A0505S-2W REICU | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 1
Technical content
Features
Efficiency up to 78% 1.6kVDC Isolation Wide temperature performance at full
1 Watt load,-40℃ to 85℃
Industry standard required Note Page 1 of 2 REV:3.1 Page 2 of 2 REV:3.1 A****M-1W Series 1600VDC Isolated 1W Double Output SIP-Package +Vin GND +Vo -Vo DC/DC Converter Cout Load Cin Cout Load COM Input Characteristics Min Typ Max UnitsParameter Condition Input Surge Voltage (1 sec. Max.) 3.3V Input Models 5V Input Models 12V Input Models 24V Input Models -0.7 -0.7 -0.7 -0.7 Input Filter Internal CapacitorAll Models VDC *All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted.
100 KHzSwitching frequency Full load,nominal input
Line regulation Vin change 1% +1.5 % Load regulation Ripple and noise 10%~100% load BW=DC to 20MHz 75 Vp-pm %6.5 15 Output Characteristics Min Typ Max UnitsParameter Condition ≤100 +1.2 Short circuit Protection Continuous,Automatic Recovery Model Selection Guide Order Code A0505M-1W(R2) A0509M-1W(R2) A0512M-1W(R2) A0515M-1W(R2) A1205M-1W(R2) A1212M-1W(R2) A2405M-1W(R2) A2412M-1W(R2) A2424M-1W(R2) A0524M-1W(R2) A1209M-1W(R2) A1215M-1W(R2) A1224M-1W(R2) A2409M-1W(R2) A2415M-1W(R2) Efficiency(%) (Typ) Nominal Range Vin(V) Vo(V) Io(mA) Output 4.5-5.5 10.8-13.2 24 21.6-26.4 +5 +100 +56 +42 +33 +21 +100 +56 +42 +33 +21 +100 +56 +42 +33 +21 +12 +15 +24 +12 +15 +24 +12 +15 +24 Max capacitive Load 100 100 100 100 100 100 100 100 100 Short circuit protection( Suffix“R2”,optional) Note: Unit:mm(inch) 6.00 (0.236) 0.90 (0.035) 2.18 (0.086) 2.54 (0.10) (Bottom View) 1 2 4 5 6 0.30 (0.012) 0.50(0.020) 1 2 4 5Pin 6 Function GNDVin -Vo COM +Vo Silk-screen 16.50(0.650) 9.50 (0.374) 0.50(0.020) 4.10 (0.161) www.reicu.com E-mail:service@reicu.com www.reicu.com E-mail:service@reicu.com DC/DC CONVERTER GDM****S-2W Series Output load Current(%) OutputVoltage Accuracy(%) +10% +5% +2.5% -2.5% -7.5% 10 25 50 75 100 NOMV Typical Load Line Tolerance Envelopes Curve 100 -40 0 40 12080 Safe Operating Area Output Power(%) Ambient Temperature(℃) Temperature Derating Graph Curve Mechanical Dimension & Pin Connections 1.To ensure this module can operate efficinetly and reliably,During operation,the minimum output load is not less than 10% of the full load. 2.Other input and output voltage may be available, please 3.Specifications subject to change without notice -40 +85 -55 +125
6000 VDC
MΩ1000 3.5×106 Operating Temperature All output types Storage Cooling Free air convection 1mA≤1minuteIsolation voltage Isolation resistance 500VDC MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition Switching Frequency 100 KHz Input/Output Ripple Reduction Reduce output ripple, it isrecommended to use capacitors at the input/output. External Capacitor Table Vin(VDC) Cin(uF) Vout(VDC) Cout(uF) 5 12 15 24 4.7 2.2 2.2 1 5 9 12 15 4.7 4.7 2.2 1 Efficiency up to 79% 6kVDC Isolation Wide temperature performance at full
2 Watt load,-40℃ to 85℃
