Echotel® Model 961/962 Ultrasonic Level Switches D E S C R I P T I O N Increasing demands for compliance with safety systems and overfill protection has mandated more reliable point level measurement. Echotel® Models 961 & 962 Ultrasonic Level Switches meet these demands with advanced trans- ducer designs, extensive hazardous location approvals, and a new self-test technology. Model 961 offers the ultimate solution to reliable single point liquid level measurement. This advanced switch uses pulsed signal technology for superior performance in difficult process conditions, and to provide excellent immunity from sources of electrical noise interference. Extensive self-testing of the electronics and transducer make this advanced switch suitable for use in Safety Integrity Level (SIL) 2 loops. Model 962 is a dual point switch that can be used as a level controller, or to control pumps in an auto fill or auto empty mode. The tip sensitive lower gap performs well in aerated or foamy liquids, and can measure to within 1⁄4 " of the vessel bottom. The rigidity of the unique flow-through upper gap allows separations of up to 128" (325 cm) between the upper and lower transducer gaps. F E A T U R E S
- Single or dual point liquid level measurement
- Advanced self-test technology provides unsurpassed testing of electronics, transducer, piezoelectric crystals, and electromagnetic noise
- Adjustable time delay for turbulent aerated liquids
- Relay output or mA current shift with separate malfunction indication
- Integral or remote mount electronics
- Pulsed signal technology
- Extensive FM, CSA, and ATEX explosion proof and intrinsically safe approvals
- Suitable for Safety Integrity Level (SIL) 2 loops Model 961 Model 962 A P P L I C A T I O N S
- High level alarm
- Low level alarm
- Overfill protection
- Pump protection
- Seal pot level
- Pump control I N D U S T R I E S
- Chemical
- Petrochemical
- Pulp and paper
- Food and pharmaceutical
- Power
- Water and wastewater
P U L S E D S I G N A L T E C H N O L O G Y Cha llenging process conditions such as aeration, suspended solids, and high viscosities are easily handled with the pulsed signaltechnology utilized in the 961/9 62 switches.Pulsed signalcircuitry drives the transmit piezoelectric crystal to produce powerful pulsesof high-frequency ultrasonic energy. These ultrasonicpulses are readilytransmitted through liquids,but are attenuated when the transducer gap isdry.Thistechnology also providesexcellentimm u - nityfrom electrom agneticnoise interference. Pulsed signaltechnology m akes the 961/962 units m ore reliable than older continuous w ave ultrasonicswitches. Un like ma ny tuning forks, pulsed signal ultrasonic switches do notneed to be configured for differentm edia densities,mak ing these units the m ostuniversallyapplied levelsw itches on the m arkettoday. Mod el961/962 switchesutilizeultrasonicenergy todetect thepresence or absence ofliquid ina singleordualpoint transducer.Ultrasoniccontactleveltechnology useshigh- frequency sound waves thatare easilytransmittedacross a transducer gap in the presence of a liquid med ia,but are attenuated when the gap is dry.Mo del 961/962 switches use an ultrasonicfrequency of2 M Hz to perform thisliquid levelmeasurement in a wide varietyofprocess med iaand applicationconditions. The transducerusesa pairofpiezoelectriccrystalsthatare encapsulated in epoxy at the tip of the transducer.The crystalsare made of a ceramicm aterialthat vibrates ata given frequency when subjectedto an appliedvoltage. The transmitcrystalconvertsthe appliedvoltage from the electronicsintoan ultrasonicsignal.When liquidispresent inthegap,thereceivecrystalsensestheultrasonicsignal from the transmitcrystaland convertsitback to an elec - tricalsignal.Thissignalissentto the electronicsto indi - cate the presence of liquidin the transducer gap.When thereisno liquidpresent,the ultrasonicsignalisattenu - atedand is not detectedby thereceivecrystal. Ultrasonic transducer Transmit crystal Receive crystal Ultrasonic signal transmission across transducer gap T E C H N O L O G Y B A S I C O P E R A T I O N S A F E T Y I N T E G R I T Y L E V E L ( S I L ) Criticalprocesscontrolapplications demand reliableinstru - me ntsthatprovidehighlevelsofsafety.The introduction of standardssuch as IEC 61508, IEC 61511 and ISA 84, have generated interestin using Safety Instrumen ted Systems (SIS) as a mea ns to definethe reliability of instrume nts in a control loop. All versions ofthe Mo del961/962 switches undergoa detailed performance evaluation called a FailureM odes,Effectsand Diagnostics A nalysis(FMEDA ).Three key componen ts of the FMEDA are the SafetyIntegrityLevel(SIL),Safe Failure Fraction (SFF)and the average Probability of Failureon Dem and (PFDavg).
