Features

Repetitive Peak Off◆ -State Voltage: 800Vand1000V R.M.S On◆ -State Current ( IT(RMS)= 12A ) ◆Very high immunity to false turn-on by dV/dt ◆Triggering in three quadrants only Pin compatible with standard triacs◆ Safe clamping capability for low energy o◆ ver-voltage transients ◆ These Devices are Pb-Free and are RoHS Compliant Absolute Maximum Ratings Scan the QR code to view the latest product information ADV 2.T2 1.T1 3.Gate TO-220 1 2 3

2 / 6 www.advsemi.com Feb,2013 -Rev.3.02 ADV Electrical Characteristics ( Tj = 25°C unless otherwise specified ) Symbol Items Conditions AACT1208/10 Unit S Blank IDRM IRRM Peak Forward Reverse Blocking Current VDRM = VRRM, Tj = 25°C Max. 5 uA VDRM = VRRM, Tj = 125°C 1 mA VTM Peak On-State Voltage I TM = 17A, tp = 380 μs Max. 1.65 V VGD Q1-Q2-Q3 Non−Trigger Gate Voltage VD = 2/3VDRM RL = 3.3 kΩ Tj = 125°C 0.2 0.2 V VGT Q1-Q2-Q3 Gate Trigger Voltage VD = 12V ,RL = 33Ω Max. 1.5 V IGT Q1-Q2-Q3 Gate Trigger Current Max. 10 35 mA IH Q1-Q2-Q3 Holding Current I T = 0.1A Max. 15 45 mA IL Q1-Q3 Latching Current I G = 1.2 IGT Max. 20 50 mA Q2 30 70 dV/dt Critical Rate of Rise of Off-State Voltage VD = 2/3VDRM gate open Tj = 125°C Min. 1000 1500 V/ μs Rth(j-c) Junction to case (AC) Max. 1.4 ° C/W Rth(j-a) Junction to ambient Max. 60 ° C/W FIG.1:Quadrant are defined and the gate trigger test circuit V A VD RGV A VD RGV A VD RG V A VD RG RL T2+ T2- Q1(T2+G+) Q3(T2-G-) Q2(T2+G-) RL RL G+G-

3 / 6 www.advsemi.com Feb,2013 -Rev.3.02 ADV FIG.3: Typical RMS on-state current VS Allowable case Temperature FIG.4: Maximum transient thermal impedance FIG.2: Maximum on-state power dissipation FIG.5: Rated surge on-state current ( Non-Repetitive) FIG.6: Gate trigger current VS Junction temperature R.M.S On-State Current (A) Power Dissipation(W) R.M.S On-State Current (A) Power Dissipation(W) 0 2 4 6 8 10 12 14 16 18 20 360° Full Cycle 0 3 6 9 12 15 R.M.S On-state Current(A) 150 120

0 Tc(°C),Case Temperature

360° Full Cycle 0 50 100 150 200 250 IGT(Tj)/IGT(25°C) x 100(%) 150 125 100 -50 -25 Tj(°C),Junction Temperature 0.1 1 10 Rth(j-c)(°C/W),Transient Thermal Impedance 101 102 103 104 105 tp(ms),Conduction Time 0 20 40 60 80 100 120 140 160 ITSM(A),Surge On-State Current 102 Number Of Cycles f=50Hz f=60Hzf=60Hzf=60Hzf=60Hz Tj=25°C Max

4 / 6 www.advsemi.com Feb,2013 -Rev.3.02 ADV FIG.7:Holding current and Latching current VS Junction temperature FIG.8: Gate trigger voltage VS Junction tem perature FIG.9: On-state characteristics(Max) 0 50 100 150 200 250 150 125 100 -50 -25 Tj(°C),Junction Temperature 0 50 100 150 200 250 150 125 100 -50 -25 Tj(°C),Junction Temperature IH,IL(Tj)/IH,IL(25°C) x 100(%) 0 50 100 150 200 250 150 125 100 -50 -25 Tj(°C),Junction Temperature 0 50 100 150 200 250 150 125 100 -50 -25 Tj(°C),Junction Temperature 0 50 100 150 200 250 150 125 100 -50 -25 Tj(°C),Junction Temperature 0 50 100 150 200 250 150 125 100 -50 -25 Tj(°C),Junction Temperature VGT(Tj)/VGT(25°C) x 100(%) ITM(A),On-State Current 10-1 100 101 1010 3.5 2.5 1.5

