Visit product website  DATA SHEET Type 8619  multiCELL - Multi-chan- nel and multi-function transmitter/controller Type 8611  eCONTROL - Universal controller Type 8692  Digital electropneu- matic Positioner for the integrated mounting on process control valves Type 8644  Remote Process Actu- ation Control System AirLINE 1000385105 | Standard | EU | en | 202109 | 03 Radar level meter for liquids suitable for use in applications with aggressive fluids as well as with hygienic requirements

  • Continuous level measurement up to 30 m, 4…20 mA, 2-wire
  • Available process connections: Plastic horn antenna, thread (G, NPT and flange (DN50, DN100), clamp (2")
  • Excellent radar signal focusing and high measurement dynamics
  • Adjustable using the display/configuration module and keys, alter- natively via PC-Tool with DTM The Type 8139 is a non-contact radar level measuring device for continuous level measurement. It is available with:
  • int egrated antenna (G- or NPT connection), especially suitable for level measur ement of aggressive liquids, with special advantages for small vessels.
  • plastic horn antenna (with mounting bracket), especially suitable for meas- urements in open flumes or gauge measurement in water.
  • flange connection (DIN 2501) with encapsulated antenna system,
  • clamp connection (DIN 32676, ISO 2852) with encapsulated antenna sys- tem for hygienic requirements. The high focus of the radar signal and the high measurement dynamics allow e xcellent measurement results even in small, narrow and high containers, as the risk of signal interference by installations, constructions and vessel walls is much lowered. Signal damping, e.g. due to signal running length, foam build-up, low DK values of the liquids, has a much smaller effect. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 8139 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 19 Visit product website  Table of contents 1. Gener al technical data 3 P roduct versions 2.2. Thread with integrated antenna 40 mm 2.3. Flange with encapsulated antenna 2.4. Hygiene connection with encapsulated antenna system 3. Approvals 7 4. Materials 7 5. Dimensions 8 5.2. Thread with integrated antenna 40 mm 5.3. Flange with encapsulated antenna 5.4. Hygiene connection with encapsulated antenna system 6. Performance specifications 11 6.2. Temperature derating diagram Plastic horn antenna 80 mm Thread with integrated antenna 40 mm Flange with encapsulated antenna 7. P roduct installation 13 Plastic horn antenna 80 mm with mounting bracket Plastic horn antenna 80 mm with 8. P roduct operation 14 8.2. P roduct operation notes Set up with display/configuration module Set up with PACTware™/DTM and HART communication 9. P roduct accessories 16 10. Or dering information 10.2. Bürkert product filter 10.3. Or dering chart 10.4. Ordering chart accessories

3 | 19 Visit product website  1. Gener al technical data Product properties Materials Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “4.1. Chemical Resistance Chart – Bürkert resistApp” on page 7. Non wetted parts Depending on antenna system. Detailed information can be found in chapter “2. Product versions” on page 5. Housing Plastic PBT (Polyester), PPS and stainless steel 316L (1.4404) Cover PC transparent Seal between housing and housing cover EPDM C able gland PA Blind plug PA Ground terminal Stainless steel 316L Wetted parts Depending on antenna system. Detailed information can be found in chapter “2. Product versions” on page 5. Dimensions Detailed information can be found in chapter “5. Dimensions” on page 8. Weights Approx. 2…17.2 kg (depending on process connection and antenna) Measuring variable Distance between the end of the sensor antenna and the product surface. Measuring range Max. 30 m (depending on antenna system). Detailed information can be found in chapter “2. Product versions” on page 5. Beam angle1.) Depending on antenna system. Detailed information can be found in chapter “2. Product versions” on page 5. Damping (63 of the input variable) 0…999 s, adjustable Step response time2.)3.) ≤ 3 s P roduct accessories Display LCD in full dot matrix (optional, must be ordered separately) Performance data Blocking distance Null Measurement deviation According to EN 60770 1 mm for liquids (measuring distance 0.25 m). Detailed infor- mation can be found in chapter “6.1. Measurement deviation diagram” on page 11. Measuring range resolution 1 mm Measuring frequency W-Band (80 GHz technology) Measuring cycle time2.) Approx. 700 ms T emperature drift < 0.03 %/10K relating to the 16 mA span or max. 0.3 Repeatability4.) ≤ 1 mm V ibration resistance Depending on antenna system. Detailed information can be found in chapter “2. Product versions” on page 5. Shock resistance 100 g, 6 ms according to EN 60068 (mechanical shock) Electrical data Operating voltage (Un) 12…35 V DC Starting current ≤ 3.6 mA; 10 mA for 5 ms after switching on Load resistor (Un - Umin)/0.022 A Output signal 4…20 mA/HART Signal resolution 0.3 µA Range of the output signal 3.8…20.5 mA/HART (default setting) Fault signal Current output: mA value unchanged, 20.5 mA, 22 mA or 3.6 mA (adjustable) Max. output current 22 mA Residual ripple (at DC) For 12 V< Un < 18 V: ≤ 0.7 Veff (16…400 Hz) F or 18 V< Un < 35 V: ≤ 1.0 Veff (16…400 Hz) V oltage supply cable • Cable diameter: 5…9 mm

