Visit product website DATA SHEET Type 8805 Ball valve / Butterfly valve with pneumatic rotary actuator Type 2051 Pneumatic rotary actuator Type 8798 Remote sensor for pneumatically actuated process valves Type 2301 Pneumatically operated 2-way Globe Control Valve Type 2300 Pneumatically operated 2-way angle seat control valve ELEMENT Type 2103 2/2-way diaphragm valve with pneumatic stainless steel actuator (Type ELE- MENT) for decentralised automation Standard | EU | en | 2024 - 03 - 07 | 28 Digital electropneumatic positioner SideControl
- Compact and robust design Easy to start up using Tune function Integrated diagnostic functions for valve monitoring Dynamic actuating system with no air consumption in controlled state EtherNet/IP, PROFINET, Modbus TCP, PROFIBUS DP-V1 or Bürkert system bus (büS) The robust and compact positioner is designed with standardisation acc. to IEC 60534 1 or VDI/VDE 3845 (IEC 60534 2) for assembly onto linear and rotary actuators. In addition, the variant with remote position sensor can be combined with Bürkert process control valves for closed-loop control. The digital electro pneumatic positioner, SideControl, can be operated with all standard current and voltage standard signals and can also optionally be equipped with the fieldbus interface. The positioner is equipped with additional diagnostic functions to monitor the valve. Valve diagnostic messages via status signals are issued in accordance with NE107 (NAMUR) and recorded as historical entries. The diagnos- tics can be used to monitor the operating conditions of the control valve which makes maintenance decisions predictable and optimises the availability of the plants as required. Operation occurs via the external operating and display module consisting of a graphic display with backlight. For the user, this results in very simple and clear operation, which is identical to the Bürkert ELEMENT 8692/8693 positioners and process controllers. The pneumatic actuating system can be used equally for single-acting and double-acting actuators. It features a defined safety response in the event of failure of the electrical or pneumatic power supply and has an enormous air capacity range with pressure supply up to 7 bar. Product variants described in the data sheet may differ from the product presentation and description. Type description Can be combined with Type 8792 © Christian Bürkert GmbH & Co. KG, Subject to alteration
2 | 30Visit product website Table of contents 1. General technical data 4 1.2. Linear remote position sensor (ELEMENT Type 8798) .... 1.3. Rotative remote position sensor (NAMUR) .... 1.4. Position feedback with proximity switches (accessories for retrofitting) ... 2. Approvals and conformities 8 2.2. Conformity ... 2.3. Standards .... 2.4. Explosion protection ... Positioner SideControl Type 8792 2.5. North America (USA/Canada) ... Positioner SideControl Type 8792 Linear position sensor, remote (ELEMENT Type 8798) Rotative position sensor, remote (NAMUR Type 8798) 2.6. Others China Compulsory Certification (CCC) 3. Dimensions 10 3.2. Remote version 3.3. Mounting specification of NAMUR/Remote Version .... NAMUR version Remote version 3.4. ATEX/IECEx version 3.5. Remote position sensor version ... 3.6. Mounting on control valve according to NAMUR ... 4. Device/Process connections 15 EtherNet/IP, PROFINET, Modbus TCP connection Bürkert system bus (büS) connection 5. Performance specifications 21 Position control loop Additional software options of positioner SideControl Type 8792 (extract) 5.2. Interface diagram .... Version without fieldbus communication Version with fieldbus communication 6. Product installation 23 NAMUR version Remote version Position feedback with proximity switches 6.2. Combination possibilities with pneumatic process valves ...
