Visit product website DATA SHEET Type 8611 eCONTROL - Universal controller Type 8619 multiCELL - Multi-channel and multi-function transmitter/controller Type 8802 ELEMENT continuous control valve systems - overview Type 8644 AirLINE SP electropneu- matic automation system Standard | EN | en | 2023-12-18 | 05 Inline positive displacement (PD) flowmeter or Inline batch controller
- Display for indication of flow rate and volume with two totalizers or dosing Automatic calibration using Teach-In Inputs (with batch controller) and all outputs can be checked without the need for actual flow Total and day counters for batch quantity and number of dosing, volume or mass counter indicator (with batch controller) The device Type SE35 + S077 is specially designed for continuous flow measure- ment of highly viscous fluids like glue, honey or oil. slightly aggressive, solid-free liquids. The device is provided as flowmeter or batch controller. The device is made up of a compact Inline sensor-fitting with oval gears (Type S077) and a transmitter with display (Type SE35). The device is quickly and easily assem- bled thanks to a bayonet mounting and locking system. The Bürkert “Inline quar - ter-turn” technology ensures a leakage-free operation. The Bürkert designed sensor-fitting system ensures simple installation of the devices into all pipelines from DN 15…DN 100. The flowmeter is specially designed to switch a valve and to establish a monitoring system or an On/Off control loop. The batch controller is designed to carry out a dosing of one or several quantities of liquids, when mounted in series in a pipe with one or two valves. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type SE35 + S077 © Christian Bürkert GmbH & Co. KG, Änderungen vorbehalten
2 | 20Visit product website Table of contents 1. General technical data 4 1.2. All variants .... 1.3. Flowmeter 1.4. Batch controller 2. Product versions 8 2.2. Batch controller 3. Approvals and conformities 9 3.2. Conformity ... 3.3. Standards .... 3.4. Pressure Equipment Directive (PED) .... Device used on a pipe 3.5. North America (USA/Canada) ... 4. Materials 9 4.2. Material specifications ... 5. Dimensions 11 With cable plug (DIN EN 175301 803) With M20 x 5.2. Transmitter Type SE35 mounted in an Inline sensor-fitting Type S077 .... 6. Product installation 12 7. Product operation 13 Flowmeter: 7.2. Functional overview Display and operating keys Flowmeter with a standard output signal Batch controller 7.3. Function modes Flowmeter with standard output signal Batch controller 8. Product design and assembly 17 9. Networking and combination with other Bürkert products 18 9.2. Batch controller 10. Ordering information 18
3 | 20Visit product website 10.3. Bürkert product filter 10.4. Ordering chart Flowmeter Batch controller 10.5. Ordering chart accessories ....
4 | 20Visit product website 1. General technical data 1.1. About the device The device Type SE35 + S077 is available as a Inline flowmeter or a batch controller in a compact variant. 1.2. All variants The following data are valid for both the Inline flowmeter and the batch controller. Product properties Material Make sure the device materials are compatible with the fluid you are using. Further information can be found in chapter “4.1. Bürkert resistApp” on page 9 Further information on the materials can be found in chapter “4.2. Material specifications” on page 10 Non wetted parts Lid PC Front panel film Polyester Cover PC Housing PC Screw Stainless steel Bayonet system PC Cable gland PA Wetted parts Axis Stainless steel 316L (1.4401) Oval gear Stainless steel 316L (1.4401) Sensor-fitting body Aluminium, stainless steel 316L (1.4401) Cover Aluminium, stainless steel 316L (1.4401) Seal FKM or FEP/PTFE encapsulated Display 15 mm, 8-digit LCD, alphanumeric,15 segments, 9 mm high Compatibility Any pipe from DN 15…DN 100 which is fitted with Bürkert S077 Inline sensor-fitting. For the selection of the nominal diameter of the Inline sensor-fittings, see data sheet Type S077 Pipe diameter DN 15…DN 100 Dimensions Further information can be found in chapter “5. Dimensions” on page 11 Measuring principle Oval gear Measuring range • Viscosity > mPa.s: 2…1200 l/min (0.53…320 gpm) Viscosity < mPa.s: 3…616 l/min (0.78…320 gpm) Performance data Measurement deviation • Teach-in or specific K factor, engraved on the Inline sensor-fitting: ± 0.5 % of the measured value at Teach-In flow rate value Standard K factor: ± % of the measured value Repeatability ± 0.03 % of the measured value 1.) Electrical data Power source (not supplied) Limited power source according to UL/EN 62368 1 standards or limited energy circuit according to UL/ EN 61010 1 paragraph 9.4 Protection against DC polarity reversal Yes Overvoltage protection Yes Voltage supply cable • Cable with maximum operating temperature greater than 80 °C (176 °F) (90 °C (194 °F) for UL Recognized variant) Max. 50 m length, shielded
5 | 20Visit product website Medium data Fluid temperature With Inline sensor-fitting Type S077 in: Aluminium: - 20…+ °C (- 4…+ 176 °F) Stainless steel: - 20…+ 120 °C (- 4…+ 248 °F) See data sheet Type S077 for more information. Fluid pressure With Inline sensor-fitting Type S077 with: DN 15: max. 55 bar (798.05 PSI) (threaded process connection) DN 25: max. 55 bar (798.05 PSI) 1.)
