Echote l® Models 960/961 U ltrasonicLevelSwitches forHygienicApplications D E S C R I P T I O N Echotel ® M odel 960/961 U ltrasonic Level Sw itchesuse pulsed signal technology for superior performance in difficult process conditions, and to provide excellent imm unity from sources of electricalnoise interference. Extensive self-testingof the electronics and transducer m ake this advanced switchsuitablefora wide varietyof hygieniclevelswitchapplications. M odel 960 Sw itches use A S-Interface ® (AS-i)bus digital comm unicationsforhigh or low singlepointliquid level measurement.The AS -ibus system providesa digitalserial interface w ith a single unshielded two-wire cable for power and data transfer. M odel961 isofferedwith either a 5-amp relayor a cur - rent shift electronics.The relay output electronicshas a DPDT relayforleveldetection,and a SPDT m alfunction relay.The currentshiftversion indicates 8 m A duringnor - m al operation,16 mA as a level alarm condition and a user-selectable 3.6 or 22 mA m alfunction indication. The 960/961 switches are designed for the stringent requirements ofhygienic applications.These switches are offeredw itha deep-drawn 304 stainlesssteelhousingthat isfavorable to CIP and SIP procedures.A 20 R a surface finish isfeatured w ithhygienicMod el960/961 transducers. These transducers are available with 1 1⁄2" & 2" Tri-Clamp ® fittings,and DN65 Varivent ® Type N flanges. F E A T U R E S

  • Self-testtechnology provides unsurpassed reliability and testing ofelectronics,transducer, piezoelectriccrystals, and electromagn eticnoise
  • 20 R a surface finishwithTri-Clamp and Variventfittings
  • Ad justabletimedelay for turbulentaerated liquids
  • Tip-sensitivetransducer measures levelw ithin 1⁄4"of thevesselbottom
  • Pulsedsignaltechnologyprovides superior perform - ance indifficultprocessconditions A P P L I C A T I O N S
  • Hig h or low levelalarm
  • CIP buffer tanks
  • W FI system s
  • Hyg ienic pum p protection
  • Beervats
  • Leak detection
  • Liquidchrom atography skids
  • O verfillprotection I N D U S T R I E S
  • Bio-technology
  • Chem ical
  • Brewing and spirits
  • Food and beverage
  • Pharmaceutical Model 960/961 (withTri-Clamp fitting) Model 960/961 (withVarivent fitting)

Mode l9 60/96 1 switches use pulsed signal technology to detect the presence or absence of liquid in an ultrasonictrans - ducer gap. The transducer uses a pairof piezoelectric crystals that vibrate at a given frequency w hen subjected to an appliedvoltage. The transmitcrystalconvertstheappliedvoltagefrom the electronicsintoan ultrasonicsignal.When liquidispresent inthe gap,thereceivecrystalsenses theultrasonicsignal and convertsitback intoan electricalsignal.Thissignalis sentto the electronics to indicate a wet gap condition. When no liquidispresent,the ultrasonicsignalisattenu - ated and isnot detectedby thereceivecrystal . Challenging process conditions like aeration, suspended solids,and high viscositiesare overcome by using pulsed sig - nalcircuitry in96 0/961 switches.Un like many tuning forks, pulsedsignalultrasonicswitches do not need to be config - ured for different media densities,making these unitsthe mo stuniversally appliedlevelswitches on themarkey today. Ultrasonic transducer Transmit□ crystal Receive crystal Ultrasonic signal transmission□ across transducer gap P U L S E D S I G N A L T E C H N O L O G Y A D V A N C E D S E L F - T E S T A N D D I A G N O S T I C S Ultrasonicswitches are often used as the last m eans of detecting whe ther a processvesselw illoverflow and cause a spillof potentially hazardous liquids,or empty out and possibly cavitate the pump s.In thesecriticalapplications itis desirable to have a method of periodicallytesting the ultrasonic switch toensurethatitis functioning properly. Mod el 96 0/961 switches feature an advanced self-test technology thatnot only teststhe electronics,transducer, and piezoelectric crystals,but also tests for the presence of industrialsources of environmental noise.Should the switchdetectany problems a m alfunction outputis gen - erated to alarm the user,and a red LED islitto indicate an alarm condition. A microprocessor inthe 960/ 961 electronics continuously m onitors allself-testdata.Shoulda faultoccur,the micro - processor can determine w hether the malfunction isdue tothe electronics,transducer,piezoelectriccrystals,orthe presence ofenvironm entalnoise.A pushbutton and Fault LED is used to assistintroubleshooting the switch:

