8189 BURKERT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 12

Technical content

Visit product website  DATA SHEET Type 8619  multiCELL - Multi-chan- nel and multi-function transmitter/controller Type 8611  eCONTROL - Universal controller Type 8802  ELEMENT continuous control valve systems - overview Type 8644  Remote Process Actu- ation Control System AirLINE Type 8793  Digital electropneumat- ic Process Controller SideControl 1000244852 | Standard | EU | en | 202109 | 04 Level measurement device with guided radar - sanitary version

  • Universal level measurement device for liquids
  • Liquid interface measurement
  • Insensitive to dust and steam
  • 4... 20 mA/Hart, 2 wires
  • ATEX/IECEx certifications The Type 8189 is a level measurement device with interchangeable rod probe, designed for continuous level measurement. The unit is suitable for liquids, for industrial use in all areas of process tech- nology. But the main application targets are in Food and Beverage (F&B) and pharmaceutical tanks to the new rod in stainless steel 1.4435 with Ra < 0.76 µm. For applications with corrosive liquids a PFA coated version is available. Even process conditions such as strong steam generation, density fluctua- tions or changes of the dielectric constant do not influence the accuracy of the measurement. Build-up or condensation on the probe or vessel wall does not influence the measurement result. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 8189 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 12 Visit product website  Table of contents 1. General technical data 3 Approvals 2.2. Certificates 3. Materials 5 4. Dimensions 6 4.2. With process connection according to DIN 11851 5. Performance specifications 8 5.2. Measurement deviation diagram Rod probe version in water Rod probe version in oil 5.3. Temperature derating diagram 6. Product operation 9 6.2. Product operation notes Set up with display/configuration module Set up with PACTware™/DTM and HART communication 7. Ordering information 10 7.2. Bürkert product filter 7.3. Ordering chart 7.4. Ordering chart accessories

3 | 12 Visit product website  1. General technical data Product properties Materials Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page Non wetted parts Housing Plastic PBT (Polyester) and stainless steel 316L (1.4404) Cover PC transparent Seal between housing and cover EPDM Cable gland PA Blind plug PA Ground terminal Stainless steel 316L Wetted parts Process connection Stainless steel 316L (1.4404 or 1.4435) and PEEK Process seal EPDM Rod-Ø 8 mm Stainless steel 316L (1.4435), polished Dimensions Detailed information can be found in chapter “4. Dimensions” on page 6 Weights • Housing: 890 g

  • Rod-Ø 8 mm: approx. 400 g/m Surface quality Rod: Ra 0.76 µm (with low delta ferrite content) Probe length 0.3…4 m (lateral load:

10 Nm)

Measured variable Level of liquids Measuring range 0.08…4 m Detailed information can be found in chapter “5.1. Measuring range and blocking distance diagram” on page 8 Damping (63 % of the input variable) 0…999 s, adjustable Step response time1.) ≤ 3 s Product accessories Display LCD in full dot matrix. Detailed information can be found in chapter “7.4. Ordering chart accessories” on page 11 Performance data Blocking distance • In water: – from top of probe: 80 mm – from bottom of probe: 0 mm

  • In oil – from top of probe: 150 mm – from bottom of probe: 100 mm Measurement deviation2.)3.) According to DIN EN 60770-1: ± 2 mm Detailed information can be found in chapter “5.2. Measurement deviation diagram” on page Measuring range resolution < 1 mm Measuring cycle time < 500 ms Temperature drift • Digital output: 3 mm/10 max. 10 mm
  • Current output: 0.03 %/10K relating to the 16 mA span or 0.3 Max. filling/emptying speed 1 m/min (products with high dielectric constant 10) up to 5 m/min.) Non-repeatability ≤ 1 mm Vibration resistance 1 g with 5…200 Hz according to EN 60068 (vibration at resonance) with rod length 50 cm Shock resistance 25 g, 6 ms according to EN 60068 (mechanical shock) with rod length 50 cm

4 | 12 Visit product website  Electrical data Operating voltage (Un) • Without display/configuration module: – 9.6…35 V DC – 9.6…30 V DC (Ex ia instrument)

