6757 BURKERT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 13

Technical content

Visit product website  DATA SHEET Type 2505  10 mm socket for Bürkert small solenoid valves Standard | EU | en | 2023-10-25 | 02 2/2 or 3/2-way Whisper Valve with media separation

  • Very fast switching at a low noise level < 45 dB(A) High pressure range up to 16 bar with nominal diameter DN 1.4 mm Highest chemical resistance Compact design with 18 mm installation width High back pressure tightness The combination of maximum flow and minimum valve size is becoming increas- ingly important in various medical and IVD related applications. Combined with high chemical resistance, this explains the broad range of applications for Type 6757. However, in addition to the flow, this valve is also able to switch pres- sures of up to 16 bar. This is a highlight of particular relevance for applications in the area of environmental analysis. The devices from the areas mentioned, includ ing the valves, need to be flushed, cleaned, disinfected and sometimes even steri- lised. Therefore, they need to withstand flushing cycles with high temperatures and/or high pressure, which is precisely what the Type 6757 was designed for. The product is thus ideally suitable for applications such as endoscope cleaning or dialysis, but also for use in environmental analysers. Fast switching times, as implemented here, guarantee high process safety because reliable switching behaviour is an important aspect for accurate dosing and reproducible processes. Product variants described in the data sheet may differ from the product presentation and description. Type description Can be combined with Type 6757 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 13Visit product website  Table of contents 1. General technical data 3 1.2. Medium pressure 1.3. Flow characteristics 2. Product versions 6 Circuit functions Approvals and conformities 4.2. Conformity 4.3. Standards 4.4. Drinking water 4.5. Foods and beverages/Hygiene 5. Materials 7 5.2. Material specifications 6. Dimensions 8 6.2. Width per station 6.3. Flange pattern 6.4. Threaded version 7. Ordering information 12 7.2. Bürkert product filter 7.3. Ordering chart 7.4. Ordering chart accessories Rectangular cable plug Type 2505

3 | 13Visit product website  1. General technical data 1.1. General data Product properties Dimensions Further information can be found in chapter “6. Dimensions” on page 8 Material Seal FFKM, EPDM, (FKM on request) Fluidic housing PEEK, PPS Internal volume Flange version WW A DN 1.4: 550 µl Informations about further versions are available on request. Orifice DN 1.4…DN 4.0 Typical product service life 10 million switching cycles (according to laboratory endurance test) 1.) Performance data Pressure range Further information can be found in chapter “1.2. Medium pressure” on page 4 Duty cycle 2.) Single assembly 100 % continuous operation Block assembly 70 % continuous operation (max. 10 min. duty cycle) Refer to Type 6757 operating instructions for more information. Switching noise 45 dB (A) 3.) Switching time Opening: ca. 7 ms (Pressure build-up 0…10 %) Closing: ca. 7 ms (Pressure reduction 100…90 (Measurement at the valve outlet at 20 °C according to DIN ISO 12238:2001) Electrical data Operating voltage 24 V DC (12 V on request) Nominal power 4.5 W 4.) Voltage tolerance ± 5 % (including residual ripple) Medium data Medium temperature FFKM: + 15…+ FKM: 0…+ EPDM: 0…+ °C permissible for cleaning cycles (max. 30 minutes) 2.) Viscosity Max. 21 mm2/s Process/Port connection & communication Electrical connection Rectangular plug Type 2505 Further information can be found in chapter “Rectangular cable plug Type 2505” on page 13 Port connection Bürkert flange (18 x 69 mm) G G Approvals and conformities Degree of protection IP30 according to EN 60529 Drinking water Further information can be found in chapter “4.4. Drinking water” on page 7 Foods and beverages/Hygiene Further information can be found in chapter “4.5. Foods and beverages/Hygiene” on page 7 Environment and installation Installation position As required, preferably with actuator upright Ambient temperature FFKM: + 15…+ FKM: 0…+ EPDM: 0…+ 1.) The service life depends on the medium, temperature, pressure, sealing material and individual operating conditions. 2.) The maximum body temperature must not exceed + 110 °C. In continuous operation, care must be taken to ensure sufficient heat dissipation (convection) on the metal surface of the valve. Overheating of the valve can lead to damage. The valve must not be cycled during the flushing cycles. 3.) Measured in sound measurement chamber according to ISO3745 accuracy class 1. The value may differ under other conditions. 4.) No further power reduction possible

4 | 13Visit product website  1.2. Medium pressure Circuit function Orifice Pressure range at the connection Max. differential pressure 1.) Flow direction BLIND COM NC [mm] [bar] [bar] [bar] [bar] A 1.4 – Vac…16 16 NC  COM 2 – Vac…10 10 3 – Vac…6 6 4 – Vac…3 3 Circuit function Orifice Pressure range at the connection Max. differential pressure 1.) Flow direction NO COM Blind [mm] [bar] [bar] [bar] [bar] B 1.4 Vac…16 – 16 NO  COM

2 Vac…10 – 10

3 Vac…6 – 6

4 Vac…3 – 3

Circuit function Orifice Pressure range at the connection Max. differential pressure 1.) Flow direction NO COM NC [mm] [bar] [bar] [bar] [bar] T 1.4 Vac…10 10 All flow directions allowed2 Vac…6 6

3 Vac…3 3

4 Vac…1.5 1.5 1.) For vacuum operation, observe the permissible differential pressure and flow direction. 1.3. Flow characteristics KV value water Circuit function Port connection DN K V value water 1.) NC  COM NO  COM COM  NC COM  NO [m3/h] [m3/h] [m3/h] [m3/h] A Flange, G ⅛ 1.4 0.055 – – – Flange, G ⅛ 2 0.080 – – – Flange, G ¼ 3 0.200 – – – Flange 4 0.370 – – – G ¼ 4 0.330 – – – B Flange, G ⅛ 1.4 – 0.055 – – Flange, G ⅛ 2 – 0.080 – – Flange, G ¼ 3 – 0.200 – – Flange 4 – 0.360 – – G ¼ 4 – 0.330 – – T Flange, G Flange, G ⅛ 2 0.080 0.080 0.080 0.080 Flange, G ¼ 3 0.200 0.200 0.240 0.240 Flange 4 0.360 0.360 0.425 0.425 G ¼ 4 0.330 0.330 0.380 0.380 1.) Measurement at + 20 °C, 1 bar at the valve inlet and free outlet

5 | 13Visit product website  CV value water Circuit function Port connection DN C V value water NC  COM NO  COM COM  NC COM  NO [m3/h] [m3/h] [m3/h] [m3/h] A Flange, G ⅛ 1.4 0.064 – – – Flange, G ⅛ 2 0.092 – – – Flange, G ¼ 3 0.231 – – – Flange 4 0.428 – – – G ¼ 4 0.382 – – – B Flange, G ⅛ 1.4 – 0.064 – – Flange, G ⅛ 2 – 0.092 – – Flange, G ¼ 3 – 0.231 – – Flange 4 – 0.416 – – G ¼ 4 – 0.382 – – T Flange, G Flange, G ⅛ 2 0.092 0.092 0.092 0.092 Flange, G ¼ 3 0.231 0.231 0.277 0.277 Flange 4 0.416 0.416 0.491 0.491 G ¼ 4 0.382 0.382 0.439 0.439 QNn value air Circuit function Port connection DN Q Nn value air NC  COM NO  COM COM  NC COM  NO [m3/h] [m3/h] [m3/h] [m3/h] A Flange, G ⅛ 1.4 60 – – – Flange, G ⅛ 2 86 – – – Flange, G ¼ 3 215 – – – Flange 4 400 – – – G ¼ 4 355 – – – B Flange, G ⅛ 1.4 – 60 – – Flange, G ⅛ 2 – 86 – – Flange, G ¼ 3 – 215 – – Flange 4 – 390 – – G ¼ 4 – 355 – – T Flange, G ⅛ 1.4 60 60 65 65 Flange, G ⅛ 2 86 86 86 86 Flange, G ¼ 3 215 215 260 260 Flange 4 390 390 440 440 G ¼ 4 355 355 405 405

