Visit product website  DATA SHEET Type 8652  AirLINE - the valve island optimised for process automation Type ME43  Fieldbus gateway Type 2012  Pneumatically operated 2/2-way globe valve CLASSIC Type 2100  Pneumatically operated 2/2-way angle seat valve ELEMENT for decentralized automation Type 8920  Bürkert Communicator Type 8697  Pneumatic control for decentralised automation of ELEMENT process valves Standard | EU | en | 2023 - 10 - 02 | 04 AirLINE Field – the valve island – optimised for process automation

  • Fieldbus interface CANopen, IO-Link or büS (Bürkert System Bus) Easy diagnostics via LC display Process reliability through pneumatic functions Optimised for installation in the field (IP65/67) The valve island Type 8653 AirLINE Field has been especially developed for appli- cations in process automation. New diagnostic functions can be visualised at the LC display, both in clear text and as symbols. This facilitates assignment of the displayed messages and helps to save time during start-up and maintenance. Furthermore the diagnostic message is also available in the controller. This there- fore enables a fast overview of the plant status. The hardware design has been optimised for installation close to the actuator. Thus, an intelligent installation system allows the valve island to be installed in a wide variety of positions. Need- less to say, straightforward installation on the DIN rail is also possible. Moreover, key pneumatic functions ensure increased process reliability. For instance, the non-return valves in the exhaust air ducts make sure there is no unplanned actua- tion due to pressure peaks. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 8653 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 14Visit product website  Table of contents 1. General technical data 3 Circuit functions Approvals and conformities 3.2. Conformity 3.3. Standards 3.4. North America (USA/Canada) 4. Materials 5 5. Dimensions 6 Device/Process connections büS/CANopen version IO-Link version 7. Product design and assembly 7 8. Product accessories 8 9. Ordering information 9 9.2. Bürkert product filter 9.3. Ordering chart Ordering chart Type 8653 büS version Ordering chart Type 8653 CANopen version Ordering chart IO-Link version 9.4. Ordering chart accessories Fieldbus gateway Type ME43 Accessory for Software Bürkert Communicator

3 | 14Visit product website  1. General technical data Product properties Dimensions Further information can be found in chapter “5. Dimensions” on page 6 Material Body PPA Seal NBR and PUR Maximum installation width of a valve island 48.6 mm. Further information can be found in chapter “5. Dimensions” on page 6 Width per station 11 mm Manual override Latching, spring return (optional: lockable) Number of valve positions Max. 4 Maximum number of valve functions Max. 8 Switching function/Operating principle Further information can be found in chapter “2. Circuit functions” on page 4 Pneumatic intermediate supply N/A Performance data Pressure data Overpressure to atmospheric pressure Pressure range Vac.…8 bar External supply air (auxiliary pilot air) 3…8 bar Flow rate QNn value air 310 l/min 1.) measured at + 20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure Flow rate QNn value air with integrated P shut-off N/A Nominal operating mode Continuous operation (100 % duty cycle) Switching time Measured according to ISO 12238 Electrical data Operating voltage 24 V DC Voltage tolerance ± Residual ripple (at DC) 1 Vss Nominal power of each valve 0.7 W (0.1 W after power reduction) Nominal current of each valve 29 mA (10 mA after power reduction) Position feedback Possible via 8-DI module Type ME44 or 16-DI module Type ME6 Protection class III according to DIN EN 61140, VDE 0140 Total current With fieldbus connection Current consumption < 400 mA Medium data Operating medium Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended) Compressed air quality ISO 8573 1:2010, Class 7.4.4 Approvals and conformities Degree of protection IP65, IP67 North America (USA/Canada) Further information can be found in chapter “3.4. North America (USA/Canada)” on page 5 Process/Port connection & communication Working port D 6, D Air supply connection D 8, D Communication module ME43 or ME63 (Gateway) Communication interface PROFIBUS DP Industrial Ethernet (PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic) CANopen büS (for networking with Bürkert devices) Environment and installation Installation position Any Storage temperature - 10…+ Ambient temperature - 10…+ Accessories Bürkert Software 2.) Software Bürkert Communicator Further information can be found in chapter “8.1. Bürkert Communicator Software” on page 1.) The maximum flow rate depends on the valve function. 2.) For commissioning, the Bürkert Communicator software Type 8920  as well as the associated USB büS interface set 1 with Article no. 772426  are required.