  • Wire cross-section (spring-loaded terminals): – massive wire, stranded wire: – str anded wire with end sleeve: Media data P rocess temperature Depending on antenna system. Detailed information can be found in chapter “2. Product versions” on page 5.

4 | 19 Visit product website  Process pressure Depending on antenna system. Detailed information can be found in chapter “2. Product versions” on page 5. Process/Port connection & communication Process connection • Mounting bracket 170 mm (supplied as standard) or 300 mm (accessory) (version with plastic horn ant enna)

  • Thread G or NPT or 1½" (version with integrated horn antenna)
  • Flange DN50, DN100 DIN 2501 (version with encapsulated antenna system)
  • Clamp DIN 32676, ISO 2852 (hygiene connection version with encapsulated anten- na system) Electrical connection Cable gland M20 x 1.5 Approvals and Certificates Standards Degree of protection according to IEC/ EN 60529 IP66/IP67 with cable plug mounted and tightened M20 x 1.5 Over voltage category according to IEC 61010 Category III Protection class according to IEC 61010 Class III Directives CE directives The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable) NAMUR recommendations NE21 Electromagnetic compatibility of equipment NE43 Signal level for fault information from measuring transducers NE53 Compatibility of field devices and display/adjustment components NE107 Self-monitoring and diagnosis of field devices Approvals ATEX/IECEx EN IEC 60079 EN 60079 11, EN 60079 Detailed information can be found in chapter “3.1. ATEX/IECEx-Certification” on page Environment and installation Ambient temperature Operation and storage: 40…+ 40…+ 176 °F) T emperature derating Depending on antenna system. Detailed information can be found in chapter “6.2. Tem- perature derating diagram” on page 12. Relative air humidity 20…85 without condensation Height above sea level By default: max. 2000 m With connected overvoltage protection: max. 5000 m Pollution degree Degree (when used with fulfilled housing protection) 1.) Outside the specified beam angle, the energy level of the radar signal is 50 % (- 3 dB) less 2.) With operating voltage Un ≥ 24 V DC 3.) T ime span after a sudden distance change from 1…5 m until the output signal reaches of the final value for the first time (IEC 61298 2). 4.) Already included in the measurement deviation

5 | 19 Visit product website  2. P roduct versions 2.1. Plastic horn antenna 80 mm Product details Material Non wetted parts:

