Features
I n d u c t i v e a n a l o g Voltage output Technical Data General specifications Installation non-flush Measurement range 2 ... 5 mm Output type 3-wire Nominal ratings Operating voltage U B 13.5 ... 30 V Output signal 1 ... 9 V Reverse polarity protection yes Short-circuit protection no Load resistor 0 ... 2 kOhm Switching state indicator no Functional safety related parameters MTTFd 1733 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 % Output Output resistance ≤ 50 Ω Ambient conditions Mechanical specifications Connection type Connector plug M12 x 1 , 4-pin Housing material brass, nickel-plated Sensing face Ceramic Degree of protection IP67 Compliance with standards and directives Standard conformity Standards EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates CCC approval CCC approval / marking not required for products rated ≤36 V Dimensions Electrical Connection M12 x 1 60.5 ø 16 M18 x 1