961 R elay 961 C urrentShift 962 R elay 962 C urrentShift
SIL 2 as 1oo1 2 as 1oo1 2 as 1oo1 2 as 1oo1 PFD avg 1.77E- 04 1.61E-04 2.31E-04 1.87E- 04
A D V A N C E D S E L F - T E S T A N D D I A G N O S T I C S Ultrasonic switches areoftenused as the last m eans of detecting whe ther a processvesselwilloverflow and cause a spillof potentially hazardous liquids,or em pty out and possibly cavitate the pum ps.In these criticalapplications itis desirable to have a method of periodicallytesting the ultrasonicswitch toensure thatitisfunctioning properly. M odel 961/962 sw itches feature an advanced self-test technology thatnot onlyteststhe electronics,transducer, and piezoelectriccrystals,but also testsfor the presence of industrialsources of environmentalnoise.Should the switch detectany problems a malfunctionoutputisgen - erated to alarm the user,and a red LED islitto indicate an alarm condition. Self-testisperformed automaticallyand continuously sev - eral times per second to verify proper operation of 961/962 switches.In addition,a pushbutton isprovided to initiatea manual self-testm ode.Pressingthistestbutton stops alltransmitpulses,which simulates an electronics failure.Thisfailureisreportedas:
- 3.6or 22 mA (selectable)withcurrentshiftoutput units
- SPDT malfunction relay de-energizeswith relay outputunits Taking diagnostics one step further isthe unique noise self-test m ode feature that is standard in all 961/962 switches. This tests for electrom agnetic and acoustical noise thatcan influence m any instrumentation technolo - gies.If high levelsof environm entalnoiseare detected, the electronics reports a fault condition to alert the user ofpotentialinstrum entation reliability concerns. A m icroprocessor in the 961/962 electronicscontinuously m onitors allself-testdata.Shoulda faultoccur,the m icro - processor can determine wh ether the malfunction is due to the electronics,transducer,piezoelectric crystals,or the presence ofenvironmen talnoise.A pushbutton and Fault LED isused to assistintroubleshootingtheswitch:
5 One flashoftheFaultLED indicates a problem
withthetransduceror piezoelectric crystals
55 Tw o flashes ofthe FaultLED indicatesa
problem w ith one of the electronicsboards
555 Three flashes ofthe FaultLED indicates
excessivelevelsofenvironm entalnoise Transducer & crystals Electronics Noise A D J U S T A B L E T I M E D E L A Y Turbulence and splashing can cause som e fixed time response switches to produce false level alarms . Mode l 961/962 switches overcome this difficulty with an adjustable time delay feature. A potentiom eterallows a 1⁄2 to 45 second delayto be set to disregard waves or splashes,and reliably detect the true liquid level. R E L I A B L E T R A N S D U C E R D E S I G N Dep endable point level m easurement begins w ithreliable sensor design.Over 30 yearsof ultrasoniclevel switch tech - nology experience isbehind the Mode l 961/9 62 single and dual gap transducers. The result is an extremely robust trans - ducerdesign thatofferssuperiorperform - ance in difficultprocess conditions. M odel961 single pointhas a tip-sensitivetransducerw ith an arch-shaped gap for superior perform ance in aerated orfoam y liquids.Du alpointM odel962 featuresa tip sen - sitivelow ergap and flow through uppergap.This robust designallow s separations of125 inches(318 cm) betw een the upper and lower transducergaps.
