www.marathonsp.com

885 RZ XX

Replace “xx” with 01 to 12 for number of poles Terminal Block

85 Amps 600 Volts AC/DC

  • Line: #4 - #18 AWG Cu
  • Load: #4 - #18 AWG Cu Electrical Ratings
  • 85 Amps
  • 600V per UL 1059 & CSA 22.2 No.158, class B & C requirements
  • SCCR of 10,000 A (default for terminal blocks).
  • CU7 - 75°C connector terminal rating with copper wire
  • Factory & Field Wiring Agency Compliance
  • UR - UL Recognized Terminal Block, Evaluated to UL 1059, File No.XCFR2.E62806
  • cUR - UL Evaluated to C22.2 No. 158, File No. XCFR8.E62806
  • CE compliant to IEC 60947-7-1
  • RoHS Compliant Material Information
  • Insulator base:
  • Thermoplastic
  • Flammability rating of insulator base UL94V0
  • Insulator base temperature rating: -40°C to 130°C (UL RTI)
  • Collar: aluminum, tin (over copper) plated
  • Screws: steel, tin plated
  • RoHS compliant

www.marathonsp.com REV-C 07/13/2020 Termination Specifications Installation & Accessories

  • Mounting (Panel):
  • For use with #8 fastener.
  • Mounting torque to be determined in end use application not to exceed 20 lbf·in Wire Size T orque Copper Wire Stranding Classes - Number of Conductors Solid Class B Class C 4 16 in. lbs N/A 1 1 6 16 in. lbs N/A 1 1 8 16 in. lbs N/A 1 or 2* 1 or 2* 10 16 in. lbs 1 to 4 * 1 to 4* 1 to 4* 12 16 in. lbs 1 to 4 * 1 to 4* 1 to 4* 14 16 in. lbs 1 to 6 * 1 to 6* 1 to 6* 16 16 in. lbs 1 to 6 * 1 to 6* 1 to 6* 18 16 in. lbs 1 to 8* 1 to 8* 1 to 8* *If using two or more conductors, they must be the same size
  • Wire strip length – 9/16”

www.marathonsp.com REV-C 07/13/2020 Drawing Lines DIM “A”±.02 [.38] DIM “B”±.02 [.38]