  • With display/configuration module: – 16…35 V DC – 16…30 V DC (Ex ia instrument) Power source (not supplied) Limited power source according to UL/EN 60950 1 standards or limited energy circuit according to UL/EN 61010 1 §9.4 Starting current ≤ 3.6 mA, 10 mA for 5 ms after the switching on DC reverse polarity protection Yes Output signal 4…20 mA/HART Signal resolution 0.3 µA Range of the output signal 3.8…20.5 mA/HART (default setting) Load resistor (Un - Umin.)/0.022 A Fault signal Current output: last valid measured value, 21 mA or 3.6 mA (adjustable) Max. output current 21.5 mA Residual ripple (for DC) • For 9.6 V Un < 18 V: ≤ 0.7 Veff (16…400 Hz)
  • For 18 V Un < 35 V: ≤ 1.0 Veff (16…400 Hz) Voltage supply cable • Cable diameter: 5…9 mm
  • Wire cross-section (spring-loaded terminals): – Massive wire, stranded wire: – Stranded wire with end sleeve: Medium data Process temperature - 20…+ 130 4…+ 266 °F) (for sterilisation process: up to 150 302 °F) for max. 120 min) Process pressure Vessel pressure: 1…16 bar 14.51…232.16 PSI/- 100…1600 kPa) Dielectric constant (min.) εr 1.6 Product connections Process connection • Clamp 2"
  • DIN 11851 DN 50 Electrical connections Cable gland M20 x 1.5 Approvals and Certificates Standards Degree of protection according to IEC/EN 60529 IP66/IP67 with cable plug mounted and tightened M20 x 1.5 Overvoltage category according to IEC 61010 Category III Protection class according to IEC 61010 Class III Directives CE directives The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable) NAMUR recommendations • NE21 – Electromagnetic compatibility of equipment
  • NE43 – Signal level for fault information from measuring transducers
  • NE53 Compatibility of field devices and display/adjustment components
  • NE107 Self-monitoring and diagnosis of field devices Certificate FDA declaration of conformity. Detailed information can be found in chapter “2.2. Certificates” on page Certifications ATEX/IECEx EN IEC 60079 EN 60079 11, EN 60079 Detailed information can be found in chapter “2.1. Certifications” on page Environment and installation Ambient temperature Operation and storage: 40…+ 40…+ 176 °F) (with display/configuration module) Temperature derating Detailed information can be found in chapter “5.3. Temperature derating diagram” on page

5 | 12 Visit product website  Relative air humidity • Operation: max. 75 %, without condensation

  • Storage: 20…85 %, without condensation Height above sea level Max. 2000 m (by default; max. 5000 m with connected overvoltage protection) Pollution degree Degree (when used with fulfilled housing protection) 1.) Time span, after a sudden change in the measuring distance of max. 0.5 m in liquid applications, until the output signal has assumed for the first time 90 % of the final value (IEC 61298 2). 2.) Depending on the mounting conditions, deviations can occur which can be rectified by adapting the adjustment or changing the measured value offset in the DTM service mode. 3.) The blocking distances can be optimized by a false signal suppression. 2. Approvals 2.1. Certifications Note: Devices with Ex certification have different technical data, see Supplement ATEX/IECEx Type 8189  under user manual. Certificate Description EU-Type Examination Certificate Number: TÜV 19 ATEX 260229X / IECEx TUN 19.0021X ATEX
  • II 1G Ex ia IIC T6…T1 Ga resp.
  • II 1/2G Ex ia IIC T6…T1 Ga/Gb resp.
  • II 2G Ex ia IIC T6…T1 Gb IECEx
  • Ex ia IIC T6…T1 Ga resp.
  • Ex ia IIC T6…T1 Ga/Gb resp.
  • Ex ia IIC T6…T1 Gb Measures to comply with ATEX/IECEx requirements: refer to the Supplement ATEX/IECEx Type 8189  under user manual. The Ex. certification is only valid if the Bürkert device is used as described in the supplement ATEX/IECEx. If unauthorized changes are made to the device, the Ex. certification becomes invalid. 2.2. Certificates Certificate Description FDA FDA The devices comply in their composition with the Code of Federal Regulations published by the FDA (Food and Drug Administration, USA). 3. Materials 3.1. Chemical Resistance Chart – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check

6 | 12 Visit product website  4. Dimensions 4.1. With clamp process connection Note: Dimensions in mm (unless specified differently) 123 174.6 L øW ø 8 mm ø 91 ø 80.5 approx. 75.5 M20 x 1.5 cable gland M20 x 1.5 closing screw AF27 AF10 Clamp connection Ø W L 2" 64.0 2½" 77.5 3" 91.0

7 | 12 Visit product website  4.2. With process connection according to DIN 11851 Note: Dimensions in mm (unless specified differently) ø 91 ø 80.5 123 174.6 approx. 75.5 L øW øX ø 78 ø 8 M20 x 1.5 cable gland M20 x 1.5 closing screw AF27 AF10 DIN 11851 connection Ø W Ø X L DN 32 50.0 Rd 58 1/6 0.3…4 m DN 40 56.0 Rd 65 DN 50 68.5 Rd 78 DN 65 86.0 Rd 58

