Visit product website DATA SHEET Standard | EU | en | 202305 | 01 RTD temperature sensor with IO-Link inter- face
- Single resistance thermometer Type Pt1000 Process connections: G ½", clamp DN 10/20 according to DIN 32676 Temperature measurement range: - 50…+ 150 Available switching functions: PNP or NPN Access to measured value, device status and settings via IO-Link interface, very easy sensor replacement The temperature sensor is used for measuring and monitoring the tempera- ture. The impact of the temperature on a resistance thermometer generates a signal which is amplified, digitised and processed. Instead of an analogue output, this device offers a digital interface IO-Link. This allows bidirectional data transfer with any IO-Link master. Data access occurs via the available standardised IODD. The IO-Link corresponds to the specification version 1.1. The bidirectional communication is used to read process data, parameters, diagnostic infor- mation and status messages as well as to set parameters. The two green LEDs are permanently lit as soon as power is supplied to the device. Once an IO-Link connection has been established, the LEDs flash. The switching behaviour and the switching thresholds of the digital outputs (max. 2; “PNP” or “NPN”) can - like many other parameters - be individually configured. Product variants described in the data sheet may differ from the product presentation and description. Type description Type 8418 © Christian Bürkert GmbH & Co. KG, Subject to alteration
2 | 8Visit product website Table of contents 1. General technical data 3 Approvals Device used on a pipe Device used on a vessel 3. Materials 5 4. Dimensions 6
Ordering information
5.2. Bürkert product filter 5.3. Ordering chart
3 | 8Visit product website 1. General technical data Product properties Material Make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page 5 Non wetted parts Housing • Stainless steel 1.4404 (316L) for thread connection variant Stainless steel 1.4571 (316Ti) for clamp connection variant Circular connector • Stainless steel 1.4404 (316L), PBT GF 6.5 for thread connection variant Stainless steel 1.4571 (316Ti), PBT GF 6.5 for clamp connection variant Wetted parts Process connection • Stainless steel 1.4404 (316L) for thread connection variant Stainless steel 1.4435 (316L) for clamp connection variant (with low delta ferrite content) Protection tube • Stainless steel 1.4404 (316L) for thread connection variant Stainless steel 1.4435 (316L) for clamp connection variant Dimensions Detailed information can be found in chapter “4. Dimensions” on page 6 Weight Approx. 80 g for the variant with thread connection and 100 mm probe length. The weight of the temperature sensor depends on the process connection and the insertion length. Measuring element RTD temperature probe Pt1000, four-wire circuit Measuring probe length 50 or 100 mm Measuring range - 50…+ 150 °C (- 58…+ 302 °F) Monitoring Measuring circuit: IO-Link event configurable and is available as device status Process data invalid Measuring range overflow Measuring range underflow Device hardware fault Additional function • Fine adjustment Change between °C/°F Data format switchover (integer/floating point) Switching outputs in SIO mode Performance data Sampling rate 160 ms Transmission behaviour Temperature linear Measuring resolution 14 bit Measurement deviation • Tolerance class A, ± (0.15 0.002 |t|1.)) °C according to EN 60751:2009/IEC 60751:2008 ≤ ±(0.08 %)2.) (calibration of the electronic components) Response time Protection tube Ø 6 mm (standard): t0.5 = 5 s; t0.9 = 12 s, in water with a flow velocity of 0.4 m/s t0.5 = 40 s; t0.9 = 110 s, in air with a flow velocity of 3.0 m/s Electrical data Operating voltage • In IO-Link operation: 18…32 V DC, filtered and regulated In switch operation: 9.6…32 V DC, filtered and regulated Nominal voltage: 24 V DC Power source (not supplied) The auxiliary energy of the pressure sensor must meet SELV requirements; optionally, an ener - gy-limited current circuit according to paragraph 9.3 of DIN EN 61010 1 and UL 61010 1 can be used DC reverse polarity protection Yes Short circuit protection Yes (clocked) Protection class Class III according to EN 61140 Current consumption • In idle operation: ≤ 12 mA (at nominal voltage) In IO-Link operation: ≤ 20 mA (at nominal voltage) In switch operation: ≤ 200 mA (at nominal voltage and with 2 digital outputs) Galvanic isolation To the protection tube; no galvanic isolation between sensor and output
4 | 8Visit product website Signal processing Input filter: digital filter, second order filter time constant can be set Output Number of outputs • 1 digital output in IO-Link operation 2 digital outputs for switch operation (SIO mode; SIO = standard IO) Switching function configurable • Hysteresis function (Hysteresis configurable) or window function (fixed setting, symetrical, 0.25 % of the measuring range) NC or NO contact Digital output PNP or NPN Switch-on/switch-off delay (0…100 s) Measuring current ≤ 500 µA Switching current ≤ 100 mA per output Current limiting Yes Voltage drop at switching transistor
2 V DC
