8640 BURKERT | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 32
Technical content
Visit product website DATA SHEET Type 6524 3/2-way or 2 x 3/2-way solenoid valve for pneumatic applications Type 6525 5/2-way solenoid valve for pneumatic applica- tions Type 8614 Pneumatic control cabinet solutions for hygienic process environments Type 0498 Double pilot controlled check valve for realising 5/3-way function with all ports blocked Type 2000 Pneumatically operated 2/2-way angle seat valve CLASSIC Standard | EU | en | 2023 - 10 - 02 | 18 Modular valve island for pneumatics
- Compact design Modular configuration Higher flexibility in control cabinet due to AirLINE Quick Simple exchange of valves (with option “P-shut-off” – also possible during operation) The 8640 valve unit system is designed to solve diverse and complex control prob- lems due to its systematic modular construction and combination of pneumatic and electrical interfaces. By putting together a row of pneumatic modules with different numbers of valves, 2 to 24 valve functionalities may be realized on one valve unit. Electrical connectivity is achieved by either fieldbus interfaces, common connection (parallel connection technique) or multipin interfaces. The valves allow different applications to be covered. Bodies and connection modules are made of high-quality plastic (polyamide) and are easy to assemble by means of the built-in snap connectors. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 8640 © Christian Bürkert GmbH & Co. KG, Subject to alteration
2 | 32Visit product website Table of contents 1. General technical data 4 1.2. Solenoid valves Type 6524 and Type 6525 1.3. Solenoid valves Type 0460 1.4. Solenoid valves Type 6526 and Type 6527 1.5. Solenoid valve Type 5470 1.6. AirLINE Quick 2. Product versions 11 2.2. Distinguishing features Valve island Module Valves 3. Circuit functions 13 3.2. SIA variant 4. Approvals and conformities 14 4.2. Conformity 4.3. Standards 4.4. Explosion protection 4.5. North America (USA/Canada) 5. Materials 14 6. Dimensions 15 6.2. Pneumatics 16 mm width per station 7. Device/Process connections 17 7.2. Fieldbus modules 8. Product design and assembly 18 Electronics Pneumatics 11 mm width per station Pneumatics 16 mm width per station AirLINE Quick adapter Type 8640 programme 9. Ordering information 22 9.2. Bürkert product filter 9.3. Ordering chart replacement valves Solenoid valves Type 6524 and Type 6525 Solenoid valves Type 0460 Solenoid valves Type 6526 and Type 6527
3 | 32Visit product website 9.4. Ordering chart accessories Cover plate Blind plates AirLINE Quick Bus Y-piece RIO cable for bus extension 9.5. Ordering chart spare parts Spare parts SVVI for Type 8640, REV1, REV2 – Pneumatics 11 mm width per station Spare parts SVVI for Type 8640, REV1, REV2 – Pneumatics 16 mm width per station Spare parts SVVI for Type 8640, REV3 – Pneumatics 11 mm width per station Spare parts SVVI for Type 8640, REV3 – Pneumatics 16 mm width per station
4 | 32Visit product website 1. General technical data 1.1. General data Note: Further information can be found in chapter: Type 6524, 6525 “1.2. Solenoid valves Type 6524 and Type 6525” on page 6 Type 0460 “1.3. Solenoid valves Type 0460” on page 7 Type 6526, 6527 “1.4. Solenoid valves Type 6526 and Type 6527” on page 8 Type 5470 “1.5. Solenoid valve Type 5470” on page 9 Product properties Type 0460, Type 6524, Type 6525 Type 6526, Type 6527 Type 5470 Dimensions Further information can be found in chapter “6. Dimensions” on page 15 Material Body PA (polyamide), aluminium (Type 0460) PA (polyamide), aluminium PA (polyamide) Seal FKM, NBR and PUR NBR NBR Maximum installation width of a valve island Further information can be found in chapter “6. Dimensions” on page 15 Width per station 11 mm 16.5 mm 19 mm Manual override Standard Standard Standard Number of valve positions For single valves: 24 For impulse and double valves: max. 12 Max. 24 Max. 24 Maximum number of valve functions Max. 24 Max. 24 Max. 24 Switching function/ Operating principle 1.) Further information can be found in chapter “3. Circuit functions” on page 13. Pneumatic intermediate supply Possible via centre feed plate on a valve position Possible via centre feed plate on a valve position Possible via centre feed plate on a valve position Performance data Pressure data Overpressure to atmospheric pressure Overpressure to atmospheric pressure Overpressure to atmospheric pressure Pressure range Vac.…to 10 bar Vac.