5 One flash oftheFaultLED indicatesa problem

withthetransduceror piezoelectriccrystals

55 Tw o flashes ofthe FaultLED indicates a

problem with one ofthe electronicsboards

555 Three flashes ofthe FaultLED indicates

excessive levelsofenvironm entalnoise Transducer & crystals Electronics Noise A D J U S T A B L E T I M E D E L A Y Turbulence and splashing can cause some fixed time response switches to produce false level alarms . Model 960/ 9 61 switches overcome this difficulty with an adjustable time delay feature. A potentiom eter allows a 1⁄2 –45-second delayto be setto disregard w aves or splashes,and reliablydetectthe true liquidlevel.

A G E N C Y A P P R O V A L S AGE NC Y APPR OVE D MO DE LS PROTEC TION M ETH OD AR EA C LAS SIFICATION FM & C SA 960-58AX- 030 Explosion Proof ClassI,Div.1,Groups B, C,& D 960-58AX- 031 ClassII ,Div.1,Groups E,F ,& G 961-50AX-010 ClassIII ,Type 4X,IP 66,T6 961-50AX-011 961-XDAX-030 or 961-XDAX-031 with transducers: 9X1-XXXX-XXX 960-58AX- 074 No n-Incendive ClassI,Div.2,Groups A,B, C,& D 960-58AX- 075 ClassII ,Div.2,Groups F & G 961-XXAX-01X ClassIII ,Type 4X,IP 66,T4 961-XXAX-03X or IP67 for304 StainlessSteelHousing 961-XXAX-07X with transducers: 9X1-XXXX-XXX 961-50AX-01X IntrinsicallySafe ClassI,Div.1,Groups A,B, C,& D with transducers: ClassII ,Div.1,Groups E,F ,& G 9X1-XXXX-XXX ClassIII ,Type 4X,IP 66,T4 ATEX 960-58AX- 0C 0 Flameproof ExII 1/2G, EExd II C T6 960-58AX- 0C 1 961-XXAX-0C0 961-XXAX-0C1 with allm etallic transducers* 961-50AX-0A0 IntrinsicallySafe ExII 1 G, EExiaII C T5 961-50AX-0A1 with allm etallic transducers* AS - i These unitshave been tested toAS-Interface Specification EN50 295 and IEC 62026-2 ,and have me tthedema nds ofthe AS-Interface TestRequirements.AS-Interface certificate #76401 *Co nsult factory formode lnumb ers Mo del 960/961 Switchesmay be used forhigh or low levelalarm,empty pipedetection and pump protectionin a wide varietyof hygienic applications.A vailable w itha 304 stainless steelelectronicshousing and a 20 R a surface finish transducer,typicalapplications include:

  • CIP/SIP day tankpointlevel
  • Wa ter forInjection(WFI)storage
  • Liquidchromatography skids
  • Breweryfilllines
  • Condensate receivertanks These units have been tested to EN 61326 and are in compliance with the EMC Directive 89/336/EEC.

