70L-ODC5R_10 GRAYHILL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com I/O Modules Dry Contact and Mechanical Relay Output Modules 70L-ODC5R 70G-ODCR/OACRL Y 70-ODCR/OACRL Y 70M-ODCR Package Style Std (70-) Mini (70M-) G5 (70G-) OpenLine® (70L-) Specifications Units Isolation Voltage1 Vrms 1500 1500 1500 1500 Vibration2 MIL-STD-202 MIL-STD-202 MIL-STD-202 IEC68-2-6 Mechanical Shock3 MIL-STD-202 MIL-STD-202 MIL-STD-202 IEC68-2-7 Storage Temp. Range °C -40 to 70 -40 to 70 -40 to 70 -40 to 70 Operating Temp. Range °C -40 to 70 -40 to 70 -40 to 70 -40 to 70 1 Field to logic and channel-to-channel if Grayhill racks are used. 2 MIL-STD-202, Method 204, 20 G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec2, 10-150 Hz. 3 MIL-STD-202, Method 213, Condition F , 1500 G or IEC68-2-27, 11 mS, 15g. SPECIFICATIONS By PACkAGE STyLE CIrCUITry Standard, Mini, G5 OpenLine® VAC/VDC +VCC INPUT GROUND AMP LOAD LOAD Fuse and status LED in G5 modules only. AMP AMP
FEATUrES
- SPST, Normally Open
- UL, CSA Certified
- 1500 Vac Isolation
- G5 and OpenLine® Modules Provide Replaceable 5x20mm Glass Fuse
- Built-in Status LED
- Lifetime Warranty
- Switch AC or DC with the Same Module
- Very Low Off-State Leakage Current for AC loads
- No Off-State Leakage Current for DC loads
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Dry Contact and Mechanical Relay Output Modules Type/Function Grayhill Part Number Miniature, Normally Open 70M-ODC5r 70M-ODC24r Standard, Normally Open 70-ODC5r 70-OAC5rLy 70-ODC24r Specifications Units Maximum Line Voltage Vdc/Vac 100/120 110/250 100/120 Load Voltage Range Vdc/Vac 0-100/0-120 0-110/0-250 0-100/0-120 Maximum Contact Rating W 10 90 10 Maximum Switching Current1 A 0.5 3.0 0.5 Maximum Carry Current1 A 1.0 5.0 1.0 Minimum Life Expectancy @ 10 Vdc/10 mA Cycles 200 x 106 — 200 x 106 @ 48 Vdc/100 mA Cycles 500 x 103 — 500 x 103 @ 120 Vac/80 mA Cycles 500 x 103 — 500 x 103 @ 30 Vdc or 230 Vac/3A Cycles — 100 x 103 — Maximum Contact Resistance3 mW 250 250 250 Maximum Off-State Leakage mA .002 .002 .002 Maximum Turn-On Time2 mSec 1 11 1 Maximum Turn-Off Time2 mSec 1 11 1 Nominal Logic Voltage (Vcc) Vdc 5 5 24 Logic Voltage Range Vdc 4.8-6.0 4.8-6.0 20-30 Maximum Logic Supply Current @ Nominal Vcc mA 10 30 20 Nominal Input Resistance (Rx) W 500 200 1700 Minimum Drop-Out Voltage Vdc 2.5 4.8 23 Maximum Reverse Logic Voltage Vdc -5 -5 -5 Standard and Miniature Modules SPECIFICATIONS By PArT NUMBEr (all specs at 25oC unless noted otherwise) G5 and OpenLine® Modules Type/Function Grayhill Part Number G5 Fusible, Normally Open 70L-ODC5r 70G-ODC5r 70G-OAC5rLy 70G-ODC24r Specifications Units Maximum Line Voltage Vdc/Vac 200/200 100/120 110/250 100/120 Load Voltage Range Vdc/Vac 0-200/0-200 0-100/0-120 0-110/0-250 0-100/0-120 Maximum Contact Rating W 10 10 90 10 Maximum Switching Current1 A 0.5 0.5 3.0 0.5 Maximum Carry Current1 A 1.5 1.0 5.0 1.0 Minimum Life Expectancy @ 1Vdc/10 mA Cycles 1000 x 106 — — — @ 10 Vdc/10 mA Cycles — 200 x 106 — 200 x 106 @ 48 Vdc/100 mA Cycles — 500 x 103 — 500 x 103 @ 120 Vac/80 mA Cycles 500 x 103 500 x 103 — 500 x 103 @ 30 Vdc or 230 Vac/3A Cycles — 100 x 103 — Maximum Contact Resistance3 mW 300 250 250 250 Maximum Turn-On Time2 mSec 1 1 11 1 Maximum Turn-Off Time2 mSec 1 1 11 1 Nominal Logic Voltage (Vcc) Vdc 5 5 5 24 Max. Logic Supply Current @ Nominal Vcc mA 30 max./channel 10 30 30 Nominal Input Resistance (Rx) W 167 500 200 1200 Minimum Drop-Out Voltage Vdc 4.5 1 1 23
1 Inductive loads require diode suppression or RC network
2 Times include debounce
3 Initial value
Available from your local Grayhill Distributor. For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill.