7018FX2 Industrial Ethernet Switch N-Tron Networking Series Managed Industrial Ethernet Switch The N-TRON® 7018FX2 gigabit capable Industrial Ethernet Switch offers outstanding performance and ease of use. It is ideally suited for connecting Ethernet enabled industrial and/or security equipment and is a fully managed switch. PRODUCT FEATURES
- Fourteen 10/100BaseTX RJ-45 Ports
- Two 100BaseFX Ports, ST or SC Style
- Two Optional SFP (Mini-GBIC) Gigabit Transceivers
- 1000BaseSX/LX Fiber with LC style connectors or
- 1000BaseT Copper with RJ-45 connectors
- -40 oC to 70oC Operating temperature
- ESD and Surge Protection Diodes on all Ports
- Auto Sensing 10/100BaseTX, Duplex, and MDIX
- Redundant Power Inputs (10-30VDC)
- Confi gurable Alarm Contact & Bi-Color Fault Status LED Fully Managed Features:
- SNMP v1, v2, v3 and Web Browser Management
- Detailed Ring Map and Fault Location Charting
- N-Ring ™ Technology with ~30ms Healing
- N-View ™ OPC Monitoring
- N-Link ™ Redundant N-Ring Coupling
- Plug-and-play IGMP Support
- 802.1Q tag VLAN and Port VLAN
- 802.1p QoS and Port QoS
- EtherNet/IP™ CIP Messaging
- LLDP (Link Layer Discovery Protocol)
- Port Trunking
- Port Mirroring
- 802.1d, 802.1w, 802.1D RSTP
- DHCP Server, Option 82 relay, Option 61, IP Fallback
- Port Security—MAC Address Based Management Features The 7018FX2 offers several management functions that can be easily confi gured using a web browser. IGMP Snooping - Internet Group Management Protocol allows the 7018FX2 switch to forward and fi lter multicast traffi c intelligently. VLAN - Virtual Local Area Network allows you to segment the switch in order to create two or more separate local area network domains. QoS - Quality of Service provides prioritization of network traf fi c in order to provide better network service. QoS improves the latency of prioritized Ethernet packets required for ring management, real-time, and other interactive applications. Port Trunking - Trunking (link aggregation) enables multiple physical ports to be linked together and function as one uplink to another N-TRON trunking capable switch con fi gured in the same manner, thereby increasing the bandwidth between switches. This confi guration can provide increased bandwidth and redundancy to applications requiring high levels of fault tolerant operation. Port Mirroring - Allows the traffi c on one port to be duplicated and sent to a designated mirror port. Port mirroring is used to monitor Ethernet traffi c on the designated source port using the assigned mirror port. DHCP-DHCP Server / Client automates the assignment of IP addresses. DHCP Option 82 assures that if a device on a specifi c port is replaced, the replacement receives the same IP address as the original device. Shown with Optional Gigabit SFP Transceivers installed Rapid Spanning Tree Protocol RSTP allows the switch to be con fi gured in a ring or mesh topology, and provides support for redundant path communications with high speed (rapid) healing. Remote Monitoring Options For ease of confi guration and monitoring, the 7018FX2 offers web browser management and N-View OLE for process control (OPC) server software. The N-TRON N-View software can be combined with popular HMI software packages to add network traf fi c monitoring, trending, and alarming to any application using N-TRON switches In addition, SNMP is available for switch link and status monitoring. The alarm contact and status LED can be confi gured to respond to power failure on power input 1 or input 2, N-Ring broken, partial break high, partial break low, or if multiple ring managers are detected. N-Ring Technology N-TRON's 7018FX2ring manager using N-TRON's N-Ring technology offers expanded ring size capacity, detailed fault diagnostics, and a standard healing time of ~30ms. The 7018FX2 ring manager periodically checks the health of the ring via packets. If the ring manager stops receiving these health check packets, it converts the ring to a linear topology within ~30ms. When all switches in the ring are N-TRON fully managed switches, a detailed ring map and fault location chart will also be provided on the ring manager’s web browser and OPC server to identfy the health status of the ring. N-Link™ allows the linking of two N-Rings. Up to 250 fully