Model 96 1 singlepointswitches may be used forhigh or low levelalarm, aswellas forpump protection.The Mode l 96 2 dual point unit is typicallyconfiguredto me asure high/low,high/high,or low/low levels. The singlepoint 961 can be mounted vertically or horizontallyinvessels,bridles,or pipes.The dualgap 96 2 is alwa ys top mounted. A broad selectionoftransducermaterialsallowthe96 1/962 to be used in a wide varietyof process media.Metallic transducersinclude316 SS,H astelloy ® C, and Mone l ® .The
316 SS transducerhas a NAC E constructionoptionforsour
gas service,and can alsobe builtper ASME B31.1and B31.3 piping codes.Thermoplastictransducersinclude Kyna r ® and C PVC .These corrosion resistantplastic trans - ducersfeaturea stiffeningtube thatrunsthelengthof the transducer for extrarigidity.K ynar-faced 316 SS flange optionsareoffered withtheKy nar transducers. P U M P C O N T R O L A D IP switchon theModel 9 62 allow s itto be configured tocontrollevel,ortofunction asa pump controller.In the pum p controlmode theunitcan perform autofillor auto em pty of tanks,sumps, or w et wells.The tipsensitive lower gap allows liquidlevels to be pump ed down to within 1⁄4"from the bottom ofthevessel.The rigidityofthe flow through upper gap allows the 962 to be used even wh en sum ps experiencesevere turbulence from vessel filllines. H Y G I E N I C The hygienicversionof the Mode l 961 featuresa deep drawn stainless steel electronicshousing.Tri-Clamp ® and DN 65 Variventhygienicprocessconnectionsareoffered for use in food & beverage,pharmaceutical,and biotechnology applications.These hygienic transducers have 3-A (Authorization#59 6),EHEDG certification(perTN O Report # V4772/01) and a 20 Ra finishto provide a uniformand ultra-smooth surface that inhibits microbial growth. Electron beam weldingtechnology isutilized tofacilitatea crevice-free surfaceinsidethe transducer tip.Thisallows these transducerstobe used ina wide varietyof hygienic applicationswhere CIP (Clean-in-Place) isused toremove any contaminationfrom thetransducersurface.
E L E C T R O N I C S S P E C I F I C A T I O N S M O D E L 9 6 1 / 9 6 2 W I T H R E L A Y O U T P U T SupplyVoltage 18 to32 VDC ,or102 to265 VAC ,50/60H z R elayOutputs 96 1: One DPDT levelrelayand one SPDT malfunctionrelay 96 2: Two SPDT levelrelays and one SPD T ma lfunctionrelay R elayR atings DPDT: 5 amps @ 120 VAC, 250 VAC, and 30 VDC,0.4 amp @ 110 VDC SPD T: 5 am ps @ 120 VAC ,250 VAC, and 30 VDC,0.15 amp @ 125 VDC Fail-safe Selectableforhighorlow level Pow erConsum ption 96 1/9 62: Less than 3 watts Am bientTempe rature -40° to+160°F (-40°to+70° C) M O D E L 9 6 1 / 9 6 2 W I T H C U R R E N T S H I F T O U T P U T SupplyVoltage 11 to35 VDC Cu rrentShiftO utput 96 1: 8 mA normaloperation,16 mA levelalarm ( ±1 mA) 96 2: 8 mA normal operation,12 mA lowergap alarm,16 mA uppergap alarm(±1mA ) 96 1/9 62: 3.6 m A or22 mA selectablefaultsignal( ±1 mA) Loop R esistance 104 ohms with11 VDC input,1100 ohms with35 VDC input Fail-safe Selectableforhighorlow level Pow erConsum ption 96 1/9 62 Less than 1 watt Am bientTempe rature -40° to+160°F (-40°to+70° C) T R A N S D U C E R S P E C I F I C A T I O N S M O D E L 9 A 1 / 9 M 1 S I N G L E P O I N T TransducerMaterial MaterialCode (page10) OperatingTemperatureRange Maximum Pressure ActuationLength
