Visit product website DATA SHEET Type ME43 Fieldbus gateway PLC With CANopen interface Integration into CANopen and büS networks Standard | EU | en | 202209 | 03 RTD temperature sensor with CANopen interface
- Single r esistance thermometer Type Pt1000 P rocess connections: G ½", NPT ½" or clamp ¾" T emperature measurement range: - 50…+ 150 Limit value monit oring function Access t o measured value, device status and settings via the CAN- open interface Resistance thermometers are the preferred choice for measuring the temper- ature of liquids and gases. The design offers reliable tightness under negative and positive pressure. The measuring insert is equipped with a Pt1000 temperature sensor accord- ing to DIN EN 60751, Class A. The measured temperature value is digitised, linearised and made available via the CANopen digital communication inter- face (CAN slave) for further processing. Instead of an analogue output, this device offers the C ANopen digital inter- face. This allows bidirectional data transfer, e.g. with a CAN/Ethernet gateway or directly to a PLC that is equipped with a CAN interface. CAN devices can also be connected to the Bürkert büS digital communication interface. A driver used for data exchange and settings of the 8412 is integrated in the Bürkert PC tool Communicator. Several useful auxiliary functions have been implemented through the DS 404 device profile. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 8412 © Christian Bürkert GmbH & Co. KG, Subject to alteration
2 | 11 Visit product website Table of contents 1. Gener al technical data 3 Approvals Device used on a pipe Device used on a vessel 3. Materials 5 4. Dimensions 6 P roduct operation 6. P roduct accessories 8 Or dering information 7.2. Bürk ert product filter 7.3. Or dering chart 7.4. Or dering chart accessories
3 | 11 Visit product website 1. Gener al technical data Product properties Material Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page 5. Non wetted parts Housing Stainless steel 1.4571 (316Ti) Wetted parts Process connection • G or NPT variant: stainless st eel 1.4571 (316Ti) Clamp variant: stainless st eel 1.4435 (316L) Protection tube • G or NPT variant: stainless st eel 1.4571 (316Ti) Clamp variant: stainless st eel 1.4435 (316L) Dimensions Detailed information can be found in chapter “4. Dimensions” on page 6. Weight Approx. 80 g for the variant with thread connection and 100 mm probe length. The weight of the temperature sensor depends on the process connection and the inser- tion length. Measuring element Pt1000 temperature sensor, two-wire circuit Measuring probe length 25, 30, 50, 100 or 150 mm Measuring range - 50…+ 150 58…+ 302 °F) Monit oring • Measuring cir cuit – Underr ange (freely selectable lower limit) – Overr ange (freely selectable upper limit) P robe short circuit P robe break Additional function • Min./max. measur ed value memory Fine adjustment T oggling between °C, °F, °K Decimal places selectable 0, 1, 2 P erformance data Sampling rate 250 ms Transmission behaviour Temperature linear Measuring resolution 12 Bit Measurement deviation • T olerance class A according to EN 60751:2009 / IEC 60751:2008 Max. ± 0.2 % of the measuring r ange span Response time • t0.5 = 5 s; t0.9 = 12 s, in wat er with a flow velocity of 0.4 m/s t0.5 = 40 s; t0.9 = 110 s, in air with a flow velocity of 3.0 m/s Electrical data Oper ating voltage 10…30 V DC, filtered and regulated Power source (not supplied) The auxiliary energy of the pressure sensor must meet SELV requirements; optionally, an energy-limited current circuit according to section 9.3 of DIN EN 31010 1 and UL 61010 can be used. DC reverse polarity protection Yes Overvoltage protection Yes Short circuit protection Yes Protection class Class III according to EN 61140 Current consumption Approx. max. 45 mA Recommended connection cable 5-wire shielded cable, length depends on the transmission speed. The physical CAN transmission is standardized according to ISO 11898 2 (high-speed) and ISO 11898 (low-speed) Medium data Fluid Liquid and gaseous medium Fluid pressure Max. 40 bar Process/Pipe connection & communication Process connection • G ½" or NPT ½" scr ew-in thread according to EN 837 Clamp ¾" accor ding to DIN 32676 series B Electrical connection M12 1 male connect or, 5 pin according to DIN IEC 60947
4 | 11 Visit product website Digital communication: CANopen Protocol CiA DS 301, V4.02, CANopen slave Profile CiA DS 404, V1.2; measuring devices and closed-loop controllers Baud rate 20 kbaud to 1 Mbaud, setting via LSS or SDO Node ID 1 to 127 setting via LSS or SDO PDO 0 Rx, 1 Tx SDO 1 Rx, 1 Tx Emergency Yes Heartbeat Yes (if active, then Node Guarding deactivated) Node Guarding Yes (if active, then Heartbeat deactivated) LSS Yes SYNC Yes Operation and project planning All parameters are accessible via the CANopen object directory (EDS) and can be set via standard CANopen software tools or Bürkert Communicator. EDS (electronic data sheet) • Device driver in Bürk ert Communicator tool Type 8920, see “Bürkert Communicator” on the website in the Software chapter Type 8920 See “Device