REV:15.2 Page 2 of 2 REV:15.2 Input Characteristics Min Typ Max UnitsParameter Condition Input Surge Voltage (1 sec. Max.) 5V Input Models 12V Input Models 24V Input Models -0.7 -0.7 -0.7 Input Filter Internal CapacitorAll Models VDC * All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. Line regulation Vin change 1% +1.5 % Load regulation Ripple and noise 10%~100% load BW=DC to 20MHz 90 Vp-pm %6.5 15 Output Characteristics Min Typ Max UnitsParameter Condition ≤150 +1.2 Short circuit Protection Continuous,Automatic Recovery GDM**S-2W Series 6000VDC Isolated 2W Double Output DIP-Package Model Selection Guide Order Code GDM0505S-2W GDM0509S-2W GDM0512S-2W GDM0515S-2W GDM1205S-2W GDM1212S-2W GDM1209S-2W GDM1215S-2W Efficiency(%) (Typ) Nominal Range Vin(V) Vo(V) Io(mA) Output 5 4.5-5.5 12 10.8-13.2 +5 +200 +111 +83 +67 +12 +15 +12 +15 +Vin GND +Vo -Vo DC/DC Converter Cout Load Cin Cout Load COM Max capacitive Load GDM2405S-2W GDM2412S-2W GDM2409S-2W GDM2415S-2W 24 21.6-26.4 +12 +15 eR ICU eR ICU Continuous short circuit Protection www.reicu.com E-mail:service@reicu.com www.reicu.com E-mail:service@reicu.com Silk-screen (Bottom View) 33.0(1.30) 14.50 (0.57) 21 8 9 10 11 12 13141516172324 10.20 (0.402) 16.50 (0.65) 0.55(0.022) 27.94(1.10) 5.00 (0.197) 0.3 (0.012) 17.0(0.67) Lateral View Lateral View 2.54(0.1) +200 +111 +83 +67 +200 +111 +83 +67 Note: Unit:mm(inch) 1 2 GNDVin -Vo Pin +VoCOM 8,17 10,15 12,13 Others NCFunction eR ICU DC/DC CONVERTER H**S-2W Series 1.To ensure this module can operate efficinetly and reliably,During operation,the minimum output load is not less than 10% of the full load. 2.Other input and output voltage may be available, please 3.Specifications subject to change without notice Note Output load Current(%) OutputVoltage Accuracy(%) +10% +5% +2.5% -2.5% -7.5% 10 25 50 75 100 NOMV Typical Load Line Tolerance Envelopes Curve 100 -40 0 40 12080 Safe Operating Area Output Power(%) Ambient Temperature(℃) Temperature Derating Graph Curve Page 1 of 2 REV:3.1 Page 2 of 2 REV:3.1 Input Characteristics Min Typ Max UnitsParameter Condition Input Surge Voltage (1 sec. Max.) 3.3V Input Models 5V Input Models 12V Input Models 24V Input Models -0.7 -0.7 -0.7 -0.7 Input Filter Internal CapacitorAll Models VDC *All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. Line regulation Vin change 1% +1.5 % Load regulation Ripple and noise 10%~100% load BW=DC to 20MHz 75 Vp-pm %6.5 15 Output Characteristics Min Typ Max UnitsParameter Condition ≤100 +1.2 Short circuit Protection Continuous,Automatic Recovery H****S-2W Series 6000VDC Isolated 2W Single Output SIP-Package -40 +85 -55 +125 MΩ1000 3.5×106 Operating Temperature All output types Storage Cooling Free air convection 1mA≤1minuteIsolation voltage Isolation resistance 500VDC MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition Switching Frequency 100 KHz External Capacitor Table Vin(VDC) Cin(uF) Vout(VDC) Cout(uF) 5 12 15 24 4.7 2.2 2.2 1 5 9 12 15 10 4.7 2.2 1 Input/Output Ripple Reduction Reduce output ripple, it isrecommended to use capacitors at the input/output. 