3 | 30Visit product website 7. Ordering information 27 7.2. Bürkert product filter 7.3. Ordering chart Positioner SideControl Type
8792 NAMUR version
Positioner SideControl Type 8792 remote version Remote position sensor for remote version of SideControl Type 8792 7.4. Ordering chart accessories .... Standard accessories Accessories SideControl Remote
4 | 30Visit product website 1. General technical data 1.1. Positioner SideControl Type 8792 Product properties Dimensions Further information can be found in chapter “3. Dimensions” on page 10 Material Housing Aluminium, plastic-coated Seal EPDM, NBR, FKM Operation Display Graphic display with backlight and intuitive menu navigation Operating keys Membrane keypad with 4 keys Service interface Connected to PC via USB connection Configuration tool Bürkert Communicator PACTware (only for device versions with PROFIBUS) Commissioning Initialisation positioner Automatic by X.TUNE function (automatic adjustment of the positioner) Status display Optical position indicator (mechanical) Integrated (for NAMUR Version) Communication Fieldbus EtherNet/IP, PROFINET, Modbus TCP, PROFIBUS DP-V1 Digital Bürkert system bus (büS) (based on CANopen) Performance data Position sensor Integrated position sensor (NAMUR) Conductive plastic rotary potentiometer External remote position sensor Linear or rotative Measuring range for rotary actuator PROFIBUS Rotation angle: 30°…150° EtherNet/IP, PROFINET, Modbus TCP and büS Rotation angle: 30°…180° Stroke range for linear actuator 3…130 mm, depending on the lever of the attachment kit Electrical data Operating voltage 24 V DC ± Residual ripple Max. 10 Power consumption < W Protection class III according to DIN EN 61140 Input /Output Digital input 1 digital input, galvanically isolated, 0…5 V = log “0”, 10…30 V = log “1” Digital output 2 digital output (optional), galvanically isolated Current limitation pro digital output 100 mA, output will be synchronised when overloaded Analogue output 1 output (optional) 0/4…20 mA, 0…5/10 V Input data setpoint and actual value Setpoint signal Setpoint setting 0/4…20 mA 0…5/10 V Input resistance 0/4…20 mA: 70 Ω 0…5/10 V: 20 kΩ Electrical connection Multipole version Screw terminals: M8, M12 according to device version (see connection description) Cable gland version 2x M20 1.5 (cable Ø 6…12 mm) on screw terminals (0.14…1.5 mm²) Remote version 1x M12 1.5 (cable Ø 3…6.5 mm)
5 | 30Visit product website Pneumatic data Control medium Neutral gases, air, quality class according to ISO 8573 Dust content Class 7 (< µm particle size) Particle density Class 5 (< mg/m3) Pressure dew point Class 3 (<- °C) Oil content Class X (< mg/ m3) Air supply filter Exchangeable Mesh size ~0.1 mm Supply pressure 1.4…7 bar 1.) 2.) Pilot air port Threaded port G ¼ Positioning system Universal air capacity Single and double acting 50 lN/min (at 1.4 bar 2.)) for aeration and ventilation 150 lN/min (at 6 bar 2.)) for aeration and ventilation QNn= 100 lN/min Low air capacity Single acting QNn= 7 lN/min (QNn according to definition at pressure drop from 7 to 6 bar abs) Approvals and conformities Explosion protection Ignition protection class II 3D Ex tc IIIC T135 °C Dc II 3G Ex ec IIC T4 Gc ATEX BVS 16 ATEX E 118 X II 3G Ex ec ic IIC T4 Gc II 3D Ex tc IIIC T135 °C Dc IECEx IECEx BVS 16.0091 X Ex ec ic IIC T4 Gc Ex tc IIIC T135 °C Dc Further information can be found in chapter “2.4. Explosion protection” on page 8 North America (USA/Canada) CSA for Canada and the USA UL 429 (Electrically operated valves) CSA C22.2 No. 139 (Electrically operated valves) Further information can be found in chapter “2.5. North America (USA/Canada)” on page 8 Others China Compulsory Certification (CCC) The products with Ex approval are suitable for import and use for hazardous applications in China. Further information can be found in chapter “2.6. Others” on page 9 Further information can be found in chapter “2. Approvals and conformities” on page 8 Environment and installation Operating conditions Ambient temperature With ATEX-/IECEx approval 0…+ Without Ex approval - 10…+ Degree of protection IP65/IP67 according to EN 60529, 4X according to NEMA 250 Standard Operating altitude Up to 2000 m above sea level Installation and mechanical data Mounting variant NAMUR according to IEC 60534 1 resp. VDI/VDE 3845 (IEC 60534 2), remote Installation position As required, display above or laterally Valve actuator (type, size) Rotary and linear actuators according to NAMUR, ELEMENT Type 2301, 2300 (actuator size Ø 70/90/130/225 mm) and CLASSIC (actuator size Ø175/225 mm) in combination with remote version Adapter kit Further information can be found in chapter “7.4. Ordering chart accessories” on page 30 1.) Supply pressure has to be 0.5…1 bar above the minimum required pilot pressure for the valve actuator . 2.) Pressure data: overpressure to atmospheric pressure