316 StainlessSteel A*,S,N,K -40° to+325°F (-40°to+163° C) 2000 psi(138bar) 1"and 2" (3and 5 cm)
316 StainlessSteel A*,S,N,K -40° to+325°F (-40°to+163° C) 1500 psi(103bar) 3"to130" (6to330 cm)
HastelloyC-276 B -40° to+325°F (-40°to+163° C) 2000 psi(138bar) 1"and 2" (3and 5 cm) HastelloyC-276 B -40° to+325°F (-40°to+163° C) 1500 psi(103bar) 3"to130" (6to330 cm) Monel C -40° to+325°F (-40°to+163° C) 1200 psi(83bar) 1"to130" (3to330 cm) Kynar R -40° to+250°F (-40°to+121° C) see graph below 2"to130" (5to330 cm) CPVC P -40° to+180° F (-40°to+82° C) see graph below 1"to130" (3to330 cm) TransducerMaterial MaterialCode (see page 10) OperatingTemperatureRange Maximum Pressure ActuationLength
316 StainlessSteel A,K -40° to+325°F (-40°to+163° C) 1500 psi(103bar) 5"to130"(13to330 cm)
CPVC P -40° to+180° F (-40°to+82° C) see graph below 5"to130"(13to330 cm) 300 250 200 150 100 -40 0 60 120 180 240 Pressure (psi) Temperature (°F) -40 0 40 80 120 Pressure (bar) Temperature (°C) Range with PN16 flange Range with 150# flange Range with "NPT 300 250 200 150 100 -40 0 40 80 120 160 200 Pressure (psi) Temperature (°F) -40 0 40 80 120 Pressure (bar) Temperature (°C) Kynar Transducer Ratings CPVC Transducer Ratings *MaterialCode “A” has a CryogenicTrandsucerOptionfor-110°to+250°F (-80°to+120°C)operatingtemperaturerange M O D E L 9 A 2 / 9 M 2 D U A L P O I N T
P E R F O R M A N C E S P E C I F I C A T I O N S R epeatability ±0.078" (2mm ) R esponse Time 1⁄2 second typical Time Delay Variable 0.5– 4 5 seconds on risingand fallinglevels Self-Test Au tomatic: Co ntinuouslyverifiesoperation ofelectronics,transducer, piezoelectriccrystals,and electricalnoise Ma nual: Push buttonverifiesoperation ofelectronics,transducer, and piezoelectriccrystals Sho ck Class ANSI/ISA-S71 .03ClassSA1 Vibration Class ANSI/ISA-S71 .03ClassVC2 Humid ity 0 – 99%, non-condensing ElectromagneticCo mp atibility Me etsCE requiremen tsEN 61326 P H Y S I C A L S P E C I F I C A T I O N S Ho usingMa terial Cast alum inum A356-T6,cast316 stainlesssteel, ordeep draw n 304 stainless steel(hygienichousing) Cable Entry Dual3⁄4 "N PT,orM20 connections (one end isplugged) Gross Weight 961/9 62 Electronics: 2.2lbs.(1.0 kg) 2"(5cm )Transducer: 0.6lbs.(0.3 kg) Mo del961 with HygienicHou sing withTri-Clam p ® 16-AMP Fitting M odel961 with C astAluminum Hou sing withNPT Co nnection Mo del961 withCast StainlessSteel Hou singand ANSI Flange 1.8 (46) Typical1.05 (26) Typical 4.00 (102)4.00 (102) Actuation length for Tri-Clamp fitting 4.43 (113) 4.43 (113) Actuation length for NPT connection Actuation length for ANSI flange 2.35 (60) Typical 5.24 (133) 5.75 (146) D I M E N S I O N A L S P E C I F I C A T I O N S I N C H E S ( m m )
D I M E N S I O N A L S P E C I F I C A T I O N S I N C H E S ( m m ) Actuation length A Actuation length B ∅ .875 (22) Dia. 4.00 (102) 4.43 (113) 1.8 (46) Typical 0.25 (6) 3.50 (89) 2.75 (70) 2.00 (51) 3.00 (76)
2 Holes