0.47 +Vin GND +Vo -Vo DC/DC Converter Cout Load Cin Mechanical Dimension & Pin Connections Model Selection Guide Order Code Nominal Range Vin(V) Vo(V) Io(mA) Output Max capacitive Load Efficiency(%) (Typ) H0505S-2W H0509S-2W H0512S-2W H0515S-2W 5 4.5-5.5 167 400 222 133 Efficiency up to 81% 6kVDC Isolation Wide temperature performance at full 2Watt load,-40℃ to 85℃ Single output Internal SMD Construction 330 220 220 220 75H1205S-2W H1212S-2W H2405S-2W H2412S-2W H2424S-2W 12 10.8-13.2 24 21.6-26.4 78H1209S-2W H1215S-2W H1224S-2W H2409S-2W H2415S-2W 167 400 222 133 167 400 222 133 330 220 220 220 150 330 220 220 220 150 19.60(0.772) 12.00 (0.472) 4.10 (1.614) 0.50 (0.020) 2.54 (0.100) 9.80 (0.386) 2.80 (0.110) 2.18 (0.086) Silk-screen 1 2 5 7 0.50 (0.020) 0.30 (0.012) Note: Unit:mm(inch) 1 2 5 GNDVin -Vo Pin Function +Vo (Bottom View) Continuous short circuit Protection www.reicu.com E-mail:service@reicu.com www.reicu.com E-mail:service@reicu.com H0524S-2W 7924 83 150 DC/DC CONVERTER G****S-2W Series 1.To ensure this module can operate efficinetly and reliably,During operation,the minimum output load is not less than 10% of the full load. 2.Other input and output voltage may be available, please 3.Specifications subject to change without notice Note Output load Current(%) OutputVoltage Accuracy(%) +10% +5% +2.5% -2.5% -7.5% 10 25 50 75 100 NOMV Typical Load Line Tolerance Envelopes Curve 100 -40 0 40 12080 Safe Operating Area Output Power(%) Ambient Temperature(℃) Temperature Derating Graph Curve Page 1 of 2 REV:3.1 Page 2 of 2 REV:3.1 Input Characteristics Min Typ Max UnitsParameter Condition Input Surge Voltage (1 sec. Max.) 3.3V Input Models 5V Input Models 12V Input Models 24V Input Models -0.7 -0.7 -0.7 -0.7 Input Filter Internal CapacitorAll Models VDC * All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. Line regulation Vin change 1% +1.5 % Load regulation Ripple and noise 10%~100% load BW=DC to 20MHz 75 Vp-pm %6.5 15 Output Characteristics Min Typ Max UnitsParameter Condition ≤100 +1.2 Short circuit Protection Continuous,Automatic Recovery G****S-2W Series 6000VDC Isolated 2W Double Output SIP-Package -40 +85 -55 +125 MΩ1000 3.5×106 Operating Temperature All output types Storage Cooling Free air convection 1mA≤1minuteIsolation voltage Isolation resistance 500VDC MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition Switching Frequency 100 KHz Efficiency up to 81% 6kVDC Isolation Wide temperature performance at full 2Watt load,-40℃ to 85℃ Double output Internal SMD Construction Model Selection Guide Order Code Nominal Range Vin(V) Vo(V) Io(mA) Output Max capacitive Load Efficiency(%) (Typ) G0505S-2W G0509S-2W G0512S-2W G0515S-2W 5 4.5-5.5 75G1205S-2W G1212S-2W G2405S-2W G2412S-2W G2424S-2W 12 10.8-13.2 24 21.6-26.4 78G1209S-2W G1215S-2W G1224S-2W G2409S-2W G2415S-2W +200 +111 +83 +67 +12 +15 +24 +12 +15 +24 +12 +15 +200 +111 +83 +67 +42 +200 +111 +83 +67 +42 External Capacitor Table Vin(VDC) Cin(uF) Vout(VDC) Cout(uF) 5 12 15 24 4.7 2.2 2.2 1 5 9 12 15 10 4.7 2.2 1 Input/Output Ripple Reduction Reduce output ripple, it isrecommended to use capacitors at the input/output. 