Features

  • 0 to 1050 V AC/DC voltage
  • 0 to 22 A AC/DC current
  • 1 Ω to 1 GΩ resistance
  • Thermocouple and Pt100 simulation
  • Digital frequency
  • Capacitance
  • Optional oscilloscope and power calibration
  • Optional clamp meter calibration
  • RS-232/USB/GPIB interfaces
  • PC Virtual Control Software included
  • Supplied with test lead set
  • EasyCal software compatible EasyCal Calibration Software The 5025E can be controlled via Time Electronics EasyCal software to automate the calibration process. This provides increased speed of calibration and consistency of results. Produce traceable calibration certificates and test reports for quality standards with additional uncertainty information for ISO 17025 conformance.

5025E Multifunction Calibrator Time Electronics Ltd, Unit 5, T O N Business Park, 2-8 Morley Road, T onbridge, Kent, TN9 1RA, United Kingdom T : +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com Technical Specifications (for full technical data see extended specifications sheet) Function Range / Values Best 1 year Specification Voltage DC 0 to ± 1050 V ± 40 ppm of setting Current DC 0 to ± 22 A

1100 A with clamp meter adaptor (option 9780) ± 120 ppm of setting

Voltage AC 1 mV to 1050 V / 20 Hz to 20 kHz sine-wave ± 0.04 % of setting Current AC 10 μA to 22 A / 20 Hz to 1 kHz sine-wave

100 A with current transformer (option 9790)

1100 A with clamp meter adaptor (option 9780)

± 0.07 % of setting Thermocouple simulation -210 to 1820 °C. T ype J, K, R, T , S, B, E, N ± 0.3 °C Digital frequency/period 0.1 Hz to 10 MHz / 100 ns to 10 s ± 20 ppm of setting Conductance 100 ms to 1 ns (decade values) ± 60 ppm of setting Decade resistance 10 Ω to 1 GΩ (decade values) ± 60 ppm of setting Simulated resistance 40 Ω to 40 kΩ (variable) ± 0.02 % of setting PT100 simulation -140 °C to 850 °C ± 0.25 °C Capacitance 10 nF , 20 nF , 50 nF , 100 nF , 1 μF ± 0.25 % of setting Option 9780: Clamp meter adaptor AC/DC Current up to 1100 A (DC, 45 to 90 Hz) ± 0.5 % Option 9770: Oscilloscope Calibration Amplitude 2 mV to 200 V and 1 mV to 2 V 50 Ω (Square-wave or DC) ± 0.05 % Frequency/Period 0.1 Hz to 100 MHz / 10 ns to 10 s (fixed values 1, 2, 5 sequence) ± 20 ppm Duty cycle 3 frequencies: 100 Hz, 1 kHz, 10 kHz, settable from 0 to 100 % – Fast-rise < 400 ps. Bandwidth checking up to 400 MHz – Option 9783: Frequency reference 0.1 Hz to 10 MHz enhanced frequency accuracy reference ± 0.1 ppm (enhanced accuracy for timer/counters) Option 9769: 2.2 GHz Sweep 50 MHz to 2.2 GHz levelled sine-wave (0.5, 1, 1.5 V pk-pk) Amplitude ± 1 %, Frequency ± 20 ppm Option 9797: Power Calibration Phase / Power factor ± 90° / 0.00 to 1.00 PF ± 0.3° Option 9702: Enhanced Performance Pack (added values/types shown in bold where applicable) Full range resistance 1 Ω to 120 MΩ (variable) ± 100 ppm of setting RTD Simulation –180 to 850 °C. T ype Pt100, Pt200, Pt500, Pt1000 ± 0.03 °C Extended thermocouple simulation –210 to 2315 °C. T ype J, K, R, T , S, B, E, N, C, L, U ± 0.05 °C Extended capacitance 1nF , 10nF , 20nF , 50nF , 100nF , 200nF , 500nF , 1μF , 10μF , 20μF , 50μF , 100μF ± 0.2 % of setting Extended AC voltage frequency 1 mV to 200 mV/300 kHz, 200 mV to 2 V/1 MHz ± 0.05 % of setting External Options External Adaptors/Instruments 9780: Clamp meter adaptor (1 and 50 turn coil) • 9773: Optical tacho adaptor • 9790: 100 Amp AC current transformer 9760: Power amplifier (60 V AC, 90 V DC, 100 mA) • 9762: Rubidium high stability frequency reference 9764: Current probe calibration adaptor • 9766: Low noise attenuator (1000:1) • 9767: Low noise attenuator (100:1) Accessories and Calibration Certificates 9085: Soft carry case • 9059: Hard transit case • 9728: 19 " Universal rack mount kit 9796: Premium test lead set • C159: Traceable calibration certificate • C103: Accredited calibration certificate EasyCal Software ECFLA: EasyCal full license • 9777: Bar code reader • 9779: Job and address label printer EC2FL/EC2WL: Additional user licenses • EAD: EasyAdmin add-on • EWC: WebCerts • CREP: Crystal Reports software General Specifications Due to continuous development Time Electronics reserves the right to change specifications without prior notice.