8 | 12 Visit product website  5. Performance specifications 5.1. Measuring range and blocking distance diagram No. Description

1 Reference plane –

2 Measuring probe length 0.3…4 m

3 Measurement range In

water: 0.08…4 m In oil: 0.15…3.95 m

4 Upper block distance In

water: 0.08 m In oil: 0.15 m

5 Lower block distance In

water: 0 m In oil: 0.1 m 5.2. Measurement deviation diagram Rod probe version in water Note: The blocking distance is indicated by the grey area in the diagram. No measurement is possible in this area. Probe length 0.20.08 0.04 15 mm 2 mm -2 mm -15 mm [mm] [m] Measuring range Blocking distance Measuring deviation

9 | 12 Visit product website  Rod probe version in oil Note: The blocking distance is indicated by the grey area in the diagram. No measurement is possible in this area. Probe length 0.350.15 0.05 15 mm 2 mm -2 mm -15 mm -10 mm 0.1 [mm] Blocking distance Measuring deviation [m] Measuring range Blocking distance 5.3. Temperature derating diagram Process temperature [°C] Ambient temperature [°C] 10 20 30 40 50 60 70 80 90 100 110 120 -30 -20 -10 0-30 -20 -10 -40 -40 130 150 140 6. Product operation 6.1. Measuring principle High frequency microwave pulses are guided along a rod. When they reach the product surface, the microwave pulses are reflected and received by the processing electronics. The running time is evaluated by the instrument and outputted as distance. Time con suming adjustment with medium is not necessary. The instruments are pre-set to the ordered probe length. The shortenable rod version can be adapted individually to the local requirements. 6.2. Product operation notes Note: The measuring device can be adjusted with:

  • The display/configuration module
  • The suitable Bürkert DTM in conjunction with a software according to the FDT/DTM standard, e.g. PACTware™ and PC
  • With a HART handheld The entered parameters are generally saved in the measuring device Type 8189. Optionally, parameters may also be uploaded and downloaded with the display/configuration module or saved in a file by using PACTware™/8189 DTM.

10 | 12 Visit product website  Set up with display/configuration module Display/configuration module Description The display/configuration module can be inserted into the measuring device and removed again at any time. It is not necessary to interrupt the power supply. The measuring device is adjusted via the four keys of the display/configuration module. Set up with PACTware™/DTM and HART communication Assembly Description PACTwareTM Bürkert DTM Power supply unit1 The measuring device can be operated thanks to PACTware™, via HART communication. An interface adapter is necessary for the adjustment with PACTware™. For the setup of the Type 8189, the DTM in the actual version must be used. The basic version of DTM incl. PACTware™ is available as a free-of-charge download from the internet at www.burkert.com Connecting the PC via HART No. Description

1 Measuring device Type 8189

2 HART-USB Modem

3 Resistance

250 Ω Necessary components:

  • Measuring device Type 8189
  • PC with PACTware™ and suitable Bürkert DTM
  • HART-USB Modem
  • Resistance approx. 250 Ω
  • Power supply unit 7. Ordering information 7.1. Bürkert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and fast delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now

11 | 12 Visit product website  7.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter 7.3. Ordering chart Note: All following versions are supplied with display/configuration module. Description Operating voltage Output Probe Length Electrical connection Article no. Standard version Clamp 2" 9.6…35 V DC 4…20 mA/HART (2 wires) Rod 1 m Cable gland M20 1.5 565850  2 m 565852  DIN 11851, DN 50 1 m 565851  2 m 565853  Ex version ATEX certification Clamp 2" 9.6…30 V DC 4…20 mA/HART (2 wires) Rod 1 m Cable gland M20 1.5 565854  2 m 565856  DIN 11851, DN 50 1 m 565855  2 m 565857  Ex version IECex certification Clamp 2" 9.6…30 V DC 4…20 mA/HART (2 wires) Rod 1 m Cable gland M20 1.5 565858  2 m 565860  DIN 11851, DN 50 1 m 565859  2 m 565861  Further versions on request Material FFKM Temperature 20…+ 150 Process connection

  • Clamp 1½", 2½", 3"
  • DIN 11851 DN 32, DN 40, DN 65 Additional Without display/configuration module 7.4. Ordering chart accessories Description Article no. Set with reductions M20 1.5/NPT ½" neoprene flat seals for cable gland screw-plugs M20 1.5 551782  Hart-USB Modem 560177  Set with a display/configuration module, a transparent cover and a seal ring 559279  Set with a transparent cover and a seal ring 561006 

Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa Russia United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -

74653 Künzelsau

www.burkert.com