4 | 14Visit product website  2. Circuit functions Symbol Description 1 5 1 3 Circuit function C (CF C) 2 x 3/2-way solenoid valve Servo-controlled, with manual override Normally closed 1 5 1 3 Circuit function D (CF D) 2 x 3/2-way solenoid valve Servo-controlled, with manual override Normally open 4 2 5 1 3 Circuit function H (CF H) 5/2-way solenoid valve Servo-controlled, with manual override Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. 14 12 4 2 5 1 3 Circuit function L (CF L) 5/3-way solenoid valve With manual override In middle position all ports locked 5 1 3 14 12 4 2 Circuit function M (CF M) 5/3-way solenoid valve With manual override In middle position ports 2 and 4 ventilated 14 12 4 2 5 1 3 Circuit function N (CF N) 5/3-way solenoid valve With manual override In middle position ports 2 and 4 exhausted 14 12 4 2 5 1 3 Circuit function Z (CF Z) 5/2-way solenoid valve Impulse version with 2 coils and manual override Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure.

5 | 14Visit product website  3. Approvals and conformities 3.1. General notes

  • The approvals and conformities listed below must be stated when making enquiries. This is the only way to ensure that the pro duct complies with all required specifications. Not all available versions can be supplied with the below mentioned approvals or conformities. 3.2. Conformity In accordance with the Declaration of conformity, the product is compliant with the EU Directives. 3.3. Standards The applied standards which are used to demonstrate compliance with the EU Directives are listed in the EU-Type Examination Certificate and/or the EU Declaration of Conformity. 3.4. North America (USA/Canada) Approval Description Optional: UL Listed for the USA and Canada The products are UL Listed for the USA and Canada according to: UL 61010 1 (ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE – Part 1: General Requirements) CAN/CSA-C22.2 No. 61010 4. Materials 4.1. Bürkert resistApp Bürkert resistApp – Chemical resistance chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start chemical resistance check

6 | 14Visit product website  5. Dimensions Note: Dimensions in mm, unless otherwise stated 48.6 103.55 126.4 138.5 6.35 82.2 35.5 11.04 4.1 108.9 29.25 61 6.5 14 4.3 2.5 Hose connection ø6 mm (alternative 1 of 2) 4.3 4.3 Hose connection ø8 mm Hose connection ø8 mm 6.35 8.8 11.04 Hose connection ø1/4" (alternative 2 of 2)

7 | 14Visit product website  6. Device/Process connections 6.1. Assignment of circular plug M12, 5-pin büS/CANopen version Assignment of circular plug M12, 5-pin, A-coded, büS/CANopen variant View of pins Pin Assignment 1 3

1 SHIELDING

2 Supply voltage 24

V

3 GND

4 CAN_H (büS connection)

5 CAN_L (büS connection)

Assignment of circular plug M12, 5-pin, A-coded, IO-Link variant, Port Class B View of pins Pin Assignment 1 3

1 L+ (24 V processor)

2 P24 (24

V valve unit)

3 L- (0

V GND processor)

4 C/Q (IO-Link)

5 N24 (0

V GND valve unit) 7. Product design and assembly 7.1. Example configuration The following graphic shows a network with the example of Fieldbus Gateway Type ME43 and AirLINE Field Type 8653 (büS version). Industrial Ethernet

24 V DC, GND, CAN_L, CAN_H

8 | 14Visit product website  8. Product accessories 8.1. Bürkert Communicator Software Note: The corresponding communication software can be downloaded from the website Type 8920 The Bürkert Communicator is the most important software component of the EDIP (Efficient Device Integration Platform). Various features of this universal tool simplify the configuration and parametrisation of devices equipped with a digital CANopen-based interface. With this tool the user has a complete overview of cyclic process values as well as acyclic diagnostic data. The integrated graphical programming environment enables the creation of decentralised sub-system control functions. The connection to the PC is established with a USB-CAN adapter. The adapter is available as an accessory (see “9.4. Ordering chart accessories” on page 14 The Bürkert Communicator enables: Configuration, parametrization and diagnosis of EDIP devices / networks Easy and comfortable mapping of cyclic values Graphical display of process values Firmware update for the connected EDIP devices Backup and restoring of device configurations