5025E Multifunction Calibrator Time Electronics Ltd, Unit 5, T O N Business Park, 2-8 Morley Road, T onbridge, Kent, TN9 1RA, United Kingdom T : +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com

Ordering Information

Multifunction Calibrator (40 ppm) AC/DC 1 kV / 22 A. Decade Resistance to 1 GΩ, Simulated Resistance 40 Ω to 40 kΩ, Thermocouple Simulation (J,K,R,T ,S,B,E,N), Conductance, Pt100 Simulation, Capacitance, 10 MHz Frequency, Basic T est Lead Set, Virtual Control Software. 5025C Internal options 9702 5025E Enhanced Performance Pack Full range variable resistance, extended temperature functions, extended capacitance, and increased ACV frequency bandwidth.

9797 Power Calibration (0 to 20 kW AC and DC)

9770 Oscilloscope Calibration (1 mV to 200 V, 0.1 Hz to 100 MHz / Bandwidth checking to 400 MHz) 9783 Oven-Controlled Frequency Reference (for timer/counters, increases accuracy to 0.1 ppm from 0.1 Hz to 10 MHz). Option 9770 must be fitted. 9769 Oscilloscope Calibration 2.2 GHz Levelled Sine Generator 5025C Adaptors, accessories and calibration certificates

9762 Rubidium High Stability Frequency Reference (9770 internal scope option must be fitted)

9764 Current Probe Calibration Adaptor (9770 internal scope option must also be fitted)

9773 Optical T acho Adaptor

9780 Clamp Meter Adaptor (1 and 50 turn coil)

9790 100 Amp AC Current Transformer

9760 Power Amplifier (60 V AC, 90 V DC, 100 mA)

9766 External Low Noise Attenuator 1000:1

9767 External Low Noise Attenuator 100:1

9085 Soft Carry Case

9059 Hard Transit Case

9728 19 " Universal Rack Mount Kit

9796 Premium T est Lead Set (basic test lead set supplied as standard)

C159 Traceable calibration certificate (Factory) C103 Accredited calibration certificate (ISO 17025) EW01 Extended Warranty - 3 years total covering parts and labour. EasyCal software licenses ECFLA EasyCal Full License (discounted price when purchased with 5025E) EC2FL EasyCal Additional Full License (secondary user) EC2WL EasyCal Work Station License (full management/scheduling, no calibration run) EasyCal accessories

9795 Printer and Connectivity Kit

9777 Bar Code Reader

9778 Cal and ID Label Printer

9779 Job and Address Label Printer

CREP Crystal Reports Sofware: For detailed editing and formatting of certificate styles

9597 GPIB Cable

9743 PCI to GPIB Interface Card for PC

For full listings of EasyCal software and options please see the EasyCal brochure for information. v2a