© PHOENIX CONTACT - 03/20077118_en_02 AUTOMATIONWORX I L BI B2 4D I 1 6 - D S U B Data Sheet
Description
The ILB IB 24 DI16-DSUB module is designed for use within an INTERBUS network. It is used to acquire digital signals. INTERBUS Features – Remote bus connection via D-SUB connector – 500 kbps transmission speed – Diagnostic and status indicators Input Features – Connections for 16 digital sensors – Connection of sensors in 2 and 3-wire technology – Maximum permissible load current per sensor: 125 mA – Maximum permissible load current from the sensor supply: 2.0 A – Diagnostic and status indicators Inline Block IO Module for INTERBUS With 16 Digital Inputs; Bus Connection via D-SUB Connectors Please refer to the "Mounting and Removing Inline Block IO Modules" application note (see "Ordering Data" on page 2). Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at
I L BI B2 4D I 1 6 - D S U B 7118_en_02 PHOENIX CONTACT 2 Ordering Data Product Description Type Order No. Pcs./Pkt. Inline Block IO module for INTERBUS with 16 digital inputs; bus connection via D-SUB connectors ILB IB 24 DI16-DSUB 2878421 1 Accessories: Connectors Description Type Order No. Pcs./Pkt. D-SUB connector (female connector), solder connection SUBCON 9/F-SH 2761499 1 D-SUB connector (male connector), solder connection SUBCON 9/M-SH 2761509 1 Accessories: Connectors as Replacement Item Description Type Order No. Pcs./Pkt. Connector for the supply (4-pos. MINI COMBICON) FK-MCP 1,5/5-STF-3,81 1851258 50 Connector for the supply (5-pos. MINI COMBICON) FK-MCP 1,5/6-STF-3,81 1851261 50 Connector for digital 4-channel or 16-channel Inline input terminals, with color print IB IL SCN-12-ICP 2727611 10 Accessories: Other Description Type Order No. Pcs./Pkt. Recommended end clamp; placed both to the right and left of the module to secure it on the DIN rail CLIPFIX 35-5 3022276 50 Documentation Description Type Order No. Pcs./Pkt. "Mounting and Removing Inline Block IO Modules" application note AH ILB INSTALLATION 9014931 1 "INTERBUS Addressing" data sheet DB GB IBS SYS ADDRESS 9000990 1 "Addressing of 16-Channel ILB Modules" application note AH ILB 24 DI/DO 16 ADDRESS 9014962 1 "General Introduction to the INTERBUS System" user manual IBS SYS INTRO G4 UM E 2745211 1 "Configuring and Installing INTERBUS" user manual IBS SYS PRO INST UM E 2743802 1
I L BI B2 4D I 1 6 - D S U B 7118_en_02 PHOENIX CONTACT 3 Technical Data Housing Dimensions Figure 1 Housing dimensions of the module (dimensions in mm) General Data Housing dimensions with connectors (width x height x depth) 95 mm x 55 mm x 141 mm Weight 254 g (with connectors) Operating mode Process data mode with 1 word Transmission speed 500 kbps Connection method for sensors 2 and 3-wire technology 120 141 7118B003 Ambient Conditions Regulations Developed according to VDE 0160/EN 50178/IEC 62103, UL 508 Ambient temperature (operation) -25°C to +60°C Ambient temperature (storage/transport) -25°C to +85°C Humidity (operation/storage/transport) 10% to 95%, according to EN 61131-2 Air pressure (operation) 80 kPa to 108 kPa (up to 2000 m above sea level) Air pressure (storage/transport) 66 kPa to 108 kPa (up to 3500 m above sea level) Degree of protection according to IEC 60529 IP20 Class of protection Class 3 according to VDE 0106/IEC 60536 Air and creepage distances According to DIN VDE 0110/IEC 60664, IEC 60664A, DIN VDE 0160/EN 50178/IEC 62103 Housing material Plastic, PVC-free, PBT, self-extinguishing (V0) Pollution degree according to EN 60664-1/IEC 60664-1, EN 61131-2/IEC 61131-2 2; condensation not permitted during operation Surge voltage class II