managed N-TRON switches can participate in N-Ring topologies. Industrial Packaging and Specifi cations The 7018FX2 is designed to operate in industrial environments. It is housed in a rugged steel DIN-Rail enclosure. It has extended industrial specifi cations and features to meet or exceed the operating parameters of connected equipment. These include extended temperature ratings, extended shock and vibration specs, redundant power inputs, and high MTBF (greater than 2M hours). Ease of Use The 10/100BaseTX ports are auto sensing and auto configuring. Each copper port is automatically negotiated for maximum speed and performance by default, but can also be hard coded through the user interface. The two optional gigabit ports support full 2000 Mb/s communications via 1000BaseSX/LX/T. For added fl exibility, these SFP (Mini-GBIC) gigabit transceivers are fi eld upgradable or can be factory installed at the time of purchase. THE INDUSTRIAL NETWORK COMPANY
7018FX2 Specifi cations Switch Properties Number of MAC Addresses: 8000 Aging Time: Programmable Latency Typical: 2.6 μs Switching Method : Store-and-Forward Case Dimensions Height: 2.3" (5.8 cm) Width: 8.3" (21.0 cm) Depth: 4.8" (12.1 cm) Weight (max): 3.3 lbs (1.5 kg) DIN-Rail Mount: 35mm Electrical Redundant Input Voltage: 10-30 VDC (Regulated) Input Current (max): 520mA max. @24V BTU/hr: 42.6@24VDC N-TRON Power Supply: NTPS-24-1.3 (1.3 A@24V) Environmental Operating Temperature: -40oC to 70oC Storage Temperature: -40oC to 85oC Operating Humidity: 5% to 95% (Non Condensing) Operating Altitude: 0 to 10,000 ft. Shock and Vibration (bulkhead mounted) Shock: 200g @ 10ms Vibration/Seismic: 50g, 5-200Hz, Triaxial Reliability MTBF: >2 Million Hours Network Media 10BaseT: >Cat3 Cable 100BaseTX: >Cat5 Cable 1000BaseT: >Cat5e Cable 100BaseFX, 1000BaseSX Multimode: 50-62.5/125 μm 100BaseFXE, 1000BaseLX Singlemode: 7-10/125μm THE INDUSTRIAL NETWORK COMPANY Connectors 10/100BaseTX: Fourteen (14) RJ-45 Copper Ports 100BaseFX: Two (2) SC or ST Fiber Duplex Ports 1000BaseT: Up to Two (2) RJ-45 Gigabit Copper Ports (optional) 1000BaseSX: Up to Two (2) LC Duplex Gigabit Fiber Ports (optional) Recommended Wiring Clearance Front: 4" (10.16 cm) Side: 1" (2.54 cm) Regulatory Approvals FCC Title 47, Part 15, Subpart B - Class A; ICES-003 - Class A UL Listed (US and Canada) 1604; ANSI/ISA-12.12.01-2007 Class I, Div 2, Groups A, B, C, D, and T4A CE: EN61000-6-2:2001: EN61000-4-2, 3, 4, 5, 6 EN55022:1998+A1:1999+A2:2002-Class A EN50155 for Railway Applications GOST-R Certi ed, RoHS Compliant Designed to comply with: IEEE 1613 for Electric Utility Substations NEMA TS1/ TS2 for Traf c control Fiber Transceiver Characteristics Fiber Length 2km* 15km 40km 80km** TX Power Min -19dBm -15dBm -5dBm -5dBm RX Sensitivity Max -31dBm -31dBm -34dBm -34dBm Wavelength 1310nm 1310nm 1310nm 1550nm * Multimode Fiber Optic Cable ** Singlemode Fiber Optic Cable Fiber Length 550m for 50/125μm 275m for 62.5/125μm* 10km 40km 80km ** TX Power Min -9.5dBm -9.5dBm -2dBm 0dBm RX Sensitivity Max -17dBm -20dBm -22dBm -24dBm Wavelength 850nm 1310nm 1310nm 1550nm Laser Type VCSEL FP DFB DFB SFP Gigabit Fiber Transceiver Characteristics * SX Fiber Optic Cable ** LX Fiber Optic Cable Contact Information N-TRON Corp. N-TRON Asia N-TRON Europe GmbH 820 S. University Blvd., Suite 4E Suite #: 2267, 22/F, One Lujiazui Alte Steinhauserstr 19 Mobile, AL 36609 USA 68 Yin Cheng Road Center, 6330 Cham / Zg Switzerland TEL: (251) 342-2164 Pudong New Area TEL: +41 41 7406636 FAX: (251) 342-6353 200120 Shanghai, P.R. China FAX: +41 41 7406637 Website: www.N-TRON.com TEL: +86 (0 ) 21 6194 6777 Email: N-TRON_info@N-TRON.com FAX: +86 (0) 21 6194 6699 ® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Product names mentioned herein are for identi fi cation purposes only and may be trademarks and/or registered trademarks of their respective company. Speci fi cations subject to change without notice. The responsibility for the use and application of N-TRON products rests with the end user. N-TRON makes no warranties as to the fi tness or suitability of any N-TRON product for any speci fi c application. N-TRON Corporation shall not be liable for any damage resulting from the installation, use, or misuse of this product. Printed in USA.