- DN 40 or DN 50: max. 18 bar (261.18 PSI) DN 80: max. 12 bar (174.12 PSI) DN 100: max. 10 bar (145.1 PSI) See data sheet Type S077 for more information. Viscosity Max. 1 Pa.s (higher on request) Rate of solid particles 0 Process/Pipe connection & communication Pipe connection With Inline sensor-fitting Type S077 with: Thread: ½", 1", 1½", 2" or 3" (G or NPT) Flange: 25, 40, 50, 80 or 100 mm DIN PN 16 flange 1", 1½", 2", 3" or 4" ANSI 150LB flange See data sheet Type S077 for more information. Approvals and conformities Directives CE directive Further information on the CE Directive can be found in chapter “3.3. Standards” on page 9 Pressure equipment directive Complying with article 4, paragraph 1 of 2014/68/EU directive Further information on the pressure equipment directive can be found in chapter “3.4. Pressure Equipment Directive (PED)” on page 9 North America (USA/Canada) UL Recognized for the USA and Canada Environment and installation Relative air humidity ≤ %, without condensation Height above sea level Max. 2000 m Operating condition Continuous Equipment mobility Fixed Application range Indoor and outdoor Protect the device against electromagnetic interference, ultraviolet rays and, when installed outdoors, against the effects of climatic conditions. Degree of protection 2.) according to IEC/EN 60529 IP65 with the following conditions met: device wired cover and lid screwed tight female cable plug or glands mounted and tightened with blind plug on unused cable glands Installation category Category I according to UL/EN 61010 Pollution degree Degree 2 according to UL/EN 61010 1.) Or in accordance to the value of the used flanges 2.) Not evaluated by UL
6 | 20Visit product website 1.3. Flowmeter Note: If the device is mounted in a humid environment or outside, then the maximum voltage allowed is 35 V DC instead of 36 V DC. Product properties Material Female cable plug/male fixed plug Body, contact holder and cable gland in PA Cable gland seal and flat seal in NBR Performance data 4…20 mA output uncertainty ± % of current range Electrical data Operating voltage (V+) • 12…36 V DC ± %, filtered and regulated Connection to main supply: permanent, through external SELV (Safety Extra Low Voltage) and LPS (Limited Power Source) power supply V AC, 50/60 Hz Voltage supply available inside the device: supplied voltage: 27 V DC regulated maximum current: 125 mA integrated protection: 125 mA time delay fuse Current consumption 12…36 V DC powered measuring device with standard output signal, with sensor and without pulse output consumption With relays: ≤ mA Without relay: ≤ mA Power consumption 115/230 V AC powered measuring device: 3 VA Output • Transistor (pulse): potential free NPN or PNP (wiring dependant) function: pulse output, adjustable pulse value 0…400 Hz 5…36 V DC, 100 mA, voltage drop at 100 mA: 2.5 V DC duty cycle (pulse duration/period): 0.5 galvanic insulation and protected against overvoltage, polarity reversals and short circuit Relay: 2 relays, normally open, hysteresis, adjustable thresholds non UL recognized device: 230 V AC/3 A or 40 V DC/3 A (resistive load) UL recognized device: 30 V AC/42 Vpeak/3 A or 60 V DC/1 A Current: 4…20 mA (3-wire with relays, 2-wire without relay) sourcing or sinking (wiring dependant) max. loop impedance: 900 Ω at 30 V DC, 600 Ω at 24 V DC, 50 Ω at 12 V DC, 800 Ω with a V AC voltage supply response time (10…90 %) for the measured value: 6 s (default) Voltage supply cable • External diameter (cable): 5…8 mm (with cable plug) 6…12 mm (1 cable per cable gland) or 3…5 mm when using a multi-way seal (2 cables per cable gland) Cross section of wires: 0.25…1.5 mm2 (with cable plug) 0.75 mm² (with cable gland) Cross section of the local ground wire: max. 0.75 mm² Process/Pipe connection & communication Electrical connection Cable plug according to DIN EN 175301 803 or cable glands M20 1.5