  • antenna cone in PBT-GF
  • mounting bracket and fixing screws, in stainless steel 316L Wetted parts:
  • focus lens in PP Beam angle 3° Measuring range 0…30 m Vibration resistance • With mounting bracket: 1 g with 5…200 Hz according to EN 60068 (vibr ation at resonance)
  • With adapter flange (as an option): 2 g with 5…200 Hz according to EN 60068 (vibration at resonance) Process temperature - 40…+ 40…+ 176 °F) P rocess pressure With adapter flange: 1…1 bar 100…100 kPa/- 14.5…14.5 psig) Accessories Material Non wetted parts:
  • fixing screws for adapter flange in stainless steel 304 Wetted parts:
  • adapter flange for PP-GF30 black
  • seal for adapter flange in FKM (COG VI500) 2.2. Thr ead with integrated antenna 40 mm Product details Material Wetted parts:
  • process connection in stainless steel 316L
  • antenna in PEEK
  • seal Antenna system in FKM
  • process seal in NBR with aramid fibres Beam angle • 14° for version or NPT¾
  • 7° for version G 1½ or NPT 1½ Measuring range • 0…10 m for version or NPT¾
  • 0…20 m for version G 1½ or NPT 1½ Vibration resistance 4 g with 5…200 Hz according to EN 60068 (vibration at resonance) Process temperature1.) - 40…+ 130 °C (- 40…+ 266 °F) P rocess pressure - 1…20 bar 100…2000 kPa/- 14.5…290.1 psig) 1.) T ake into account reduced ambient temperature. Detailed information can be found in chapter “6.2. Temperature derating diagram” on page 12

6 | 19 Visit product website  2.3. Flange with encapsulat ed antenna system Product details Material Wetted parts:

  • flange plating, antenna encapsulation in PTFE
  • seal in PTFE Beam angle • 6° for version DN50
  • 3° for version DN100 Measuring range • 0…25 m for version DN50
  • 0…30 m for version DN100 Vibration resistance 4 g with 5…200 Hz according to EN 60068 (vibration at resonance) Process temperature1.) - 40…+ 130 °C (- 40…+ 266 °F) SIP pr ocess temperature + 150 302 °F), vapour stratification up to 2 h Process pressure - 1…16 bar 100…1600 kPa/- 14.5…232 psig) 1.) T ake into account reduced ambient temperature. Detailed information can be found in chapter “6.2. Temperature derating diagram” on page 12 2.4. Hygiene connection with encapsulat ed antenna system Product details Material Wetted parts:
  • hygienic antenna encapsulation in PTFE
  • seal in PTFE Surface roughness of the antenna encapsulation Ra 0.8 µm Beam angle 6° Measuring r ange 0…25 m Process temperature - 40…+ 130 40…+ 266 °F) SIP P rocess temperature + 150 302 °F), vapour stratification up to 2 h Process pressure - 1…16 bar 100…1600 kPa/- 14.5…232 psig)

7 | 19 Visit product website  3. Appr ovals 3.1. A TEX/IECEx-Certification Note: Devices with Ex certification have different technical data, see Supplement ATEX/IECEx Type 8139  under user manual. Certificate Description EU-Type Examination Certificate Number: PTB 20 A TEX 2003X / IECEx PTB 20 ATEX 2003X ATEX

  • II Ex ia IIC T6…T1 Ga
  • II 1/2G Ex ia IIC T6…T1 Ga/Gb
  • II Ex ia IIC T6…T1 Gb IECEx
  • Ex ia IIC T6…T1 Ga
  • Ex ia IIC T6…T1 Ga/Gb
  • Ex ia IIC T6…T1 Gb Measures to comply with ATEX/IECEx requirements: refer to the Supplement ATEX/IECEx Type 8139  under user manual. The Ex. certification is only valid if the Bürkert device is used as described in the supplement A TEX/IECEx. If unauthorized changes are made to the device, the Ex. certification becomes invalid. 4. Mat erials 4.1. Chemical Resistance Char t – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our r esistApp. Start Chemical Resistance Check

8 | 19 Visit product website  5. Dimensions 5.1. Plastic horn antenna 80 mm Note: Specifications in mm 8.5 986 129 12 170 ø 80.5 approx. 76 123 127 ø 75 ø 107 ø 115 125 2.5

9 | 19 Visit product website  5.2. Thr ead with integrated antenna 40 mm Note: Specifications in mm AF 36 NPT ¾ ø 24 Version NPT ¾ (ASME B1.20.1)Version G ¾ (DIN 3852-E) ø 24 AF 36 G ¾ ø 80.5 approx. 76 123 127 G 1½ 101 ø 42.5 AF 55 Version G 1½ (DIN 3852-E) Version NPT 1½ (ASME B1.20.1) NPT 1½ AF 55 101 ø 42.5