7018FX2 Industrial Ethernet Switch Ordering Information 7018FX2-XX Fourteen 10/100BaseTX Ports, Two Multimode 100BaseFX Fiber Optic Ports, Two Optional Gigabit SFP Ports 7018FXE2-XX Fourteen 10/100BaseTX Ports, Two Singlemode 100BaseFX Fiber Optic Ports, Two Optional Gigabit SFP Ports NTSFP-TX Optional SFP (Mini-GBIC) Transceiver with One 1000BaseT GB Copper Port NTSFP-SX Optional SFP (Mini-GBIC) Transceiver with One 1000BaseSX Multimode GB Fiber Optic Port NTSFP-LX-ZZ Optional SFP (Mini-GBIC) Transceiver with One 1000BaseLX Singlemode GB Fiber Optic Port NTPS-24-1.3 N-TRON Power Supply - (1.3 Amp @ 24VDC) 700-PM Panel Mount kit URMK Universal Rack Mount Kit Where: XX = ST or SC, YY = 15, 40, or 80 for Singlemode, Blank for Multimode E = Singlemode, and Blank Otherwise ZZ = 10, 40, or 80 for GB Singlemode If SFP Transceiver is not speci ed at the time of purchase, slots will remain blank with covers THE INDUSTRIAL NETWORK COMPANY ® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Specifi cations subject to change without notice. Printed in USA. 7018FX2 Industrial Ethernet Switch Ordering Information 7018FX2-XX Fourteen 10/100BaseTX Ports, Two Multimode 100BaseFX Fiber Optic Ports, Two Optional Gigabit SFP Ports 7018FXE2-XX Fourteen 10/100BaseTX Ports, Two Singlemode 100BaseFX Fiber Optic Ports, Two Optional Gigabit SFP Ports NTSFP-TX Optional SFP (Mini-GBIC) Transceiver with One 1000BaseT GB Copper Port NTSFP-SX Optional SFP (Mini-GBIC) Transceiver with One 1000BaseSX Multimode GB Fiber Optic Port NTSFP-LX-ZZ Optional SFP (Mini-GBIC) Transceiver with One 1000BaseLX Singlemode GB Fiber Optic Port NTPS-24-1.3 N-TRON Power Supply - (1.3 Amp @ 24VDC) 700-PM Panel Mount kit URMK Universal Rack Mount Kit Where: XX = ST or SC, YY = 15, 40, or 80 for Singlemode, Blank for Multimode E = Singlemode, and Blank Otherwise ZZ = 10, 40, or 80 for GB Singlemode If SFP Transceiver is not speci ed at the time of purchase, slots will remain blank with covers THE INDUSTRIAL NETWORK COMPANY ® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Specifi cations subject to change without notice. Printed in USA. www.redlion.net Connect. Monitor. Control. Americas sales@redlion.net Asia-Pacific asia@redlion.net Europe Middle East Africa europe@redlion.net +1 (717) 767-6511 ADLD0266 080116 © 2016 Red Lion Controls, Inc. All rights reserved. Red Lion, the Red Lion logo, N-Tron and Sixnet are registered trademarks of Red Lion Controls, Inc. All other company and product names are trademarks of their respective owners. As the global experts in communication, monitoring and control for industrial automation and networking, Red Lion has been delivering innovative solutions for over forty years. Our automation, Ethernet and cellular M2M technology enables companies worldwide to gain real-time data visibility that drives productivity. Product brands include Red Lion, N-Tron and Sixnet. With headquarters in York, Pennsylvania, the company has offices across the Americas, Asia-Pacific and Europe. Red Lion is part of Spectris plc, the productivity-enhancing instrumentation and controls company. For more information, please visit www.redlion.net.