5045 TIME-ELECTRONICS | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
Features
- 1 mV to 220 V square wave/DC
- Frequency 0.1 to 100 MHz
- Time markers 10 s to 10 ns
- Fast rise < 300 ps
- Front panel or PC virtual control
- External reference input
- 2.2 GHz levelled sine option
- Rubidium frequency reference option
- Current probe adaptor option
- RS-232, USB, GPIB interface EasyCal Calibration Software The 5045 can be controlled via Time Electronics EasyCal software to automate the calibration process. This provides increased speed of calibration and consistency of results. Produce traceable calibration certificates and test reports for quality standards with additional uncertainty information for ISO 17025 conformance.
5045 Oscilloscope Calibrator
Time Electronics Ltd, Unit 5, T O N Business Park, 2-8 Morley Road, T onbridge, Kent, TN9 1RA, United Kingdom T : +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com Technical Specifications Specifications are for 1 year and apply between 23 °C ± 5 °C Standard features Function Range Specification (± output + floor) Resolution Amplitude DC or 1 kHz Square wave DC Signal Square Wave Signal 2 to 200 mV (1 MΩ) 0.2 to 20 V (1 MΩ) 20 to 220 V (1 MΩ) 1 to 200 mV (50 Ω) 0.2 to 2 V (50 Ω) ± 0.20 % + 10 μV ± 0.05 % + 10 μV ± 0.05 % + 10 μV ± 0.25 % + 15 μV ± 0.25 % + 15 μV ± 0.25 % + 100 μV ± 0.25 % + 1 mV ± 0.25 % + 10 mV ± 0.25 % + 200 μV ± 0.5 % + 1 mV 10 μV 1 mV 10 mV 100 μV 1 mV The square wave signal is a chopped DC voltage with defined high and low levels, accuracy applies to the top line measurement relative to ground. Calibration is performed using the DC signal. Amplitude frequency accuracy < 10 ppm. Frequency 0.1 Hz to 10 MHz
20 MHz to 100 MHz
± 0.1 ppm ± 20 ppm Fixed outputs in 1, 2, 5, 10 sequenced steps Period 10 s to 100 ns 50 ns to 10 ns ± 0.1 ppm + 30 ps ± 20 ppm + 50 ps Square wave from 0.1 Hz to 50 MHz; sinusoidal at 100 MHz. Amplitude > 0.9 Vpp into 50 Ω. Duty Cycle 0 to 100% at 100 Hz, 1 kHz, 10 kHz Derived from the period (time interval) specification 0.01 % at 100 Hz 0.1 % at 1 kHz 1 % at 10 kHz Fast Rise* 10 MHz Rise time less than 300 ps (> 400 mVpp into 50 Ω)
2.2 GHz Levelled Sine-Wave (option 9769)*
Amplitude Range 0.35, 0.5, 1, 1.5 Vpp Frequency Range 50 to 199.9 MHz 200 to 499.9 MHz 500 to 999.9 MHz 1 to 2.2 GHz 1 year absolute accuracy 3 % 4 % 5.5 % 6.5 % Amplitude Range 2, 2.5, 3 Vpp Frequency Range 50 to 199.9 MHz 200 to 499.9 MHz 500 to 999.9 MHz 1 to 1.6 GHz 1 year absolute accuracy 3 % 4 % 5.5 % 6.5 % Amplitude Range 3.5 Vpp Frequency Range 50 to 199.9 MHz 200 to 499.9 MHz 500 to 999.9 MHz 1 to 1.3 GHz 1 year absolute accuracy 3 % 4 % 5.5 % 6.5 % The levelled sine option is calibrated at the terminal. Any external losses must be accounted for. *Accredited calibration is not available for this function/option. Note: 2.2 GHz levelled sine-wave option specifications apply to models manufactured after 2020. For models prior to this year please consult legacy specifications or contact us. External Options Rubidium reference (option 9762) Rubidium atomic clock 10 MHz frequency reference. Increases accuracy to 1 part in 1010. (Applies to 10 MHz maximum output on 5045) Current probe adaptor (option 9764) Battery powered external adaptor for checking current probes. 0.1 to 100 mA, 0.2 % accuracy. Due to continuous development Time Electronics reserves the right to change specifications without prior notice.
Time Electronics Ltd, Unit 5, T O N Business Park, 2-8 Morley Road, T onbridge, Kent, TN9 1RA, United Kingdom T : +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com v6b General specification
Ordering Information
Due to continuous development Time Electronics reserves the right to change specifications without prior notice.