.38 (10) dia. 4.00 (102) 4.00 (102) 3.95 (100) 4.43 (113) ¾" NPT Conduit Connection ∅ .875 (22) 0.25 (6) Actuation length for NPT connection 1.8 (46) Typical Mo del961/962 with Re mot e Electronics Remote Transducer withNP T Co nnection Mo del962 withNPT Con nection Actuation length A Actuation length B ∅ .875 (22) Dia. 4.00 (102) 4.43 (113) 2.35 (60) Typical 0.25 (6) Mod el962 withANSI Flange
9 61 Single-pointelectronics 9 62 D ual-pointelectronics M O D E L N U M B E R 9 6 1 / 9 6 2 E L E C T R O N I C S B A SIC M ODEL N UMBER 2 18 to 32 VDC line-powered 5 11 to 35 VDC loop-powered 7 102 to 265 VAC line-powered IN PUT POWE R 0 m A currentshift(availablew ithInput Power code 5) D 5-amp goldflashrelays(availablewith InputPower codes 2 or 7) OU TPU T SIGN A L
0 Integral
1 Rem ote(requiresConnec tingCable from page 11)
1 FM/CSA Intrinsicallysafe,Non-Incendive
& Explosion Proo f*(use w ithcurrent shift Outp ut Signal code 0 )
3 FM/CSA Explosion Proof& No n-Incendive
(use with relay Output Signalcod e D , and Electronics Hous ingcodes 0,1,2 & 3)
7 FM/CSA N on-incendive (availablewith OutputSignal
codes 0 & D and Electronics Hous ingcodes 4 & 5) A ATE X II1G EEx iaIIC T5, Intrinsicallysafe (use with OutputSignalcode 0,and Electronics Hou sing codes 0,1,2,3) C ATE X II1/2G EEx d IIC T6,Flameproof (use with OutputSignalcode 0 or D,and Electronics Ho usingcodes 0,1,2,3) AGE NCY A PPROVA L
0 C astalum inum with 3⁄4"NP T dualconduitentries
1 C astalum inum with M20 dual conduitentries
2 C astSS w ith3⁄4"NP T dualconduitentries
3 C astSS w ithM20 dual conduitentries
4 Deep drawn SS with 1⁄2"N PT dualconduitentries
5 Deep drawn SS with M 20 dualconduitentries
Mo delsavailablefor quick shipment,usuallywithinone week afterfactory receiptofa com pletepurchase order,through theExpediteShip Plan (ESP) 96 A
0 Standard housingcover
1 Glass window cover (availablewith ElectronicsHo usingcodes 0,1,4 or 5)
*Explosion Proofapprovals notavailablewithhousing codes 4 & 5
9 6 1 S I N G L E P O I N T T R A N S D U C E R A English (length ininches) M Metric(length incentimeters) TRA NS DU CER U NI T OFLENGTH A 316/316Lstainlesssteel S 316/316Lwith 20 Ra hygienicfinish(useonly with ProcessConnection codes 3T,4T,or VV) B H astelloy C -276 C M onel R K ynar *(use onlywith ProcessConnection codes 11,23,33,43,BA, CA, DA) P CP VC (use only with ProcessConnection codes 11,23,33,43,BA, C A ,DA ) N 316/316Lstainlesssteel,NACE construction K 316/316Lstainlesssteel,ASME B31.1&B31.3construction MA TERIA LS OFC ONST RUC TION PROC ESS C ONNE CT IONS 11 3⁄4"NPT 21 1"NP T 22 1"BS P (G1) THR EA DED CO NNE C TIONS 23 1"150# A NSI RF flange 24 1"300# A NSI RF flange 25 1"600# A NSI RF flange 33 11⁄2"150# A NS I RF flange 34 11⁄2"300# A NS I RF flange 35 11⁄2"600# A NS I RF flange 43 2"150# A NSI RF flange 44 2"300# A NSI RF flange 45 2"600# A NSI RF flange AN SI RAISED FAC E FLA NGE S 3T 11⁄2"Tri-Clam p ® 16 A M P fitting 4T 2"Tri-Clam p ® 16 A M P fitting VV DN65 – Varivent ® Type N HY GIENI C C ONNE CT IONS B A DN 25 PN 16 EN 1092-1Type A B B DN 25 PN 25/40 EN 1092-1Type A B C DN 25 PN 63/100EN 1092-1Type B2 CA DN 40 PN 16 EN 1092-1Type A CB DN 40 PN 25/40 EN 1092-1Type A CC DN 40 PN 63/100EN 1092-1Type B2 DA DN 50 PN 16 EN 1092-1Type A DB DN 50 PN 25/40 EN 1092-1Type A DD DN 50 PN 63 EN 1092-1Type B2 DE DN 50 PN 100 EN 1092-1Type B2 EN/DIN FLANGE S M odelsavailablefor quick shipment,usuallywithinone