10 | 19 Visit product website  5.3. Flange with encapsulat ed antenna system Note: Specifications in mm Version DN50 PN40, up to 130 °C ø45 ø102 ø 165 Flange DIN 2501, DN50 PN40 form C Bolt circle ø125; 4 x ø18 129 ø 75 ø 158 Version DN100 PN16, up to 130 °C ø 220 Flange DIN 2501, DN50 PN40 form C Bolt circle ø180; 8 x ø18 ø 80.5 approx. 76 123 127

11 | 19 Visit product website  5.4. Hygiene connection with encapsulat ed antenna system Note: Specifications in mm68.516.5 ø 40 ø 51.6 ø 43.8 ø 64 Version clamp 2" PN16, DIN 32676, ISO 2852 6. P erformance specifications 6.1. Measur ement deviation diagram Note: The drawing shows the measurement deviation under reference conditions of Type 8139 with thread and integrated horn antenna. This applies accor dingly to all versions. 0.25 - 10 1- 1 0 [mm] [m] Max. Recommended (depending on version) Antenna edge Reference plane Measuring range Measurement deviation

12 | 19 Visit product website  6.2. T emperature derating diagram Plastic horn antenna 80 mm 10 20 30 40 50 60 Process temperature [°C] Ambient temperature [°C] -30 -20 -10 0-30 -20 -10 -40 -40 Thread with integrated antenna 40 mm 10 20 30 40 50 60 Process temperature [°C] Ambient temperature [°C] 70 80 90 100 110 120 -30 -20 -10 130 -40 -40 -30 -20 -10 Flange with encapsulated antenna system 10 20 30 40 50 60 Process temperature [°C] Ambient temperature [°C] 70 80 90 100 110 120 -30 -20 -10 0-30 -20 -10 -40 -40 130

13 | 19 Visit product website  7. P roduct installation 7.1. Mounting options Plastic horn antenna 80 mm with mounting bracket The mounting bracket allows simple mounting of the instrument on a wall, ceiling or boom. Especially in the case of open flumes, this is a simple and effective way to align the sensor to the surface of the liquids. Mounting bracket - Ceiling mounting Mounting bracket - Wall mounting The instrument is normally mounted vertically with a bracket on the ceiling. This allows the sensor to swivel up to 180° for optimal alignment and r otate for optimal connection. Alternatively, the bracket can be mounted horizontally or diagonally. > 200 mm Plastic horn antenna 80 mm with flange An adapter flange is available for mounting the device on a socket. Adapter flange The adapter flange is available from DN 100. It is permanently connected with the radar sensor and sealed. Process seal Adapter flange Connection screw

14 | 19 Visit product website  8. P roduct operation 8.1. Measuring principle The radar measuring device for the measurement of liquid levels consists of a housing with electronics and a process connection with antenna. The antenna of the radar sensor emits a continuous radar signal. This is reflected by the liquid surface and received by the antenna as an echo. Radar waves propagate at the speed of light. The frequency difference between the transmitted and r eceived signal is proportional to the distance to the liquid surface. The filling level is calculated and converted into a corresponding output signal and tr ansmitted as a measured value. The measuring range of the radar level measuring device begins physically at the end of the antenna. However, the min./max. adjust- ment begins at the reference plane. The reference plane is different depending on the sensor version.

