Visit product website  DATA SHEET Type 6011  Plunger valve 2/2 way direct-acting Type 8611  eCONTROL - Universal controller Type 6606  2/2 or 3/2 way Rock- er-Solenoid Valve with separating diaphragm Type 8619  multiCELL - Multi-chan- nel and multi-function transmitter/controller 1000116945 | Standard | EU | en | 202203 | 08 Liquid Flow Meter (LFM)

  • High dynamic flow measur ement Applicable for liquid flow measur ement up to 600 ml/min (36 l/h) No moving par ts in medium P rotection class IP65 Fieldbus optional Type 8709 is an instrument for liquid flow measurement in process technolo- gy. The actual value supplied by the sensor is transmitted through the digital electronics and over a standard signal output or a fi eld bus interface. In the device two calibration curves can be stored, which the user is able to switch between. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 8709 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 11 Visit product website  Table of contents 1. Gener al technical data 3 Materials 3. Dimensions 5 4. Device/P rocess connections 6 5. P roduct operation 7 6. Or dering information 8 6.2. Recommendation r egarding product selection 6.3. Bürk ert product filter 6.4. Or dering chart accessories 6.5. Adapt er sketch

3 | 11 Visit product website  1. Gener al technical data Product properties Material Body Stainless steel Housing PBT Seal FKM, EPDM or FFKM Dimensions 115 137.5 37 (BxHxT) Detailed information can be found in chapter “3. Dimensions” on page 5. Total weight Approx. 1100 g LED display Indication for: 1. Power 2. Communication 3. Limit 4. Error Performance data Full scale range (Q Measuring range 1:10 Max. operating pressure Up to max. 10 barg; typical max. 2 barg Measuring accuracy ± 1.5 % o. R. ± 0.5 % F . S. Repeatability ± 0.5 % F . S. Response time (t95 %) < 500 ms Electrical data Oper ating voltage 24 V DC Power consumption Max. 2.5 W (5 W with fieldbus version) V oltage tolerance ± Residual ripple < Electrical connection Socket, round, 8 pin Socket, Sub-HD, 15 pin Plug or socket, M12 5 pin (with fieldbus version) Medium data Operating medium Clean and low viscous liquids Calibration medium Water (conversion to operating medium with correction function) Medium temperature - °C…+ V iscosity (max.) 0.4 to 4 cSt Process/Port connection & communication Port connection G ⅛, NPT ⅛, G ¼, NPT ¼ Digital outputs Two relay-output for: 1. Limit (process value close to Q Nom) 2. Error (e. g. Sensor break) Current output: max. 60 V, 1 A, 60 VA Digital inputs Three switching inputs: 1. Not assigned 2. Not assigned 3. Not assigned Digital (communication) interface Digital via Fieldbus:

  • PROFIBUS DP V1
  • CANopen Analogue interfaces 4…20 mA, 0…20 mA, 0…10 V or 0…5 V Input impedance > 20 kΩ (V oltage) resp. < 300 Ω (Curr ent) Max. load: 10 mA (Voltage output); Max. Load: 600 Ω (Current output) Environment and installation Ambient temperature 0 °C…55 Installation position Horizontal or vertical Degree of protection IP65

4 | 11 Visit product website  2. Mat erials 2.1. Chemical Resistance Char t – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? V erify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check

5 | 11 Visit product website  3. Dimensions 3.1. S tandard version Note: Dimensions in mm In devices without fieldbus communication ther e is no electrical M12 connector in the upper housing part. 115 137.5 16.5 A 1010 A M4 - 8 deep M4 - 8 deep 12.5 112 KalibrierungDatum: Druck: Einbaulage: QC passed Size A G ⅛ G ¼ NPT ⅛ NPT ¼