Description Files” on the websit e in the Software chapter Type 8412 F actory setting See “Operating Instructions Type 8412“ on the website in the User Manuals chapter Type 8412 Appr ovals and certificates Directives CE directive The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable) Pressure equipment directive • The device does not meet the r equirements for “safety accessories” within the meaning of the Pressure Equipment Directive 2014/68/EU. Complying with ar ticle 4, paragraph 1 of 2014/68/EU directive Detailed information on the pressure equipment directive can be found in chapter “2.1. Pressure equipment directive” on page 5. Environment and installation Ambient temperature Operation - 20…+ 4…+ 185 °F) S torage - 40…+ 40…+ 185 °F) T emperature influence ≤ 0.0025 % of the measuring span per K deviation fr om 22 Relative air humidity • During oper ation: ≤ 100 %, without condensation on the out er housing surface of the device During st orage: ≤ %, without condensation Climat e class 3K7 according to EN 60721 Application range Indoors and outdoors (protect this device against electromagnetic interference, ultraviolet rays and the effects of climatic conditions) Degree of protection according to IEC/ EN 60529 IP67 with female connector screwed on Mounting position Installation: unrestricted
5 | 11 Visit product website 2. Appr ovals 2.1. P ressure equipment directive The device conforms to article 4, paragraph 1 of the pressure equipment directive 2014/68/EU under the following conditions: Device used on a pipe Note: The data in the table is independent of the chemical compatibility of the material and the fluid. PS = maximum admissible pr essure, DN = nominal diameter of the pipe Type of fluid Conditions Fluid group 1, article 4, paragraph 1.c.i DN ≤ 25 Fluid gr oup 2, article 4, paragraph 1.c.i DN ≤ 32 or PS*DN ≤ 1000 Fluid group 1, article 4, paragraph 1.c.ii DN ≤ 25 or PS*DN ≤ 2000 Fluid group 2, article 4, paragraph 1.c.ii DN ≤ 200 or PS ≤ 10 or PS*DN ≤ 5000 Device used on a vessel Note: The data in the table is independent of the chemical compatibility of the material and the fluid. PS = maximum admissible pr essure, V = vessel volume Type of fluid Conditions Fluid group 1, article 4, paragraph 1.a.i V > 1 L and PS*V ≤ 25 bar.L or PS ≤ 200 bar Fluid group 2, article 4, paragraph 1.a.i V > 1 L and PS*V ≤ 50 bar.L or PS ≤ 1000 bar Fluid group 1, article 4, paragraph 1.a.ii V > 1 L and PS*V ≤ 200 bar.L or PS ≤ 500 bar Fluid group 2, article 4, paragraph 1.a.ii PS > 10 bar and PS*V ≤ 10000 bar .L or PS 1000 bar 3. Mat erials 3.1. Chemical Resistance Char t – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? V erify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check
6 | 11 Visit product website 4. Dimensions Note: Dimensions in mm 1.) The total height is increased by the height of the used female connector and cable. M12 x 1 Ø 27 G ½" 50 or 100 ≈ 501.) Ø 6 27 27 NPT ½"-14 50 or 100 ≈ 501.) Ø 6 M12 x 1 Ø 27 Ø 25 Ø 20.2 3.8 M12 x 1 Ø 27 ≈ 471.) Ø 6 G ½" according to EN 837 NPT ½" according to EN 837 Process connection: Clamp ¾" according to DIN 32676 series B L L 100 150
7 | 11 Visit product website 5. P roduct operation 5.1. F unctional overview Temperature T A/D Calibration Sensor monitoring Scaling Fine adjustment Filters Decimal places Measuring range monitoring Min./Max. indicator Date/Name Device functions (Profile DS 404) EMERGENCY PDO HEARTBEAT SYNC NMT LSS Probe break/ Probe short-circuit Measured value, 32 bit Status, 8 bit Parameters Measured values Status 12SDO No. Description 1 The measured temperature value is digitized. 2 The temperature signal is adjusted digitally per default. 3 The sensor monitoring continuously checks the correct function of the sensor signal and triggers high-priority emergency frames in the event of an error. 4 The measured temperature value can be scaled to any measuring units (or in % of the measuring range). 5 The fine adjustment features a freely adjustable characteristic line offset. 6 Undesired signal fluctuations can be suppressed using the adjustable filter constant. 7 The measurement output has a freely selectable decimal place. 8 Free choice of upper and lower limits for range monitoring. The result is given as a status byte in addition to the measurement in the PDO frame. 9 The drag pointer (“min./max. index”) function records the minimum and maximum temperature values. 10 The date and name of the last maintenance operation can be saved. 11 The emergency frame is triggered in the event of a sensor fault. 12 The PDO frame contains a 32-bit measurement and a 8-bit status. The measurement output can be controlled by means of different trigger conditions. 13 SDO frames can be used to set parameters and to request measured values and statuses. 14 The heartbeat signal can be used to additionally monitor the function of the transmitter. 15 The sync command can also be used to control the transfer of the measured values. 16 The NMT frames are for the purpose of controlling the operating status of the transmitter. 17 The CAN Node ID and the CAN baud rate are set either with LSS or SDO.