6 | 30Visit product website 1.2. Linear remote position sensor (ELEMENT Type 8798) Note: When mounting the remote positioner away from the actuator, the length of the pneumatic control lines influences the dynamics and accuracy of the position control loop. The length of the control air lines should therefore be as short as possible. Product properties Actual position signal Digital (RS485) Detection range of the sensor 3…45 mm (stroke range of valve spindle) Electrical data Operating voltage 24 V DC ± Protection class III according to DIN EN 61140 Power consumption < 0.3 W Electrical connection Cable gland (cable length) 1x M16 1.5 (cable Ø 5…10 mm) on screw terminals (0.14…1.5 mm²) Connection cable 10 m Approvals and conformities Protection class IP65 and IP67 according to EN 60529, 4X according to NEMA 250 standard Explosion protection Ignition protection class II 3G Ex ec IIC T4 Gc II 3D Ex tc IIIC T135 °C Dc Further information can be found in chapter “2. Approvals and conformities” on page 8 North America (USA/Canada) UL Recognized for the USA and Canada cULus certificate: 238179 Further information can be found in chapter “2.5. North America (USA/Canada)” on page 8 Others China Compulsory Certification (CCC) The products with Ex approval are suitable for import and use for hazardous applications in China. Further information can be found in chapter “2.6. Others” on page 9 Further information can be found in chapter “2. Approvals and conformities” on page 8 Environment and installation Ambient temperature - 25…+ 1.3. Rotative remote position sensor (NAMUR) Note: When mounting the remote positioner away from the actuator, the length of the pneumatic control lines influences the dynamics and accuracy of the position control loop. The length of the control air lines should therefore be as short as possible. Product properties Stroke range when mounted to linear actuator 3…130 mm, depending on the lever of the attachment kit Actual position signal Digital (RS485) Measuring range Rotation angle 30°…180° Electrical data Operating voltage 10…30 V DC Protection class III according to DIN EN 61140 Power consumption < 0.8 W Electrical connection 2 m round cable (shielded) Approvals and conformities Protection class IP65 according to EN 60529 North America (USA/Canada) UL Recognized for the USA and Canada cULus certificate: E226909 Further information can be found in chapter “2.5. North America (USA/Canada)” on page 8 Further information can be found in chapter “2. Approvals and conformities” on page 8 Environment and installation Ambient temperature - 25…+
7 | 30Visit product website 1.4. Position feedback with proximity switches (accessories for retrofitting) Note: The feedback unit possesses 2 proximity switches that can be adjusted independently of each other via switch flags. Product properties Output function 3-wire, normally open contact, PNP Electrical data Electrical connection M12, 4-pin Operating voltage 10…30 V DC Protection class III according to DIN EN 61140 DC-rated current ≤ 100 mA Residual ripple ≤ % Uss Approvals and conformities Degree of protection IP65 and IP67 Further information can be found in chapter “2. Approvals and conformities” on page 8
8 | 30Visit product website 2. Approvals and conformities 2.1. General notes
- The approvals and conformities listed below must be stated when making enquiries. This is the only way to ensure that the pro duct complies with all required specifications. Not all available versions can be supplied with the below menti oned approvals or conformities. 2.2. Conformity In accordance with the Declaration of Conformity, the product is compliant with the EU Directives. 2.3. Standards The applied standards which are used to demonstrate compliance with the EU Directives are listed in the EU-Type Examination Certificate and/or the EU Declaration of Conformity. 2.4. Explosion protection Positioner SideControl Type 8792 Approval Description Optional: Explosion protection ATEX: BVS 16 ATEX E 118 X II 3G Ex ec ic IIC T4 Gc II 3D Ex tc IIIC T135 °C Dc IECEx: IECEx BVS 16.0091 X Ex ec ic IIC T4 Gc Ex tc IIIC T135 °C Dc 2.5. North America (USA/Canada) Positioner SideControl Type 8792 Approval Description Optional: CSA for Canada and the USA The products are CSA approved for Canada and the USA according to: UL 429 (Electrically operated valves) CSA C22.2 No. 139 (Electrically operated valves) Linear position sensor, remote (ELEMENT Type 8798) Approval Description Optional: UL Listed for the USA and Canada The products are UL Listed for the USA and Canada according to: UL 61010 1 (ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE – Part 1: General Requirements) CAN/CSA-C22.2 No. 61010 Rotative position sensor, remote (NAMUR Type 8798) Approval Description Optional: UL Listed for the USA and Canada The products are UL Listed for the USA and Canada according to: Certificate no.: E226909
9 | 30Visit product website 2.6. Others China Compulsory Certification (CCC) Positioner SideControl Type 8792 and Linear Position Transducer Remote (ELEMENT Type 8798) Conformity Description Optional: China Compulsory Certification (CCC) The products with Ex approval are suitable for import and use for hazardous applications in China.