0.5 VTM(V),On-State Voltage

(1) (2) (1)Tj=25°C Max (2)Tj=125°C Max

5 / 6 www.advsemi.com Feb,2013 -Rev.3.02 ADV PACKAGE MECHANICAL DATA Making Diagram

Ordering information

Part number Package Marking Packing Quantity AACT1208# TO-220 AACT1208# Tube 50pcs AACT1210# TO-220 AACT1210# Tube 50pcs Note:# = Gate Trigger Current Sensitivity and type Symbol Dimensions In Millimeters Dimensions In Inches Min Max Min Max A 4.40 4.60 0.173 0.181 B 9.00 9.30 0.354 0.366 C 0.40 0.60 0.015 0.023 c1 2.00 2.60 0.078 0.102 c2 1.23 1.32 0.048 0.051 D 0.70 1.00 0.027 0.039 E 10.00 10.40 0.393 0.409 g 2.40 2.70 0.094 0.106 G 6.20 6.80 0.244 0.267 I 2.65 2.95 0.104 0.116 L 15.80 16.80 0.622 0.661 L1 3.75 0.147 L2 1.14 1.70 0.044 0.066 L3 1.14 1.70 0.044 0.066 Ф 3.60 3.90 0.141 0.153 K 2.60TYP 0.102TYP E IL g A B CD G K φ ADV AACT1210S XXXX XXXH XX ADV:Logo X:Internal control code H:Halogen Free ADV:Logo AACT1210S:Part number X:Internal control code H:Halogen Free A AC T 12 10 # S ADVANCED Package explain: Blank=TO-220 S = 10mA Blank =35mA Sensitivity and type Voltage: 08 = 800V 10=1000V T=Triac Current:12 = 12A AC Switches

6 / 6 www.advsemi.com Feb,2013 -Rev.3.02 ADV Notice 1. All information included in this document such as product data, diagrams, charts, programs, algorithms, and application circuit examples, is current as of the date this document is issued. Such informati on, however, is subject to change without any prior notice. Befor e purchasing or using any ADV products listed in this document, please confirm the latest product in formation with a ADV sales office. Also, please pay regular and careful attention to additional and different informat ion to be disclosed by ADV such as that disclosed through our website. (http://www.advsemi.com ) 2. ADV has used reasonable care in compiling the information incl uded in this document, but ADV assumes no liability whatsoever for any damages incurred as a result of errors or omissions in the information included in this document. 3. You should use the products described herein within the range specified by ADV, especially with respectvto the maximum rating, operating supply voltage range, movement power voltage range, heat radiati on characteristics, installati on and other product characterist ics. ADV shall have no liability for malfunctions or damages arising out of the use of ADV products beyond such specified ranges. 4. When using or otherwise relying on the information in this doc ument, you should evaluate the information in light of the total system before deciding about the applicability of such information to the in tended application.ADV makes no representations, warranties or gu aranties regarding the suitability of its products for any particular applic ation and specifically disclaims any liability arising out o f the application and use of the information in this document or ADV products. 5. Although ADV endeavors to improve the quality and reliability of its products, IC products have specific characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use conditions. Please be sure to implement safety measures to guard against the possibility of physical injury, and injury or damage caused by fire in the event of the failure of a ADV product, such as safety design for hardware and software including but not limited to redundancy, fire control and malfunction prevention, appropriate treatment for aging degradation or any other applicable measures. Among others, since the evaluation of microcomputer software alone is very difficult, please evaluate the safety of the final products or system manufactured by you. 6. This document is provided for reference pur poses only so that ADV customers may select the appropriate ADV products for their use. ADV neither makes warranties or representations with respect to the accuracy or completeness of the information contained in th is document nor grants any license to any intellectual property rights or any other rights of ADV or any third party with respect to the information in this document. 7. ADV shall have no liability for damages or infringement of any intellectual property or other rights arising out of the use of any information in this document, including, but not limited to, product data, diagrams, charts,programs, algorithms, and application circuit examples. 8. This document may not be reproduced or duplicated, in any form, in whole or in part, without prior written approval from ADV.