0.47 +Vin GND +Vo -Vo DC/DC Converter Cout Load Cin Cout Load COM Mechanical Dimension & Pin Connections 150 150 100 100 150 150 100 100 150 150 100 100 19.60(0.772) 12.00 (0.472) 4.10 (1.614) 0.50 (0.020) 2.54 (0.100) 9.80 (0.386) 2.80 (0.110) 2.18 (0.086) Silk-screen 1 2 5 7 0.50 (0.020) 0.30 (0.012) Note: Unit:mm(inch) 1 2 5 GNDVin -Vo Pin Function COM +Vo (Bottom View) Continuous short circuit Protection www.reicu.com E-mail:service@reicu.com www.reicu.com E-mail:service@reicu.com DC/DC CONVERTER Efficiency up to 84% 3kVDC Isolation Wide temperature performance at full Industry standard required 1.To ensure this module can operate efficinetly and reliably,During operation,the minimum output load is not less than 10% of the full load. 2.Other input and output voltage may be available, please 3.Specifications subject to change without notice Note Output load Current(%) OutputVoltage Accuracy(%) +10% +5% +2.5% -2.5% -7.5% 10 25 50 75 100 NOMV Typical Load Line Tolerance Envelopes Curve 100 -40 0 40 12080 Safe Operating Area Output Power(%) Ambient Temperature(℃) Temperature Derating Graph Curve Page 1 of 2 REV:3.1 Page 2 of 2 REV:3.1 -40 +85 -55 +125
3000 VDC
MΩ1000 3.5×106 Operating Temperature All output types Storage Cooling Free air convection 1mA≤1minuteIsolation voltage Isolation resistance 500VDC MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition Switching Frequency 100 110 KHz Input Characteristics Min Typ Max UnitsParameter Condition Input Surge Voltage (1 sec. Max.) 3.3V Input Models 5V Input Models 12V Input Models 24V Input Models -0.7 -0.7 -0.7 -0.7 Input Filter Internal CapacitorAll Models VDC *All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. Line regulation Vin change 1% +1.5 % Load regulation Ripple and noise 10%~100% load BW=DC to 20MHz 75 Vp-pm %6.5 15 Output Characteristics Min Typ Max UnitsParameter Condition ≤100 +1.2 Short circuit Protection Continuous,Automatic Recovery E**S/D-2W(R2) Series 3000VDC Isolated 2W Double Output SIP/DIP-Package External Capacitor Table Vin(VDC) Cin(uF) Vout(VDC) Cout(uF) 5 12 15 24 4.7 2.2 2.2 1 5 9 12 15 10 4.7 2.2 1 Input/Output Ripple Reduction Reduce output ripple, it isrecommended to use capacitors at the input/output. 0.47 +Vin GND +Vo -Vo DC/DC Converter Cout Load Cin Cout Load COM Model Selection Guide Order Code E0505S/D-2W(R2) E0509S/D-2W(R2) E0512S/D-2W(R2) E0515S/D-2W(R2) E1205S/D-2W(R2) E1212S/D-2W(R2) E2405S/D-2W(R2) E2412S/D-2W(R2) E2424S/D-2W(R2) E0524S/D-2W(R2) E1209S/D-2W(R2) E1215S/D-2W(R2) E1224S/D-2W(R2) E2409S/D-2W(R2) E2415S/D-2W(R2) Efficiency(%) (Typ) Nominal Range Vin(V) Vo(V) Io(mA) Output 4.5-5.5 10.8-13.2 24 21.6-26.4 +200 +111 +83 +67 +42 +200 +111 +83 +67 +42 +200 +111 +83 +67 +42 +12 +15 +24 +12 +15 +24 +12 +15 +24 Mechanical Dimension & Pin Connections Max