Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.gr ayhill.com I/O Modules AC Output Modules

FEATURES

 Transient Protection: Meets the requirements of IEEE 472, “Surge Withstanding Capability Test”  SPST, Normally Open  Zero Crossing Turn-On  UL, CSA, CE, TÜV Certified  Optical Isolation  OpenLine ® and G5 Modules Provide Replaceable 5x20 mm Glass Fuses  Built-in Status LED  Lifetime Warranty Maximum Current Versus Ambient Temperature The chart indicates continuous current to limit the junction temperatures to 100°C. Information is based on steady state heat transfer in a 2 cubic foot sealed enclosure. Figure 1 DIMENSIONS For complete dimensional drawings, see pages L-4 or L-5. FUSES G5 Fuses are 5 Amp Littelfuse part number 217005 or equivalent. OpenLine ® fuses are 3.15 Amp Littelfuse part number 2173.15. CIRCUITRY 70L-OAC 70G-OAC 70-OAC 70M-OAC AMBIENT TEMPERATURE (˚C) LOAD CURRENT (AMPS) STANDARD, G5 PACKAGES MINIATURE PACKAGE OPENLINE PACKAGE/CH Package Style Std (70-) Mini (70M-) G5 (70G-) OL (70L-) Specifications Units Maximum 1 Cycle Surge 2 A rms 80 80 80 30 Maximum Turn-On-Time (60 Hz) 3 mSec 8.33 8.33 8.33 8.33 Maximum Turn-Off Time (60 Hz) mSec 8.33 8.33 8.33 8.33 Static dv/dt 7 V/µsec 3000 3000 3000 3000 Isolation Voltage

4 V rms 4000 4000 4000 2500

Vibration5 MIL-STD-202 MIL-STD-202 MIL-STD-202 IEC68-2-6 Mechanical Shock 6 MIL-STD-202 MIL-STD-202 MIL-STD-202 IEC68-2-27 Storage Temp. Range °C -40 to 125 -40 to 125 -40 to 125 -40 to 100 Operating Temp. Range °C -40 to 100 -40 to 100 -40 to 100 -40 to 85 Warranty Lifetime Lifetime Lifetime Lifetime 1 See Figure 1 for derating. 2 Maximum 10 cycle surge is 50% of 1 cycle surge. Application of maximum surge may not be repeated until module temperature has r eturned to its steady state value. 3 Except 70-OAC5A5 which is 200 µSec and 70-OAC5A-11, 70M-OAC5A-11, and 70G-OAC5A-11 which are 100 µSec. 4 Field to logic and channel-to-channel if Grayhill racks are used. 5 MIL-STD-202, Method 204, 20 , 10-2000 Hz or IEC68-2-6, 0.15 mm/sec 2, 10-150 Hz. 6 MIL-STD-202, Method 213, Condition F, 1500G or IEC68-2-27, 11 mS, 15g. 7 Except part numbers with -L suffix which have a dv/dt rating of 200 V/µSec. SPECIFICATIONS: By Package Style Standard, Mini, G5 OpenLine ® Rx VAC DC CONTROL TRIGGER CIRCUIT SNUBBER LOAD LOAD Fuse and status LED in G5 and OpenLine modules only. TYPICAL WIRING FOR MODULE 0 2.15K MODULE OPTICAL ISOLATION OPTICAL ISOLATION SNUBBER SNUBBER CHANNEL A CHANNEL B B A RACK OR BASE LOAD LOAD TERMINAL BLOCK # I/O MODULE PIN # GND Vcc CH. A CONTROL CH. B CONTROL MODULE ID I/O

Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.gr ayhill.com AC Output Modules Miniature, Normally Open, Random Turn-on 70M-OAC5A-11 Miniature, Normally Open, Zero Voltage Turn-on (ZVT) 70M-OAC5 70M-OAC5A 70M-OAC15 70M-OAC15A 70M-OAC24 70M-OAC24A Miniature, Normally Open, ZVT, Inductive Load 70M- OAC5-L 70M-OAC5A-L Standard, Normally Closed, Random Turn-on 70-OAC5A5 Standard, Normally Open, Random Turn-on 70-OAC5A-11 70-OAC24A-11 Standard, Normally Open, ZVT 70-OAC5 70-OAC5A 70-OAC15 70-OAC15A 70-OAC24 70-OAC24A Standard, Normally Open, ZVT, Inductive Load 70- OAC5-L 70-OAC5A-L Specifications Units Nominal Line Voltage Vac 120 240 120 240 120 240 Load Voltage Range Vac 24-140 24-280 24-140 24-280 24-140 24-280 Minimum Peak Blocking Voltage Volts 400 600 400 600 400 600 Maximum Off-state Leakage @ 60Hz mA, rms 2 4 2 4 2 4 Nominal Logic Voltage (Vcc) Vdc 5 5 15 15 24 24 Logic Voltage Range Vdc 2.5-10 2.5-10 10-18 10-18 15-30 15-30 Max. Logic Supply Current @ Nominal Vcc mA 16 16 9 9 9 9 Nominal Input Resistance (Rx) Ω 240 240 1800 1800 2700 2700 Minimum Drop Out Voltage Vdc 1 1 1 1 1 1 Maximum Reverse Logic Voltage Vdc -5 -5 -5 -5 -5 -5 Type/Function Grayhill Part Number Standard and Miniature Modules SPECIFICATIONS: By Part Number G5 Modules Grayhill Part Number 70G-OAC5 70G-OAC5A 70G-OAC15 70G-OAC15A 70G-OAC24 70G-OAC24A 70G-OAC5-L 70G-OAC5A-L 70G-OAC15-L 70G-OAC15A-L70G-OAC24-L 70G-OAC24A-L 70G-OAC5A-11 Nominal Line Voltage Vac 120 240 120 240 120 240 Load Voltage Range Vac 24-140 24-280 24-140 24-280 24-140 24-280 Minimum Peak Blocking Voltage Volts 400 600 400 600 400 600 Maximum Off-state Leakage @ 60Hz mA, rms 2 4 2 4 2 4 Nominal Logic Voltage (Vcc) Vdc 5 5 15 15 24 24 Logic Voltage Range Vdc 4-6 4-6 8-20 8-20 18-32 18-32 Max. Logic Supply Current @ Nominal Vcc mA 20 20 12 12 8 8 Nominal Input Resistance (Rx) W 100 100 1000 1000 2700 2700 Minimum Drop Out Voltage Vdc 1 1 1 1 1 1 Maximum Reverse Logic Voltage Vdc -5 -5 -5 -5 -5 -5 OpenLine® Modules Type/Function Grayhill Part Number Dual, Fusible, Normally Open, ZVT 70L-OAC 70L-OACA Dual, Fusible, Normally Open, ZVT, Inductive Load 70L-OAC-L 70L-OACA-L Specifications Units Nominal Line Voltage Vac 120 240 Load Voltage Range Vac 24-140 24-280 Minimum Peak Blocking Voltage Volts 600 600 Maximum Off-State Leakage @ 60 Hz mA, rms 2 4 Nominal Logic Voltage Vdc 5 5 Logic Voltage Range Vdc 4.5-28 4.5-28 Max. Logic Supply Current @ Nominal Vcc mA 7/CH 7/CH Module ID Resistance to Logic Ground Ω 2.15K 2.15K Minimum Drop Out Voltage Vdc 1 1 Available from your local Grayhill Distributor. For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill. Type/Function G5 Fusible, Normally Open, ZVT G5 Fusible, Normally Open, ZVT, Inductive Load G5 Fusible, Normally Open, Random Turn-on Specifications Units I/O