70RCK16 GRAYHILL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.gra yhill.com System 50 System 50 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Y B W R AC INPUT AC OUTPUT DC INPUT DC OUTPUT 14.05 (356,9) 13.55 (344,2) 0.40 (10,2)
50 PIN EDGE CARD OR HEADER
CONNECTOR FOR LOGIC SIGNALS (SEE NOTES) LOGIC SUPPLY TERMINAL STRIP FIELD WIRING TERMINAL STRIP 5 A FUSE 0.45 (11,4) 2.60 (66,0) KEY SLOT PINS PIN 1 USER INSTALLABLE JUMPER FOR +VCC (2 PLACES) STATUS LED STANDOFF I.D. 0.15 (3,8) DIA. (4 PLACES) CLEARANCE FOR #6 SCREWS 2.20 (55,9) MAX. 3.00 (76,2) 3.50 (88,9) 0.25 (6,4) 0.25 (6,4) 0.75 (19,1) NOTE: MAXIMUM TERMINAL SCREW TORQUE NOT TO EXCEED 5 IN-LBS.
16 CHANNEL RACK: Standard
Part No. 70RCK16 Dimensions are shown in inches (and millimeters). All tolerances are ± 0.010 (0,25) unless otherwise specified. RACKS
16 Channel
FEATURES
For use with System 50 Style Controllers Available for Standard, Miniature, G5 and OpenLine ® Modules Panel and DIN Rail Mount Versions UL, CSA Certified System 50
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.gra yhill.com System 50 System 50
16 CHANNEL RACK: Miniature
16 CHANNEL RACK: G5
012 3 45 67 8 9 1 01 11 21 3 14 15 Y B W R AC INPUT AC OUTPUT DC INPUT DC OUTPUT 10.00 (254,0) 9.35 (237,5) LOGIC SUPPLY TERMINAL STRIP FIELD WIRING TERMINAL STRIP STANDOFF I.D 0.15 (3,8) DIA. (4 PLACES) CLEARANCE FOR #6 SCR E STATUS LED 0.40 (10,2) .45 1,4) 0.25 (6,4) .60 6,0) 3.50 (88,9)3.00 (76,2) 2.20 (55,9) MAX. 0.75 (19,1) 5A FUSE MODULE HOLD DOWN STRIP WITH THUMB SCREWS CARD EDGE OR HEADER CONNECTOR FOR LOGIC SIGNALS (SEE NOTES) USER INSTALLABLE JUMPER FOR +VCC (2 PLACES) PIN 1 KEY SLOT PINS 11/13 0.2 (5,1) NOTE: MAXIMUM TERMINAL SCREW TORQUE NOT TO EXCEED 5 IN-LBS. Part No. 70MRCK16 Dimensions are shown in inches (and millimeters). All tolerances are ± 0.010 (0,25) unless otherwise specified. Part No. 70GRCK16 Dimensions are shown in inches (and millimeters). All tolerances are ± 0.010 (0,25) unless otherwise specified. 012 3 45 67 8 9 1 01 11 21 3 14 15 10.00 (254,0) 9.125 (231,8) LOGIC SUPPLY TERMINAL STRIP FIELD WIRING TERMINAL STRIP STANDOFF I.D. 0.15 (3,8) DIA. (4 PLACES) CLEARANCE FOR #6 SCREW STATUS LED ON THE MODULE 0.25 (6,4) 3.25 (82,6)2.75 (69,9) 3.39 (86,1) MAX. 0.75 (19,1) PIN 1 0.2 (5,1) 1 3 579 1 1 1 3 15 17 19 21 2 3 25 27 29 31246 8 10 12 14 16 1 8 20 22 24 26 2 83 0 32 .093 (2,36) REF. NOTE: MAXIMUM TERMINAL SCREW TORQUE NOT TO EXCEED 5 IN-LBS.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.gra yhill.com System 50 System 50
16 CHANNEL RACK: G5 Control and Field Connection Terminal Blocks
Part No. 70GRCK16T Dimensions are shown in inches (and millimeters). All tolerances are ± 0.010 (0,25) unless otherwise specified.
16 CHANNEL RACK: G5 Channel-to-Channel Isolation
Part No. 70GRCK16I and 70GRCK16I-DIN Dimensions are shown in inches (and millimeters). All tolerances are ± 0.010 (0,25) unless otherwise specified. System 50 1.687 (42,85) 3.392 (86,16) REF. .750 (19,05) REF.