capacitive Load 150 150 100 150 150 100 150 150 100 100 100 100 Short circuit protection( Suffix“R2”only SIP,optional) Note: Unit:mm(inch) 7.00 (0.276) 0.90 (0.035) 2.18 (0.086) 2.54 (0.10) 19.60(0.772) 9.50 (0.374) 0.50(0.020) Silk-screen 1 2 5 0.30 (0.012) 0.50(0.020) 4.10 (0.161) 1 2 5 GNDVin -Vo Pin Function +Vo 1 107 8 GND -Vo Pin Function +Vo VinNC 15.24(0.60) 1 7 14 8 7.62 (0.30) 10.00 (0.394) 20.00(0.787) 8.20 (0.323) 4.10(0.161) Silk-screen 2.54(0.100) 0.30 (0.012) 0.50(0.020) 10 9 COM (Bottom View) (Bottom View) E**S/D-2W(R2) Series Suffix“R2” www.reicu.com E-mail:service@reicu.com www.reicu.com E-mail:service@reicu.com DC/DC CONVERTER External Capacitor Table Vin(VDC) Cin(uF) Vout(VDC) Cout(uF) 5 12 15 24 4.7 2.2 2.2 1 5 9 12 15 10 4.7 2.2 1 Input/Output Ripple Reduction +Vin GND +Vo -Vo DC/DC Converter Reduce output ripple, it isrecommended to use capacitors at the input/output. Cout Load Cin 24 0.47 Efficiency up to 83% 3kVDC Isolation Wide temperature performance at full Industry standard required 1.To ensure this module can operate efficinetly and reliably,During operation,the minimum output load is not less than 10% of the full load. 2.Other input and output voltage may be available, please 3.Specifications subject to change without notice Note Output load Current(%) OutputVoltage Accuracy(%) +10% +5% +2.5% -2.5% -7.5% 10 25 50 75 100 NOMV Typical Load Line Tolerance Envelopes Curve 100 -40 0 40 12080 Safe Operating Area Output Power(%) Ambient Temperature(℃) Temperature Derating Graph Curve Page 1 of 2 REV:3.1 Page 2 of 2 REV:3.1 Input Characteristics Min Typ Max UnitsParameter Condition Input Surge Voltage (1 sec. Max.) 3.3V Input Models 5V Input Models 12V Input Models 24V Input Models -0.7 -0.7 -0.7 -0.7 Input Filter Internal CapacitorAll Models VDC * All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. Line regulation Vin change 1% +1.5 % Load regulation Ripple and noise 10%~100% load BW=DC to 20MHz 75 Vp-pm %6.5 15 Output Characteristics Min Typ Max UnitsParameter Condition ≤100 +1.2 Short circuit Protection Continuous,Automatic Recovery F****S/D-2W(R2) Series 3000VDC Isolated 2W Single Output SIP/DIP-Package -40 +85 -55 +125 MΩ1000 3.5×106 Operating Temperature All output types Storage Cooling Free air convection 1mA≤1minuteIsolation voltage Isolation resistance 500VDC MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition Switching Frequency 100 KHz Mechanical Dimension & Pin Connections Model Selection Guide Order Code F0505S/D-2W(R2) F0509S/D-2W(R2) F0512S/D-2W(R2) F0515S/D-2W(R2) F1205S/D-2W(R2) F1212S/D-2W(R2) F2405S/D-2W(R2) F2412S/D-2W(R2) F2424S/D-2W(R2) F0524S/D-2W(R2) F1209S/D-2W(R2) F1215S/D-2W(R2) F1224S/D-2W(R2) F2409S/D-2W(R2) F2415S/D-2W(R2) Efficiency(%) (Typ) Nominal Range Vin(V) Vo(V) Io(mA) Output 4.5-5.5 10.8-13.2 24 21.6-26.4 167 400 222 133 167 400 222 133 167 400 222 133 Max capacitive Load 330 220 220 220 150 330 220 220 220 150 330 220 220 220 150 Short circuit protection( Suffix“R2”only