8 | 11 Visit product website 6. P roduct accessories Note: To set up a device, please use the USB-büS interface Type 8923 in combination with the Bürkert software tool Communicator Type 8920. See Software manual Type 8920 for mor e information. Accessories No. Description
1 Quick-Start
2 Power supply:100…240 V AC/24 V DC 1 A and adaptors for power supply
3 büS terminating resistor on büS Y-splitter 4 5 pin M12 male connector wired on free end cable 5 büS connection cable with 5 pin M12 plug, micro USB B plug 6 büS adapter with 5 pin M12 plug, A-coded to 5 pin M12 plug, A-coded 7 büS stick (USB to büS/CANopen adaptor) 8 büS service cable with 5 pin M12 plug, mini USB and circular plug-in con- nectors for power supply
9 Magnetic key
10 CD - Communicator (30-day license without registration, update and licens-
ing over Bürkert home page). It is recommended to download and install the Communicator software from the homepage to use the latest version. 7. Or dering information 7.1. Bürk ert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and fast delivery You want to find your desired Bürkert product or spare part quickly and order dir ectly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 7.2. Bürk ert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter
9 | 11Visit product website 7.3. Or dering chart Note: All following versions have a 10…30 V DC operating voltage and a CANopen digital interface. Process connection Temperature range Probe length Article no. [°C] [mm] G ½" - 50…+ 150 50 574638 100 574639 NPT ½" 50 574640 100 574641 Clamp ¾" 25 574320 30 574321 50 572034 100 572035 150 572036 Further versions on request Process connection Screw-in thread G ¼", G ⅜", M14 x 1.5, M18 x 1.5 and M20 x 1.5 Temperature 50…+ 450 Additional Pt1000 t emperature sensor, two-wire circuit, class B according to EN 60751:2009 / IEC 60751:2008 Inser tion length: 150, 200 or 250 mm 7.4. Or dering chart accessories Note: büS communication specifications ar e based on CANopen. All following accessories can be used for C ANopen as well. Description Article no. System connection Type ME43 Gateway / Interface büS/Ethernet (Profinet, Ethernet/IP, Modbus TCP, EtherCAT) 307390 büS/Profibus DP 307393 Interface accessories büS Stick Set USB-büS-Interface Set 1, Type 8923. Detailed information can be found in chapter “6. Product ac- cessories” on page 8. 772426 USB-büS Interface Set 2, Type 8923 (only büS Stick, cable and büS service cable) 772551 Connectors and sockets büS Y-connector, 5 pin M12 female to 5 pin M12 male and 5 pin M12 female 772420 büS Y-connector, 5 pin M12 female to 5 pin M12 male and 5 pin M12 female (power interrupt) 772421 büS adaptor M12 male A-coded - M12 male A-coded 772867 büS termination, 5 pin M12 male cable plug 772424 büS termination, 5 pin M12 female cable plug 772425 Extensions 5 pin M12 female and male straight cable plug moulded on cable (0.5 m, shielded) 772403 5 pin M12 female and male straight cable plug moulded on cable (1 m, shielded) 772404 5 pin M12 female and male straight cable plug moulded on cable (3 m, shielded) 772405 5 pin M12 female and male straight cable plug moulded on cable (5 m, shielded) 772406 5 pin M12 female and male straight cable plug moulded on cable (10 m, shielded) 772407 5 pin M12 female and male straight cable plug moulded on cable (20 m, shielded) 772408
10 | 11Visit product website Description Article no. Software Software Bürkert Communicator Download Type 8920
Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa Russia United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -
74653 Künzelsau
www.burkert.com