2 POSITION
HOLE .15 (3,81) DIA. (4 PLACES) (CLEARANCE FOR #6 SCREW) RES. 3.3 KΩ/.25W (2 PLACES) KNURL FASTENER (16 PLACES) 32 POS. TERMINAL STRIP FOR CONTROL LOGIC STRIP 9.500 (241,3) 9.000 (228,6)
32 POSITION TERMINAL STRIP
2.750 (69,85) 3.250 (82,55) .250 (6,35) .250 (6,35) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 +VCC – CONTROL FIELD 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 NOTE: MAXIMUM TERMINAL SCREW TORQUE NOT TO EXCEED 5 IN-LBS. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 GND 2.125 (53,98) 4.00 (101,6) REF. DIN CARRIER PANEL MOUNT 4.270 ± .010 (108,46 ± 0,25) DIN CARRIER 4.800 ± .020 (121,92 ± 0,51) RES. 3.3 KΩ/.25W (16 PLACES) KNURL FASTENER (16 PLACES) 32 POS. TERMINAL STRIP FOR CONTROL LOGIC STRIP CONTROL FIELD 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 3.500 ± .010 (88,9 ± 0,25) NOTE: MAXIMUM TERMINAL SCREW TORQUE NOT TO EXCEED 5 IN-LBS.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.gra yhill.com System 50 System 50
16 CHANNEL RACK: OpenLine® for System 50
Part No. 70LRCK16-HL Dimensions are shown in inches (and millimeters). All tolerances are ± 0.010 (0,25) unless otherwise specified.
16 CHANNEL RACK: OpenLine® w/ DIN Rail Mount for System 50
Part No. 70LRCK16-DIN Dimensions are shown in inches (and millimeters). All tolerances are ± 0.010 (0,25) unless otherwise specified. System 50 3.4 (85.93) MAX.75 (19.05) REF .24 (6.05) 4.3 (108.46) 3.8 (96.52) .25 5.5 (139.70) REMOVABLE JUMPER CONNNECTS GND TO PLATED HOLE FOR GROUNDING FIELD WIRING TERMINAL STRIP STANDOFF I.D. 0.15 (3.81) DIA. (4 PLACES) CLEARANCE FOR #6 SCREW PIN 1 5A FUSE 50-PIN STRAIGHT HEADER CONNECTOR LOGIC SUPPLY TERMINAL STRIP TOP ROW: + LOGIC SUPPLY BOTTOM ROW: GND M7M6M5M4 BA M3M2M1M0 502 14 9 1816 31+5 +5 NOTE: MAXIMUM TERMINAL SCREW TORQUE NOT TO EXCEED 5 IN-LBS. 3.8 (95.81) REF 2.2 (56.49) DIN CARRIER 4.7 (119.13) PCB 4.3 (108.46) PCB 5.5 (139.70) DIN CARRIER 5.7 (143.76) REMOVABLE JUMPER CONNNECTS GND TO PLATED HOLE FOR GROUNDING LOGIC SUPPLY TERMINAL STRIP TOP ROW: + LOGIC SUPPLY BOTTOM ROW: GND FIELD WIRING TERMINAL STRIP PIN 1 5A FUSE 50-PIN STRAIGHT HEADER CONNECTOR +5 +5 M7M6M5M4 BA M3M2M1M0 502 14 9 1816 NOTE: MAXIMUM TERMINAL SCREW TORQUE NOT TO EXCEED 5 IN-LBS.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.gra yhill.com System 50 System 50 SCHEMATIC: Part No. 70GRCK16 SCHEMATIC: Part No. 70GRCK16T SCHEMATIC: Part Nos. 70GRCK16I AND 70GRCK16I-DIN System 50 123456789 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 5N/C N/C N/C N/C N/C N/C N/C 3.3K
50 PIN HEADER
1 A FUSE
3.3 KΩ +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC +VCC LOGIC GND 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.gra yhill.com System 50 System 50 SCHEMATIC: Part Nos. 70RCK16 and 70MRCK16 SCHEMATIC: Part No. 70LRCK16-HL, -DIN System 50 N/C N/C N/C N/C N/C N/C N/C N/C12 910 1112 3230 2927 2826 2523 2422 2119 2018 1715 1614 1311 1210 FIELD WIRING TERMINAL STRIP MODULE LOCATION M0 M1 M2 M3 M4 M5 M6 M7 LOGIC SUPPLY TERMINAL STRIP 123456789 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2– 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 5N/C N/C N/C N/C N/C N/C N/C 3.3K50 PIN EDGE OR HEADER CONNECTOR FOR LOGIC SIGNALS LOGIC SUPPLY TERMINAL STRIP USER INSTALLABLE JUMPER FOR +VCC (2 PLACES) FIELD WIRING TERMINAL STRIP 5A FUSE MODULE POSITION
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.gra yhill.com System 50 System 50 Part Number I/O Description UL CSA Style 70RCK16 16 Card edge X X Standard 70RCK16-HL 16 50-pin header with ejector levers X X Standard 70MRCK16-EC 16 Card edge X X Mini 70MRCK16-HL 16 50-pin header with ejector levers X X Mini 70GRCK16-HL 16 50-pin header with ejector levers X X G5 70LRCK16-HL 16 50-pin header with ejector levers X X OpenLine ® 70LRCK16-DIN 16 50-pin header with DIN rail mnt. X X OpenLine ® 70GRCK16I 16 Positive or negative true logic* –Panel Mount X X G 5 70GRCK16I-DIN 16 Positive or negative true logic* –DIN rail mount X X G 5 70GRCK16T 16 Negative true logic*– Panel Mount X X G 5 * Positive true logic applies to output modules only. ORDERING INFORMATION(modules ordered separately) Available from your local Grayhill Distributor. For prices and discounts, contact a local Sales Office, an authorized local Distributor, or Grayhill. System 50