 A 1 mΩ 20 kΩ ACI-3000-9336 72 Vdc 50.4 … 90 V TBD TBD TBD ACI-3000-9337 110 Vdc 77 … 138 V < 7 A 10 mΩ 66 kΩ

www.premiumpsu.com Powering Your Challenge INPUT Input voltage range -30, +25 % Vin nom, transients according to EN50155 Maximum input ripple 5% Vin nom (Vrms, 100 Hz) ENVIRONMENTAL Storage temperature -40 … 80 °C Operating temperature: Full load -40 … 55 °C (EN50155 OT2) 62.5 % load -40 … 70 °C (EN50155 OT4) 25 % load -40 … 85 °C (EN50155 OT6) Relative humidity 5 … 95 % Maximum altitude 2500m at full load Cooling Natural convection Shock and vibration According to EN61373:2010 + Corr 1:2011 Category 1 class B body mounted MTBF (MIL-HDBK-217-E; Gb, 25 °C) 1M h EMC Immunity according EN61000-6-2, EN50121-3-2 Emissions according EN61000-6-4, EN50121-3-2 SAFETY Dielectric strength: Input-Inverter-Inhibit / Earth (frame) (1) 2500 Vrms / 50 Hz / 1 min Dielectric strength: Input-Inverter-Inhibit / ON/OFF (1) 1500 Vrms / 50 Hz / 1 min Dielectric strength: Earth (frame) / ON/OFF (1) 2500 Vrms / 50 Hz / 1 min Safety according to EN60950-1, EN62368-1 Fire and smoke according to EN45545-2 MECHANICAL Weight < 260 g Shock and Vibrations according to EN61373:2010 + Corr 1:2011 Category 1 Class B PROTECTIONS Against input reverse polarity Active CONTROL Remote ON/OFF input Optocoupled Maximum rating = Input voltage range Impedance: see Model table ON: Applying a voltage within input voltage range OFF: Open circuit or < 3V Note 1 See blocks diagram in next page

www.premiumpsu.com Powering Your Challenge ACI-3000 Block diagram

DESCRIPTION

The ACI -3000 is an accessory for the following Premium series: ODS-1500, ODS-3000 and ODX-3000. This device provides the following features: 1. It reduces the inrush current to the values indicated in the table. 2. It provides active protection against reverse polarity, so that the DC/AC inverter does not receive voltage or overcurrent when the voltage is reversed at the input of the ACI-3000 accessory. 3. The inverter remote ON/OFF input is in the ACI-3000. INSTALLATION 1. WARNING: Use only inverters with option remote OFF reversed. This option can be ordered including “I” letter at the end of the part number: ODS-1500-71__-_I ODS-3000-71__-_I ODX-3000-74__-_I Otherwise, the inverter will remain OFF 2. Remove the protective cover of the input inverter terminals. 3. For an easier assembly, we recommend r eplacing the input terminals screws of the inverter with the included Allen type ones, leaving them lose. 4. Insert terminals J3 and J4 on the input terminals of the inverter. See figure-1. 5. Mount the ACI-3000 brackets to the mounting surface with the screws lose. 6. Tighten the Allen screws from J3 and J4 terminals. 7. Tighten the bracket screws. 8. Place the inhibit cable included. See figure-2. J1 - Input Terminals M6 (Rec. torque 6 Nm) J2 + Input J3 - Inverter Terminals M6 (Rec. torque 6 Nm) J4 + Inverter J9 - 1 To +Inhibit inverter Cables 0.25 … 1.5 mm2 J9 - 2 To - Inhibit inverter J8 - 1 - Remote ON/OFF Cables 0.25 … 1.5 mm2 Wago 734-262 Includes female: 734-202/037-000 J8 - 2 + Remote ON/OFF Earth bolt M5 (Rec. torque 3.8 Nm) + Inverter Input Inverter + Remote ON/OFF Inverter - Remote ON/OFF - Inverter Input + Input + ON/OFF - ON/OFF - Input

www.premiumpsu.com Powering Your Challenge Figure-1 Figure-2 Example for ODX-3000 series

www.premiumpsu.com Powering Your Challenge ACI-3000 + ODS-1500 ACI-3000 + ODS-3000 ACI-3000 + ODX-3000