9 | 14Visit product website  9. Ordering information 9.1. Bürkert eShop Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 9.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter 9.3. Ordering chart Ordering chart Type 8653 büS version The following ordering chart lists the part numbers for Type 8653, subdivided according to connection type and circuit function. All valve positions are equipped with the same operating principle. Note: All articles in the following table are equipped with integrated check valves. Symbol QNn value air Switching times Article no. Article no. Opening Closing D6/D8 D¼"/ 5/16" [l/min] [ms] [ms] C (CF C) 2 x 3/2-way solenoid valve Servo-controlled, with manual override Normally closed 1 5 1 3 270 15 15 309522  309537  D (CF D) 2 x 3/2-way solenoid valve Servo-controlled, with manual override Normally open 1 5 1 3 310 15 15 377659  o. r.

10 | 14Visit product website  Symbol QNn value air Switching times Article no. Article no. Opening Closing D6/D8 D¼"/ 5/16" [l/min] [ms] [ms] H (CF H) 5/2-way solenoid valve Servo-controlled, with manual override Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. 4 2 5 1 3 270 20 25 309529  338890  L (CF L) 5/3-way solenoid valve With manual override In middle position all ports locked 14 12 4 2 5 1 3 290 20 25 20030510  o. r. M (CF M) 5/3-way solenoid valve With manual override In middle position ports 2 and 4 ventilated 5 1 3 14 12 4 2 290 20 25 o. r. o. r. N (CF N) 5/3-way solenoid valve With manual override In middle position ports 2 and 4 exhausted 14 12 4 2 5 1 3 290 20 25 o. r. o. r. Z (CF Z) 5/2-way solenoid valve Impulse version with 2 coils and manual override Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. 14 12 4 2 5 1 3 290 20 25 20058986  o. r. o. r. = on request

11 | 14Visit product website  Ordering chart Type 8653 CANopen version The following ordering chart lists the part numbers for Type 8653, subdivided according to connection type and circuit function. All valve positions are equipped with the same operating principle. Note: All articles in the following table are equipped with integrated check valves. Symbol QNn value air Switching times Article no. Article no. Opening Closing D6/D8 D¼"/ 5/16" [l/min] [ms] [ms] C (CF C) 2 x 3/2-way solenoid valve Servo-controlled, with manual override Normally closed 1 5 1 3 270 15 15 309527  338914  D (CF D) 2 x 3/2-way solenoid valve Servo-controlled, with manual override Normally open 1 5 1 3 310 15 15 o. r. o. r. H (CF H) 5/2-way solenoid valve Servo-controlled, with manual override Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. 4 2 5 1 3 270 20 25 309532  338917  L (CF L) 5/3-way solenoid valve With manual override In middle position all ports locked 14 12 4 2 5 1 3 290 20 25 o. r. o. r. M (CF M) 5/3-way solenoid valve With manual override In middle position ports 2 and 4 ventilated 5 1 3 14 12 4 2 290 20 25 o. r. o. r. N (CF N) 5/3-way solenoid valve With manual override In middle position ports 2 and 4 exhausted 14 12 4 2 5 1 3 290 20 25 o. r. o. r.