…to 10 bar 2…10 bar External supply air (auxiliary pilot air) 2.5 bar (0460: not possible) > bar Not possible Flow rate QNn value air 300 l/min measured at + 20 °C, bar pressure at valve inlet and bar differential pressure 500…700 l/min measured at °C, 6 bar pressure at valve inlet and 1 bar differential pressure 300 l/min measured at + 20 °C, bar pressure at valve inlet and bar differential pressure Flow rate QNn value air with integrated P shut-off Flow reduced by approximately 25 N/A N/A Nominal operating mode Continuous operation, 100 % duty cycle Continuous operation, 100 % duty cycle Continuous operation, 100 % duty cycle Switching time Measured according to ISO 12238 Measured according to ISO 12238 Measured according to ISO 12238 Electrical data Operating voltage 24 V DC 24 V DC 24 V DC Voltage tolerance ± % ± % ± Residual ripple (at DC) 1 Vss 1 Vss 1 Vss Nominal power of each valve For single valves: 0.8 W For impulse and double valves: 2x 0.8 W with power reduction W, 1 W 1 W, 2 W, 3 W Nominal current of each valve See total current See total current See total current Position feedback Max. 32 Max. 32 Max. 32 Protection class III according to VDE 0580 III according to VDE 0580 III according to VDE 0580 Total current Depending on the electrical connection technology With common collective connection Max. 3 A (total current of the individual valves) With multipole connection Max. 3 A (total current of the individual valves) + max. 3 A (repeater) With fieldbus connection ITOTAL = IBASE + (n x IVALVE) + (m x IREPEATER) n=quantity of valves, m=quantity of repeaters, IVALVE= rated current of each valve IREPEATER= rated current of each repeater, m x IREPEATER=max. 650 mAIBASE= 200 mA specific base current Profibus-DP
5 | 32Visit product website Medium data Operating medium Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended) Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended) Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended) Compressed air quality ISO 8573 1: 2010, Class 7.4.4 ISO 8573 1: 2010, Class 7.4.4 ISO 8573 1: 2010, Class 7.4.4 Approvals and conformities Degree of protection IP20 IP65 in closed control cabinets IP20 IP65 in closed control cabinets IP20 IP65 in closed control cabinets Explosion protection Further information can be found in chapter “4.4. Explosion protection” on page 14 North America (USA/ Canada) Further information can be found in chapter “4.5. North America (USA/Canada)” on page 14 Process/Port connection & communication Working port D 6, D ¼ D
8 D6, SL 6/4, G
¼, D ⅜ G ⅜ G ¼, G ⅛, NPT ¼, D10, D8 Communication module ME01 ME01 ME01 Communication interface Collective connection (parallel connections) / Multipole (D-Sub, 25-pin) / PROFIBUS-DP / PROFINET IO / EtherNet/IP / Modbus TCP Collective connection (parallel connections) / Multipole (D-Sub, 25-pin) / PROFIBUS-DP / PROFINET IO / EtherNet/IP / Modbus TCP Collective connection (parallel connections) / Multipole (D-Sub, 25-pin) / PROFIBUS-DP / PROFINET IO / EtherNet/IP / Modbus TCP Environment and installation Installation position As required, preferably with actuator upright As required, preferably with actuator upright As required, preferably with actuator upright Storage temperature - 20…+ °C - 20…+ °C - 20…+ Ambient temperature 0…+ (with Type 0460: 0…+ °C) 0…+ (with Type 0461: 0…+ °C) 10…+ 1.) The maximum flow rate depends on the valve function.
6 | 32Visit product website 1.2. Solenoid valves Type 6524 and Type 6525
- The pilot valves Type 6524 (single and double valve) and Type 6525 (single valve) consist of a pilot flipper solenoid valve Type 6144 and a pneumatic seat valve. The operating principle allows switching of high pressures with low power consumption and short switching times. The pilot valves are equipped with a manual override as standard. The pneumatic flange pattern of the pilot valves Type 6524 and 6525 (single valves) for Type 8640 REV3 has been standardised. There is a difference to the flange pattern of the pilot valves for Type 8640 REV2. It is therefore imperative to take into account the different article numbers of the pilot valves as described in chapter “9.3. Ordering chart replacement valves” on page 23 Further information about ordering information can be found in chapter “9.3. Ordering chart replacement valves” on page 23 Further information about further valve options can be found in chapter “9.4. Ordering chart accessories” on page 27 Pilot valve Type Type 6524, Type 6525 Type 6524 Circuit function 3/2 and 5/2-way valve 2 3/2-way valve Product properties Materials Body PA (polyamide) Seal FKM, NBR and PUR Width per station 11 mm Manual override Standard Pneumatic module With plug-in coupling, Ø 6 mm, Ø ¼" Performance data Pressure data Overpressure to atmospheric pressure Flow rate QNn value air Measured at + 20 °C, 6 bar pressure at valve inlet and 1 bar difference pressure, see “9.3. Ordering chart replacement valves” on page 23 Duty cycle Continuous operation (100 % duty cycle) Switching time Measured according to ISO 12238 Electrical data Operating voltage 24 V DC (10 % residual ripple permissible) Nominal power of each valve 0.8 W 2 0.8 W with reduction of power Medium data Operating medium Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended) Process/Port connection & communication Service port 2 (A), 4 (B) Plug-in coupling Ø 6 mm, Ø ¼" Air supply connection 1 (P), 3 (R), 5 (S) G Electrical connection (on valve) Rectangular plug, 2-pin, grid spacing 5.08 mm Cable with strands 1.) Rectangular plug, 3-pin, grid spacing 2.54 mm Cable with strands 1.) Environment and installation Installation position As required, preferably with actuator upright Mounting condition With 2 screws M2
20 With 2 screws M2
1.) Versions with safety-related shutdown. The switching contact must be located in the same control cabinet as the valve block. The line length must be limited to a maximum of 2 m.