E L E C T R O N I C S S P E C I F I C A T I O N S M O D E L 9 6 0 W I T H A S - I n t e r f a c e Sup plyVoltage 21 to31 VDC AS -iVersion V 3.0 AS -iSlaveType A/B (Maximum of62 nodes) AS -iSlaveProfile S-0.A.E AS -iData Bits Ga p C ondition: D2 = 1 witha we tgap D2 = 0 w itha dry gap Ma lfunction Status: D3 = 1 duringmalfunction D3 = 0 in norma lstate Co nnectableLoad EN50 295 and IEC 62026-2 Pow erConsum ption Less than1 wa tt Am bientTem perature Electronics: -13 ° to+160 ° F (-25 ° to+70 ° C) Storage Tempe rature Electronics: -40 ° to+160 ° F (-40 ° to+70 ° C) T R A N S D U C E R S P E C I F I C A T I O N S M O D E L 9 6 1 W I T H R E L A Y O U T P U T Sup plyVoltage 18 to32 VD C,or102 to265 VAC, 50/60 H z RelayOutputs One D PDT levelrelayand one SPD T malfunction relay RelayRatings D PDT: 5 amps @ 120 VAC, 250 VAC ,and 30 VD C,0.4amp @ 110 VDC SPD T: 5 am ps @ 120 VAC ,250 VAC, and 30 VD C,0.15 amp @ 125 VDC Fail-safe Selectableforhigh orlow level Pow erConsum ption Less than 3 watts Am bientTem perature -40°to+160° F (-40° to+70° C) M O D E L 9 6 1 W I T H C U R R E N T S H I F T O U T P U T Sup plyVoltage 11 to35 VD C CurrentShiftOutput 8 mA normaloperation,16 m A levelalarm ( ±1 mA) 3.6 m A or22 mA selectable faultsignal( ±1 mA) Loop Resistance 104 ohms with11 VDC input,1100 ohms with35 VDC input Fail-safe Selectableforhighorlow level Pow erConsum ption Less than 1 watt Am bientTem perature -40°to+160° F (-40° to+70° C) Op eratingTemperature -40°to+325° F (-40° to+163° C) Max imum Pressure 1" and 2": 2000 psi(138 bar) 3" to 130" : 150 0 psi(103 bar) Op eratingFrequency 2 MHz Surface Finish 20 R a (when orderedw ith4thdigitcode S)

P E R F O R M A N C E S P E C I F I C A T I O N S Repeatability ±0.078" ( ± 2 mm) Response Time 1⁄2 second typical Time D elay Variable0.5 – 45 seconds on risingand fallinglevels Self-Test Au toma tic: Co ntinuously verifiesoperation ofelectronics,transducer, piezoelectriccrystals,and electricalnoise Man ual: Push buttonverifies operation ofelectronics,transducer, and piezoelectric crystals Shock Class ANSI/ISA-S71.03ClassSA1 Vibration Class ANSI/ISA-S71.03ClassVC2 Hu midity 0-99%,non-condensing Electromagn eticCo mp atibility Meets CE requirementsEN 61326 P H Y S I C A L S P E C I F I C A T I O N S Ho usingMa terial Cast aluminum A356 -T6,ordeep drawn 304 stainlesssteel Cab leEntry C astAluminum : D ual3⁄4" N PT,orM2 0

304 StainlessSteel: D ual1⁄2" N PT,orM2 0

withDN65 Varivent ® Flange 1.80 (46) Typical 2.70 (69) Typical 4.00 (102) ∅ .875 (22) ∅ .875 (22) Actuation length with Varivent fitting 4.43 (113) 0.25 (6) 0.25 (6) Actuation length with NPT connection 1.05 (26) Typical ∅ .875 (22) Actuation length with Tri-Clamp fitting 0.25 (6) 5.24 (133) 5.75 (146) 5.24 (133) 5.75 (146) D I M E N S I O N A L S P E C I F I C A T I O N S I N C H E S ( m m ) M odel960/961 withTri-Clamp ® fitting Mo del960/961 w ith NPT Con nection

960 Actuator-Sensor-Interface (AS-i)electronics

961 Relay or currentshiftelectronics

9 6 0 / 9 6 1 E L E C T R O N I C S BA SIC M ODEL NU MB ER 2 24 VDC line-powered (Model 961 only) 5 24 VDC loop-powered (Model 960 & 961) 7 102 to 265 VAC line-powered (Model 961 only) INP U T PO W ER 0 m A currentshiftforModel 961 (availablewith InputPow er code 5)

8 A ctuator-Sensor-Interface (AS-i)forMo del960 (availablewith InputPower code 5)

D 5 amp gold flashrelaysforMod el961 (availablew ithInput Power codes 2 or 7) OU TPU T SIGN AL