6 | 11 Visit product website  4. Device/P rocess connections 4.1. Analogue version/Fieldbus version Note: Optional P in 7 and 8 with bus version as transmitter input possible. The cable length for RS232/actual value signal is limit ed to 30 meters. Analogue version Socket D-Sub HD15 Pin Assignment Analogue control unit Bus actuation 11 1

1 Not connected Not connected

2 Not connected Not connected

3 Actual value output + Not connected

4 Binary input 2

5 12 V-Output (only for internal company use)

6 RS232 TxD (direct connection to computer)

7 Binary input 1

8 GND (for binary inputs)

9 only company internal use (do not connect!) 10 12 V-Output (only for internal company use) 11 12 V-Output (only for internal company use)

12 Binary input 3

13 Actual value output GND Not connected

14 RS232 RxD (direct connection to computer)

15 DGND (for RS232-interface)

Socket M16, round, 8 pin Pin Assignment 5 4 1 24 V-supply +

2 Relay 1 – reference contact

3 Relay 2 – reference contact

4 Relay 1 – normally closed contact

5 Relay 1 – normally open contact

7 Relay 2 – normally open contact

8 Relay 2 – normally closed contact

Socket D-Sub 9 pin Pin Assignment PROFIBUS DP CANopen

1 Shield Shield

2 Not connected CAN-L data line

3 RxD/TxD - P (B-line) GND

4 RTS (control signal for

repeater) Not connected

5 GND Not connected

6 VDD (only for termination

resistor) Not connected

7 Not connected CAN-H data line

8 RxD/TxD - N (A-line) Not connected

9 Not connected Not connected

7 | 11 Visit product website  Note: Optional P in 7 and 8 with bus version as transmitter input possible. The cable length for RS232/ actual value signal is limit ed to 30 meters. PROFIBUS DP – socket B-coded M12 (DPV1 max. 12 Mbaud) Pin Assignment 3 2

1 VDD (only for termination resistor)

2 RxD/TxD – N (A-line)

3 DGND

4 RxD/TxD – P (B-line)

5 Not connected

CANopen – Plug A-coded M12 Pin Assignment

1 Shield

2 Not connected

4 CAN_H

5 CAN_L

  1. P roduct operation 5.1. Measuring principle
  • The sensor measur es the flow by means of differential pressure. An orifice in the main channel causes pressure loss at liquid flow which is measured by the differential pressure sensor. The sensor feedbacks a precise and temperature compensated signal out of which the electronics calculates the corresponding flow. T o avoid a blockage of the aperture by contaminated mediums an upstream filter is recommended. p1 p2 5 10 15bar 0 5 10 15bar

8 | 11 Visit product website  6. Or dering information 6.1. Bürk ert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and fast delivery You want to find your desired Bürkert product or spare part quickly and order dir ectly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 6.2. Recommendation r egarding product selection Note: The decisive factors for the perfect functioning of an LFM within the application are the fluid compatibility, the pressure range and the correct choice of the flow meter range. The pressure loss over the LFM averages in typical applications approx. 500 mbar, with up to 2 barg inlet pressure. The specification of the inlet pressure, p1max, which can be expected is necessary for the selection of the suitable differential pressure sensor. Please use the „Product Enquiry Form“ at the end of this document to indicate the pressures directly before and after the LFM. If these are unknown or not accessible to a measurement, estimates are to be made by taking into account the approximate pressure drops over the flow resistors before and after the LFM, respectively, at a flow rate of Q Nom. In addition, please quote the maximum in- let pressure p1 max. to be encountered. This data is needed to make sure the actuator is able to provide a close-tight function within all the specified modes of operation. 6.3. Bürk ert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter

9 | 11 Visit product website  6.4. Or dering chart accessories Note: The adapters serve mainly for initial operation or diagnosis. Those are not obligatory for continuous operation. Description Article no. Connections/Cables Round plug M16, 8 pin (solder connection) 918299  Round plug M16, 8 pin with 5 m cable 787733  Round plug M16, 8 pin with 10 m cable 787734  Plug D-Sub HD15, 15 pin with 5 m cable 787735  Plug D-Sub HD15, 15 pin with 10 m cable 787736  Adapters1.) RS232 adapter for connection to a computer, connection with an extension cable (Article no. 917039 ) 654757  Extension cable for RS232 9 pin socket/plug 2 m 917039  RS422-Adapter (RS485-kompatibel) 666370  USB-Adapter 670696  USB connection cable 2 m 772299  Adapter for manual setting of bus address 667525  Communication software Mass Flow Communicator LINK Accessories for Fieldbus PROFIBUS-DP (B-coded) Plug M12 2.) 918198  Socket M12 (coupling)2.) 918447  Y-junction2.) 902098  T-junction 918531  Termination resistor 902553  GSD-File (PROFIBUS), EDS-File (CANopen) LINK C ANopen (A-coded) Plug M122.) 917115  Socket M12 (coupling)2.) 917116  Y-Stück2.) 788643  T-junction On request Termination resistor On request GSD-File (PROFIBUS), EDS-File (CANopen) LINK 1.) The adapt ers serve mainly for initial operation or diagnosis. Those are not obligatory for continuous operation. 2.) The M12 single connect ors as listed here are not suitable for their simultaneous use with the Y-piece for reasons of space. Please always use at least one commercially available overmoulded cable whose connector is usually smaller.

10 | 11 Visit product website  6.5. Adapt er sketch M12 P-DP: 918 198 CAN: 917 115 USB adapter 670 696 RS422 adapter 666 370 Female M12 with cable M12 P-DP: 918 198 CAN: 917 116 OR RS232 adapter 654 757 Adapter for manual setting of a bus address 667 525 M12 P-DP: 918 447 CAN: 917 116 Shut-off resistor P-DP: 902 553 (male) CAN: on request Male M12 with cable T junction P-DP: 918 531 CAN: on request Y junction P-DP: 902 098 CAN: 788 643

Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa Russia United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -

74653 Künzelsau

www.burkert.com

Mass Flow Controller for fluids 1 | 2Visit this product area on the website  © Christian Bürkert GmbH & Co. KG, subject to change Product Enquiry Form - Mass Flow Controller For Fluids Thank you for your interest in our products! In order to provide you with optimum advice, please fill out the following form and send it to your Bürkert representative or e-mail address: info@burkert.com. All information submitted will of course be kept strictly confidential. Please fill in the required fields! * *Note: The interactive functions of this PDF may be restricted depending on the PDF reader used. Personal Information Company Contact person Customer no. Department Street Postcode / Town Telephone no. Email Delivery Quantity Requir ed delivery date Medium data Type of liquid or liquid mixture Dynamic viscosity mP as Medium temperature ºC ºF Ambient temperature ºC ºF Fluidic data Flow range Q Nom Min. M a x . unit Inlet pressure at QNom p1 = barg1.) Outlet pressure at QNom p2 = barg1.) Max. inlet pressure p1max = barg1.) Port connection Compr ession fitting Subbase V acuum fitting Thr ead: G (DIN ISO 228/1) NPT (ANSI B1.2) Installation horizontal, sensor upwar ds ver tical, upward flow horizontal, sensor downwar ds ver tical, downward flow 1.) Please indicate all pressure values as overpressure to atmospheric pressure [barg] (g = relative pressure) Material specifications Seals F F K M EPDM Electrical data Control / Communication Note: Please choose one of the following op- tions! Normsignal CANopen/büS 0 … 5 V CANopen 0 … 10 V büS 0 … 20 mA 4 … 20 mA Approvals / Conformities UL A TEX II Cat. 3 G/D, IECEx USP Class VI conformity FD A conformity EG 1935/2004 conformity

Mass Flow Controller for fluids 2 | 2Visit this product area on the website  © Christian Bürkert GmbH & Co. KG, subject to change Additional Requirements / Comment