Features

– 64 digital inputs according to EN 61131-2 type 1 and type 3 –2 4 V DC, 2.4 mA – Connection of sensors in 1-wire technology – Minimum update time < 100 μs – Filter times can be set in three increments: < 100 µs, 1000 µs or 3000 µs – Maximum input frequency: 5 kHz – Device type label stored – Diagnostic and status indicators This data sheet is only valid in association with the UM EN AXL F SYS INST user manual. Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. 8566_en_01 2015-05-19

8566_en_01 PHOENIX CONTACT 2 2T a b l e o f c o n t e n t s

8566_en_01 PHOENIX CONTACT 3 Description Type Order No. Pcs./Pkt. Axioline F digital input module, 64 inputs, 24 V DC, 1-wire connection tech- nology (including bus base module and connectors) AXL F DI64/1 2F 2701450 1 3O r d e r i n g d a t a Accessories Type Order No. Pcs./Pkt. Axioline F bus base module for housing type F (Replacement item) AXL F BS F 2688129 5 Axioline F connector set (for e.g., AXL F DI64/1 2F) (Replacement item) AXL CNS 8L-O/D/UI 2701728 1 Zack marker strip for Axioline F (device labeling), in 2 x 20.3 mm pitch, un- printed, 25-section, for individual labeling with B-STIFT 0.8, X-PEN, or CMS-P1-PLOTTER (Marking) ZB 20,3 AXL UNPRINTED 0829579 25 Zack marker strip, flat, in 10 mm pitch, unprinted, 10-section, for individual labeling with M-PEN 0,8, X-PEN, or CMS-P1-PLOTTER (Marking) ZBF 10/5,8 AXL UNPRINTED 0829580 50 Documentation Type Order No. Pcs./Pkt. User manual, English, Axioline F: System and installation UM EN AXL F SYS INST - - User manual, English, Axioline F: Diagnostic registers, and error messages UM EN AXL F SYS DIAG - - Dimensions (nominal sizes in mm) Width 53.6 mm Height 129.9 mm Depth 54 mm Note on dimensions The depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715).

4 Technical data

53,6 54 122,4 129,9 General data Color traffic grey A RAL 7042 Weight 231 g (with connectors and bus base module) Ambient temperature (operation) -25 °C ... 60 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)

8566_en_01 PHOENIX CONTACT 4 Degree of protection IP20 Protection class III, IEC 61140, EN 61140, VDE 0140-1 Mounting position Any (no temperature derating) General data Connection data Designation Axioline F connector Connection method Push-in connection Conductor cross section [AWG] 24 ... 16 Stripping length 8 mm Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. Interface Axioline F local bus Connection method Bus base module Transmission speed 100 MBit/s Communications power Communications power UBus 5 V DC (via bus base module) Current consumption from UBus max. 120 mA Power consumption at UBus max. 600 mW I/O supply Supply of digital input modules UI 24 V DC Maximum permissible voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Current consumption from UI max. 60 mA Power consumption at UI typ. 1.1 W, max. 1.8 W Surge protection of the supply voltage Electronic (35 V, 0.5 s) Polarity reversal protection of the supply voltage Parallel diode; with external 5 A fuse (for startup only) Protection max. 8 A (polarity re versal protection up to 5 A) When using for the first time, protect the module with a 5 A fuse. If all the modules are correctly connected in the system, the 5 A fuse can be replaced by an 8 A fuse. you can now load the module up to 8 A. NOTE: Damage to the electronics Provide the module with an external fuse to protect it against polarity reversal. The power supply unit must be able to supply four times the nominal current of the external fuse, to ensure that it trips in the event of an error. Digital inputs Number of inputs 64 Connection method Push-in connection Connection method 1-wire Description of the input EN 61131-2 types 1 and 3 Nominal input voltage 24 V DC Nominal input current 2.4 mA Current flow Linear until nominal current is reached, then constantly approx. 2.4 mA Input voltage range "0" signal -3 V DC ... 5 V DC Input voltage range "1" signal 11 V DC ... 30 V DC Input filter time 3000 µs (default), 1000 µs, < 100 µs Process data update < 100 µs Polarity reversal protection of the inputs Parallel diode (30 V, 5 s)

8566_en_01 PHOENIX CONTACT 5 Configuration and parameter data in a PROFIBUS system Required parameter data 3 Byte Need for configuration data 6 Byte Error messages to the higher level control or computer system I/O supply failure Yes Electrical isolation/isolation of the voltage areas Test section Test voltage

5 V communications power (logic), 24 V supply (I/O) 500 V AC, 50 Hz, 1 min

5 V supply (logic)/functional earth ground 500 V AC, 50 Hz, 1 min

24 V supply (I/O) / functional earth ground 500 V AC, 50 Hz, 1 min

Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g Conformance with EMC Directive 2004/108/EC Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B; 6 kV contact discharge, 8 kV air discharge Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A; Field intensity: 10 V/m Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV Transient surge voltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B; DC supply lines: ±0 .5 kV/±0.5 kV (symmetrical/asymmetrical) Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class B Approvals For the latest approvals, please visit phoenixcontact.net/products.