week afterfactory receiptofa com pletepurchase order,throughtheExpediteShip Plan (ESP) 1"to 130"in1"increm ents(Examp le:4 inches= 004) 1"m inimu m for NPT process connections 2"m inimu m for B SP,hygienic,and flanged processconnections 2"m inimu m for allK ynartransducers AvailableEnglish ESP lengths:1",2",4",6",8",12" 3 cm to 330 cm in1 cm increm ents(Exam ple:6 centimeters= 006) 3 cm m inimum for NP T process connections 5 cm m inimum forBS P,hygienic,and flangedprocessconnections 5 cm m inimum forallKy nartransducers Availablem etricESP lengths:3,5, 10,30 cm AC TUAT ION LENGT H* ( unitoflength specifiedin second digit) *Flanged K ynartransducershave Kyn arfaced316 stainlesssteelflanges *Forlengths longerthan 130"(330 cm),contactthe factory A Standard design C Cryogenic designto-110 ° F(-80 ° C) (available w ith Materials code A) TRANSDUC ER OPTIONS
9 6 2 D U A L P O I N T T R A N S D U C E R 92 A A English (length ininches) M Metric(length incentimeters) TRA NS DUC ER UN IT OFLENGTH A 316/316Lstainlesssteel K 316/316Lstainlesssteel,ASME B31.1&B31.3construction P CP VC (use only with ProcessConnection codes 11,23,33,43,BA, C A ,DA ) M A TERIALS OFCO NSTRUC TION 11 3⁄4"NP T 21 1"NP T 22 1"BS P (G1) THREA DED CO NNEC TIONS 5" to 130"in1"increm ents 5" minimu m for NP T processconnections 6"minimu m for B SP,and flanged processconnections Exam ple:5 inches = 005 13 cm to 330 cm in1 cm increments 13 cm m inimum for NP T process connections 15 cm minimum forB SP,and flanged processconnections Exam ple:13 centimeters = 013 “A ” DIME NSION A C TUAT ION LENGT H* ( units specified insecond digit) PROC ESS C ONNE C TIONS Actuation length A Minimum distance between actuation points A and B is 3" (8 cm) Maximum distance between actuation points A and B is 125" (318 cm) Actuation length B min. 2" (5 cm) Important: U se the “A ” dimensionas the actuation length code. The “B ” dimension must also be specifiedinquote/order. Example: For a 962 with an “A” dimension of18" and a “B” dimension of7",specify actuation length code 018. 23 1"150# A NSI RF flange 24 1"300# A NSI RF flange 25 1"600# A NSI RF flange 33 11⁄2"150# A NS I RF flange 34 11⁄2"300# A NS I RF flange 35 11⁄2"600# A NS I RF flange 43 2"150# A NSI RF flange 44 2"300# A NSI RF flange 45 2"600# A NSI RF flange A N SI RAISED FAC E FLANGE S B A DN 25 PN 16 EN 1092-1Type A B B DN 25 PN 25/40 EN 1092-1Type A B C DN 25 PN 63/100EN 1092-1Type B2 CA DN 40 PN 16 EN 1092-1Type A CB DN 40 PN 25/40 EN 1092-1Type A CC DN 40 PN 63/100EN 1092-1Type B2 DA DN 50 PN 16 EN 1092-1Type A DB DN 50 PN 25/40 EN 1092-1Type A DD DN 50 PN 63 EN 1092-1Type B2 DE DN 50 PN 100 EN 1092-1Type B2 EN/DIN FLA NGE S *For lengths longerthan 130"(330 cm ),contactthefactory