0 Integral

96 A 0

0 Standard cover

1 Glass window cover

0 Castalum inum with 3⁄4"NP T dualconduitentries

1 Castalum inum with M20 dualconduitentries

4 Deep draw n 304 stainlesssteel

w /1⁄2"N PT dualconduitentries

5 Deep drawn 304 stainlesssteel

HO USING & CO NDUIT CO NNEC TION M odelsavailablefor quick shipment,usuallywithinone week afterfactory receiptofa com pletepurchase order,throughtheExpediteShip Plan(ESP)

1 FM /CSA Intrinsicallysafe,Non-Incendive

& Explosion Proo f*(use w ithcurrent shift Outp ut Signal code 0 )

3 FM /CSA Explosion Proof& No n-Incendive

(use with Outp ut Signalcode 8 & D , and Ho using codes 0,1)

7 FM /CSA N on-incendive(availablewith Output Signal

codes 0,8 & D and Housing codes 4 & 5) A ATE X II1G EEx iaIIC T5,Intrinsicallysafe(available with Ou tputSignalcode 0 and Housing codes 0 &1) C ATE X II1/2G EEx d IICT6, Flameproof (availablewith Output Signalcodes 0,8 & D, and Ho using codes 0 & 1)) AGE NCY A PPRO VA L *Explosion Proofapprovals notavailablewithhousing codes 4 & 5

9 6 0 / 9 6 1 S I N G L E P O I N T T R A N S D U C E R 91 A 11 3⁄4"NP T 3T 11⁄2"Tri-Clam p ® 16 AM P fitting 4T 2"Tri-Clam p ® 16 A M P fitting VV DN 65 – Varivent ® Type N flange PROC ESS CO NNE CTIONS 1"to 130"in1"increm ents 1"m inimum for NP T process connections 2"m inimum for 3T, 4T & VV process connections Examp le:4 inches = 004 AvailableEnglish ESP lengths:1",2",4",6",8",12" 3 cm to 330 cm in 1 cm incremen ts 3 cm minimu m for NPT process connections 5 cm minim um for3T,4T & VV processconnections Examp le:6 centimeters = 006 Availablem etric ESP lengths:3, 5,10,30 cm AC TUATI O N LENGT H ( unitoflength specified insecond digit) M odelsavailableforquick shipment,usuallywithinone week afterfactory receiptofa com pletepurchase order,throughtheExpediteShip Plan(ESP) A English (length ininches) M Metric(length in centimeters) TRAN SDUCER UN IT OF LENGT H A 316/316L stainlesssteel S 316/316L w ith 20 Ra hygienicfinish (use only with ProcessConnectioncodes 3T, 4T,or VV) M A TER IA LS O F CONSTR UC TION

BULLETIN: 51-160.2 EFFECTIVE: August 2011 SUPERSEDES: October 2009 The quality assurance system in place at Magnetrol® guarantees the highest level of quality throughout the company. MAGNETROL is committed to providing full customer satisfaction both in quality products and quality service. The MAGNETROL quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product and service quality available. All MAGNETROL electronic level and flow controls are warranted free of defects in mate- rials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, MAGNETROL will repair or replace the control at no cost to the purchaser (or owner) other than transportation. MAGNETROL shall not be liable for misap- plication, labor claims, direct or consequen- tial damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some MAGNETROL products. 5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com

145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306

Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317 Copyright © 2011 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Performance specifications are effective with date of issue and are subject to change without notice. For additional information, see Instruction Manuals 51-632 & 51-646. Q U A L I T Y W A R R A N T Y Magnetrol, Magnetrol logotype and Echotel are registered trademarks of Magnetrol International, Incorporated. AS-Interface® is a registered trademark of the AS-International Association Kynar® is a registered trademark of Elf Atochem North America, Inc. Hastelloy® is a registered trademark of HAYNES INTERNATIONAL, INC. (DELAWARE CORPORATION) Monel® is a registered trademark of the INCO family of companies Tri-Clamp® is a registered trademark of Ladish Co. Varivent® is a registered trademark of Tuchenhagen GmbH LTD Several ECHOTEL Model 961 units are available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, simply match the color coded model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representa- tive for lead times on larger volume orders, as well as other products and options. EExpedite SShip PPlan E S P