7 | 32Visit product website 1.3. Solenoid valves Type 0460
- The solenoid valve Type 0460 consists of a pneumatic valve body fitted with a double coil pilot valve. The principle allows switching of high pressures together with low power consumption and fast switching times. All valves are equipped with manual override as a standard. Further information about ordering information can be found in chapter “Solenoid valves Type 0460” on page 24 Further information about further valve options can be found in chapter “9.4. Ordering chart accessories” on page 27 Pilot valve Type Type 0460 Circuit function 5/2-way and 5/3-way bistable Product properties Materials Body Aluminium Seal NBR Width per station 11 mm Manual override Standard Pneumatic module With plug-in coupling, Ø 6 mm, Ø ¼" Performance data Pressure data Overpressure to atmospheric pressure Flow rate QNn value air 300 l/min measured at + 20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure, see “9.3. Ordering chart replacement valves” on page Switching time Measured according to ISO 12238 Electrical data Operating voltage 24 V DC ± Medium data Operating medium Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended) Process/Port connection & communication Service port 2 (A), 4 (B) Plug-in coupling Ø 6 mm, Ø ¼" Air supply connection 1 (P), 3 (R), 5 (S) G Electrical connection (on valve) Rectangular plug, 3-pin, grid 2.54 mm Environment and installation Installation position As required, preferably with actuator upright Mounting condition With 2 screws M1.7
8 | 32Visit product website 1.4. Solenoid valves Type 6526 and Type 6527
- The solenoid valve Type 6526 and Type 6527 consist of a pneumatic valve body fitted with a Type 6106 rocker solenoid valve. The operating principle allows high pressures to be switched with low power consumption and short switching times. The solenoid valves are equipped with manual override as a standard. Further information about ordering information can be found in chapter “Solenoid valves Type 6526 and Type 6527” on page 25 Further information about further valve options can be found in chapter “9.4. Ordering chart accessories” on page 27 Pilot valve Type Type 6526 Type 6527 Circuit function 3/2-way valve 5/2-way valve Product properties Material Body PA (polyamide) Seal NBR Width per station 16.5 mm Manual override Standard Pneumatic modules With plug-in coupling, Ø 8 mm Performance data Pressure data Overpressure to atmospheric pressure Flow QNn value air 300 l/min measured at + 20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure, see “9.3. Ordering chart replacement valves” on page Nominal operating mode Continuous operation (100 % duty cycle) Switching time Measured according to ISO 12238 Electrical data Operating voltage 24 V DC ± Electrical connection (on valve) Tag connector according to DIN EN 175301 803 (previously DIN 43650) form C Nominal power of each valve 2 W, 1 W Medium data Medium Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended) Process/Port connection & communication Service port 2 (A), 4 (B) Plug-in coupling, Ø 8 mm Air supply connection 1 (P), 3 (R), 5 (S) G Environment and installation Installation position As required, preferably with solenoid valve upright Mounting condition With 2 screws M3
9 | 32Visit product website 1.5. Solenoid valve Type 5470
- The solenoid valve Type 5470 consist of a pneumatic valve body fitted with Type 6106 rocker pilot valve. An armature with a tilting bearing, similar or a rocker, tilts within the body of the pilot valve, and switches the valve. The minimal tilting movement of the rocker is non-wearing, and basic lubrication is unnecessary. Type 5470 R is available as a 3/2 and 4/2-way valve. The valves can be mounted together individually using the module flange. In various applica- tions, they can be used advantageously as valve blocks. Different variants are available for service ports 2 and 4. Further information about ordering information can be found in chapter “Solenoid valves Type 5470” on page 26 Further information about further valve options can be found in chapter “9.4. Ordering chart accessories” on page 27 Pilot valve Type Type 5470 Circuit function 3/2-way and 4/2-way valve Product properties Material Body PA (Polyamide) Seal NBR Width per station 18 mm Nominal