SIP,optional) Note: Unit:mm(inch) 15.24(0.60) 1 7 14 8 7.62 (0.30) 10.00 (0.394) 20.00(0.787) 8.20 (0.323) 4.10(0.161) Silk-screen 2.54(0.100) 0.30 (0.012) 0.50(0.020) 7.00 (0.276) 0.90 (0.035) 2.18 (0.086) 2.54 (0.10) 19.60(0.772) 9.50 (0.374) 0.50(0.020) Silk-screen 1 2 5 0.30 (0.012) 0.50(0.020) 4.10 (0.161) 1 2 5 GNDVin -Vo Pin Function +Vo 1 107 8 GND -Vo Pin Function +Vo VinNC (Bottom View) (Bottom View) F****S/D-2W(R2) Series Suffix“R2” www.reicu.com E-mail:service@reicu.com www.reicu.com E-mail:service@reicu.com DC/DC CONVERTER Efficiency up to 83% 1.6kVDC Isolation Wide temperature performance at full Industry standard required 1.To ensure this module can operate efficinetly and reliably,During operation,the minimum output load is not less than 10% of the full load. 2.Other input and output voltage may be available, please 3.Specifications subject to change without notice Note Output load Current(%) OutputVoltage Accuracy(%) +10% +5% +2.5% -2.5% -7.5% 10 25 50 75 100 NOMV Typical Load Line Tolerance Envelopes Curve 100 -40 0 40 12080 Safe Operating Area Output Power(%) Ambient Temperature(℃) Temperature Derating Graph Curve Page 1 of 2 REV:3.1 Page 1 of 2 REV:3.1 Add -40 +85 -55 +125
1600 VDC
MΩ1000 3.5×106 Operating Temperature All output types Storage Cooling Free air convection 1mA≤1minuteIsolation voltage Isolation resistance 500VDC MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition Switching Frequency 100 110 KHz Input Characteristics Min Typ Max UnitsParameter Condition Input Surge Voltage (1 sec. Max.) 3.3V Input Models 5V Input Models 12V Input Models 24V Input Models -0.7 -0.7 -0.7 -0.7 Input Filter Internal CapacitorAll Models VDC * All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. Line regulation Vin change 1% +1.5 % Load regulation Ripple and noise 10%~100% load BW=DC to 20MHz 75 Vp-pm %6.5 15 Output Characteristics Min Typ Max UnitsParameter Condition ≤100 +1.2 1600VDC Isolated 2W Double Output SIP-Package External Capacitor Table Vin(VDC) Cin(uF) Vout(VDC) Cout(uF) 5 12 15 24 4.7 2.2 2.2 1 5 9 12 15 10 4.7 2.2 1 Input/Output Ripple Reduction Reduce output ripple, it isrecommended to use capacitors at the input/output. 0.47 +Vin GND +Vo1 DC/DC Converter Cout Load Cin Cout Load -Vo1 +Vo2 -Vo2 Mechanical Dimension & Pin Connections Model Selection Guide Order Code D050505S-2W D050909S-2W D051212S-2W D051515S-2W D120505S-2W D121212S-2W D240505S-2W D241212S-2W D242424S-2W D052424S-2W D120909S-2W D121515S-2W D122424S-2W D240909S-2W D241515S-2W Efficiency(%) (Typ) Nominal Range Vin(V) Vo(V) Io(mA) Output 4.5-5.5 10.8-13.2 24 21.6-26.4 5/5 200/200 Max capacitive Load 150 150 100 150 150 100 150 150 100 100 100 100 Low ripple & noise 19.60(0.772) 9.50 (0.374) 0.50(0.020) 4.10 (0.161) 7.00 (0.276) 0.90 (0.035) 2.18 (0.086) 2.54 (0.10) Silk-screen 1 2 4 5 6 7 0.30 (0.012) 0.50(0.020) 1 2 4 5Pin 6 7 Function GNDVin -Vo1 +Vo1 -Vo2 +Vo2 Note: Unit:mm(inch) (Bottom View) www.reicu.com E-mail:service@reicu.com www.reicu.com