Product data sheet 6AV6640-0CA11-0AX0 SIMATIC TOUCH PANEL TP 177MICRO FOR SIMATIC S7- 200 5.7" BLUE MODE STN DISPLAY CONFIGURABLE WINCC FLEXIBLE 2004 MICRO HSP UPWARDS; CONTAINS OPEN-SOURCE-SW, WHICH IS PROVIDED FREE OF CHARGE. FOR DETAILS SEE ENCLOSED CD Display Design of display STN Screen diagonal 5.7 in Size 5.7" Display type STN, 4 blue levels Color type Blue levels Resolution (pixels) Horizontal image resolution 320 Vertical image resolution 240 Resolution (WxH in pixel) 320 x 240 Backlighting MTBF backlighting (at 25 °C) about 50000 hours Control elements Control elements Touch screen Operating options Touch Function keys, programmable none Keyboard fonts freely inscribable membrane keys No Number of function keys with LEDs 0 6AV6640-0CA11-0AX0 Page 1/ 07/12/2013 subject to modifications © Copyright Siemens AG 2013

Numeric/alphabetical input Yes / Yes hexadecimal keyboard Yes Multi-key operation No Touch operation Touch screen Analog, resistive Supply voltage Supply voltage 24 V DC Input current Rated current 0.24 A Inrush current A²s 0.5 A²·s Power Power 6 W Processor Processor ARM Processor type ARM Memory Type Flash Usable memory for user data 256 KB usable memory for user data Time of day Clock Type Software clock, no battery backup Interfaces Interfaces 1 x RS485 (max. 187.5 Mbit/s) Number of RS 485 interfaces 1 Transmission rate, max. 187.5 kbit/s Degree and class of protection Front IP65, NEMA 4x (when installed) Type of protection IP20 IP (at the front) IP65 NEMA NEMA 4X Rear IP20 Standards, approvals, certificates Certifications CE, GL, ABS, BV, DNV, LRS, FM Class I Div. 2, UL, CSA, cULus, EX Zone 2/22, C-TICK, NEMA 4x FM Class I Div. 2 Yes GL Yes ABS Yes BV Yes DNV Yes 6AV6640-0CA11-0AX0 Page 2/ 07/12/2013 subject to modifications © Copyright Siemens AG 2013

Mounting position vertical maximum permissible angle of inclination without external ventilation +/- 35 ° Storage/transport temperature Transport, storage -20 °C to +60 °C Relative humidity max. relative humidity 90 % Operating systems Operating system LINUX Configuration Configuration software Configuration tool WinCC flexible Micro Version 2004 SP1, HSP or higher (to be ordered separately) 2nd configuration kit WinCC flexible Micro Version Version 2004 SP 1; HSP Configuration tool WinCC flexible Type Micro Languages Online languages Number of online/runtime languages 5 Languages Languages per project 32 Functionality under WinCC (TIA Portal) Libraries Yes Task planner Yes Help system Yes Number of characters per info text 320 Number of tooltips 0 With alarm logging system (incl. buffer and acknowledgment) Number of alarm classes 32 Number of messages 500 6AV6640-0CA11-0AX0 Page 3/ 07/12/2013 subject to modifications © Copyright Siemens AG 2013

Number of bit messages 500 Number of analog messages 20 Telegram message procedure Alarm S No System messages HMI Yes System messages PLC Yes System messages, other (SIMATIC S7, Sinumerik, Simotion, ...) No Message length (in characters) 80 Lines 1 Number of process values per message 8 Acknowledgment groups Yes Message indicator Yes Acoustic feedback No First/last value Yes Variables Number of variables per device 250 Number of variables per screen 20 Limit values Yes Multiplexing Yes Structs No Images Number of configurable images 250 Permanent window/default Yes Start screen configurable Yes Image selection by PLC No Image number in the PLC No Image objects Text objects 500 text elements Fields per image 20 Date/time fields 0 Index of screen context No Return No Graphics object Bit maps, icons, icon (full-screen), vector graphics Icons 1 Icon (full screen) 1 Complex image objects Status/control Not possible 6AV6640-0CA11-0AX0 Page 4/ 07/12/2013 subject to modifications © Copyright Siemens AG 2013

dynamic objects Diagrams, bar graphs Number of curves per diagram 1 Number of bars per chart 5 Limit value lines Yes alphanumeric fields 0 alphanumeric fields per image 0 numerical fields 0 numerical fields per image 0 Password errors 0 Number of slides per image 0 Number of analog indicators per image 0 Number of visible switches per project 0 visible switches per image 0 hidden switches per image 0 Number of status switches per project 0 Button status switches per image 0 Number of selector switches per project 0 Selector switches per image 0 Number of decade switches per project 0 Decade switches per image 0 Number of signal lamps per project 0 Signal lamps per image 0 Attributes for dynamic objects Color change No X/Y movement No Hide Yes Angle of turn No Lists Number of text lists per project 150 Number of graphics lists per project 100 Security Number of user groups 1 Number of users 1 Password export/import Yes Transfer (upload/download) Transfer of configuration serial Process coupling Connection to controller for S7-200, see section on "System interfaces" S7-200 Yes 6AV6640-0CA11-0AX0 Page 5/ 07/12/2013 subject to modifications © Copyright Siemens AG 2013

PPI (point-to-point) Yes PPI network Yes MPI Yes PROFIBUS DP No S7-300/400 No MPI No PROFIBUS DP No PROFINET No S5 No serial No PROFIBUS DP No TI 505 No Allen Bradley (DF1) No Allen Bradley (DF485) No Mitsubishi (FX) No Mitsubishi (MP4) No Telemechanique (ADJUST) No Telemecanique (Uni-Telway) No OMRON (LINK/Multilink) No Modicon (Modbus) No GE-Fanuc (SNP) No Functions Key repeat No TAB sequence Yes Calculating functions Yes Animate No Menu tree editor No Unit switchover No Service tools/configuration aids Clean screen Yes Touch calibration Yes Backup/restore Yes Simulation No Device switchover Yes Delta transfer No Monitoring function for battery and memory No Trace (operation archive) No Expandability/openness Open Platform Program No 6AV6640-0CA11-0AX0 Page 6/ 07/12/2013 subject to modifications © Copyright Siemens AG 2013

Front of enclosure (W x H) 212 mm x 156 mm Weight Weight (without packaging) 0.75 kg other free hotline Yes Warranty period 1 a Status Jul 10, 2013 6AV6640-0CA11-0AX0 Page 7/ 07/12/2013 subject to modifications © Copyright Siemens AG 2013