Overview/Product Selection ➊ Maximum load current when mounted on a heat sink. Bulletin 700-SE 20 A (resistive) Max. Continuous Load (Output) Current with Heat Sink 264V AC Max. Load Voltage Range 5,12, or 24V DC Control/Input Voltage Built-in Varistor Helps Absorb Most Electrical Surges Low Profile (Flat Pack) Design Quick-Connect #110 Input and #250 Output Terminals Table Of Contents Approximate Input-to- Output Isolation Method Zero Cross Function LED Indicator Rated Output (Load) Max. Current and Voltage Range ➊ Rated Input Control Voltage Cat. No. Factory- stocked Item (single pack) Phototriac Ye s No
5 A at 100…240V AC
5V DC 700-SE05GZZ05 ✔ 12V DC 700-SE05GZZ12 ✔ 24V DC 700-SE05GZZ24 ✔
10 A at 100…240V AC
5V DC 700-SE10GZZ05 ✔ 12V DC 700-SE10GZZ12 ✔ 24V DC 700-SE10GZZ24 ✔
20 A at 100…240V AC
5V DC 700-SE20GZZ05 ✔ 12V DC 700-SE20GZZ12 ✔ 24V DC 700-SE20GZZ24 ✔ No 5V DC 700-SE05GNZ05 ✔ 12V DC 700-SE05GNZ12 ✔ 24V DC 700-SE05GNZ24 ✔ 5V DC 700-SE10GNZ05 ✔ 12V DC 700-SE10GNZ12 ✔ 24V DC 700-SE10GNZ24 ✔ 5V DC 700-SE20GNZ05 ✔ 12V DC 700-SE20GNZ12 ✔ 24V DC 700-SE20GNZ24 ✔
➊ Refer to "Load Current Vs. Ambient Temperature Characteristics" page 45 for information about how to select the correct size of heat sink for your application Description Pkg. Quantity Cat. No. Factory-stocked Item Heat Sink — Panel or DIN Rail Mount ➊ 1 700-S10 ✔ Heat Sink — Panel or DIN Rail Mount ➊ 1 700-S20 ✔ DIN Rail Mounting Pack Standard 35 x 7.5 mm DIN Rail, 1 meter long, 10 rails per package. Order must be for 10 rails or multiples of 10. 10 199-DR1 ✔ Cat No. 700-S10 Cat No. 700-S20 Cat No. 199-DR1
➊ Each 5 A, 10 A, and 20 A model has 5V DC, 12V DC, and 24V DC input versions. ➋ Refer to "Load Current Vs. Ambient Temperature Characteristics" graphs page 45 regarding maximum load current with and without heat sinks. ➌ If the SSR operation is continuous ON/OFF , this value should be reduced by 50%. Refer to the “Inrush Current Resistivity” graphs on page 45 for more details. Control/Input Ratings ➊ Cat. No. Rated Control Voltage Operating Control Voltage Range Input Impedance Control Voltage Levels With Zero Cross Function Without Zero Cross Function Pick-up Voltage Drop-out Voltage 700-SE_ _ _Z05 5V DC 4…6V DC 250 Ω ± 20% 300 Ω ± 20% 4V DC max. Load/Output Ratings Cat. No. Applicable Load Rated Load Voltage Load Voltage Range Continuous Load Current (Resistive) Max. Inrush Current ➌With Heat Sink ➋ Without Heat Sink ➋ Min. Max. Min. Max. 700-SE05… 100…240V AC 75…264V AC 0.1 A 5 A 0.1 A 5 A 60 A (@50/60 Hz, 1 cycle) 700-SE10… 0.1 A 10 A 0.1 A 5 A 150 A (@50/60 Hz, 1 cycle) 700-SE20… 0.1 A 20 A 0.1 A 5 A 220 A (@50/60 Hz, 1 cycle) Characteristics Load Switching Method/Device Triac Pick-up time 1/2 of load power source cycle + 1 ms max. 1 ms max. Drop-out time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Output Leakage current 5 mA max. (at 100V AC) 10 mA max. (at 200V AC) Output V DRM VCEO (V) 600 600 Output di/dt (A/uS) SE05GZ=100 SE10GZ & SE20 GZ =50 SE05GN=100 SE10 GN & SE20GN =50 Output dv/dt (V/uS) SE05GZ=200, SE10GZ=500, SE20GZ=100 SE05GN =200, SE10GN =500, SE20GN =100 Output I2t (A2S) SE05GZ =24.5, SE10GZ =60, SE20GZ =260 SE05GN =24.5, SE10GN =60, SE20GN =260 Output Tj (°C) max. 125 125 Insulation resistance 100 MΩ min. (at 500V DC) Dielectric strength 2,000V AC, 50/60 Hz for 1 min. Vibration resistance (max.) 10…55 Hz, 1.5 mm double amplitude (10 G) Shock resistance (max.) 1,000 m/s2 (100 G) Ambient temperature Operating: –30…80 °C (–22…176 °F) with no icing or condensation Storage: –30…100 °C (–22…212 °F) with no icing or condensation Ambient humidity Operating 45…85% (no condensation) Standards UL 508, CSA C22.2 , TUV, CE Weight Approx. 37 g