E-mail:service@reicu.com DC/DC CONVERTER Efficiency up to 83% 1.6kVDC Isolation Wide temperature performance at full Industry standard required 1.To ensure this module can operate efficinetly and reliably,During operation,the minimum output load is not less than 10% of the full load. 2.Other input and output voltage may be available, please 3.Specifications subject to change without notice Note Output load Current(%) OutputVoltage Accuracy(%) +10% +5% +2.5% -2.5% -7.5% 10 25 50 75 100 NOMV Typical Load Line Tolerance Envelopes Curve 100 -40 0 40 12080 Safe Operating Area Output Power(%) Ambient Temperature(℃) Temperature Derating Graph Curve Page 1 of 2 REV:3.1 Page 2 of 2 REV:3.1 Add -40 +85 -55 +125 MΩ1000 3.5×106 Operating Temperature All output types Storage Cooling Free air convection 1mA≤1minuteIsolation voltage Isolation resistance 500VDC MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition Switching Frequency 100 110 KHz Input Characteristics Min Typ Max UnitsParameter Condition Input Surge Voltage (1 sec. Max.) 3.3V Input Models 5V Input Models 12V Input Models 24V Input Models -0.7 -0.7 -0.7 -0.7 Input Filter Internal CapacitorAll Models VDC *All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. Line regulation Vin change 1% +1.5 % Load regulation Ripple and noise 10%~100% load BW=DC to 20MHz 75 Vp-pm %6.5 15 Output Characteristics Min Typ Max UnitsParameter Condition ≤100 +1.2 Short circuit Protection Continuous,Automatic Recovery A**S/D-2W(R2) Series 1600VDC Isolated 2W Double Output SIP/DIP-Package External Capacitor Table Vin(VDC) Cin(uF) Vout(VDC) Cout(uF) 5 12 15 24 4.7 2.2 2.2 1 5 9 12 15 10 4.7 2.2 1 Input/Output Ripple Reduction Reduce output ripple, it isrecommended to use capacitors at the input/output. 0.47 +Vin GND +Vo -Vo DC/DC Converter Cout Load Cin Cout Load COM Model Selection Guide Order Code A0505S/D-2W(R2) A0509S/D-2W(R2) A0512S/D-2W(R2) A0515S/D-2W(R2) A1205S/D-2W(R2) A1212S/D-2W(R2) A2405S/D-2W(R2) A2412S/D-2W(R2) A2424S/D-2W(R2) A0524S/D-2W(R2) A1209S/D-2W(R2) A1215S/D-2W(R2) A1224S/D-2W(R2) A2409S/D-2W(R2) A2415S/D-2W(R2) Efficiency(%) (Typ) Nominal Range Vin(V) Vo(V) Io(mA) Output 4.5-5.5 10.8-13.2 24 21.6-26.4 +200 +111 +83 +67 +42 +200 +111 +83 +67 +42 +200 +111 +83 +67 +42 +12 +15 +24 +12 +15 +24 +12 +15 +24 Mechanical Dimension & Pin Connections Max capacitive Load 150 150 100 150 150 100 150 150 100 100 100 100 Short circuit protection( Suffix“R2”only SIP,optional) A S-2W 7.00 (0.276) 0.90 (0.035) 2.18 (0.086) 2.54 (0.10) 19.60(0.772) 9.50 (0.374) 0.50(0.020) Silk-screen 1 2 4 5 6 0.30 (0.012) 0.50(0.020) 4.10 (0.161) 1 2 4 5Pin 6 Function GNDVin -Vo COM +Vo A D-2W 15.24(0.60) 1 7 14 11 9 8 7.62 (0.30) 10.00 (0.394) 20.00(0.787) 8.20 (0.323) 4.10(0.161) Silk-screen 2.54(0.100) 0.30 (0.012) 0.50(0.020) 1 7 8 9Pin 11 14 Function GND -VoCOM +VoNC Vin Note: Unit:mm(inch) (Bottom View) (Bottom View) A**S/D-2W(R2) Series Suffix“R2” www.reicu.com E-mail:service@reicu.com www.reicu.com E-mail:service@reicu.com