8566_en_01 PHOENIX CONTACT 6

5 Internal circuit diagram

Figure 1 Internal wiring of the terminal points Key: Local bus Axioline F local bus (hereinafter referred to as local bus) Microcontroller Optocoupler LED Power supply unit Electrically isolated areas Input circuit Input circuit IN 1...32 IN 33...64 U 24 V I UBus Local bus /UNIf16dC D UI Input circuit Input circuit µC

8566_en_01 PHOENIX CONTACT 7

6 Terminal point assignment

Figure 2 Terminal point assignment

7 Connection example

Figure 3 Example of a connection of sensors when using external busbars Ensure that GND of the sensors and GND for UI have the same potential.Terminal point Color Assignment Supply voltage input a1, a2 Red 24 V DC (UI) Digital input module sup- ply (internally jumpered) b1, b2 Blue GND Referen ce potential of the supply voltage (inter- nally jumpered) Digital inputs IN24 Digital inputs 17 ... 24 IN32 Digital inputs 25 ... 32 IN40 Digital inputs 33 ... 40 IN48 Digital inputs 41 ... 48 IN56 Digital inputs 49 ... 56 IN64 Digital inputs 57 ... 64 4740 0700 1710 2720 3730 5750 6760 7770 +24 V IN25 +24 V IN1 +24 V IN8 +24 V IN32 +24 V

8566_en_01 PHOENIX CONTACT 8

8 Local status and diagnostic indicators

Figure 4 Local status and diagnostic indicators D UI 00 02 04 06 10 12 14 1611 13 15 17 20 22 24 2621 23 25 27 41 43 45 47 51 53 55 57 61 63 65 67 71 73 75 77 40 42 44 46 50 52 54 56 60 62 64 66 70 72 74 76 32 34 3631 33 35 37 01 03 05 07 Designation Color Meaning State Description DR e d / yellow/ green Diagnostics of local bus communication Run Green ON The device is ready for oper ation, communication within the station is OK. All data is valid. There are no faults. Active Green flashing The device is ready for operation, communication within the station is OK. The data is not valid. Valid data from the controller/higher-level net- work not available. There is no fault in the module. Device ap- plication not active Flashing green/yel- low The device is ready for operation, communication within the station is OK. Output data cannot be outputted and/or input data cannot be read. There is a fault on the periphery side of the module.. Ready Yellow ON The device is ready for operat ion but did not detect a valid cycle after power-on. Connected Yellow flashing The device is not (yet) part of the active configuration. Reset Red ON The device is ready for operat ion but has lost the connection to the bus head. Not con- nected Red flash- ing The device is ready for operation but there is no connection to the previously existing device. Power down OFF Device in (power) reset. UI Green U Input ON Supply of digital input modules present. OFF Supply of digital input modules not present. Yellow Status of the inputs ON Input is set. OFF Input is not set.

8566_en_01 PHOENIX CONTACT 9 9P r o c e s s d a t a The I/O data is displayed in S7-compatible format. IN process data Byte 0 B i t 76543210 C h a n n e l 87654321 Terminal point 07 06 05 04 03 02 01 00 Byte 1 B i t 76543210 C h a n n e l1 61 51 41 31 21 11 0 9 Terminal point 17 16 15 14 13 12 11 10 Byte 2 B i t 76543210 C h a n n e l2 42 32 22 12 01 91 81 7 Terminal point 27 26 25 24 23 22 21 20 Byte 3 B i t 76543210 C h a n n e l3 23 13 02 92 82 72 62 5 Terminal point 37 36 35 34 33 32 31 30 Byte 4 B i t 76543210 C h a n n e l4 03 93 83 73 63 53 43 3 Terminal point 47 46 45 44 43 42 41 40 Byte 5 B i t 76543210 C h a n n e l4 84 74 64 54 44 34 24 1 Terminal point 57 56 55 54 53 52 51 50 Byte 6 B i t 76543210 C h a n n e l5 65 55 45 35 25 15 04 9 Terminal point 67 66 65 64 63 62 61 60 Byte 7 B i t 76543210 C h a n n e l6 46 36 26 16 05 95 85 7 Terminal point 77 76 75 74 73 72 71 70

8566_en_01 PHOENIX CONTACT 10

10 Parameter, diagnostics and infor-

mation (PDI) Parameter and diagnostic data as well as other information is transmitted via the PDI channel of the Axioline F station. The standard and application objects stored in the module are described in the following section. The following applies to all tables below: Please refer to the UM EN AXL F SYS INST for an explana- tion of the object codes and data types. Abbreviation Meaning A Number of elements L Length of the elements RR e a d WW r i t e Every visible string is terminated with a zero terminator (00 hex). The length of a visible string element is therefore one byte larger than the amount of user data. For detailed information on PDI and the ob- jects, please refer to the UM EN AXL F SYS INST user manual.