7 | 20Visit product website Environment and installation Ambient temperature Operation and storage: variant 12…36 V DC: 0…+ °C (+ 32…+ 140 °F) variant 115/230 V AC: 0…+ °C (+ 32…+ 122 °F) 1.4. Batch controller Note: If the device is mounted in a humid environment or outside, then the maximum voltage allowed is 35 V DC instead of 36 V DC. Electrical data Operating voltage (V+) • 12…36 V DC, max tolerance: - % or + % at 12 V DC, ± % at 36 V DC, filtered and regulated Connection to main supply: permanent, through external SELV (Safety Extra Low Voltage) and LPS (Limited Power Source) power supply V AC, 50/60 Hz Voltage supply available inside the device: supplied voltage: 27 V DC regulated maximum current: 125 mA integrated protection: 125 mA time delay fuse Current consumption With sensor, without consumption of digital input and pulse output With relays: 100 mA (at 12 V DC) mA (at 36 V DC) mA (115/230 V AC) Without relay: mA (at 12 V DC) mA (at 36 V DC) mA (115/230 V AC) Power consumption 115/230 V AC powered measuring device: 3 VA Input • DI (1 to 4) Switching threshold Von: 5…36 V DC Switching threshold Voff max.: 2 V DC Min. pulse duration: 100 ms Input impedance: 9.4 kΩ Galvanic insulation, protected against polarity reversals and voltage spike Output • Transistors (digital outputs DO1 and DO4): potential-free NPN or PNP (wiring dependant) function: pulse output (by default for DO1), batch state (by default for DO4), configurable and parametrisable 0…300 Hz 5…36 V DC, 100 mA max., voltage drop at 100 mA: 2.7 V DC duty cycle (pulse duration/period): > 0.45 galvanic insulation, protected against overvoltage, polarity reversals and short-circuits Relays (digital outputs DO2 and DO3): 2 relays, normally open, parametrisable (by default: DO2 always configured to control the valve, parametrized of 100 % of the batch quantity and DO3 configured as alarm) non UL recognized device: 230 V AC/3 A or 40 V DC/3 A (resistive load) UL recognized device: 30 V AC/42 Vpeak/3 A or 60 V DC/1 A max. cutting power of 750 VA (resistive load) Voltage supply cable • External diameter (cable): 6…12 mm (1 cable per cable gland) or mm when using a multi-way seal (2 cables per cable gland) Cross section of wires: 0.75 mm²
8 | 20Visit product website Process/Pipe connection & communication Electrical connection Cable glands M20 1.5 Environment and installation Ambient temperature Operation and storage: variant 12…36 V DC: 0…+ °C (+ 32…+ 140 °F) variant 115/230 V AC: 0…+ °C (+ 32…+ 122 °F) 2. Product versions 2.1. Flowmeter Flowmeter with standard output signal The device operates on a 2- or 3-wire system and needs a 12…36 V DC or a 115/230 V AC power supply. The device is equipped with: an analogue output (4…20 mA current output) a digital output (pulse output) and two totalizers. Some variants are also fitted with two fully configurable relay outputs. The device allows: through the digital or relay outputs to switch a solenoid valve to activate an alarm to generate a flow rate proportional frequency through the analogue output to establish a control loop 2.2. Batch controller The device needs a voltage supply of 12…36 V DC or 115/230 V AC. The device is equipped with: four digital inputs (DI1 to DI4), two transistor outputs (DO1 configured as a pulse output and DO4 configured as state output, by default), two relay outputs (DO2 always configured to control the valve and by default parametrise of 100 % of the batch quantity and DO3 configured as alarm output by default), two volume or mass totalizers and two totalizers for the number of batches performed. The second relay output can be used to activate another valve, to initiate alarms or to generate warnings. When mounted in a pipe in series with one or two valves, the batch controller makes it possible to carry out a dosing of one or several quantities of liquids. The unit controls the opening of the valves and measures the quantity of the fluid which flows. The unit also closes the valves when the pre-set quantity has been delivered.