12 | 14Visit product website  Symbol QNn value air Switching times Article no. Article no. Opening Closing D6/D8 D¼"/ 5/16" [l/min] [ms] [ms] Z (CF Z) 5/2-way solenoid valve Impulse version with 2 coils and manual override Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. 14 12 4 2 5 1 3 290 20 25 o. r. o. r. o. r. = on request Ordering chart IO-Link version The following ordering chart lists the part numbers for Type 8653, subdivided according to connection type and circuit function. All valve positions are equipped with the same operating principle. Note: All articles in the following table are equipped with integrated check valves. Symbol QNn value air Switching times Article no. Article no. Opening Closing D6/D8 D¼"/ 5/16" [l/min] [ms] [ms] C (CF C) 2 x 3/2-way solenoid valve Servo-controlled, with manual override Normally closed 1 5 1 3 270 15 15 357762  373702  D (CF D) 2 x 3/2-way solenoid valve Servo-controlled, with manual override Normally open 1 5 1 3 310 15 15 20002355  o. r. H (CF H) 5/2-way solenoid valve Servo-controlled, with manual override Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. 4 2 5 1 3 270 20 25 370110  373703  L (CF L) 5/3-way solenoid valve With manual override In middle position all ports locked 14 12 4 2 5 1 3 290 20 25 382177  o. r.

13 | 14Visit product website  Symbol QNn value air Switching times Article no. Article no. Opening Closing D6/D8 D¼"/ 5/16" [l/min] [ms] [ms] M (CF M) 5/3-way solenoid valve With manual override In middle position ports 2 and 4 ventilated 5 1 3 14 12 4 2 290 20 25 o. r. o. r. N (CF N) 5/3-way solenoid valve With manual override In middle position ports 2 and 4 exhausted 14 12 4 2 5 1 3 290 20 25 o. r. o. r. Z (CF Z) 5/2-way solenoid valve Impulse version with 2 coils and manual override Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. 14 12 4 2 5 1 3 290 20 25 371372  o. r. o. r. = on request

14 | 14Visit product website  9.4. Ordering chart accessories Fieldbus gateway Type ME43 Note: Please note that the ME43 gateway modules are not configured ex works. However, these absolutely must be configured in order to be used in a system. The device description files must be generated with the Bürkert Communicator software before the start-up of a system. Further information can be found in the operating instructions Type ME43 Description Article no. Industrial Ethernet gateway (PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT®) 307390 PROFIBUS gateway (PROFIBUS DPV1) 307393 Gateway büS/CANopen 307391 Gateway CC Link 307394 Accessory for Software Bürkert Communicator Description Article no. büS cable extension, M12, cable length: 0.1 m 772492 büS cable extension, M12, cable length: 0.2 m 772402 büS cable extension, M12, cable length: 0.5 m 772403 büS cable extension, M12, cable length: 1 m 772404 büS cable extension, M12, cable length: 3 m 772405 büS socket, M12, straight, A-coded 772416 büS plug, M12, straight, A-coded 772417 büS socket, M12, angled, A-coded 772418 büS plug, M12, angled, A-coded 772419 büS Y plug 772420 büS Y plugfor linking 2 separately supplied segments of a büS network 772421 Termination resistor (directly pluggable) 303833 büS plug, M12, terminating resistor 120 Ω 772424 büS socket, M12, terminating resistor 120 Ω 772425 Power supply unit Phoenix Class2 (Type 1573), 85…240 V AC/24 V DC, 1.25 A, NEC Class 2 (UL 1310) 772438 Power supply unit for standard rail (Type 1573), 100…240 V AC/24 V DC, 1 A, NEC Class 2 (UL 1310) 772361 Power supply unit for standard rail (Type 1573), 100…240 V AC/24 V DC, 2 A, NEC Class 2 (UL 1310) 772362 Power supply unit for standard rail (Type 1573), 100…240 V AC/24 V DC, 3.8 A, NEC Class 2 (UL60950 1) 772898 Power supply unit for standard rail (Type 1573), 100…240 V AC/24 V DC, 10 A 772698 microSD card 774087 USB büS interface set 1 (Type 8923) for connection to the Bürkert Communicator software: includes connection cable (M12 and micro USB), stick with integrated terminating resistor, power supply and software 772426 USB büS interface set 2 (Type 8923) for connection to the Bürkert Communicator software: including büS stick, connection cable to M12 plug, M12 connection cable on micro USB for the büS service interface and Y distributor, cable length: 0.7 m 772551 License for graphical programming (only required for a running time > 60 minutes) 567713 Software Bürkert Communicator Type 8920 1.) Due to lack of space, the M12 single connectors may not be suitable for their simultaneous use on the same side of the Y connector. Please use the available ready-made assem- bled cable in this case.