  • Plastic horn antenna: the reference plane is the sealing surface on the lower edge
  • Thread with integrated horn antenna: the reference plane is the sealing surface at the bottom of the hexagon
  • Flange with encapsulated antenna system: the reference plane is the lower edge of the flange plating
  • Hygiene connection with encapsulated antenna: the reference plane is the highest contact point between sensor process fitting and welded socket Reference plane Thread with integrated horn antenna Flange with encapsulated antenna system Hygiene connection with encapsulated antenna Plastic horn antenna 80 mm

15 | 19 Visit product website  8.2. P roduct operation notes Note: The measuring device can be adjusted with:

  • the display/configuration module
  • the suitable Bürkert DTM in conjunction with a software according to the FDT/DTM standard, e.g. PACTware™ and PC The entered parameters are generally saved in the measuring device Type 8139. Optionally, parameters may also be uploaded and downloaded with the display/configuration module or saved in a file by using PACTware™/8139 DTM. Set up with display/configuration module Display/configuration module Description The display/configuration module can be inserted into the measuring device and removed again at any time. It is not necessary to interrupt the power supply. The measuring device is adjust ed via the four keys of the display/configuration module. Set up with PACTware™/DTM and HART communication Assembly Description PACTwareTM Bürkert DTM Power supply unit1 The measuring device can be operated thanks to PACTware™, via HAR T communication. An interface adapter is necessary for the adjustment with PACTware™. For the setup of the Type 8139, the D TM in the actual version must be used. The basic version of DTM incl. PACTware™ is available as a free-of-charge download from the int ernet at www.burkert.com Connecting the PC via HART No. Description

1 Measuring device Type 8139

2 HART-USB

3 Resistance

250 Ω Necessary components:

  • measuring device Type 8139
  • PC with PACTware™ and suitable Bürkert DTM
  • HART-USB Modem
  • resistance approx. 250 Ω
  • power supply unit

16 | 19 Visit product website  9. P roduct accessories Note: The accessories for the plastic horn antenna 80 mm must be ordered separately. Accessory Description 125 2.5 300 129 12 Mounting bracket 300 mm 36.5 17.5 ø 98 ø 180 ø 220 ø 18 (8 x 45°) Adapter flange DN100 PN16 FKM / PPH 36.5 17.5 ø 98 ø 190.5 ø 228.6 ø 19.1 (8 x 45°) Adapter flange ASME (ANSI B16.5) 4" 150PSI FKM / PPH

17 | 19 Visit product website  10. Or dering information 10.1. Bürk ert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and fast delivery You want to find your desired Bürkert product or spare part quickly and order dir ectly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 10.2. Bürk ert product filter Bürkert product filter – Get quickly to the right product Y ou want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily Try out our product filter 10.3. Or dering chart Note: All following versions are supplied without display/configuration module. Description Operating voltage Output Process connection Electrical connection Article no. Plastic horn antenna 80 mm 12…35 V DC 4…20 mA/HART wires) Mounting bracket 170 mm C able gland M20 1.5 570592  Thread with integrated anten- na 40 mm, PN20 12…35 V DC 4…20 mA/HART wires) G ¾ Cable gland M20 1.5 570620  NPT ¾ Cable gland M20 1.5 570621  G 1½ Cable gland M20 1.5 570590  NPT 1½ Cable gland M20 1.5 570591  Flange with encapsulated ant enna system 12…35 V DC 4…20 mA/HART wires) DN50 DIN2501, 40 bar C able gland M20 1.5 570606  DN100 DIN2501, 16 bar C able gland M20 1.5 570607  Hygiene connection with en- capsulated antenna system 12…35 V DC 4…20 mA/HART wires) Clamp 2" Cable gland M20 1.5 570605  Further versions on request Material e.g. FFKM, PFA bar Pressure e.g. 1…6 bar, 1…10 bar Process connection e.g. compression flange, adapter flange DN150, ANSI, JIS, clamp Additional Wit display Temperature e.g. 40…+ 200 Approval ATEX/IECEx-Certification

18 | 19 Visit product website  10.4. Or dering chart accessories Description Article no. Set with reductions M20 x 1.5/NPT½ neoprene flat seals for cable gland screw-plugs M20 x 1.5 551782  Hart-USB Modem 560177  Set with a display/configuration module, a transparent cover and a seal ring 559279  Set with a transparent cover and a seal ring 561006  Mounting bracket 300 mm 559839  Adapter flange DN100 PN16 FKM PPH 560437  Adapter flange ASME (ANSI B16.5) 150PSI FKM PPH 560436 

Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa Russia United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -