A1100RW MPD | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Key Features:  10W Output Power  Compact DIP Case  2:1 Input Voltage Range  Single & Dual Outputs  1,500 VDC Isolation  Meets EN55022 Class “A”  1.0 MH MTBF  Industry Standard Pin-Out A1 100RW Miniature, 10W DIPMiniature, 10W DIP Single & Dual OutputSingle & Dual Output DC/DC Con vert ersDC/DC Con vert ers Series Input Parameter Conditions Min. Typ. Max. Units Input Start Voltage 12 VDC Input 7.0 8.0 9.0 VDC24 VDC Input 14.0 16.0 18.0 48 VDC Input 30.0 33.0 36.0 Input Filter π (Pi) Filter (Complies with EN55022 Class “A”) Reverse Polarity Input Current 0.5 A Short Circuit Input Power 2,500 mW Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±0.6 ±1.2 % Output Voltage Balance Dual Output , Balanced Loads ±0.5 ±1.0 % Line Regulation Vin = Min to Max ±0.3 ±1.0 % Load Regulation, 2.5 Vout Models Iout = 10% to 100% ±0.7 ±1.5 % Load Regulation, All Other Models Iout = 10% to 100% ±0.5 ±1.2 % Ripple & Noise (20 MHz) (Note 1) 50 85 mV P - P Ripple & Noise (20 MHz) Over Line, Load & Temp. 100 mV P - P Ripple & Noise (20 MHz) 15 mV rms Output Power Protection 110 150 180 % Transient Recovery Time (Note 2) 25% Load Step Change 250 500 µSec Transient Response Deviation ±3.0 ±5.0 % Temperature Coeffi cient ±0.01 ±0.02 %/ ºC Output Short Circuit Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Voltage Test Flash Tested for 1 Second 1,650 VDC Isolation Resistance 500 VDC 1,000 MΩ Isolation Capacitance 100 kHz, 1V 1,000 1,200 pF Switching Frequency 400 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +25 +60 ºC Operating Temperature Range Case -40 +90 ºC Storage Temperature Range -40 +125 ºC Cooling Free Air Convection Humidity RH, Non-condensing 95 % Conducted EMI EN55022 Class “A” Physical Case Material Metal with Non-Conductive Base Weight 0.61 Oz (17.3g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F, 25ºC, Gnd Benign 1.0 MHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 12 VDC Input -0.7 25.0 VDC24 VDC Input -0.7 50.0 48 VDC Input -0.7 100.0 Lead Temperature 1.5 mm From Case For 10 Sec 260 ºC Internal Power Dissipation All Models 2,500 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com RoHS Compliant Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.

Mechanical Notes:  All dimensions are typical in inch es (mm)  Tolerance x.xx = ±0.01 (±0.25) Notes: 1. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. However, they may not meet all specifi cations. 4. Dual output units may be connected to provide a 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and fl oat the output common. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz) capacitor be mounted close to the converter. For 12V input units a 12 µF is recommended, for 24V input units, a 4.7 µF; and for 48V units a 2.2 µF. 6. Models with 5.1 VDC outputs are available. Please contact the factory for details. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Model Number Input Output Effi ciency (%, Typ) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Refl ected Ripple Current (mA, Typ) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load A1102RW 12 9.0 - 18.0 1,006 40 60 3.3 3,000 300.0 82 2,000 A1103RW 12 9.0 - 18.0 1,004 40 60 5.0 2,000 200.0 83 2,000 A1104RW 12 9.0 - 18.0 957 40 60 12.0 833 83.0 87 2,000 A1105RW 12 9.0 - 18.0 968 40 60 15.0 666 66.6 86 2,000 A1106RW 12 9.0 - 18.0 957 40 60 ±12.0 ±416 ±42.0 87 2,000 A1107RW 12 9.0 - 18.0 968 40 60 ±15.0 ±333 ±33.0 86 2,000 A1111RW 24 18.0 - 36.0 377 20 40 2.5 3,000 300.0 83 1,000 A1112RW 24 18.0 - 36.0 485 20 40 3.3 3,000 300.0 85 1,000 A1113RW 24 18.0 - 36.0 479 20 40 5.0 2,000 200.0 87 1,000 A1114RW 24 18.0 - 36.0 479 20 40 12.0 833 83.0 87 1,000 A1115RW 24 18.0 - 36.0 478 20 40 15.0 666 66.6 87 1,000 A1116RW 24 18.0 - 36.0 473 20 40 ±12.0 ±416 ±42.0 88 1,000 A1117RW 24 18.0 - 36.0 478 20 40 ±15.0 ±333 ±33.0 87 1,000 A1121RW 48 36.0 - 75.0 188 10 40 2.5 3,000 300.0 83 500 A1122RW 48 36.0 - 75.0 243 10 40 3.3 3,000 300.0 85 500 A1123RW 48 36.0 - 75.0 239 10 40 5.0 2,000 200.0 87 500 A1124RW 48 36.0 - 75.0 240 10 40 12.0 833 83.0 87 500 A1125RW 48 36.0 - 75.0 239 10 40 15.0 666 66.6 87 500 A1126RW 48 36.0 - 75.0 236 10 40 ±12.0 ±416 ±42.0 88 500 A1127RW 48 36.0 - 75.0 243 10 40 ±15.0 ±333 ±33.0 87 500 Pin Single Dual Pin Single Dual 2, 3 -Vin -Vin 14 +Vout +Vout

9 No Pin Common 16 -Vout Common

11 NC -Vout 22, 23 +Vin +Vin

NC: No Connection Pin Connections Output (VDC) 2.5 3.3 5.0 5.1 12 15 ±12 ±15 µF Max 2,200 2,200 2,200 2,200 820 470 ±220 ±150 Capacitive Load MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072  TEL: (781) 344-8226  FAX: (781) 344-8481  E-Mail: sales@micropowerdirect.com Derating Curve