4-wire unshielded cable, max. 20 m Medium data Fluid Liquid and gaseous medium Fluid pressure • G ½" process connection: Max. 40 bar Clamp DN 10/20, according to DIN 3676. The permissible pressures are designed for an oper- ating temperature range of - 10 to + 140 °C given use of suitable clamps and sealing materials. Process/Port connection & communication Process connection • G ½" according to EN 837 Clamp DN 10/20 according to DIN 32676 Detailed information on the process connection can be found in chapter “5.3. Ordering chart” on page 7 Electrical connection M12 1 circular male connector, 4 pins, A-coded, non rotating (IO-Link Port Class A) Digital communication: IO-Link Communication interface IO-Link device V1.1, downward compatible to V1.0 Baud rate (data transfer rate) COM 3 (230.4 kBaud) Cycle time Min. 2 ms IO device description (IODD) Depending on the ordered input range See “Device Description Files” on the website in the Software chapter Type 8418 available or at https://ioddfinder.io-link.com Approvals and certificates Directives CE directive The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable). Pressure equipment directive • The device does not meet the requirements for “safety accessories” within the meaning of the Pressure Equipment Directive 2014/68/EU. Complying with article 4, paragraph 1 of 2014/68/EU directive Detailed information on the pressure equipment directive can be found in chapter “2.1. Pres- sure equipment directive” on page 5 Environment and installation Ambient temperature Operation3.) and storage: - 40…+ 85 °C (- 40…+ 185 °F) Temperature influence ≤ 0.0025 % per K2.)4.) Relative air humidity • During operation: ≤ 100 %, without condensation on the outer housing surface of the device During storage: ≤ %, without condensation Climate class 3K7 according to EN 60721 Application range A Degree of protection according to IEC/EN 60529 IP66/IP67/IP69 with connector screwed on Mounting position Unrestricted 1.) |t| = temperature value in °C regardless of the prefix sign. 2.) All accuracy specifications in % relative to the respective measuring range 3.) At process temperatures above 120 °C, the maximum admissible ambient temperature is 60 °C (stated at nominal voltage 24 V DC)
5 | 8Visit product website 4.) Relative to the temperature deviation at the calibration point (25 °C ± 5 K) 2. Approvals 2.1. Pressure equipment directive The device conforms to article 4, paragraph 1 of the pressure equipment directive 2014/68/EU under the following conditions: Device used on a pipe Note: The data in the table is independent of the chemical compatibility of the material and the fluid. PS = maximum admissible pressure (in bar), DN = nominal diameter of the pipe Type of fluid Conditions Fluid group 1, article 4, paragraph 1.c.i DN ≤ 25 Fluid group 2, article 4, paragraph 1.c.i DN ≤ 32 or PS*DN ≤ 1000 Fluid group 1, article 4, paragraph 1.c.ii DN ≤ 25 or PS*DN ≤ 2000 Fluid group 2, article 4, paragraph 1.c.ii DN ≤ 200 or PS ≤ 10 or PS*DN ≤ 5000 Device used on a vessel Note: The data in the table is independent of the chemical compatibility of the material and the fluid. PS = maximum admissible pressure (in bar), V = vessel volume Type of fluid Conditions Fluid group 1, article 4, paragraph 1.a.i V > 1 L and PS*V ≤ 25 bar.L or PS ≤ 200 bar Fluid group 2, article 4, paragraph 1.a.i V > 1 L and PS*V ≤ 50 bar.L or PS ≤ 1000 bar Fluid group 1, article 4, paragraph 1.a.ii V > 1 L and PS*V ≤ 200 bar.L or PS ≤ 500 bar Fluid group 2, article 4, paragraph 1.a.ii PS > 10 bar and PS*V ≤ 10000 bar.L or PS 1000 bar 3. Materials 3.1. Chemical Resistance Chart – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check
6 | 8Visit product website 4. Dimensions Note: Dimensions in mm, unless otherwise stated Ø 18 M12 × 1 LED ≈ 641.) Ø 8 G ½" 50 or 100 M12 × 1 LED Ø 19 ≈ 811.)50 or 100 With clamp DN10/20 process connection according to DIN 32676 With G ½" process connection according to EN 837 1.) The total height is increased by the height of the used female connector and cable. Ø 34 5. Ordering information 5.1. Bürkert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now
7 | 8Visit product website 5.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter 5.3. Ordering chart Note: The following variants have an operating voltage depending on operation mode (IO-Link: 18…32 V DC, Switch: 9.6…32 V DC or Nominal: 24 V DC) an IO-Link digital interface (according to specification version 1.1) or digital outputs (SIO mode; SIO = standard IO) Process connection Temperature range Probe length Article no. [°C] [mm] G ½" according to EN 837 - 50…+ 150 50 574634 100 574635 Clamp DN 10/20 according to DIN 32676 50 574636 100 574637 Further versions on request Process connection Screw-in thread G ⅜" Screw-in thread M12 x 1.5 and G ½" with CIP-compli ant conical seal Aseptic screw-in thread DN 20, DN 25, DN 32, DN 40, DN 50 according to DIN 11864 1 form A Taper socket with union nut DN 10, DN 25, DN 32 according to DIN 11851 (dairy pipe fitting) Clamping socket (clamp) DN 10/20, DN 25/40 accord ing to DIN 32676 Clamping socket (clamp) DN 50 according to DIN 32676 (2" ISO 2852) Clamping socket (clamp) 2 ½" similar to DIN 32676 Ball welding socket with threaded compression fitting Welding socket with CIP-compliant conical seal VARIVENT® connection DN 15/10, DN 32/25 or DN 50/40 BioControl® D25, D50, D65 or D80 Temperature 50…+ 260 °C (- 58…+ 500 °F) Electrical connection IO-Link, M12 x 1 connector, high-temperature Additional Pt1000 temperature sensor, four-wire circuit Class AA according to EN 60751:2009 / IEC 60751:2008 With protection tube diameter 3 mm only with screw- in thread M12 x 1.5 with CIP-compliant conical seal Insertion length: 15, 20, 25 only with screw-in thread M12 x 1.5 with CIP-compliant conical seal or 150 mm Certification Inspection certificate 3.1 DIN EN 10204 (material) Special calibration
Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -
74653 Künzelsau