diameter DN 4.0 Performance data Nominal operating mode Continuous operation (100 % duty cycle) Electrical data Operating voltage 24 V DC, 110…120 V DC, 220…240 V DC (for alternating current, use valves with UC coil) Electrical connection (on valve) Tag connector according to DIN 43 650 Form C, for cable plug Type 2516 Voltage tolerance ± Medium data Medium Oil-free or lubricated compressed dry air (5 μm filter recommended) Medium temperature - 10…+ Process/Port connection & communication Service port connections 2 and 4 (variants) Threaded port G ⅛, threaded port NPT ⅛, tube connection SL 6/4 mm, plug-in coupling Ø 6 mm Air supply connections 1 and 3 Module flange Approvals and conformities Degree of protection IP65 (with cable plug) Further information can be found in chapter “4. Approvals and conformities” on page 14 Environment and installation Installation position As required, preferably with actuator upright Ambient temperature - 10…+
10 | 32Visit product website 1.6. AirLINE Quick Note: The valves of Type 0460 valves cannot be installed with AirLINE Quick due to their size. AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall. Advantages: Reduced space requirement in the control cabinet This makes it possible to use more compact control cabinets Reduced installation effort due to hose connections directly at the bottom of the control cabinet Product properties Material AirLINE Quick Adapter Stainless steel 1.4301 Anodised aluminium Pneumatic connection Stainless steel 1.4301 Nickel-plated brass Valve positions 4, 8, 12, 16, 24 Valve functions Up to 48 Process/Port connection & communication Connection Pneumatic feeding G ¼, D ⅜" Pneumatic service ports Plug-in coupling Ø 6 mm, Ø ¼" Environment and installation Installation position Control cabinet wall Control cabinet floor Valve with 11 mm width/station AirLINE Quick Adapter in stainless steel 1.4301 oder anodised aluminium Pneumatic connections: – Stainless steel 1.4301 – Nickel-plated brass Pneumatic connections: – Plug-in coupling Ø 6 mm – Plug-in coupling Ø ¼" Pneumatic connections Supply/Disposal: – G ¼
11 | 32Visit product website 2. Product versions 2.1. Notes on compatibility and revision levels The single valves Type 6524 and Type 6525, the pneumatic basic and connection modules and as well as the control cabinet base adaptation AirLINE Quick have been optimised. 2.2. Distinguishing features Valve island Visual distinction 11 mm Visual distinction 16 mm Marking on type plate Valve island type W1YMU 8640Made in Germany XXXXXXXX S/N 9999 Serial number Article number Construction date Valve island type W1YMU
8640 REV3Made in Germany
1.) If you have any questions regarding the differences in revisions, please contact your Bürkert sales department.
12 | 32Visit product website Module Channel arrangement of the working connections Parallel Wavy Colour of the release rings (hose connector) Black Blue Flow reduction with integrated P shut-off Up to 50 % Up to 20 1.) If you have any questions regarding the differences in revisions, please contact your Bürkert sales department. Valves Valves Type 6524, Type 6525 Valve REV1 Valve REV2 Visual distinction REV1 Single valves Type 6524 and Type 6525 with flange interface FM14 Different size of the channels REV2 Single valves Type 6524 and Type 6525 with flange interface FM20 Article no. Distinction by Article no., see “9.3. Ordering chart replacement valves” on page 23 Information label There is a information label on the valve which indicates that the valve has been overhauled. This information label must be removed before assembly. Further information can be found in the operating instructions Type 8640