www.premiumpsu.com Powering Your Challenge EU, UKCA DECLARATION OF CONFORMITY The undersigned, representing the following: Manufacturer: PREMIUM, S. A., Address: C/ Dolors Aleu 19-21, 08908 L’Hospitalet de Llobregat, SPAIN herewith declares that the product: Type: DC/DC converter Models: ACI-3000-9333 … 9337 is in conformity with the provisions of the following EU directive(s): 2014/35/EU SI 2016 No 1101 Low voltage / The electrical equipment (safety) regulations 2014/30/EU SI 2016 No 1091 EMC / Electromagnetic compatibility regulations 2011/65/EU Annex II and its amendment 2015/863/EU SI 2012 No. 3032 RoHS / Restriction of the use of certain hazardous substances in electrical and electronic equipment and that standards and/or technical specifications referenced below have been applied: EN 60950-1: 2005 Safety. Information technology equipment EN 62368-1: 2014 Safety. Audio/video information and communication technology equipment IEC 61000-6-4: 2018 Generic emission standard IEC 61000-6-2: 2019 Generic immunity standard EN 50155: 2017* Railway applications. Electronic equipment used on rolling stock material EN 50121-3-2: 2016* Railway applications. EMC Rolling stock equipment * Optional, See annexe CE marking year: 2016; UKCA marking year: 2021 Notes: For the fulfilment of this declaration the product must be used only for the aim that has been conceived, considering the limitations established in the instructions manual or datasheet. L’Hospitalet de Llobregat, 31-05-2021 PREMIUM S.A. is an ISO9001and ISO14001 certified company by Bureau Veritas Miguel Angel Fernandez Chief Research & Development Officer

www.premiumpsu.com Powering Your Challenge ANNEXE Applicable values for the different sections of the norm EN50155: 2017

4.3.1 Working altitude Up to 2500 m

4.3.2 Ambient temperature

Class OT2 (-40 to 55 °C): load < 100 % Class OT4 (-40 to 70 °C): load <62.5 % Class OT6 (-40 to 85 °C): load <25 %

4.3.3 Switch-on extended

operating temp. ST1

4.3.4 Rapid temperature

4.3.5 Shocks and vibrations According EN61373:2010 + Corr 1:2011 Category 1 class B

4.3.6 EMC Electromagnetic Compatibility EN50121-3-2:2016 Test Norm Port Frequency Limits Radiated emissions IEC55016 Case

30 MHz…230 MHz 40 dB(µV/m) Qpk at 10 m

230 MHz…1 GHz 47 dB(µV/m) Qpk at 10 m

1…3 GHz Do not apply Internal freq. < 108 MHz 3…6 GHz Conducted emissions IEC55016 Input 150 kHz…500 kHz 99 dB(µV) Qpk 500 kHz…30 MHz 93 dB(µV) Qpk Test Norm Port Severity Conditions P Electrostatic discharge IEC61000-4-2 Case ±8 kV Air (isolated parts) B ±8 kV Contact (conductive parts) Radiated high-frequency IEC61000-4-3 X/Y/Z Axis 20 V/m 0.08…1.0 GHz M. 80% 1 kHz A 10 V/m 1.4…2.1 GHz M. 80% 1 kHz 5 V/m 2.1…2.5 GHz M. 80% 1 kHz 3 V/m 5.1…6 Ghz M. 80% 1 kHz Fast transients IEC61000-4-4 Input ±2 kV Tr/Th: 5/50 ns A Output ±2 kV Signal ±2 kV PE ±1 kV Surge IEC61000-4-5 Input L to L ±1 kV Tr/Th: 1.2/50 µs B Input L to PE ±2 kV Conducted RF IEC61000-4-6 Input 10 V Signal 10 V PE 10 V Magnetic field IEC61000-4-8 X/Y/Z Axis 300 A/m 0 Hz, 16.7 Hz, 50/60 Hz A P= Performance criteria, L= Line, PE= Protective Earth

4.3.7 Relative humidity Up to 95%

5.1.1.3 Temporary DC power

From 0.60 to 1.40 Un 0.1 s From 1.25 to 1.40 Un 1 s without damage

5.1.1.4 Interruptions of voltage

supply Class S1 (without interruptions)

5.1.1.6 Input ripple factor 10 % peak to peak with a DC Ripple Factor of 5 %

5.1.3 Supply change-over 0.6 Un duration 100 ms (without interruptions). Performance criterion A

7.2.7 Input reverse polarity

protection Yes, active protection

10.7 Protective coating for PCB

13.3 Tests list

1 Visual Inspection

2 Performance test

3 Power supply test

4 Insulation test

5 Low temperature storage test

6 Low temperature start-up test

7 Dry heat test

8 Cyclic damp heat test

9 Salt mist test

10 Enclosure protection test (IP code)

11 EMC test

12 Shocks and vibrations test

13 Equipment stress screening test

14 Rapid Temperature variation test

Routine: 24 h at 40 °C and load 100 %