88827103 CROUZET | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
17.5 mm - 1 Relay 8A MUR3 Part number 88827103 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external load connection in parallel to the control input 3-wire PNP sensor compatible Part numbers Specifications TypeFunctions Timing Output Nominal ratingConnectionsSupply voltage 88 827 103MUR3A - Ac - At - B - Bw - C - D - Di - H - Ht 0,1 s→100h1 changeover relay8 A Screw terminals12→240 V AC / DC Timing Timing ranges (7 ranges) 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h Repetition accuracy with constant parameters± 0.5 % (IEC/EN 61812-1) Drift Temperature ± 0,05 % / °C Drift Voltage ± 0,2 % / V Display accuracy according to IEC/EN 61812-1 ± 10 % / 25 °C Immunity from micro power cuts : typical< 10 ms Supply Multi-voltage power supply Depending on version Frequency (Hz) 50 / 60 Operating factor 100 % Output specification Rated power 2000 VA/80 W Maximum breaking current 8 AAC 250 VAC resistive8 ADC 30 VDC resistive Minimum breaking current 10 mA / 5 VDC Voltage breaking capacity 250 VAC / 8 AAC resistive250 VDC / 0,3 A resistive Electrical life (operations) 105
8 A 250 VAC resistive
Mechanical life (operations) 10 x 106 Breakdown voltage acc. to IEC/EN 61812-1 2,5 kV / 1 min / 1 mA / 50 Hz Impulse voltage acc. to IEC/EN 60664-1, IEC/EN 61812-1 5 kVwave 1.2 / 50 μs General characteristics Conformity to standards IEC/EN 61812-1 IEC/EN 61000-6-1 IEC/EN 61000-6-2 IEC/EN 61000-6-3 IEC/EN 61000-6-4 Certifications CE, UL, cUL, CSA, GL Temperature limits use (°C) -20 →+60 Temperature limits stored (°C) -30 →+60 Installation category(acc. to IEC/EN 60664-1) Voltage surge category III Creepage distance and clearance acc. to IEC/EN 60664-1 4 kV / 3 mm Protection (IEC/EN 60529) IP20 IP40 Degree of protection acc. to IEC/EN 60529 Front faceIP50 Vibration resistanceacc. to IEC/EN 60068-2-6 20 m/s2 10 Hz →150 Hz Relative humidity no condensation acc. to IEC/EN 60068-2-30 93 % non-condensing Electromagnetic compatibility - Immunity to electrostatic discharges acc to IEC/EN 61000-4-2 Level III (Air 8 kV / Contact 6 kV) Immunity to radiated, radio-frequency, electromagnetic field acc. IEC/EN 61000-4-3 Level I (1 V/m : 2,0 G Hz →2,7 G Hz) Level II (3 V/m : 1,4 G Hz →2,0 G Hz) Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 08/07/2015 www.crouzet.com
Level III (10 V/m : 80 M Hz →1 G Hz) Immunity to rapid transient bursts acc. to IEC/EN 61000-4-4 Level III (direct 2 kV / Capacitive coupling clamp 1 kV) Immunity to shock waves on power supply acc. to IEC/EN 61000-4-5 Level III (2 kV / common mode 2 kV/residual current mode 1 kV) Immunity to radio frequency in common mode acc. to IEC/EN 61000-4-6 Level III (10V rms : 0.15 M Hz to 80 M Hz) Immunity to voltage dips and breaks acc. to IEC/EN 61000-4-11 0 % residual voltage, 1 cycle70 % residual voltage, 25/30 cycles Mains-borne and radiated emissions acc. to EN 55022 (CISPR22), EN55011 (CISPR11) Class B Fixing : Symmetrical DIN rail35 mm Terminal capacity Single-wire without ferrule1 x 0,5 →3,3 mm2 (AWG 20 →AWG 12) 2 x 0,5 →2,5 mm2 (AWG 20 →AWG 14) Terminal capacity Multi-wire with ferrule1 x 0,5 →2,5 mm2 (AWG 20 →AWG 14) 2 x 0,5 →1,5 mm2 (AWG 20 →AWG 16) Housing material Self-extinguishing Shock test IEC/EN 60068-2-27 15 g - 11 ms Short interruption on power line acc to IEC/EN 61000-4-110 % residual voltage, 250/300 cycles Timing Minimum pulse duration typically (relay version) 30 ms Minimum pulse duration typically (solid state version) 50 ms Minimum pulse duration typically (relay version under load) 100 ms Maximum reset time by de-energisation typically (relay version) 120 ms Maximum reset time by de-energisation typically (solid state version) 350 ms Supply Operating range 85 →110 % Un85 →120 % Un for 12 V AC / DC Max. absorbed power 32 VA (240 VAC) 1,5 W (240 VDC) 0,6 W (24 VDC) 0,7 VA (12 VAC) 0,7 W (12 VDC) Output specification 1 or 2 changeover relays, AgNi (cadmium-free) 1 C/O General characteristics Spring terminals, 2 terminals per connection point - flexible wire 2 x 0,5 →1,5 mm2 (AWG 20 →AWG 16) Spring terminals, 2 terminals per connection point - rigid wire 2 x 0,5 →1,5 mm2 (AWG 20 →AWG 16) Weight : casing 17,5 mm 88827105 (MUR1) : 63 g88827115 (MAR1) : 63 g88827125 (MBR1) : 63 g88827135 (MCR1) : 62 g88827145 (MHR1) : 63 g88827150 (MLR4) : 63 g88827155 (MLR1) : 64 g88827100 (MUR4) : 62 g88827103 (MUR3) : 66 g88827503 (MURc3) : 59 g88827150 (MLR4) : 63 g88827185 (MXR1) : 63 g88827004 (MUS2) : 55 g88827014 (MAS5) : 53 g88827044 (MHS2) : 53 g88827054 (MLS2) : 56 g Insulation resistance according to IEC/EN 60664-1 100 MΩ (500 V DC) Dimensions (mm) Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 08/07/2015 www.crouzet.com
Delay on energisation 1 relay Curves Function Ac Function Ac Timing after closing and opening of control contact 1 relay Curves Function At Function At Timing on energisation with memory 1 relay Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 08/07/2015 www.crouzet.com
Timing on impulse one shot 1 relay Curves Function Bw Function Bw Pulse output (adjustable) 1 relay Curves Function C Function C Timing after impulse 1 relay Curves Function D Function D Flip-flop Pause start 1 relay Curves Function Di Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 08/07/2015 www.crouzet.com
Flip-flop Pulse start 1 relay Curves Function H Function H Timing on energisation 1 relay Curves Function Ht Function Ht Delay on energisation with memory 1 relay Connections 1 changeover relay output Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 08/07/2015 www.crouzet.com