9 | 20Visit product website 3. Approvals and conformities 3.1. General notes
- The approvals and conformities listed below must be stated when making enquiries. This is the only way to ensure that the pro duct complies with all required specifications. Not all available variants of the device can be supplied with t he below mentioned approvals or conformities. 3.2. Conformity In accordance with the Declaration of Conformity, the product is compliant with the EU Directives. 3.3. Standards The applied standards which are used to demonstrate compliance with the EU Directives are listed in the EU-Type Examination Certificate and/or the EU Declaration of Conformity. 3.4. Pressure Equipment Directive (PED) The device conforms to article 4, paragraph 1 of the Pressure Equipment Directive (PED) 2014/68/EU under the following conditions: Device used on a pipe Note: The data in the table is independent of the chemical compatibil ity of the material and the fluid. PS = maximum admissible pressure (in bar), DN = nominal diameter of the pipe Type of fluid Conditions Fluid group 1, article 4, paragraph 1.c.i DN ≤ 25 Fluid group 2, article 4, paragraph 1.c.i DN ≤ 32 or PS*DN ≤ 1000 Fluid group 1, article 4, paragraph 1.c.ii DN ≤ 25 or PS*DN ≤ 2000 Fluid group 2, article 4, paragraph 1.c.ii DN ≤ 200 or PS ≤ 10 or PS*DN ≤ 5000 3.5. North America (USA/Canada) Approval Description Optional: UL Recognized for the USA and Canada The products are UL Recognized for the USA and Canada according to: UL 61010 CAN/CSA-C22.2 No. 61010 4. Materials 4.1. Bürkert resistApp Bürkert resistApp – Chemical resistance chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start chemical resistance check
10 | 20Visit product website 4.2. Material specifications Note: Flowmeter with standard output signal or batch controller Transmitter Type SE35 Inline sensor-fitting, Type S077 Flowmeter or batch controller Type SE35 + S077 Top interior view No. Element Material
1 Screws Stainless steel
2 Front panel folio Polyester
3 Housing, cover, lid PC
4 Screws Stainless steel
5 Male fixed plug (DIN
803) PA
6 Electrical contact Sn
7 Screw Stainless steel
8 Quarter turn system PC
9 Female cable plug (DIN
803) • Body, contact holder and cable gland in PA Cable gland seal and flat seal in NBR
10 M20
x 1.5 cable gland PA
11 Sensor-fitting body Stainless steel
12 Seal FKM or FEP/PTFE encapsulated
13 Oval gear PPS, aluminium or stainless steel (316L)
14 Axis Stainless steel (316L)
11 | 20Visit product website 5. Dimensions 5.1. Transmitter Type SE35 With cable plug (DIN EN 175301‑803) Note: Dimensions in mm, unless otherwise stated Flowmeter with standard output signal (10) (180) R90 (91) (21) 133 With M20 x 1.5 cable glands Note: Dimensions in mm, unless otherwise stated Flowmeter with standard output signal or batch controller (10) (180) R90 (91) (21) 48.2 88 116 119
12 | 20Visit product website 5.2. Transmitter Type SE35 mounted in an Inline sensor-fitting Type S077 Note: Dimensions in mm, unless otherwise stated H DN H 15 126 25 135 40 147 50 157 80 207 100 223 Threaded connection Flanged connection DN 15 DN 25 DN 40 DN 50 DN 80 DN 25 DN 40 DN 50 DN 80 DN 100 6. Product installation 6.1. Installation notes Note: The device is not suitable for use in gaseous media and steam. The sensor fitting can be installed in any orientation as long as the rotor shafts are always in a horizontal plane. Correct Incorrect The following installation conditions must also be observed: The pipe always has to be filled with fluid at all times near the device. The pipe design must be such that no air bubbles or cavitation can form within the medium near the device at any time. We recommend the installation of a 250 µm strainer as close as possible to the inlet side of the meter, to prevent damage from particles, Air purges can damage the appliance and should therefore be avoided.
13 | 20Visit product website 7. Product operation 7.1. Measuring principle When liquid flows through the pipe, the rotors turn. This rotation produces a measuring signal in the associated Hall sensor. The rotation frequency of this signal is proportional to the flow velocity of the fluid. The volume of the fluid being transferred in this way is exactly determined through the sensor geometry. A conversion coefficient, specific to each meter size, enables the conversion of this frequency into a flow rate. The standard K factor depending on the meter size is available in the flowmeter’s operating instructions, see Type S077 . To improve the measurement deviation, a device-specific K factor is given on the device label. Flowmeter: The electronic component converts the measured signal into several outputs (according to the device variant) and displays the actual value. Totalizers are used to obtain the volume of fluid passed through the pipe. The electrical connection for the flowmeter with standard output signal is provided via a cable plug according to DIN EN 175301 803 or two cable glands (according to the flowmeter variant). Batch controller: The electronic component converts the measured signal and displays the actual value of the volume or mass. The electrical connection is provided via two cable glands.