8566_en_01 PHOENIX CONTACT 11

11 Standard objects

11.1 Objects for identificati on (device rating plate)

(hex) Object name Object type Data type A L Rights Meaning Contents Manufacturer

0001 VendorName Var Visible String 1 16 R Vendor name Phoenix Contact

0002 VendorID Var Visible String 1 7 R Vendor ID 00A045

0003 VendorText Var Visible String 1 4 9R V e n d o r t e x t C o m p o n e n t s a n d

0012 VendorURL Var Visible String 1 23 R Vendor URL www.phoenixcon- tact.com Module - general

0004 DeviceFamily Var Visible String 1 15 R Device family I/O digital IN

0006 ProductFamily Var Visible String 1 6 R Product family AXL F

000E CommProfile Var Visible String 1 4 R Communication pro- file 633 000F DeviceProfile Var Visible String 1 5 R Device profile 0010

0011 ProfileVersion Record Visible String 2 11; 20 R Profile version 2011-12-07;

Basic Profile V2.0 003A VersionCount Array Unsigned 16 4 4 * 2 R Version counter e.g., 0007 0001 0000 0000 hex Module - special

0005 Capabilities Array Visible String 1 8 R Features Nothing

0007 ProductName Var Visible String 1 16 R Product name AXL F DI64/1 2F

0008 SerialNo Var Visible String 1 11 R Serial number xxxxxxxxxx (e. g., 1234512345)

0009 ProductText Var Visible String 1 37 R Product text 64 digital inputs, ad-

000A OrderNumber Var Visible String 1 8 R Order No. 2701450 000B HardwareVersion Record Visible String 2 11; 3 R Hardware version e. g., 2011-02-04; 00 000C FirmwareVersion Record Visible String 2 11; 3 R Firmware version 0000-00-00; -- 000D PChVersion Record Visible String 2 11; 6 R Parameter channel version 2010-01-08; V1.00

0037 DeviceType Var Octet string 1 8 R Module identification 00 80 00 08 00 00 00

0014 Location Var Visible String 1 59 R /W Location Can be filled out by

the user.

0015 EquipmentIdent Var Visible String 1 59 R/W Eq uipment identifier Can be filled out by

the user.

0016 ApplDeviceAddr Var Unsigned 16 1 2 R/W Application device

the user.

8566_en_01 PHOENIX CONTACT 12

11.2 Object for multilingual capacity

11.3 Diagnostics objects

Diagnostics state (0018hex: DiagState) This object is used for a structured message of an error. Error and status of the local status and diagnostics indicators Index (hex) Object name Object type Data type A L Rights Meaning Contents

0017 Language Record Visible String 2 6; 8 R Language en-us; English

(hex) Object name Object type Data type A L Rights Assignment/content

0018 DiagState Record 6 2; 1; 1;

2; 1; 1 R Diagnostic state 0018hex: DiagState (Read) Subindex Data type Length in bytes Meaning Contents

0 Record 8 Diagnostic state Complete diagnostics information

1 Unsigned 16 2 Error number 0 ... 65535 dez

2 Unsigned 8 1 Priority 00 hex No error

3 Unsigned 8 1 Channel/group/module 00 hex No error

4 Unsigned 16 2 Error code See table below

5 Unsigned 8 1 More follows 00 hex

6 Visible String 1 Text 00 hex

The message with the priority 81hex or 82hex is a one-time internal message to the bus cou- pler that is implemented onto the error mech- anisms of the higher-level system by the bus coupler. After all errors have been eliminated, it is au- tomatically reset. Subindex 2 3 4 Error Priority Channel/group/ module Error code LED hex hex hex dec D UI No error 00 00 0000 0 Green ON ON I/O supply failure 01 FF 3412 13330 Flashing green/ yellow OFF

8566_en_01 13PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany phoenixcontact.com

11.4 Objects for process data management

The objects 003Bhex and 003Chex are only applicable to tools. IN process data (0025hex: PDIN) You can read the IN process data of the module with this object. The structure corresponds to the representation in the "Process data" section. In the case of valid parameters, the parameterization is stored in the module permanently. Filter time (FF8Fhex: Input_Filter) You parameterize the filter time of the module with this object.

13 Device descriptions

The device is described in the device description files. The device descriptions for controllers from Phoenix Con- tact are included in PC Worx and the corresponding service packs. The device description files for other systems are available for download at phoenixcontact.net/products in the down- load area of the bus coupler used. Index (hex) Object name Object type Data type A L Rights Assignment

0025 PDIN Var Octet string 1 8 R Input process data

003B PDIN_Descr Array of Re- cords 3 8; 2; 2 R Description of the IN process data 003C PDOUT_Descr Array of Re- cords 3 8; 2; 2 R Description of the output process data 0025hex: PDIN (Read) Subindex Data type Length in bytes Meaning

0 Octet string 8 Input process data

(hex) Object name Object type Data type A L Rights Assignment FF8F Input_Filter Var Unsigned 8 1 1 R/W Filter time FF8Fhex: Input_Filter (read, write) Subindex Data type Length in bytes Contents 0V a r 10 0 hex (Default) 3000 µs 01hex 1000 µs 02hex < 100 µs