Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nuclear systems. Premium Vision Standard gateway module GENERAL FEATURES: Specifically designed as a standard gateway. From 12 to 36 Vdc supply. Protocols:

  • 2xEthernet
  • CAN
  • RS232
  • RS485
  • USB

3 LEDs

4 Relay Outputs

4 Digital Inputs

4 Analog Inputs

Wide operating temperature range.

www.premiumpsu.com Powering Your Challenge BLOCKS

DESCRIPTION

The main functionality of the gateway is to provide multiple communication protocols to equipment that have communication limited to a single protocol or do not have Ethernet access. The equipment must be able to connect to multiple devices and provide information from all of them. The gateway module has two ethernets, one on RJ45 and the other on M12, it also has a RS-485 protocol on RJ11, a RS -232 protocol on DB -9, a CAN protocol on a 3-pin connector and a USB 2.0 protocol on Type A connector. PoE has been implemented over the RJ-45 Ethernet to provide input power to the device. Check the user’s manual to know more about all the features of the gateway. INTERFACE Communication Ethernet RJ-45 Connector Ethernet M12 Connector RS-232 DB-9 Connector RS485 RJ-11 Connector CAN 3 pins Connector USB 2.0 Type A Relays 8 Pin Connector Digital configuration inputs 8 Pin Connector Analog Inputs 8 Pin Connector LEDs Power ON Internal faults ENVIRONMENTAL Storage temperature -40ºC … 85ºC Operating temperature range -40ºC … 70ºC, 85ºC 10 min (EN50125-1 OT3 Class ST1 and ST2) Maximum Relative humidity 5…100% Installation altitude up to 2000 m EMC Emission according to EN50121-3-2 (Rolling stock.Apparatus) Immunity according to EN50121-3-2 (Rolling stock.Apparatus) SAFETY Safety according to EN50124-1 Railway app. MECHANICAL Approximate weight <0.5kg Protection degree IP21 Dimensions (Width x Height x Depth) Look at ‘Mechanical Drawing’ section

www.premiumpsu.com Powering Your Challenge INSTALLATION The gateway module has been designed to be installed on wall or on DIN rail . It should be done by certified personnel. For equipment connection, please refer to the user’s manual. CONNECTIONS J6 2 PINS Supply J6:1 GND J6:2 VIN J3 3 PINS CAN J3:1 GND_CAN J3:2 CANL J3:3 CANH J4 3 PINS CAN J4:1 GND_CAN J4:2 CANL J4:3 CANH J2 (X6) RJ45 Ethernet J2:1 TD+ J2:2 CTT J2:3 TD- J2:4 RD+ J2:5 CTR J2:6 RD- J2:7 - J2:8 GND/SHIELD J1 (X7) M12 Ethernet J1:1 TX_P J1:2 RX_P J1:3 TX_N J1:4 RX_N J1:5 EARTH J15 DB-9 RS-232 J15:1 NC J15:2 TX J15:3 RX J15:4 NC J15:5 GND_RS232 J15:6 NC J15:7 NC J15:8 NC J15:9 NC

www.premiumpsu.com Powering Your Challenge J7 8 PINS Relays Outputs J7:1 COM_OUT4 J7:2 OUT4 J7:3 COM_OUT3 J7:4 OUT3 J7:5 COM_OUT2 J7:6 OUT2 J7:7 COM_OUT1 J7:8 OUT1 J8 8 PINS Digital Inputs J8:1 IN4-P J8:2 IN4-N J8:3 IN3-P J8:4 IN3-N J8:5 IN2-P J8:6 IN2-N J8:7 IN1-P J8:8 IN1-N J9 8 PINS Analog Inputs J8:1 AN4-P J8:2 AN4-N J8:3 AN3-P J8:4 AN3-N J8:5 AN2-P J8:6 AN2-N J8:7 AN1-P J8:8 AN1-N J14 RJ11 RS-485 J14:1 GND_RS485 J14:2 RS485_B J14:3 RS485_A J14:4 RS485_B J14:5 RS485_A J14:6 GND_RS485

www.premiumpsu.com Powering Your Challenge MECHANICAL DRAWING General dimensions (mm)

www.premiumpsu.com Powering Your Challenge VISUAL INDICATIONS Frontal view Alarms LED ON Power ON The device is switched on Internal Fault Has internal faults or failures

www.premiumpsu.com Powering Your Challenge EU, UKCA DECLARATION OF CONFORMITY The undersigned, representing the following: Manufacturer: PREMIUM, S. A., Address: C/ Dolors Aleu 19-21, 08908 L’Hospitalet de Llobregat, SPAIN herewith declares that the product: Type: Premium Vision Model: ACG-3000 is in conformity with the provisions of the following EU directives and UK legislation: 2014/35/EU SI 2016 No 1101 Low voltage / The electrical equipment (safety) regulations 2014/30/EU SI 2016 No 1091 EMC / Electromagnetic compatibility regulations 2015/863/EU SI 2012 No. 3032 RoHS / Restriction of the use of certain hazardous substances in electrical and electronic equipment and that standards and/or technical specifications referenced below have been applied: EN 62368-1: 2020 Safety. Audio/video information and communication technology equipment EN 61000-6-4: 2019 Generic emission standard EN 61000-6-2: 2019 Generic immunity standard EN 50155: 2021* Railway applications. Electronic equipment used on rolling stock material EN 50121-3-2: 2016* IEC 62236-3-2: 2018* Railway applications. EMC Rolling stock equipment EN 50121-4: 2016* IEC 62236-4: 2018* Railway applications. EMC of the signalling and telecommunications apparatus CE marking year: 2025; UKCA marking year: 2025 Notes: For the fulfillment of this declaration the product must be used only for the aim that has been conceived, considering the limitations established in the instructions manual or datasheet. L’Hospitalet de Llobregat, 11-04-2025 Albert Sole Technical Director PREMIUM S.A. is an ISO9001and ISO14001 certified company by Bureau Veritas