14 | 20Visit product website 7.2. Functional overview Display and operating keys The display is used to: read the value of certain parameters e.g. for the flowmeter, the measured flow rate, the main totalizer set parameters of the device by means of 3 keys read the configuration of the device be warned of certain events. Display and operating keys No. Description 1 “Back” key: to change the value (0…9) of the selected digit to go back to the previous function Read the batches history (only for batch controller) 2 “Next” key: to select the digit at the left to go to the next function read messages (only with Inline flowmeter as battery powered indicator/totalizer and with batch controller) 3 “Confirm” key: to confirm the function displayed to confirm the parameters set 4 • For Inline flowmeter with a standard output signal status LED of relay 2 For batch controller status LED of relay DO3 (LED ON = contact closed) 5 • For Inline flowmeter with a standard output signal status LED of relay 1 For batch controller status LED of relay DO2 (LED ON = contact closed)
6 Status of device
No status for Inline flowmeter with a standard output signal For Inline flowmeter as a battery powered indicator/totalizer off: the device operates correctly. blinking orange: a warning message is generated in the information menu. blinking red: a fault message is generated For batch controller green: the device operates correctly. orange: a dosing related alarm and/or a warning messages is generated in the information menu. red: a fault message is generated in the information menu.. blinking, whatever the colour: slow blinking: the dosing is interrupted. Fast blinking during a dosing: a dosing related alarm is generated. Fast blinking when no dosing is being done: the information menu has been remote-con- sulted or a check for the correct behaviour of the inputs/outputs is running The device can be calibrated by means of the K factor of the fitting or via the teach function. User adjustments, such as engineering units, output, filter or bargraph are carried out on site.
15 | 20Visit product website Flowmeter with a standard output signal The device has 2 operating levels: the process level the configuration level, which comprises the parameters and the test menus Operating level Functions Process • Indication of the value of the measured flow the value of the 4…20 mA output the value of the main totalizer the value of the daily totalizer Reset the daily totalizer Access to the Parameters and Test menus of the Configuration level Configuration - parameters menu To make the settings needed for operation: language engineering units (International measuring units) K-factor/Teach-In function 4…20-mA-current output pulse output relay (on devices with relays) filter (damping) reset both totalizers Configuration - test menu To adjust the Offset and Span of the 4…20 mA current output To read the rotational frequency of the paddle wheel To check the correct operating of the outputs with simulating a flow rate
16 | 20Visit product website Batch controller The device has 2 operating levels: The process level The configuration level, which includes the parameters, the test, the information and the history menus Operating level Functions Process • Starting a dosing Indication of The value of the main totalizers of the quantity of fluid counted The value of the daily totalizers of the quantity of fluid counted The value of the main totalizers of the performed dosings The value of the daily totalizers of the performed dosings Reset The daily volume or mass totalizer The daily totalizer of the performed dosings Access to the parameters, test, information and history menus of the configuration level Configuration - parameters menu To make the settings needed for operation: language engineering units (International measuring units) K-factor/Teach-In function Optional/dosing mode Overfill Alarm Outputs Resetting the 2 volume or mass totalizers Resetting the 2 totalizers of the performed dosings Resetting the history menu Backlight Configuration - test menu Checking: The inputs functions The outputs functions The paddle-wheel operation Monitoring: The flow rate in the pipe The value of the daily volume or mass totalizer The number of performed dosings Saving/ Restoring: The current user configuration The saved configuration The default configuration of the device Configuration - history menu To consult the quantities dosed in the last 10 dosings performed Configuration - informa tion menu To read the fault and warning messages generated