10 | 30Visit product website 3. Dimensions 3.1. NAMUR version Note: Dimensions in mm Cable gland (standard) 7.5 109.8 7.5 81.8 A PROFIBUS DP Multipole A Multipole with digital outputs A Cable gland A Multipole 49.9 97.4 144.6 L 81.9 98.9 R A1 P A2 Description L A A1 A2 Standard 171.1 31 30 – PROFIBUS DP 157.8 36 31 13.5 Multipole digital outputs 157.6 36 31 – Multipole 157.4 – 22.5 – Remote 171.1 31 30 11.5
11 | 30Visit product website 3.2. Remote version Note: Dimensions in mm A Cable gland 49.9 144.6 L 81.9 R A1 P A2 A Multipole/Bus 452x M4 Description L A A1 A2 A3 A4 A5 Remote cable gland 171.1 31 30 11.5 – – – Remote multipole/bus 157.8 36 31 13.5 36 20 11
12 | 30Visit product website 3.3. Mounting specification of NAMUR/Remote Version Note: Dimensions in mm The rotary motion of the sensor shaft must be within a range of max. 180°. 1.)
- The sensor shaft must be in this position at approx. 50 % valve opening. NAMUR version 180° 1) Ø50 7.5 45° 4x90° 4 x M6 4 x M8 1.) Max. 180° are possible for the EtherNet/IP, PROFINET, Modbus TCP and büS variants, max. 150° for the other variants. Remote version 2x M4
13 | 30Visit product website 3.4. ATEX/IECEx version Note: Dimensions in mm 94.6 111.85 3.5. Remote position sensor version Note: Dimensions in mm Linear position sensor Type 8798 for valve position detection of Bürkert ELEMENT valves and hygienic process valves for the remote SideControl positioner. 99.5 Ø 91 114 17.1 119
14 | 30Visit product website 3.6. Mounting on control valve according to NAMUR Note: Dimensions in mm Rotative position sensor to detect rotary motion of rotary actuators according to NAMUR/IEC 60534 1 and VDI/VDE 3845 (IEC 60534 2) for the remote SideControl positioner. 36.1 46 20 SW 17 40 23.5 5
15 | 30Visit product website 4. Device/Process connections 4.1. Electrical connections Multipole connection Earthing function M12 Circular connector, 8-pin Operating voltages with diverse signals Digital outputs (optional) M8 socket, 4-pin 1 3 M12 circular plug, 8-pin (setpoint) Pin Pin assignment Outer circuitry/Signal level
1 Setpoint + (0/4…20
mA or 0…5/10 Completely galvanically isolated
2 Setpoint GND 2 GND
3 GND 3 24 V DC ± 10 %
Max. residual ripple 10 %4 + V 4
5 Digital input + 5 +
0…5 V (log “0”) 10…30 V (log “1”)
6 Digital input GND 6 GND
8 Analogue feedback + 8 + (0/4…20 mA or 0…5/10 V)
Completely galvanically isolated
7 Analogue feedback GND 7 GND
M8 socket, 4-pin (only for digital outputs options) Pin Pin assignment Outer circuitry/Signal level
1 Digital output 1 1 24 V/0 V, NC/NO
Relative to operating voltage GND (terminal GND)
2 Digital output 2 2 24 V/0 V, NC/NO
Relative to operating voltage GND (terminal GND)
3 Digital output GND 3 GND
16 | 30Visit product website Position feedback with proximity switches Note: Accessories for upgrading Proximity switch 1 Proximity switch 2 No. Pin assignment Outer circuitry/Signal level
1 Supply 10…30
10…30 V 10…30 V
2 Switching output (NO)
10…30 V Open/10…30 V
3 GND GND GND
4 Switching output (NO)
10…30 V Open/10…30 V Screw terminal connection +24 V GND 83 + 85 + 31 + 32 – 11 + 12 – 81 + S + S – A B Terminal assignment A Terminal Pin assignment External circuitry/signal level 11 + Setpoint + 11 + + (0/4…20 mA or 0…5/10 V) Completely galvanically isolated 12 – Setpoint GND 12 – GND 81 + Digital input + 81 + + 0…5 V (log. “0”) 10…30 V (log. “1”) Relative to operating voltage GND (terminal GND) V GND Operating voltage + Operating voltage GND V GND
24 V DC ± 10 %
