Key Features:  2W Output Power  8,000 VDC Isolation  2 µA Leakage Current Max  Compact DIP Case  Single & Dual Outputs  Meets EN55022 Class A  600 kH MTBF  Industry Standard Pin-Out A200RHI Very High Isolation, 2W Single & Dual Output DC/DC Con vert ers Series Input Parameter Conditions Min. Typ. Max. Units Input Voltage Range 5 VDC Input 4.5 5.0 5.5 VDC12 VDC Input 10.8 12.0 13.2 24 VDC Input 21.6 24.0 26.4 Input Filter /H9266 (Pi) Filter (Complies with EN55022 Class A) Reverse Polarity Input Current 0.5 A Short Circuit Input Power 2,000 mW Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±2.0 ±4.0 % Output Voltage Balance Dual Output , Balanced Loads ±2.0 ±4.0 % Line Regulation Vin = Min to Max ±0.3 ±0.5 % Load Regulation Iout = 10% to 100% ±0.5 ±1.0 % Ripple & Noise (20 MHz) See Note 1 30 50 mV P - P Ripple & Noise (20 MHz) Over Line, Load & Temp. 100 mV P - P Ripple & Noise (20 MHz) 5 mV rms Output Power Protection 120 % Transient Recovery Time, See Note 2 50% Load Step Change 50 µSec Transient Response Deviation ±6.0 % Temperature Coeffi cient ±0.01 ±0.02 %/ºC Output Short Circuit Continuous General Parameter Conditions Min. Typ. Max. Units Isolation Voltage, Rated 60 Seconds 6,000 VDC Isolation Test Voltage Flash Tested For 1 Second 8,000 VDC Leakage Current 240 VAC, 60 Hz 2 µA Isolation Resistance 500 VDC 10 G/H9024 Isolation Capacitance 100 kHz, 1V 20 30 pF Switching Frequency 25 80 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -25 +60 ºC Operating Temperature Range Case +90 ºC Storage Temperature Range -40 +125 ºC Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Material Non-Conductive Black Plastic (UL94-V0) Weight 0.42 Oz (12g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25ºC, Gnd Benign 600 kHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 5 VDC Input -0.7 7.5 VDC12 VDC Input -0.7 15.0 24 VDC Input -0.7 30.0 Lead Temperature 1.5 mm From Case For 10 Sec 260 ºC Internal Power Dissipation All Models 2,000 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.

Effi ciency (%, Typ) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Refl ected Ripple Current (mA, Typ) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load A201RHI 5 4.5 - 5.5 645 100 15 5.0 400 0.0 62 1,000 A202RHI 5 4.5 - 5.5 629 100 15 12.0 165 0.0 63 1,000 A203RHI 5 4.5 - 5.5 623 100 15 15.0 133 0.0 64 1,000 A204RHI 5 4.5 - 5.5 476 100 15 ±5.0 ±100 ±0.0 42 1,000 A205RHI 5 4.5 - 5.5 699 100 15 ±12.0 ±83 ±0.0 57 1,000 A206RHI 5 4.5 - 5.5 695 100 15 ±15.0 ±66 ±0.0 57 1,000 A211RHI 12 10.8 - 13.2 269 50 8 5.0 400 0.0 62 500 A212RHI 12 10.8 - 13.2 262 50 8 12.0 165 0.0 63 500 A213RHI 12 10.8 - 13.2 260 50 8 15.0 133 0.0 64 500 A214RHI 12 10.8 - 13.2 185 50 8 ±5.0 ±100 ±0.0 45 500 A215RHI 12 10.8 - 13.2 281 50 8 ±12.0 ±83 ±0.0 59 500 A216RHI 12 10.8 - 13.2 280 50 8 ±15.0 ±66 ±0.0 59 500 A221RHI 24 21.6 - 26.4 134 30 3 5.0 400 0.0 62 250 A222RHI 24 21.6 - 26.4 131 30 3 12.0 165 0.0 63 250 A223RHI 24 21.6 - 26.4 130 30 3 15.0 133 0.0 64 250 A224RHI 24 21.6 - 26.4 93 30 3 ±5.0 ±100 ±0.0 45 250 A225RHI 24 21.6 - 26.4 143 30 3 ±12.0 ±83 ±0.0 58 250 A226RHI 24 21.6 - 26.4 142 30 3 ±15.0 ±66 ±0.0 58 250 Pin Single Dual 1, 2 +Vin +Vin 10, 11 No Pin Common 12 -Vout No Pin 13 +Vout -Vout

15 No Pin +Vout

23, 24 -Vin -Vin Model Selection Guide Mechanical Dimensions Mechanical Notes:

  • All dimensions are typical in inch es (mm)
  • Tolerance x.xx = ±0.01 (±0.25) Notes: 1. When measuring output ripple, it is recommended that an external 0.33 µ F ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 1.5 µ F capacitors will reduce the output ripple. 2. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 3. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and fl oat the output common. 4. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applica- tions where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted close to the converter. For 5V input units a 4.7µ F is recommended, and for 12V & 24V units a 2.2 µ F. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Pin Connections Capacitive Load Single Output (µF Max) Dual Output (µF Max) 470 ±220 MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072  TEL: (781) 344-8226  FAX: (781) 344-8481  E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Derating Curve