I L BI B2 4D I 1 6 - D S U B 7118_en_02 PHOENIX CONTACT 4 Electrical Isolation/Isolation of the Voltage Areas Test Distance Test Voltage Incoming remote bus / outgoing remote bus 500 V AC, 50 Hz, 1 min Incoming remote bus / I/O 500 V AC, 50 Hz, 1 min Incoming remote bus / functional earth ground 500 V AC, 50 Hz, 1 min Outgoing remote bus / I/O 500 V AC, 50 Hz, 1 min Outgoing remote bus / functional earth ground 500 V AC, 50 Hz, 1 min I/O / functional earth ground 500 V AC, 50 Hz, 1 min Mechanical Requirements Vibration test, sinusoidal vibrations according to EN 60068-2-6/IEC 60068-2-6 5g load, 2.5 hours in each space direction Shock test according to EN 60068-2-27/IEC 60068-2-27 25g load for 11 ms, half sinusoidal wave, 3 shocks in each space direction and orientation Broadband noise according to EN 60068-2-64/IEC 60068-2-64 0.78g load, 2.5 hours in each space direction Conformance With EMC Directive 89/336/EEC Noise Immunity Test According to EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2 IEC 61000-4-2 Criterion B 6 kV contact discharge 8 kV air discharge Electromagnetic fields EN 61000-4-3 IEC 61000-4-3 Criterion A Field strength: 10 V/m Fast transients (burst) EN 61000-4-4/ IEC 61000-4-4 Criterion B Remote bus: 2 kV Power supply: 2 kV I/O cables: 2 kV Criterion A All interfaces: 1 kV Surge voltage EN 61000-4-5 IEC 61000-4-5 Criterion B DC supply lines: ± 0.5 kV/± 1.0 kV (symmetrical/asymmetrical) Signal lines: ± 0.5 kV/± 0.5 kV (symmetrical/asymmetrical) Conducted interference EN 61000-4-6 IEC 61000-4-6 Criterion A Test voltage 10 V Noise Emission Test According to EN 61000-6-4 Noise emission of housing EN 55022 Class B (residential) Interface: INTERBUS Incoming remote bus Copper cable (RS-422), c onnected via 9-pos. D-SUB connector; supply electrically isolated; shielding connected with a capacitor to functional earth ground Outgoing remote bus Copper cable (RS-422), connected via 9-pos. D-SUB connector; supply electrically isolated; shielding directly connected to functional earth ground Recommended cable lengths See INTERBUS system data in the IBS SYS INTRO G4 UM E user manual
I L BI B2 4D I 1 6 - D S U B 7118_en_02 PHOENIX CONTACT 5
24 V Module Supply (Communications Power and Sensor Supply; UL and US)
Tolerance -15%/+20% according to EN 61131-2 Ripple ±5% according to EN 61131-2 Permissible range 19.2 V DC to 30.0 V DC Current consumption at UL 60 mA Current consumption at US 4 A Safety equipment for communications power Surge pr otection and protection against polarity reversal Safety equipment for sensor supply Surge, overload and short-circuit protection Connection Via MINI-COMBICON connector Digital Inputs Number 16 Connection method for sensors 2 and 3-wire technology Input design According to EN 61131-2 Type 1 Definition of switching thresholds Maximum low-level voltage U Lmax < 5 V Minimum high-level voltage UHmin > 15 V Common potentials Sensor supply U S, ground Nominal input voltage UIN 24 V DC Permissible range -30 V < U IN < +30 V DC Nominal input current for UIN 5 mA, typical Current flow Linear in the range 1 V < U IN < 30 V Delay time ≤ 500 µs Permissible cable length to the sensor 100 m Use of AC sensors AC sensors in the voltage range < UIN are limited in application Power Dissipation Formula to Calculate the Power Dissipation of the Electronics Where PTOT Total power dissipation of the module IS Current from the sensor supply i Continuous index n Number of set inputs (n = 1 to 16) P = 1.44 W + 0.12 WTOT /c83+ I x 0.06 WS i=1 n Limitation of Simultaneity, Derating No limitation of simultaneity, no derating Approvals For the latest approvals, please visit www.download.phoenixcontact.com.