13 | 32Visit product website 3. Circuit functions 3.1. Standard functions Symbol Description 2(A) 1(P) 3(R) Circuit function C (CF C) 3/2-way solenoid valve Servo-controlled, with manual override Normally closed 1 5 1 3 Circuit function C (CF C) 2 x 3/2-way solenoid valve Servo-controlled, with manual override Normally closed 2(B) 1(P) 3(R) Circuit function D (CF D) 3/2-way solenoid valve Servo-controlled, with manual override Normally open 4 2 5 1 3 Circuit function H (CF H) 5/2-way solenoid valve Servo-controlled, with manual override Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. 14 12 4 2 5 1 3 Circuit function L (CF L) 5/3-way solenoid valve With manual override In middle position all ports locked 14 12 4 2 5 1 3 Circuit function N (CF N) 5/3-way solenoid valve With manual override In middle position ports 2 and 4 exhausted 14 12 4 2 5 1 3 Circuit function Z (CF Z) 5/2-way solenoid valve Impulse version with 2 coils and manual override Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. 3.2. SIA variant Symbol Description 2(A) 1(P) 3(R) Circuit function C (CF C) 3/2-way solenoid valve Servo-controlled Normally closed 1 5 1 3 Circuit function C (CF C) 2 x 3/2-way solenoid valve Servo-controlled Normally closed 2(B) 1(P) 3(R) Circuit function D (CF D) 3/2-way solenoid valve Servo-controlled Normally open 2(B) 4(A) 1(P) 3(R) Circuit function G (CF G) 4/2-way solenoid valve Servo-controlled
14 | 32Visit product website 4. Approvals and conformities 4.1. General notes
- The approvals and conformities listed below must be stated when making enquiries. This is the only way to ensure that the pro duct complies with all required specifications. Not all available versions can be supplied with the below mentioned approvals or conformities. 4.2. Conformity In accordance with the Declaration of conformity, the product is compliant with the EU Directives. 4.3. Standards The applied standards which are used to demonstrate compliance with the EU Directives are listed in the EU-Type Examination Certificate and/or the EU Declaration of Conformity. 4.4. Explosion protection The explosion protection approvals for the individual valves can be found in the corresponding data sheets. 4.5. North America (USA/Canada) The North American approvals of the individual valves can be found in the corresponding data sheets. 5. Materials 5.1. Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check
15 | 32Visit product website 6. Dimensions 6.1. Pneumatics 11 mm width per station Note: Dimensions in mm, unless otherwise stated 37.7 198 132.65 193.45 128.2 25.8 32.8 32.8 6.8 107.55 35.5 94.95 Standard rail EN 50022- 35x7.5 or 35x15 56.85 59.4 76.95 70.5 65.6+(n x 11) 10.6 11.8 20.3 12.3 20.8 G1/4 G1/4 Plug-in coupling Ø6 or Ø1/4"
16 | 32Visit product website 6.2. Pneumatics 16 mm width per station Note: Dimensions in mm, unless otherwise stated 132 144,4 209,7 11,3 66 44 73,65 140 205,25 94,95 35,5 3,55 45,25 Standard rail EN 50022- 35x7,5 or 35x15 24,35 10,5 24,35 88+(n x 16,5) 19,65 33,5 85,9 G3/8 G3/8 G1/8 Plug-in coupling
17 | 32Visit product website 7. Device/Process connections 7.1. Collective line modules and multipol modules Module Description Collective connection module
- Connection via individual stranded wires Looped-through ground potential Max. 24 valves Degree of protection IP20 Screw-type terminals Multi-pin module Valve outputs
- Max. 24 valves Degree of protection IP20 Electrical connection plug D-Sub (2-pin) 7.2. Fieldbus modules Module Description PROFIBUS DP
- Max. 24 valves Degree of protection IP20 Max. 32 repeaters (in connection with EME module) Power supply with rectangular plug (4-pin) Bus connection D-Sub (9-pin) RIO connection M8 (4-pin) PROFINET IO, EtherNet/IP, Modbus TCP
- Degree of protection IP20 Max. 24 valves Max. 32 repeaters (in connection with EME module) Transmission rates 10/100 MBits/s with Auto Crossover Power supply with rectangular plug (4-pin) Bus connection RJ45 (2x) RIO connection M8 (4-pin)
18 | 32Visit product website 8. Product design and assembly 8.1. Product assembly Electronics Note: For a selection of basic electrical modules and other modules, see “7.1. Collective line modules and multipol modules” on page and “7.2. Fieldbus modules” on page No. Element
1 Electrical end module, left
2 Terminal module for feedback
3 Extension module for electrical inputs
4 Multi-pin repeater inputs (initiators)
5 Electrical end module, left
6 Basic electrical module standard
7 Fieldbus module
8 Multipin valve outputs
9 Common connection module
19 | 32Visit product website Pneumatics 11 mm width per station No. Element
1 Pneumatic connection module, left
2 Basic pneumatic modules
3 Pneumatic connection module, right
4 Valves (for example 5/2-way)
20 | 32Visit product website Pneumatics 16 mm width per station No. Element
21 | 32Visit product website AirLINE Quick adapter AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve island is directly adapted on the control cabinet floor or wall. Note: Type 0460 valves cannot be installed with AirLINE Quick because of their size. Valves with 11 mm width/station AirLINE Quick Adapter in stainless steel 1.4301 or anodised aluminium Stabilising metal plate, is fixed on the outside of the control cabinet Pneumatic connections Supply/Disposal: – G ¼ Pneumatic connections: – Plug-in coupling Ø 6 mm – Plug-in coupling Ø ¼" Pneumatic connections: – Stainless steel 1.4301 – Nickel-plated brass
22 | 32Visit product website Type 8640 programme Example: Valve block with individual wiring Common electrical connection Multi-pin electrical connection Fieldbus 1 2 3 4 AirLINE Quick Adapter for valve islands on the control cabinet floor or control cabinet wall 9. Ordering information 9.1. Bürkert eShop Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 9.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter
23 | 32Visit product website 9.3. Ordering chart replacement valves Solenoid valves Type 6524 and Type 6525 Note: Further information about this product version can be found in chapter “1.2. Solenoid valves Type 6524 and Type 6525” on page 6 Circuit function Orifice QNn value air 1.) Pressure range Switching times Voltage/ Frequency Article no. Opening Closing Valves for 8640 REV1 3.) Valves for 8640 REV2 3.) [mm] [l/min] [bar] [ms] [ms] [V/Hz] C (CF C) 3/2-way solenoid valve Servo-controlled, with manual override Normally closed 2(A) 1(P) 3(R) 4.0 300 Vac.…7 15 20 24 V DC 20029915 (186258 4.) 20029923 (20013119 4.) 1…10 2.) 15 20 24 V DC 20029913 (186257 4.) 20029921 (20013114 4.) 2.5…10 15 28 24 V DC 20029910 (184043 4.) 20029918 (365606 4.) D (CF D) 3/2-way solenoid valve Servo-controlled, with manual override Normally open 2(B) 1(P) 3(R) 4.0 300 2.5…10 15 28 24 V DC 20029911 (184400 4.) 20029919 (365609 4.) H (CF H) 5/2-way solenoid valve Servo-controlled, with manual override Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. 4 2 5 1 3 4.0 300 1…10 2.) 15 20 24 V DC 20029914 (186271 4.) 20029922 (20013117 4.) 2.5…10 20 28 24 V DC 20029912 (179938 4.) 20029920 (365610 4.) C (CF C) 2 x 3/2-way solenoid valve Servo-controlled, with manual override Normally closed 1 5 1 3 4.0 300 1…10 2.) 12 20 24 V DC 186259 2.5…10 12 20 24 V DC 186260 1.) With integrated hot swap and/or non-return function, see chapter “2.2. Distinguishing features” on page 11 2.) Version with auxiliary pilot air 3.) If you have any questions about the compatibility of the va lve revision, please contact your Bürkert sales office. 4.) The Article no. can no longer be ordered. Order the superordinate set instead.
24 | 32Visit product website Solenoid valves Type 0460 Note: Further information about this product version can be found in chapter “1.3. Solenoid valves Type 0460” on page 7 Circuit function Orifice QNn value air 1.) Pressure range 2.) Switching times Nominal power Article no. Valve for 8640 REV1, 2 & 3 Opening Closing [mm] [l/min] [bar] [ms] [ms] [W] L (CF L) 5/3-way solenoid valve With manual override In middle position all ports locked 14 12 4 2 5 1 3 2.5 200 2.0…7.0 15 20 1 154184 N (CF N) 5/3-way solenoid valve With manual override In middle position ports 2 and 4 exhausted. 14 12 4 2 5 1 3 2.5 200 2.0…7.0 15 20 1 154185 Z (CF Z) 5/2-way solenoid valve Impulse version with 2 coils and manual override Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. 14 12 4 2 5 1 3 2.5 200 2.0…7.0 15 15 0.5 154183 1.) Measurement at + 20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure 2.) Pressure information: overpressure to atmospheric pressure
25 | 32Visit product website Solenoid valves Type 6526 and Type 6527 Note: Further information about this product version can be found in chapter “1.4. Solenoid valves Type 6526 and Type 6527” on page 8 Circuit function Orifice QNn- value 1.) air Pressure range 2.) Switching times Nominal power Voltage/ Frequency Article no. Valve for 8640 REV1, 2 & 3 Opening Closing [mm] [l/min] [bar] [ms] [ms] [W] [V/Hz] C (CF C) 3/2-way solenoid valve Servo-controlled, with manual override Normally closed 2(A) 1(P) 3(R) 6 700 1.0…10 1.) 20 12 2 24 V DC 156842 1.0…10 1.) 20 12 2 24 V DC 163028 2.0…10 20 12 2 24 V DC 156318 2.0…10 20 12 2 24 V DC 158944 2.0…8.0 20 17 1 24 V DC 156840 2.0…8.0 20 12 1 24 V DC 158947 D (CF D) 3/2-way solenoid valve Servo-controlled, with manual override Normally open 2(B) 1(P) 3(R) 6 700 1.0…10 1.) 20 12 2 24 V DC 163029 2.0…10 12 20 2 24 V DC 156320 2.0…10 20 12 2 24 V DC 158946 2.0…8.0 17 20 1 24 V DC 156841 H (CF H) 5/2-way solenoid valve Servo-controlled, with manual override Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. 4 2 5 1 3 6 700 1.0…10 1.) 20 12 2 24 V DC 156828 1.0…10 1.) 20 12 2 24 V DC 163030 2.0…10 20 12 2 24 V DC 156337 2.0…10 20 12 2 24 V DC 158942 2.0…8.0 20 17 1 24 V DC 156827 2.0…8.0 20 12 1 24 V DC 158943 1.) Measurement at + 20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure 2.) Pressure information: overpressure to atmospheric pressure
26 | 32Visit product website Solenoid valves Type 5470 Note: Further information about this product version can be found in chapter “1.5. Solenoid valve Type 5470” on page 9 Circuit function Orifice QNn- value 1.) air Service ports 4 and 2 Pressure range 2.) Nominal power Voltage/ Frequency Article no. Valve islands Article no. Valve blocks [mm] [l/min] [bar] [W] [V/Hz] C (CF C) 3/2-way solenoid valve Servo-controlled, with manual override Normally closed 2(A) 1(P) 3(R) 4 300 Plug-in coupling Ø 6 mm, below 2…8 1 24 V DC 132479 135203 2…10 2 24 V DC 133148 135204 2…10 3 110…120 DC – 132952 2…10 3 220…240 DC – 132953 D (CF D) 3/2-way solenoid valve Servo-controlled, with manual override Normally open 2(B) 1(P) 3(R) 4 300 Plug-in coupling Ø 6 mm, below 2…8 1 24 V DC 132481 136742 2…10 2 24 V DC 136741 136743 2…10 3 110…120 DC – 136744 2…10 3 220…240 DC – 136745 G (CF G) 4/2-way solenoid valve Servo-controlled 2(B) 4(A) 1(P) 3(R) 4 300 Plug-in coupling Ø 6 mm, front 2…8 1 24 V DC 132487 135205 2…10 2 24 V DC 133149 135206 2…10 3 110…120 DC – 132954 2…10 3 220…240 DC – 132955 4 300 Plug-in coupling Ø 6 mm, below 2…8 1 24 V DC 132489 135207 2…10 2 24 V DC 133150 135208 2…10 3 110…120 DC – 132956 2…10 3 220…240 DC – 132957 4 300 Plug-in coupling Ø 6 mm, front with throttle- check valve 2…8 1 24 V DC 132488 135209 2…10 2 24 V DC 133151 135210 2…10 3 110…120 DC – 133152 2…10 3 220…240 DC – 133153 4 300 Threaded port G ⅛, front 2…8 1 24 V DC 132483 135211 2…10 2 24 V DC 133157 135212 2…10 3 110…120 DC – 132958 2…10 3 220…240 DC – 132959 4 300 Threaded port G ⅛, front, with throttle- check valve 2…8 1 24 V DC 132484 135213 2…10 2 24 V DC 133159 135214 2…10 3 110…120 DC – 133160 2…10 3 220…240 DC – 133161 4 300 Tube connec tion SL6/4 mm, front 2…8 1 24 V DC 133162 135215 2…10 2 24 V DC 133163 135216 2…10 3 110…120 DC – 133164 2…10 3 220…240 DC – 133166 1.) Measurement at + 20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure 2.) Pressure information: overpressure to atmospheric pressure
27 | 32Visit product website 9.4. Ordering chart accessories Cover plate Note: If not all the valve connections in a basic valve unit module are used, then these connections should be covered by the appropriate cover plate to ensure full efficiency. Cover plate Article no. Cover plate for solenoid valves Type 6524/6525 (REV1) 650373 Cover plate for solenoid valves Type 6524/6525 (REV2) 661092 Cover plate for solenoid valves Type 6524 2x 3/2-way valve 661092 Cover plate for solenoid valves Type 0460 655069 Cover plate for solenoid valves Type 6526/6527 653765 Cover plate for solenoid valves Type 0461 657490 Blind plates AirLINE Quick Note: A blind plate is used to cover an existing flange for AirLINE Quick on the cabinet wall or on the cabinet floor. Description Article no. Blind plate AirLINE Quick, 4-fold 20057391 Blind plate AirLINE Quick, 8-fold 20057390 Blind plate AirLINE Quick, 12-fold 20057388 Blind plate AirLINE Quick, 16-fold 20057387 Blind plate AirLINE Quick (valve terminal with intermediate supply), 16-fold 20056955 Blind plate AirLINE Quick, 24-fold 20057392 Blind plate AirLINE Quick (valve terminal with intermediate supply), 24-fold 20057394 Bus Y-piece Note: For the bus Y-piece for PROFIBUS, a pre-assembled and a free-assembled connector must be used. Cover plates Description Article no. PROFIBUS Y-piece, M12, 5-pin, 21 mm 920625 RIO cable for bus extension Cable Article no. m cable 917498
28 | 32Visit product website 9.5. Ordering chart spare parts Spare parts SVVI for Type 8640, REV1, REV2 – Pneumatics 11 mm width per station Pos. Description Content Article no.
1 Spare valves see
“9.3. Ordering chart replacement valves” on page 23 – –
2 Cover plate
“9.4. Ordering chart accessories” on page 27 – –
3 Set of valve seals – –
Spare valve seals FM20 for Type 6524, 2 x 3/2-way solenoid valve 12 20016305 Spare valve seals FM15 for Type 6524, 3/2-way solenoid valve 12 20024333 Spare valve seats FM14 for Type 6525, 5/2-way solenoid valve 12 20024334 Spare valve seals FM16 for Type 0460 12 20024330
4 Sets of module seals – –
Spare module seals for Type MP11 4 20040779 5 Supply units o. r. o. r. 6 Base modules o. r. o. r.
7 Sets of electronic modules – –
8 AirLINE Quick spare parts
“9.4. Ordering chart accessories” on page 27 – – o. r. = on request 1 2
29 | 32Visit product website Spare parts SVVI for Type 8640, REV1, REV2 – Pneumatics 16 mm width per station Pos. Description Content Article no. “9.3. Ordering chart replacement valves” on page 23 – – “9.4. Ordering chart accessories” on page 27 – – Spare valve seals FM17 for Type 6526 and Type 6527 12 20016307 Spare valve seals FM19 for Type 0461 12 20024337 Spare module seals for Type MP12 4 20036699 5 Supply units o. r. o. r. 6 Base modules o. r. o. r. 7 Electronic modules o. r. o. r. o. r. = on request 1 2 1 2
30 | 32Visit product website Spare parts SVVI for Type 8640, REV3 – Pneumatics 11 mm width per station Pos. Description Content Article no. “9.3. Ordering chart replacement valves” on page 23 – – “9.4. Ordering chart accessories” on page 27 – – Spare valve seals FM20 for Type 6524, 2 x 3/2-way solenoid valve 12 20016305 Spare valve sealss FM24 for Type 6524 12 20024336 Spare valve seals FM16 for Type 0460 12 20024330 Spare module seals for Type MP16 4 20024339 5 Supply units o. r. o. r. Supply unit right for Type 8640, 11 mm, G ¼ 1 20040351 Supply unit left for Type 8640, 11 mm, G ¼ 1 20040352
6 Base modules – –
8640, 8644, 8647, 11 mm, 4-fold, D6, FM20 1 20040334 Base unit for Type 8640, 8644, 8647, 11 mm, 4-fold, D6, FM20, Hot Swap, RSV 1 20040335 Base unit for Type 8640, 8644, 8647, 11 mm, 4-fold, D¼, FM20 1 20040337 Base unit for Type 8640, 8644, 8647, 11 mm, 4-fold, D¼, FM20, Hot Swap, RSV 1 20040339 Base unit for Type 8640, 8644, 8647, 11 mm, 4-fold, D6, FM16 1 20040340 Base unit for Type 8640, 8644, 8647, 11 mm, 4-fold, D6, FM16, RSV 1 20040343 Base unit for Type 8640, 8644, 8647, 11 mm, 4-fold, D¼, FM16 1 20040344 Base unit for Type 8640, 8644, 8647, 11 mm, 4-fold, D¼, FM16, RSV 1 20040345
7 Electronic modules – –
Electrical base module for Type 8644, 11 mm, 2-fold, impulse valve 1 20040558 Electrical base module for Type 8644, 11 mm, 8-fold, impulse valve 1 20040559 Electrical base module for Type 8644, 11 mm, 2-fold, single valve 1 20040560 Electrical base module for Type 8644, 11 mm, 8-fold, single valve 1 20040561 Electrical base module for Type 8644, 11 mm, 2-fold, double valve 1 20040562 Electrical base module for Type 8644, 11 mm, 8-fold, double valve 1 20040563 “9.4. Ordering chart accessories” on page 27 – – o. r. = on request
31 | 32Visit product website
32 | 32Visit product website Spare parts SVVI for Type 8640, REV3 – Pneumatics 16 mm width per station Pos. Description Content Article no. “9.3. Ordering chart replacement valves” on page 23 – – “9.4. Ordering chart accessories” on page 27 – – Spare valve seals FM17 for Type 6526 and Type 6527 12 20016307 Spare module seals for type MP17 4 20016310
5 Supply units – –
Right supply unit for Type 8640, 16 mm, G ⅜ 1 20042796 Left supply unit for Type 8640, 16 mm, G ⅜ 1 20042793 6 Base modules o. r. o. r. Base unit for Type 8640, 16 mm, 4-fold, D8, FM17 1 20042790 Base unit for Type 8640, 16 mm, 4-fold, D8, FM17, RSV 1 20042792 7 Electronic modules o. r. o. r. o. r. = on request