Specifications, Continued Load Current vs. Ambient Temperature Characteristics Inrush Current Resistivity➊ ➊ Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitiv e inrush current will damage the SSR. 700-SE05… 700-SE10… 700-SE20… Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) Load current (A) Load current (A) Load current (A) Without heat sink Without heat sink With standard heat sink (700-S10) or aluminum plate measuring 100 mm x 100 mm x 2 mm (W x H x D) Without heat sink With standard heat sink (700-S20) or aluminum plate measuring 300 mm x 300 mm x 2 mm (W x H x D) Energizing time (ms) Inrush current (A. Peak) Energizing time (ms) Inrush current (A. Peak) Energizing time (ms)
Mounting Considerations➊➋➌ Note: All units are in millimeters unless otherwise indicated. Dimensions are not intended for manufacturing purposes. ➊ The proper mounting orientation of the heat sink is so the heat fins run perpendicular to the floor (vertical) to maximize ventilation flow. If the fins do not run perpendicular to the floor, a 30% current derating is required. ➋ When attaching a heat sink to Bulletin 700-SE, apply heat conductive grease on the heat sink to maximize heat transfer between the SSR and the heat sink. Recommended types: Silicon based, Toshiba YG6240; Non-silicon based, AOS company type 53300. Heat Sinks Basic Application Considerations Because the operation time of Bulletin 700-SE is extremely short, take measures to suppress noise induced between the input terminals. If generation of strong noise is expected, connect an external noise absorber such as an RC circuit. Do not apply excessive force to the terminals. Exercise care when pulling or inserting the terminal clips. Bulletin 700-SE has a built-in varistor to absorb most inrush/surge currents when operating AC inductive loads If additional s uppression is required, connect an external varistor across the load device terminals. Select a varistor that meets the load voltage outlined in the table below. For additional details on applying solid-state relays, refer to pub. 700-AT001A-EN-P , "Solid-State Relay Application Guide." Document available at www.theautomationbookstore.com. Load Voltage Varistor Voltage Varistor Surge Resistance 100…120V AC 240…270 V 1000 A min.200…240V AC 440…470 V 380…480V AC 820…1000 V Mounting Holes Terminal Arrangement/ Internal Connections (Top View) Two, 3.5-dia. or M3 holes 3 + 4 - InputInput voltage Load power supply LoadInput 14.5 6.5 7.1 2.9 7.95 37.5 max. 47.5 max. 3.5 dia. hole 11.5 max. Two #110 (t = 0.5) (Faston tab or equivalent)* Two #250 (t = 0.8) (Faston tab or equivalent) 30±0.5 30±0.2 4.6 dia. hole Two, M3 holes Two, M4 holes 5.647.6 77 max. 90±0.3 100 max. 35 30.5±0.3 44 max. 30 5 4.56 47 max. Two, 3.2-dia. holes 51 max. 35±0.2 90±0.4 Two, 4.4-dia. or M4 holes 4.6 dia. hole Two, M3 holes Two, M4 holes 35 30.5±0.3 47.6 77 max. 90±0.3 100 max. 5.6 71 max. 100 max. 4.5 75 max. Two, 3.2-dia. holes 28 13 35±0.2 90±0.4 Two, 4.4-dia. or M4 holes Cat. No. 700-S10 Mounting Holes ➍ Cat. No. 700-S20 Mounting Holes Weight: Approx. 200 g Weight: Approx. 400 g R C Input SSR