6 | 13Visit product website  2. Product versions Sub-base version PPS Sub-base version PEEK Threaded version G ⅛ PPS Threaded version G ¼ PEEK 3. Circuit functions Symbol Description NC Circuit function A (CF A) 2/2-way solenoid valve Direct-acting Normally closed NO Circuit function B (CF B) 2/2-way solenoid valve Direct-acting Normally open NC NO Circuit function T (CF T) 3/2-way solenoid valve Direct-acting Flow direction optional Universal 4. Approvals and conformities 4.1. General notes

  • The approvals and conformities listed below must be stated when making enquiries. This is the only way to ensure that the pro duct complies with all required specifications. Not all available versions can be supplied with the below mentioned approvals or conformities. 4.2. Conformity In accordance with the Declaration of Conformity, the product is compliant with the EU Directives. 4.3. Standards The applied standards which are used to demonstrate compliance with the EU Directives are listed in the EU-Type Examination Certificate and/or the EU Declaration of Conformity.

7 | 13Visit product website  4.4. Drinking water Conformity Description Optional: Certification according to 1+ system of UBA (valid for variable code PF23) The materials comply with the assessment principles (UBA) for materials in contact with drinking water (Trinkwas- serV). 4.5. Foods and beverages/Hygiene Conformity Description FDA FDA – Code of Federal Regulations (valid for the variable code PL02, PL03) All wetted materials are compliant with the Code of Federal Regulations published by the FDA (Food and Drug Administration, USA) according to the manufacturer‘s declaration. 5. Materials 5.1. Bürkert resistApp Bürkert resistApp – Chemical resistance chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start chemical resistance check 5.2. Material specifications No. Element Material

1 Cover PA

2 Coil housing Nickel-plated

3 Valve housing PPS

4 Diaphragm

1.) FFKM, EPDM, (FKM on request)

5 Fluid housing

1.) PEEK, PPS

6 Flange seal

1.) FFKM, EPDM, (FKM on request)

7 Oval head screw Stainless steel

1.) in contact with medium

8 | 13Visit product website  6. Dimensions 6.1. Flange version Note: Dimensions in mm 78.7 73.7 5.08 0.64 18.3 7.2 59.5 4.1

9 | 13Visit product website  6.2. Width per station Note: Dimensions in mm 18.5 18.5 18.5

10 | 13Visit product website  6.3. Flange pattern Note: Dimensions in mm Note the position of the electrical connection Preferred threaded connection Further possible threaded connection 2/2-way WW A R4.8 59.5 1.) 1.) 1.) 1.) 1.) 1.) M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 R4.8 59.5 M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 R4.8 59.5 M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 NO COM NC NO COM NC COM NC COM NC NO COM NO COM Kennzeichnung Elektrischer Anschluss R4.8 59.5 1.) 1.) 1.) 1.) 1.) 1.) M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 R4.8 59.5 M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 R4.8 59.5 M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 NO COM NC NO COM NC COM NC COM NC NO COM NO COM Kennzeichnung Elektrischer Anschluss 2/2-way WW B R4.8 59.5 1.) 1.) 1.) 1.) 1.) 1.) M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 R4.8 59.5 M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 R4.8 59.5 M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 NO COM NC NO COM NC COM NC COM NC NO COM NO COM Kennzeichnung Elektrischer Anschluss R4.8 59.5 1.) 1.) 1.) 1.) 1.) 1.) M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 R4.8 59.5 M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 R4.8 59.5 M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 NO COM NC NO COM NC COM NC COM NC NO COM NO COM Kennzeichnung Elektrischer Anschluss 3/2-way WWT R4.8 59.5 1.) 1.) 1.) 1.) 1.) 1.) M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 R4.8 59.5 M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 R4.8 59.5 M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 NO COM NC NO COM NC COM NC COM NC NO COM NO COM Kennzeichnung Elektrischer Anschluss R4.8 59.5 1.) 1.) 1.) 1.) 1.) 1.) M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 R4.8 59.5 M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 R4.8 59.5 M4 min. 6 max. 5.6 R4.8 59.5 M4 min. 6 max. 5.6 7.2 NO COM NC NO COM NC COM NC COM NC NO COM NO COM Kennzeichnung Elektrischer Anschluss 1.) Electrical connection

11 | 13Visit product website  6.4. Threaded version Note: Dimensions in mm G ⅛ and G 78.7 38.5 5.1 A B 73.7 45° 5.08 0.64 18.3 Port connection A B Threaded connection G ¼ 9 G ⅛ 7

12 | 13Visit product website  7. Ordering information 7.1. Bürkert eShop Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 7.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter 7.3. Ordering chart Note: Other versions are available on request. 2x M4 x 10 fixing screws for sub-base versions are included in the delivery. Connectors for rectangular plug are ot included in the scope of delivery and must be ordered separately, see “7.4. Ordering chart accessories” on page 13 Circuit function Port connection Orifice Voltage/ Frequency Pressure range Max. pressure difference Body material Seal material Article no. [mm] [V/Hz] [bar] 1.) 2.) [bar] CF A 2/2-way solenoid valve Direct-acting Normally closed NC Flange 1.4 024/DC Vac…16 16 PEEK FFKM 324226  Flange 1.4 Vac…16 16 PPS EPDM 20049070 Flange 2 Vac…10 10 PEEK FFKM 20046836 Flange 3 Vac…6 6 PEEK FFKM 20046840 Flange 4 Vac…3 3 PEEK FFKM 324233 Flange 4 Vac…3 3 PPS EPDM 20049077 G ⅛ 1.4 Vac…16 16 PEEK FFKM 338875 G ⅛ 1.4 Vac…16 16 PPS EPDM 20049078 G ¼ 4.0 Vac…3 3 PEEK FFKM 20042773 G ¼ 4.0 Vac…3 3 PPS EPDM 20049085 CF B 2/2-way solenoid valve Direct-acting Normally open NO Flange 1.4 024/DC Vac…16 16 PEEK FFKM 324231  Flange 1.4 Vac…16 16 PPS EPDM 20071609 Flange 4 Vac…3 3 PEEK FFKM 324234 Flange 4 Vac…3 3 PPS EPDM 20071612

13 | 13Visit product website  Circuit function Port connection Orifice Voltage/ Frequency Pressure range Max. pressure difference Body material Seal material Article no. [mm] [V/Hz] [bar] 1.) 2.) [bar] CF T 3/2-way solenoid valve Direct-acting Flow direction optional Universal NC NO Flange 1.4 024/DC Vac…10 10 PEEK FFKM 324232  Flange 1.4 Vac…10 10 PPS EPDM 20049071 Flange 2 Vac…6 6 PEEK FFKM 20046838 Flange 3 Vac…3 3 PEEK FFKM 20046843 Flange 4 Vac…1.5 1.5 PEEK FFKM 324235 Flange 4 Vac…1.5 1.5 PPS EPDM 20005572 G ⅛ 1.4 Vac…1.5 1.5 PEEK FFKM 338877 G ⅛ 1.4 Vac…1.5 1.5 PPS EPDM 20049079 G ¼ 4.0 Vac…1.5 1.5 PEEK FFKM 366049 G ¼ 4.0 Vac…1.5 1.5 PPS EPDM 20049086 1.) Pressure data: overpressure to atmospheric pressure 2.) The water hammer with incompressible media must not exceed the max. permissible differential pressure. 7.4. Ordering chart accessories Rectangular cable plug Type 2505 Note: For further versions see data sheet Type 2505 Accessories Description Article no. Rectangular cable plug Type 2505 with 3 m cable 252572  Rectangular cable plug Type 2505 with 5 m cable 255194 Rectangular cable plug Type 2505 with 300 mm flying leads 644068  Rectangular cable plug Type 2505 with 600 mm flying leads 162144