7506GX2 REDLION | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
7506GX2 Industrial Ethernet Switch N-Tron Networking Series Managed Industrial Ethernet SwitchTHE INDUSTRIAL NETWORK COMPANY 7506GX2 Remote Monitoring Options - For ease of con fi guration and monitoring, the 7506GX2 offers web browser management and N-View OLE for process control (OPC) server software. The N-TRON N-View software can be combined with popular HMI software packages to add network traf fi c monitoring, trending, and alarming to any application using N-TRON switches. In addition, SNMP is available for switch link and status monitoring. The status LED can be confi gured to respond to power failure on power input 1 or input 2, N-Link fault, port usage fault, N-Ring broken, partial break high, partial break low, or if multiple ring managers are detected. N-Ring Technology - N-TRON's 7506GX2 ring manager using N-TRON's N-Ring technology offers expanded ring size capacity, detailed fault diagnostics, and a standard healing time of ~30ms. The 7506GX2 ring manager periodically checks the health of the ring via heart beat packets. If the ring manager stops receiving these health check packets, it converts the ring to a linear topology within ~30ms. When all switches in the ring are N-TRON fully managed switches, a detailed ring map and fault location chart will also be provided on the ring manager’s web browser and OPC server to identify the health status of the ring. N-Link™ allows the linking of two N-Rings. Up to 250 fully managed N-TRONswitches can participate in N-Ring topologies. Industrial Packaging and Specifi cations - The 7506GX2 is designed to operate in industrial environments. It is housed in a rugged extruded aluminum DIN-Rail enclosure. It has extended industrial specifi cations and features to meet or exceed the operating parameters of connected equipment. These include extended temperature ratings, extended shock and vibration specs, redundant power inputs, and high MTBF (greater than 2M hours). Ease of Use - The 10/100/1000BaseT(X) ports are auto sensing and auto confi guring. Each copper port is automatically negotiated for maximum speed and performance by default, but can also be hard coded through the user interface. A high speed processor allows wire speed capability on all 10/100/1000BaseT(X) ports simultaneously. PRODUCT FEATURES
- Four 10/100/1000BaseT(X) RJ-45 Ports
- Two SFP (Mini-GBIC) Gigabit Transceivers (Optional)
- 1000BaseSX/LX Fiber with LC style connectors or
- 1000BaseT Copper with RJ-45 connectors
- -40 o to 80oC Operating temperature
- ESD and Surge Protection Diodes on all Ports
- Auto Sensing 10/100/1000BaseT(X), Duplex, and MDIX
- Store-and-forward Technology
- Jumbo Frame Support
- Rugged DIN-Rail Enclosure
- Onboard Temperature Sensor
- Redundant Power Inputs (10-49VDC)
- Confi gurable Bi-Color Fault Status LED Fully Managed Features:
- SNMP v1, v2, v3 and Web Browser Management
- Confi guration backup via Optional SD card
- EtherNet/IP™ CIP Messaging
- Detailed Ring Map and Fault Location Charting
- N-Ring ™ Technology with ~30ms Healing
- N-View ™ OPC Monitoring
- N-Link ™ Redundant N-Ring Coupling
- IGMP Auto Con fi guration
- 802.1Q tag VLAN and Port VLAN
- 802.1p QoS and Port QoS, and DSCP
- LLDP (Link Layer Discovery Protocol)
- Port Trunking
- Port Mirroring
- 802.1d, 802.1w, 802.1D RSTP
- DHCP Server, Option 82 relay, Option 61, IP Fallback
- Local Port IP Addressing
- Port Security—MAC Address Based
7506GX2 Specifi cations Switch Properties Number of MAC Addresses: 4000 Aging Time: Programmable Latency Typical: 1.6 μs Switching Method: Store-and-Forward Case Dimensions Height: 3.8" (9.6cm) Width: 2.0" (5.1cm) Depth: 3.9" (9.9cm) Weight (max): 1.1lbs (0.48kg) DIN-Rail Mount: 35mm Electrical Redundant Input Voltage: 10-49 VDC (Regulated) Input Current (max): 440mA max.@24VDC BTU/hr: 36@24VDC N-TRON Power Supply: NTPS-24-1.3 (1.3A@24V) Environmental Operating Temperature: -40oC to 80oC Storage Temperature: -40oC to 85oC Operating Humidity: 5% to 95% (Non Condensing) Operating Altitude: 0 to 10,000 ft. Shock and Vibration (bulkhead mounted) Shock: 200g @ 10ms Vibration/Seismic: 50g, 5-200Hz, Triaxial Reliability MTBF: >2 Million Hours Recommended Wiring Clearance Front: 4" (10.16 cm) Top: 1" (2.54 cm) Network Media 10BaseT: >Cat3 Cable 100BaseTX: >Cat5 Cable 1000BaseT: >Cat5e Cable Connectors 10/100/1000BaseT(X):Four (4) RJ-45 Copper Ports 1000BaseT: Up to Two (2) RJ-45 Gigabit Copper Ports (optional) 1000BaseSX/LX: Up to Two (2) LC Duplex Gigabit Fiber Ports (optional) Regulatory Approvals FCC Title 47, Part 15, Subpart B - Class A; ICES-003 - Class A UL /cUL: Class I, Div 2, Groups A, B, C, D and T4 ANSI/ISA 12.12.01-2007 CE: EN61000-6-2:2001; EN61000-6-4:2007 GOST-R Certi ed, RoHS Compliant Designed to comply with: IEEE 1613 for Electric Utility Substations NEMA TS1/ TS2 for Traf c control THE INDUSTRIAL NETWORK COMPANY ® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Product names mentioned herein are for identi fi cation purposes only and may be trademarks and/or registered trademarks of their respective company. Speci fi cations subject to change without notice. The responsibility for the use and application of N-TRON products rests with the end user. N-TRON makes no warranties as to the fi tness or suitability of any N-TRON product for any speci fi c application. N-TRON Corporation shall not be liable for any damage resulting from the installation, use, or misuse of this product. Printed in USA. Contact Information N-TRON Corp. N-TRON Asia N-TRON Europe GmbH 820 S. University Blvd., Suite 4E Suite #: 2267, 22/F, One Lujiazui Alte Steinhauserstr 19 Mobile, AL 36609 USA 68 Yin Cheng Road Center, 6330 Cham / Zg Switzerland TEL: (251) 342-2164 Pudong New Area TEL: +41 41 7406636 FAX: (251) 342-6353 200120 Shanghai, P.R. China FAX: +41 41 7406637 Website: www.N-TRON.com Phone: +86 (0) 21 6194 6777 Email: N-TRON_info@N-TRON.com Fax: +86 (0) 21 6194 6699 Fiber Length 550m for 50/125μm 275m for 62.5/125μm* 10km 40km 80km ** TX Power Min -9.5dBm -9.5dBm -2dBm 0dBm RX Sensitivity Max -17dBm -20dBm -22dBm -24dBm Wavelength 850nm 1310nm 1310nm 1550nm Laser Type VCSEL FP DFB DFB SFP Gigabit Fiber Transceiver Characteristics * SX Fiber Optic Cable ** LX Fiber Optic Cable
7506GX2 Industrial Ethernet Switch Ordering Information 7506GX2 Four 10/100/1000BaseT(X) Ports and two SFP ports without (optional) modules 7506GX2-SX Four 10/100/1000BaseT(X) Ports and two SFP ports with 2 NTSFP-SX Multimode modules installed 7506GX2-LX-10 Four 10/100/1000BaseT(X) Ports and two SFP ports with 2 NTSFP-LX-10 Singlemode modules installed NTSFP-TX Optional SFP (Mini-GBIC) Transceiver with One 1000BaseT GB Copper Port NTSFP-SX Optional SFP (Mini-GBIC) Transceiver with One 1000BaseSX Multimode GB Fiber Optic Port NTSFP-LX-ZZ Optional SFP (Mini-GBIC) Transceiver with One 1000BaseLX Singlemode GB Fiber Optic Port NTCD-128 Optional SD Card, Con guration Device NTPS-24-1.3 N-TRON Power Supply - (1.3 Amp @ 24VDC) 1000-PM Panel Mount kit URMK Universal Rack Mount Kit Where: ZZ = 10, 40, or 80 for GB Singlemode THE INDUSTRIAL NETWORK COMPANY ® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Specifi cations subject to change without notice. Printed in USA. 7506GX2 Industrial Ethernet Switch Ordering Information 7506GX2 Four 10/100/1000BaseT(X) Ports and two SFP ports without (optional) modules 7506GX2-SX Four 10/100/1000BaseT(X) Ports and two SFP ports with 2 NTSFP-SX Multimode modules installed 7506GX2-LX-10 Four 10/100/1000BaseT(X) Ports and two SFP ports with 2 NTSFP-LX-10 Singlemode modules installed NTSFP-TX Optional SFP (Mini-GBIC) Transceiver with One 1000BaseT GB Copper Port NTSFP-SX Optional SFP (Mini-GBIC) Transceiver with One 1000BaseSX Multimode GB Fiber Optic Port NTSFP-LX-ZZ Optional SFP (Mini-GBIC) Transceiver with One 1000BaseLX Singlemode GB Fiber Optic Port NTCD-128 Optional SD Card, Con guration Device NTPS-24-1.3 N-TRON Power Supply - (1.3 Amp @ 24VDC) 1000-PM Panel Mount kit URMK Universal Rack Mount Kit Where: ZZ = 10, 40, or 80 for GB Singlemode THE INDUSTRIAL NETWORK COMPANY ® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Specifi cations subject to change without notice. Printed in USA. www.redlion.net Connect. Monitor. Control. Americas sales@redlion.net Asia-Pacific asia@redlion.net Europe Middle East Africa europe@redlion.net +1 (717) 767-6511 ADLD0261 080116 © 2016 Red Lion Controls, Inc. All rights reserved. Red Lion, the Red Lion logo, N-Tron and Sixnet are registered trademarks of Red Lion Controls, Inc. All other company and product names are trademarks of their respective owners. As the global experts in communication, monitoring and control for industrial automation and networking, Red Lion has been delivering innovative solutions for over forty years. Our automation, Ethernet and cellular M2M technology enables companies worldwide to gain real-time data visibility that drives productivity. Product brands include Red Lion, N-Tron and Sixnet. With headquarters in York, Pennsylvania, the company has offices across the Americas, Asia-Pacific and Europe. Red Lion is part of Spectris plc, the productivity-enhancing instrumentation and controls company. For more information, please visit www.redlion.net.