Maximum residual ripple 10
17 | 30Visit product website Analogue feedback option/digital output Terminal Pin assignment Outer circuitry/Signal level 83 + Digital output 1 83 + 24 V/0 V, NC/NO Relative to operating voltage GND (terminal GND) 85 + Digital output 2 85 + 24 V/0 V, NC/NO Relative to operating voltage GND (terminal GND) 31 + Analogue feedback + 31 + + (0/4…20 mA or 0…5/10 V) Completely galvanically isolated 32 – Analogue feedback GND 32 – GND Remote version option in conjunction with remote position sensor Type 8798 Note: For variants without remote version: Terminals A, B, S + and S - not connected Terminal Pin assignment Outer circuitry/Signal level Remote position sensor A Serial interface, A-line A A-line Remote sensor Type 8798 B Serial interface, B-line B B-line S + Sensor supply + S + + S – Sensor supply – S – – Remote position sensor Type 8798 Terminal Wire colour for cable type Pin assignment Outer circuitry 1 2
1 White Black Sensor supply – 1 8791 or
2 Brown Sensor supply + 2 8792/8793
3 Yellow Orange Serial interface, B-line 3 8791 or
4 Green Red Serial interface, A-line 4 8792/8793
M12 circular plug, 8-pin M12 circular plug, 5-pin (inverse coded, PROFIBUS DP) M12 socket, 5-pin (inverse coded, PROFIBUS DP) Earthing function FE
18 | 30Visit product website Operating voltage, M12 circular plug, 8-pin Pin Pin assignment Outer circuitry/Signal level
1 Not assigned
2 Not assigned
V Maximum residual ripple 10
5 Digital input +
6 Digital input –
7 Digital output 1 (relative to pin 3)
8 Digital output 2 (relative to pin 3)
Fieldbus connection, M12 socket/circular plug, 5-pin Pin Pin assignment Outer circuitry/Signal level
1 VP+
5 Load resistance supply
2 RxD/TxD-N Receive/transmit data -N, A-line
3 DGND Information transfer potential (measured to 5
4 RxD/TxD-P Receive/transmit data -P, B-line
5 Shield Shielding/protective earth
EtherNet/IP, PROFINET, Modbus TCP connection M12 Fieldbus connections (2 Port Ethernet Switch) M12 circular plug 8-pin
8 M8 socket, 4-pin,
optional (only with remote version) M12 fieldbus connection, D-coded Connection for EtherNet/IP takes place via an M12 screw terminals, 4-pin, D-coded Pin Description
1 Transmit +
2 Receive +
3 Transmit –
4 Receive –
19 | 30Visit product website Operating voltage, M12 circular plug, 8-pin Pin Pin assignment Device side Outer circuitry/Signal level Maximum residual ripple 10 %4 + V 4 Input signal of the control centre (e. g. SPS) 0…5 V (log. “0”) 10…30 V (log. “1”)
6 Digital input – 6 GND (identical to pin 3)
Output signal of the control centre (e. g. SPS) - (only used with digital output option)
7 Digital output 1 (relative to pin 3) 7 0…24 V
8 Digital output 2 (relative to pin 3) 8 0…24 V
Connection of digital remote position sensor Type 8798, M8 socket, 4-pin (optional) Pin Pin assignment Device side Outer circuitry
1 Sensor supply + S + +
2 Sensor supply – S – –
3 Serial interface, A-line A A-line
4 Serial interface, B-line B B-line
Bürkert system bus (büS) connection M12 circular plug, 5-pin M8 socket, 4-pin, optional (only with remote version) Earthing function FE 1 3 M12 circular plug 8-pin 1 2 Fieldbus connection screw terminals M12 x 1, 5-pin Pin Cable colour Description
1 CAN Shielding CAN Shielding
3 Black GND/CAN_GND
4 White CAN_H
5 Blue CAN_L
20 | 30Visit product website Operating voltage, circular plug M12, 8-pin Pin Pin assignment Device side Outer circuitry/Signal level
3 GND 3
Maximum residual ripple 10 %4 + V Input signal of the control centre (e. g. SPS) 0…5 V (log “0”) 10…30 V (log “1”) Output signal of the control centre (e. g. SPS) (only used with digital output option) Connection of digital remote position sensor Type 8798, M8 socket, 4-pin (optional) Pin Pin assignment Device side Outer circuitry Connection of analogue remote position sensor, M8 socket, 4-pin (optional) Pin Pin assignment Device side Outer circuitry
1 Potentiometer 1 1
2 Wiper 2
3 Potentiometer 3
4 Not assigned
21 | 30Visit product website 5. Performance specifications 5.1. Signal flow diagram Position control loop Set-point position value CMD POS Position controller Control system Position measuring systemPosition control loop Valve opening Proportional valve Xd1 B1 PK Additional software options of positioner SideControl Type 8792 (extract) Automatic commissioning of control system Automatic or manual characteristics curves selection Setting of seal and maximum stroke threshold respectively Parameterisation of positioner Limitation of stroke range Limitation of manipulating speed Setting of moving direction Configuration of digital input Signal range splitting on several controllers Configuration of analogue or 2 digital outputs Signal fault detection Safety position Code protection Contrast inversion of display Parameterizable diagnostic functions 1.)/digital output (option) Operating-hours counter Path accumulator Position monitoring Graphical display of dwell time density and movement range Monitoring of mechanical end positions in armature 1.) Further diagnostic functions with detailed description can be found in the operating Instructions Type 8792 .
22 | 30Visit product website 5.2. Interface diagram Version without fieldbus communication Input for Setpoint position value 4… 20mA, 0… 20 mA 0-10 V, 0-5 V Digital input Operation Positioner Input Output Supply 2 digital outputs 24 V PNP 2.) Analogue feedback 2.) 4… 20mA, 0… 20mA, 0-10 V, 0-5 V Initiator 1/Initiator 2 24 V PNP NO 2.) 24 V DC 1.) Version with fieldbus communication PROFIBUS DP, EtherNet/IP, PROFINET, Modbus TCP and Bürkert system bus (büS) Bus Operation Positioner PROFIBUS DP EtherNet/IP PROFINET Modbus TCP büS Input Output Supply unit Bus 2 digital outputs 24 V PNP 2.) Digital input 24 V DC 1.) Initiator 1 / Initiator 2 24 V PNP NO 2.) 1.) Operating voltage is supplied with a 3-wire unit independent from the setpoint signal. 2.) Alternative options
23 | 30Visit product website 6. Product installation 6.1. Mounting options NAMUR version Note: Positioner with integrated position sensor, installation according to NAMUR/IEC 60534 1 and VDI/VDE 3845 (IEC 60534 The NAMUR version of the SideControl positioner is equipped with an integrated position sensor (linear or rotary). It has a standardised interface for direct attachment to linear actuators according to NAMUR/IEC 60534 1 and VDI/VDE 3845 (IEC 605334 2). Linear actuators Rotary actuators See operating manual Type 8792 See operating manual Type 8792 Description Article no. Mounting kit 787215 Description Article no. Adapter kit 787338 Mounting bracket 770294 Adapter kit for rotary actuators (Article no. 787338) Mounting bracket for rotary actuator (Article no. 770294) 4.9 -0.1 8 +0.1 A 107.6 B R34 19.5 R7 C Actuator shaft height A B C [mm] [mm] [mm] [mm] 20 46.5 80 – 30 56.5 80 130 50 76.5 – 130
24 | 30Visit product website Remote version Note: Dimensions in mm 2 mounting options The SideControl positioner remote version is used to control process control valves in combination with a remote position sensor. The remote position sensor is mounted directly on the valve to detect the valve position. The remote positioner can be mounted on the wall or on a standard rail in a control cabinet. Wall mounting with accessory bracket 120 131.5 196.1 Ø4.7 174 36 8.5 10.5 8.5 Description Article no. Bracket for wall mounting 675715 Mounting on Standard rail Note: Dimensions in mm Adapter can be turned by 90º the standard rail. 36.3 10.3 Description Article no. Holder for standard rail mounting 675702
25 | 30Visit product website Position feedback with proximity switches Note: Upgrade feature for SideControl NAMUR External position indicator Cover for standard display element Housing cover Connecting external position indicator Description Article no. Position feedback 677218
26 | 30Visit product website 6.2. Combination possibilities with pneumatic process valves Note: Further information can be found in chapter “7.3. Ordering chart” on page 28 Positioner SideControl 8792
8792 NAMUR 8792 Remote 8792 Remote
(IEC 60534 Linear actuators IEC 60534 Rotary actuators VDI/VDE 3845 (IEC 60534 Control valve system Type 8805 Ball valve/Butterfly valve with pneumatic rotary actuator Type 8798 Remote sensor for pneumatically actuated process valves Type 2300 Pneumatically actuated 2-way angle seat control valve ELEMENT Type 8798 Remote sensor for pneumatically actuated process valves
27 | 30Visit product website 7. Ordering information 7.1. Bürkert eShop Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 7.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter
28 | 30Visit product website 7.3. Ordering chart Positioner SideControl Type 8792 NAMUR version Note: Mounting according to NAMUR IEC 60534 1 resp. VDI/VDE 3845 (IEC 60534 Further versions are available on request. Communication Electrical connection Analogue feedback
2 Digital
Diagnostics 1.) cCSAus ATEX II 3 GD/IECEx CCC 2.) Article no. Single and double-acting with universal air capacity Without fieldbus communication Cable gland – – – Yes – 317985 – Yes Yes Yes – 317987 Yes Yes Yes Yes – 317986 Yes Yes Yes – Yes 318036 Multipole – – – Yes – 317988 – Yes Yes Yes – 317990 Yes Yes Yes Yes – 317989 PROFIBUS DP-V1 Multipole Via bus – – Yes – 206616 Via bus – – – Yes 310308 Via bus Yes Yes – Yes 310309 Via bus Yes Yes Yes – 206617 EtherNet/IP Multipole Via bus – Yes Yes – 317932 Via bus Yes Yes Yes – 317933 Via bus – Yes – Yes 317938 Via bus Yes Yes – Yes 317939 PROFINET Multipole Via bus – Yes Yes – 317942 Via bus Yes Yes Yes – 317943 Via bus – Yes – Yes 317948 Via bus Yes Yes – Yes 317949 Modbus TCP Multipole Via bus – Yes Yes – 317952 Via bus Yes Yes Yes – 317953 Via bus – Yes – Yes 317958 Via bus Yes Yes – Yes 317959 Bürkert system bus (büS) Multipole Via bus – Yes Yes – 317962 Via bus Yes Yes Yes – 317963 Via bus – Yes – Yes 317968 Via bus Yes Yes – Yes 317969 1.) See “Additional software options of positioner SideControl Type 8792 (extract)” on page 21 2.) CCC (China Compulsory Certificate) for device versions with Ex approval
29 | 30Visit product website Positioner SideControl Type 8792 remote version Note: Further versions are available on request. Communication Electrical connection Analogue feedback Diagnostics 1.) cCSAus ATEX II 3 GD/IECEx CCC 2.) Article no. Single-acting with low air capacity for actuator series Type 23xx (Ø70/90 mm) Without fieldbus communication Cable gland Yes Yes Yes Yes – 318010 – Yes Yes Yes – 318011 EtherNet/IP Multipole Via bus Yes Yes Yes – 317936 PROFINET Via bus Yes Yes Yes – 317946 Modbus TCP Via bus Yes Yes Yes – 317956 Bürkert system bus (büS) Via bus Yes Yes Yes – 317966 Single and double-acting with universal air capacity for actuator series Type 23xx (Ø130/225 mm) and 27xx (Ø175/225 mm) Without fieldbus communication Cable gland – – – Yes – 317991 Yes Yes Yes Yes – 317992 – Yes Yes Yes – 317993 Yes Yes Yes – Yes 318038 EtherNet/IP Multipole Via bus Yes Yes Yes – 317935 PROFINET Via bus Yes Yes Yes – 317945 Modbus TCP Via bus Yes Yes Yes – 317955 Bürkert system bus (büS) Via bus Yes Yes Yes – 317965 1.) See “Additional software options of positioner SideControl Type 8792 (extract)” on page 21 2.) CCCC (China Compulsory Certificate) for device versions with Ex approval Remote position sensor for remote version of SideControl Type 8792 Product Mounting version Electrical connection cULus ATEX II 3 GD/IECEx CCC 1.) Article no. Mounting on control valves Type 8798 Control valve Type 23xx Cable gland - 10 m round cable Yes – 300730 Cable gland - m round cable – Yes 20003944 Multipole - m round cable Yes – 307956 Control valve Type 27xx Cable gland - m round cable Yes – 211535 Cable gland - m round cable – Yes 226859 Multipole - m round cable Yes – 329888 NAMUR mounting NAMUR (rotative) Cable gland m round cable (extend able to m maximum) Yes – 211536 1.) CCC (China Compulsory Certificate) for device versions with Ex approval
30 | 30Visit product website 7.4. Ordering chart accessories Standard accessories Note: The associated communication software can be downloaded under Type 8792 Description Article no. M12 circular socket with cable, 8-pin, cable length: 5 m, for input and output signals 919267 M8 plug, 4-pin for digital outputs, with solder joints 917131 USB büS interface set 2 (Type 8923) for connection to the Bürkert Communicator software: including büS stick, connection cable to M12 plug, M12 connection cable on micro USB for the büS service interface and Y distributor, cable length: 0.7 m 772551 büS cable extension, M12, cable length: 1 m 772404 büS cable extension, M12, cable length: 3 m 772405 büS cable extension, M12, cable length: 5 m 772406 büS cable extension, M12, cable length: 10 m 772407 Silencer G ¼ 780780 USB interface for serial communication 227093 Software Bürkert Communicator Type 8920 AS-Interface flat cable clamp, M12 outlet, stainless steel outlet 799646 Accessories SideControl NAMUR Note: Further information can be found in chapter “6. Product installation” on page 23 Description Article no. VDI/VDE 3845 stainless steel universal assembly bridge (IEC60534 2) 770294 Attachment kit for stainless steel rotary actuators according to VDI/VDE 3845 (IEC 60534 2) 787338 Attachment kit for linear actuators according to IEC 60534 1 787215 Position feedback with proximity switches (optional upgrade feature) 1.) 677218 1.) External end position feedback for upgrading SideControl NAMUR Accessories SideControl Remote Description Article no. Mounting bracket for stainless steel wall mount (spare part), see “6. Product installation” on page 23 675715 Standard rail assembly kit aluminium/stainless steel, see “6. Product installation” on page 23 675702 Attachment kit for Type 21xx/23xx actuator series, actuator size Ø 70/90/130 mm 679917 Attachment kit for Type 21xx/23xx actuator series, actuator size Ø 225 mm 60025906 Adapter kit remote sensor, control valves Type 27xx, actuator size Ø 175/225 mm 679945 Sensor puck (replacement part) 682240