Features
Low rDS(on) trench technology Low thermal impedance Fast switching speed
Applications
White LED boost converters Automotive Systems Industrial DC/DC Conversion Circuits Absolute Maximum Ratings Parameter Symbol Limit Units Drain-Source Voltage VDS 100 V Gate-Source Voltage VGS ±20 V Continuous Drain Current a TA=25℃ ID 51 A Pulsed Drain Current b IDM 240 A Continuous Source Current (Diode Conduction) a IS 90 A Power Dissipation a TA=25℃ PD 300 W Operating temperature / storage temperature TJ/TSTG -55~150 ℃ THERMAL RESISTANCE RATINGS Parameter Symbol Maximum Units Maximum Junction-to-Ambient a t <= 10 sec RθJA 62.5 °C/W Steady State 1 Notes a. Surface Mounted on 1” x 1” FR4 Board. b. Pulse width limited by maximum junction temperature PRODUCT SUMMARY VDS (V) rDS(on) (mΩ) ID(A) 100 78 @ VGS = 10V 51a 96 @ VGS = 5.5V
VER 1.1 2 Packaging Type TO-220
Ordering information
ZM:TO-220 Pb - free Halogen - free
VER 1.1 3
Electrical Characteristics
TA=25℃, unless otherwise specified. Parameter Symbol Test Conditions Min Typ Max Unit Static Gate-Source Threshold Voltage VGS(th) VDS = VGS, ID = 250 uA 1 V Gate-Body Leakage IGSS VDS= 0 V, VGS= ±20 V ±100 nA Zero Gate Voltage Drain Current IDSS VDS = 80 V, VGS = 0 V 1 uA VDS = 80 V, VGS = 0 V, TJ = 55° C 25 On-State Drain Current ID(on) VDS = 5 V, VGS = 10 V 100 A Drain-Source On-Resistance rDS(on) VGS = 10 V, ID = 20 A 78 mΩ VGS = 5.5 V, ID = 18 A 92 Forward Transconductance gfs VDS = 15 V, ID = 20 A 25 S Diode Forward Voltage VSD IS= 20 A, VGS = 0 V 0.93 V Dynamic T otal Gate Charge Qg VDS= 50 V, VGS = 5.5 V, ID= 20 A nC Gate-Source Charge Qgs 4.3 Gate-Drain Charge Qgd 8.2 Turn-On Delay Time td(on) VDS= 50 V, RL= 2.5 Ω, ID = 20 A, VGEN= 10 V, RGEN= 6 Ω ns Rise Time tr 9 Turn-Off Delay Time td(off) 20 Fall Time tf 11 Input Capacitance Ciss VDS = 15 V, VGS = 0 V, f = 1 MHz 822 pF Output Capacitance Coss 83 Reverse Transfer Capacitance Crss 72 Note : a. Pulse test: PW <= 300us duty cycle <= 2%. b. Guaranteed by design, not subject to production testing
VER 1.1 4 Typical Performance Characteristics
VER 1.1 5
VER 1.1 6 Packing Information TO-220
VER 1.1 7 Notes ACE does not assume any responsibility for use as critical components in life support devices or systems without the express written approval of the president and general counsel of ACE Electronics Co., LTD. As sued herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain l ife, and shoes failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. ACE T echnology Co., LTD. http://www.ace-ele.com/