A G E N C Y A P P R O V A L S AGE NC Y APPR OVE D MO DE LS PROTEC TION M ETH OD AR EA C LAS SIFICATION FM & CS A 96X- X0A0-X10 ExplosionProof ClassI,Div.1,GroupsB,C,& D 96X- X0A0-X11 ClassII,Div.1,Groups E,F ,& G 96X- X0A0-X12 ClassIII,Type 4X ,IP 66,T6 96X- X0A0-X13 96X- X0A1-X10 96X- X0A1-X11 96X- XDA 0-X30 96X- XDA 0-X31 96X- XDA 0-X32 96X- XDA 0-X33 96X- XDA 1-X30 96X- XDA 1-X31 with transducers 9AX -XXXX -XXX or 9MX -XXXX -XXX 96X- XXAX -XXX or Non-Incendive ClassI,Div.2,Groups A,B,C,& D with transducers ClassII,Div.2,Groups E,F ,& G 9AX -XXXX -XXX or ClassIII,Type 4X ,IP 66,T4 9MX -XXXX -XXX 96X- 50A X-X1X IntrinsicallySafe ClassI,Div.1,Groups A,B,C,& D with transducers ClassII,Div.1,Groups E,F ,& G 9AX -XXXX -XXX or ClassIII,Type 4X ,IP 66,T4 9MX -XXXX -XXX ATEX 96X- XXAX -XC0 Flameproof Ex II 1/2 G, EEx d IIC T6 96X- XXAX -XC1 96X- XXAX -XC2 96X- XXAX -XC3 with transducers 9XX- A XXX -XXX 9XX- SXXX -XXX 9XX- BXXX-XXX 9XX- C XXX-XXX 9XX- N XXX-XXX 9XX- K XXX-XXX 96X- 50A X-XA 0 IntrinsicallySafe Ex II 1 G, EE x ia IIC T5 96X- 50A X-XA 1 96X- 50A X-XA 2 96X- 50A X-XA 3 with transducers 9XX- A XXA -XXX 9XX- SXXA -XXX 9XX- BXXA-XXX 9XX- C XXA-XXX 9XX- N XXA-XXX 9XX- K XXA-XXX M O D E L N U M B E R C O N N E C T I N G C A B L E M aximum Length:150 feet Minimum Length:10 feet Exam ple:12 feet= 012 C ONNE CT ING C A B LE LENGT H (FEET) 037 331
6 Rem otecableforModel 961
7 Rem otecableforModel 962
These units are in compliance with: 1. The EMC Dir ective: 89/336/EEC. The units have been t ested to EN 61326. 2. Directive 94/9/EC for equipment or protective system for use i npotentially explosive atmospheres. 0344
BULLETIN: 51-137.3 EFFECTIVE: August 2011 SUPERSEDES: November 2009 The quality assurance system in place at Magnetrol® guarantees the highest level of quality throughout the company. MAGNETROL is committed to providing full customer satisfaction both in quality products and quality service. The MAGNETROL quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product and service quality available. Several ECHOTEL Model 961 units are available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, simply match the color coded model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representa- tive for lead times on larger volume orders, as well as other products and options. EExpedite SShip PPlan All MAGNETROL electronic level and flow controls are warranted free of defects in mate- rials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, MAGNETROL will repair or replace the control at no cost to the purchaser (or owner) other than transportation. MAGNETROL shall not be liable for misap- plication, labor claims, direct or consequen- tial damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some MAGNETROL products. 5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com
145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306
Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317 Copyright © 2011 MAGNETROL INTERNATIONAL, INCORPORATED. All rights reserved. Printed in the USA. Performance specifications are effective with date of issue and are subject to change without notice. For additional information, see Instruction Manual 51-646. Q U A L I T Y E S P W A R R A N T Y MAGNETROL, MAGNETROL logotype and ECHOTEL are registered trademarks of MAGNETROL INTERNATIONAL, INCORPORATED. Kynar® is a registered trademark of Elf Atochem North America, Inc. Hastelloy® is a registered trademark of HAYNES INTERNATIONAL, INC. (DELAWARE CORPORATION). Monel® is a registered trademark of the INCO family of companies. Tri-Clamp® is a registered trademark of Ladish Co. Varivent® is a registered trademark of Tuchenhagen GmbH LTD