17 | 20Visit product website 7.3. Function modes Flowmeter with standard output signal 4…20 mA output + Pulse 4…20 mA output + Pulse + relay output Hysteresis switching mode (both relays) for the output, inverted or not OLO OHI OLO OHI Contact inverted not inverted Contact Hysteresis mode Batch controller The following dosing modes are possible: Locally started dosing of free quantity: the user enters the quantity to be filled and starts the dosing from the keypad. pre set quantity: the user selects a quantity which has been pre-set and starts the dosing from the keypad. Dosing controlled by a PLC unit: the user selects a quantity which has been pre-set and starts the dosing using binary inputs. Locally/remote selection of pre set quantity and dosing controlled by a PLC unit: the user selects a quantity which has been pre-set from the keypad or using binary inputs and starts the dosing using binary inputs. Automatic dosing controlled by variation of pulse duration: the volume to be dosed is directly proportional to the duration of a pulse. Locally/remote dosing determined by teach-in: teach-in of the dosing quantity from the keypads teach-in of the dosing quantity using binary inputs. 8. Product design and assembly 8.1. Product assembly Note: The device Type SE35 S077 is made up of a Bürkert Inline sensor-fitting Type S077 equipped with a sensor with oval gears and a transmitter Type SE35. The Inline sensor-fitting Type S077 ensures simple installation into pipes from DN 15…DN 100. The transmitter Type SE35 can be mounted on any Inline sensor-fitting Type S077 and fastened with a bayonet catch, see data sheet Type S077 for more information. Inline sensor-fitting Type S077 Transmitter Type SE35 Inline measurement device Type SE35 + S077 for flow measurement or batch control
18 | 20Visit product website 9. Networking and combination with other Bürkert products 9.1. Flowmeter with a standard output signal Example: Type SE35 + S077 4…20 mA output Transistor output Relay output Type 8802 (2301 & 8693) ELEMENT Continuous control valve systems Type 6212 Servo-assisted 2/2-way diaphragm valve Type 6281 Servo-assisted 2/2-way diaphragm valve 9.2. Batch controller Example: Type SE35 + S077 Type 6212 Servo-assisted 2/2-way diaphragm valve Type 6281 Servo-assisted 2/2-way diaphragm valve 10. Ordering information 10.1. Bürkert eShop Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now
19 | 20Visit product website 10.2. Recommendation regarding product selection A complete flowmeter Type SE35 + S077 consists of a flow transmitter Type SE35 and an Inline sensor-fitting Type S077. See data sheet Type S077 for more information. Two different components must be ordered in order to select a complete device. The following information is required: Article no. of the compact Type SE35 flow transmitter or batch controller (see chapter “10.4. Ordering chart” on page 19 Article no. of the selected Type S077 Inline sensor-fitting (see data sheet Type S077 10.3. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter 10.4. Ordering chart Flowmeter Note: The following variants have at least 2 volume totalizers. Operating voltage Sensor variant Output UL approval Electrical connection Article no. Flow transmitter Type SE35 with standard output signal 12…36 V DC Hall 4…20 mA (2 wires) + Pulse — Female cable plug DIN EN 175301 803 444005 UL Recognized 570477 — 2 cable glands 444006 UL Recognized 2 cable glands 553432 Hall 4…20 mA (3 wires) + Pulse + 2 relays — 2 cable glands 444007 UL Recognized 2 cable glands 553433 V AC Hall 4…20 mA (2 wires) + Pulse — 2 cable glands 423922 Hall 4…20 mA (3 wires) + Pulse + 2 relays — 2 cable glands 423924 Batch controller Note: The following variants have at least 2 volume or mass totalizers and 2 totalizers of the number of dosing performed. Operating voltage Sensor variant Input Output UL approval Electrical connection Article no. 12…36 V DC Hall 4 digital inputs (DI1…DI4) 2 transistor outputs (DO1 and DO4) + 2 relay outputs (DO2 and DO3) – 2 cable glands 443360 UL Recognized 564398 V AC – 423926
20 | 20Visit product website 10.5. Ordering chart accessories Description Article no. For flowmeter or batch controller Set with two cable glands M20 1.5, two neoprene flat seals for cable gland or plug, two screw plugs M20 1.5 and two multi-way seals 2 mm 449755 Set with two adaptors M20 1.5 /NPT ½", two neoprene flat seals for cable gland or plug and two screw plugs M20 1.5 551782 Set with a stopper for unused cable gland M20 1.5, a multi-way seal 2 mm for cable gland, a black EPDM seal for the sensor and a mounting instruction sheet 551775 For flowmeter Female cable plug, 4-pin (3 conductors + protective conductor), form A according to DIN EN 175301 803 with cable gland (Type 2518 572264 Female cable plug 32 mm, 4-pin (3 conductors + protective conductor), form A according to DIN EN 175301 803, with NPT ½" reduction without cable gland (Type 2509 162673 For batch controller Set with 8 FLOW front panel films 553191