I L BI B2 4D I 1 6 - D S U B 7118_en_02 PHOENIX CONTACT 7 Connecting INTERBUS, the Supply, and Sensors Figure 4 Terminal point assignment of the connectors Terminal Point Assignment of the MINI-COMBICON Connectors for the Connection of the Supply Voltages (Connectors X1 and X2 in Figure 4 on page 7). /G37 /G31 /G31 /G38 /G43 /G30 /G30 /G36 /G35 /G2D /G38 /G31 /G2E /G31 /G32 /G2E /G31 /G31 /G2E /G32 /G32 /G2E /G32 /G31 /G2E /G33 /G32 /G2E /G33 /G31 /G2E /G34 /G32 /G2E /G34 /G31 /G2E /G35 /G32 /G2E /G35 /G31 /G2E /G36 /G32 /G2E /G36 /G31 /G32 /G31 /G2E /G31 /G31 /G2E /G32 /G32 /G2E /G31 /G32 /G2E /G32 /G31 /G2E /G33 /G32 /G2E /G33 /G31 /G2E /G34 /G32 /G2E /G34 /G31 /G2E /G35 /G32 /G2E /G35 /G31 /G2E /G36 /G32 /G2E /G36 /G49 /G4C /G42 /G20 /G49 /G42 /G20 /G32 /G34 /G20 /G44 /G49 /G31 /G36 /G20 /G2D /G44 /G53 /G55 /G42 /G20 /G20 /G20 /G20 /G64 /G65 /G72 /G2D /G4E /G6F /G2E /G3A /G20 /G32 /G38 /G37 /G38 /G34 /G52 /G45 /G4D /G4F /G54 /G45 /G20 /G49 /G4E /G52 /G45 /G4D /G4F /G54 /G45 /G20 /G4F /G55 /G54 /G58 /G33 /G58 /G34 /G31 /G2E /G31 /G55 /G4C /G55 /G53 /G4E /G43 /G4E /G43 /G30 /G56 /G30 /G56 /G4E /G43 /G4E /G43 /G46 /G45 /G58 /G31 /G58 /G32 Terminal Point Assignment UL 24 V communications power U L US 24 V sensor supply U S NC Not used NC Not used Terminal Point Assignment 0V GND 0V GND NC Not used NC Not used FE Functional earth ground The terminal points for GND (0V) can have a total current of 8 A per terminal point. The maximum current carrying capacity of 8 A must not be exceeded. The supply points have the same ground potential. All ground supplies on a module are electrically connected with one another. The communications power is also electrically connected via all contacts. In this way it can supply all potentials with just one supply without the need for additional terminals, see "Connection example" on page 9.
I L BI B2 4D I 1 6 - D S U B 7118_en_02 PHOENIX CONTACT 8 Terminal Point Assignment of the INTERBUS Connectors (Connectors X 3 and X4 in Figure 4 on page 7) Figure 5 Assignment of the remote bus interfaces (D- SUB connector) A Remote OUT (outgoing remote bus) B Remote IN (incoming remote bus) Terminal Point Assignment of the Input Connectors (Connectors 5 to 8 in Figure 4 on page 7) /G42 /G41 /G44 /G49 /G47 /G4E /G44 /G35 /G39 /G34 /G38 /G44 /G4F /G6E /G6F /G74 /G20 /G63 /G6F /G6E /G6E /G2E /G36 /G31 /G37 /G32 /G33 /G44 /G4F /G44 /G4F /G44 /G49 /G44 /G49 /G36 /G31 /G37 /G32 /G33 /G35 /G39 /G34 /G38 /G44 /G49 /G44 /G4F /G72 /G65 /G73 /G65 /G72 /G76 /G65 /G64 /G47 /G4E /G44 /G31 /G35 /G39 /G36 /G31 /G35 /G36 /G39 /G72 /G65 /G73 /G65 /G72 /G76 /G65 /G64 /G6E /G6F /G74 /G20 /G63 /G6F /G6E /G6E /G2E /G72 /G65 /G73 /G65 /G72 /G76 /G65 /G64 /G72 /G65 /G73 /G65 /G72 /G76 /G65 /G64 /G72 /G65 /G73 /G65 /G72 /G76 /G65 /G64 /G72 /G65 /G73 /G65 /G72 /G76 /G65 /G64 /G37 /G31 /G31 /G37 /G42 /G30 /G31 /G32 Assignment Remark/Wire Color in the INTERBUS Standard Cable DO Receive Green DO Receive Yellow DI Transmit Pink DI Transmit Gray GND Reference potential Brown Shield (incoming remote bus) Shield potential is connected with a capacitor to functional earth ground (FE) of the potential jumper. Shield (outgoing remote bus) Shield potential is directly connected to functional earth ground (FE) of the potential jumper. In order to assemble the connectors, proceed as described in the IBS SYS PRO INST UM E user manual. Terminal Point Assignment Connector 5 (I1) Connector 6 (I2) Connector 7 (I3) Connector 8 (I4)
I L BI B2 4D I 1 6 - D S U B 7118_en_02 PHOENIX CONTACT 9 Connection Example Figure 6 Connection example The numbers above the module illustration identify the connector slots. When connecting the sensors observe the assignment of the terminal points to the process data (see "Process Data" on page 10). The module has an FE spring (metal clip) on the bottom of the electronics base. This spring creates an electrical connection to the DIN rail. Use grounding terminals to connect the DIN rail to protective earth ground. The module is grounded when it is snapped onto the DIN rail. To ensure reliable functional earth grounding of the module even when the DIN rail is dirty or the metal clip is damaged, Phoenix Contact also recommends grounding the module via one of the FE terminal points. /G2B /G32 /G34 /G20 /G56 /G49 /G4E /G20 /G31 /G35 /G2B /G32 /G34 /G20 /G56 /G49 /G4E /G20 /G31 /G34 /G37 /G31 /G31 /G38 /G41 /G30 /G31 /G30 /G55 /G53 /G2B /G46 /G45 /G55 /G4C /G35 /G36 /G37 /G38
I L BI B2 4D I 1 6 - D S U B 7118_en_02 10PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany www.phoenixcontact.com Programming Data Process Data Assignment of the Terminal Points to the IN Process Data Word (Slots 5 to 8) Diagnostics Error Table With Diagnostic Data and Status Indicators © PHOENIX CONTACT 03/2007 ID code 02 hex (02dec) Length code 01 hex Process data channel 16 bits Input address area 1 word Output address area 0 words Parameter channel (PCP) 0 words Register length (bus) 1 word For the assignment of the illustrated (byte.bit) view to your control or computer system, please refer to the DB GB IBS SYS ADDRESS data sheet. Please refer to the application note for addressing 16-channel ILB modules. The documentation can be downloaded at www.download.phoenixcontact.com. (Word.bit) view Word Word 0 B i t 1 5 1 4 1 3 1 2 1 1 1 0 9876543210 (Byte.bit) view Byte Byte 0 Byte 1 B i t 7654321076543210 Module Slot 6 (I2) 5 (I1) 8 (I4) 7 (I3) Status indicator Slot 6 5 8 7 L E D 4321432143214321 Error Type Diagnostic Data Status Indicators Sensor voltage US too low I/O error message US LED is OFF E (PWR) LED is red Sensor supply short circuit I/O error message E (IN) LED of the sensor supply is red