Visit product website  DATA SHEET Type 2507  Cable plug, form B according to industry standard Type 2516  Cable plug, form C according to DIN EN 175301‑803 Type 2518  Cable plug, form A according to DIN EN 175301‑803 Type 2030  Pneumatically operated way diaphragm valve CLASSIC with plastic valve body Type 1087  Timer, form A according to DIN EN 175301‑803 Standard | EU | en | 2023 ‑ 09 ‑ 11 | 21 Servo-assisted 3/2-way Solenoid Valve for pneumatics

  • High flow-rate capacity Reduced power consumption Single or manifold mounting Standard, Ex mb, Ex eb mb and Ex ia versions Threaded port G ¼" and NPT ¼" The Type 6518 is a servo-assisted 3/2-way valve and the Type 6519 is a 5/2 or 5/3 way valve. Together, they form a product line. The valves can be used individually or in blocks. The valves work without a continuous air consump‑ tion and are used for the pneumatic control of double or single acting actua‑ tors. The use of high quality materials makes it possible to use these valves in the open air and under chemical atmospheres. The product line contains units with Ex-Approvals and NAMUR flange interface. Valves with circuit function C, D and H monostable are certified acc. IEC 61508 as SIL2. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 6518 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 22Visit product website  Table of contents 1. General technical data 3 Product versions 2.2. Ex mb und Ex eb mb version 2.3. Ex i version 3. Circuit functions 6 Materials 5. Dimensions 7 5.2. Standard version 3/2 way valve, circuit function C and D With plug form B or C With plug form A 5.3. Ex mb /eb mb version 3/2 way valve, circuit function C and D With moulded cable (3 m long) (Ex mb) With terminal box (Ex eb mb) 5.4. Ex i version 3/2 way valve, circuit function C 5.5. ATEX version cable coil and terminal box 6. Product design and assembly 12 7. Product accessories 13 7.2. Special tool to turn the terminal box 8. Ordering information 14 8.2. Bürkert product filter 8.3. Ordering chart standard version With plug form A With plug form B With plug form C 8.4. Ordering chart Ex mb version (with moulded cable) 8.5. Ordering chart Ex eb mb version (with terminal box) 8.6. Ordering chart Ex i version (310 Ohm) 8.7. Ordering chart accessories Cable plug Type 2513, form A according to DIN EN 175301 803 Cable plug Type 2518, form A according to DIN EN 175301 803 Cable plug Type 2507, form B according to industry standard Cable plug Type 2516, form C according to DIN EN 175301 803 Cable glands for ATEX/IECEx terminal box

3 | 22Visit product website  1. General technical data Product properties Dimensions Detailed information can be found in chapter “5. Dimensions” on page 7 Material Body Polyamide, reinforced glass-fibre Threaded bushing Brass (stainless steel on request) Seal NBR and PUR Manual override Standard Nominal diameter DN 8 Performance data Switching time 1.) Opening Pressure build ‑ up 0…10 % Closing Pressure reduction 100…90 Compressed air quality ISO 8573‑1:2010, class 7.4.4 2.) Nominal operating mode 100 % continuous operation Medium data Operating medium Neutral medium, e.g. lubricated or non lubricated compressed air Process/Port connection & communication Pneumatic connection Supply ports 1, 3, 5: Threaded G ¼, NPT ¼ Working ports 2, 4: Threaded G ¼, NPT ¼ Electrical connection Plug form A acc. to DIN EN 175301‑803 Plug form B acc. to DIN EN 175301‑803 Plug form C acc. to DIN EN 175301‑803 Product accessories Cable plug Type 2518 – form A (standard) Detailed information can be found in chapter “Cable plug Type 2518, form A accord- ing to DIN EN 175301 803” on page Cable plug Type 2507 – form B (standard) Detailed information can be found in chapter “Cable plug Type 2507, form B accord- ing to industry standard” on page 20 Cable plug Type 2516 – form C (standard) Detailed information can be found in chapter “Cable plug Type 2516, form C accord- ing to DIN EN 175301 803” on page Cable plug Type 2513 – form A for the EX area cat. 3 Detailed information can be found in chapter “Cable plug Type 2513, form A accord- ing to DIN EN 175301 803” on page Approvals and certificates Degree of protection IP65 with cable plug Environment and installation Installation position Any, preferably actuator face up 1.) Measurement at 6 bar and + 20 °C at the valve outlet 2.) To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium.

4 | 22Visit product website  2. Product versions 2.1. Standard version Note: For general technical data, see “1. General technical data” on page 3 Type 6518 is a pilot operated 3/2-way valve (normally closed or open). The valve width of 32 mm allows high flow rates. The valves can be used individually or in blocks. Product properties Coil size 24.5 mm Coil size 32 mm Switching time Opening 20 ms 20 ms Closing 40 ms 40 ms Weight 212 g 384 g Electrical data Operating voltage 24 V DC 24 V DC 24/ 110/ 230 V/ 50…60 Hz Power consumption Inrush – AC: 11 VA AC: 6/2 VA/W Hold DC: 1.7 W DC: 2 W Medium data Medium temperature - °C…+ °C - °C…+ Process/Port connection & communication Electrical connection Plug form B acc. to DIN EN 175301‑803 Plug form C acc. to DIN EN 175301‑803 Plug form A acc. to DIN EN 175301‑803 Environment and installation Ambient temperature - °C…+ °C - °C…+

5 | 22Visit product website  2.2. Ex mb- und Ex eb mb version Note: Ex mb (with moulded cable) or Ex eb mb (with terminal box) The maximum medium temperature may never exceed the permissible temperature class (T4 135 °C, T5 100 °C, T6 85 °C) minus 5K. The approval Ex m is achieved by the mounting of an approved push over coil. The cable connection and the cable are non detachable and sealed together with the valve. The valves can be used individually or in blocks. Product properties Switching time Opening 20 ms Closing 50 ms Weight 600 g Electrical data Operating voltage 24/ 110/ 230 V/UC Voltage tolerance + Medium data Medium temperature - °C…+ Process/Port connection & communication Electrical connection 3 m cable, moulded Terminal box (without fuse) Approvals and certificates Ignition protection class (ATEX and IECEx) Coil with cable EPS 18 ATEX 1232 X / IECEx EPS 18.0110X II 2G Ex mb IIC T5 Gb II 2D Ex mb IIIC T95 °C Db Coil with terminal box EPS 18 ATEX 1232 X / IECEx EPS 18.0110X II 2G Ex eb mb IIC T5 Gb II 2D Ex mb tb IIIC T95 °C Db Environment and installation Ambient temperature - °C…+

6 | 22Visit product website  2.3. Ex i version Note: The maximum medium temperature may never exceed the permissible temperature class (T4 135 °C, T5 100 °C, T6 85 °C) minus 5K. The units may only be used in potentially explosive atmospheres in the manner approved by the admis sion board, i.e. the permissible maximum electrical values must be observed. The valve is intended for operation on 24 V DC outputs via the intermediate switching of a corresponding intrinsically-safe operating resource (isolating module or barrier). The intrinsically-safe Type 6518 Ex i valve consist of an intrinsically-safe pilot control and a pneumatic amplifier. The diaphragm-controlled valve seats work with very low friction, ensuring reliable switching of the valve, even after long shut down periods. Product properties Switching time Opening 75 ms Closing 115 ms Weight 580 g Electrical data Function values for switching function valve At + °C At + Minimum switching current 29 mA 29 mA Nominal resistance coil 310 Ω 360 Ω Minimum terminal voltage 9.0 V 10.4 V Conformity specifications Ui 35 V Ii 0.9 A Pi 1.1 W Medium data Medium temperature - °C…+ Process/Port connection & communication Electrical connection Cable plug Type 2518, form A acc. to DIN EN 175301 803. Detailed information can be found in chapter “Cable plug Type 2518, form A according to DIN EN 175301 803” on page Approvals and certificates Approvals EPS 18 ATEX 1 088 / IECEx EPS 18.0038 X II 2G Ex ia IIC T6 Gb II 2D Ex ia IIIC T135 °C Db Environment and installation Ambient temperature - °C…+ 3. Circuit functions Circuit functions Description 2(A) 1(P) 3(R) Circuit function C (CF C) way solenoid valve Servo controlled Normally closed 2(A) 1(P) 3(R) Circuit function C (CF C) way solenoid valve Servo controlled, with manual override Normally closed 2(B) 1(P) 3(R) Circuit function D (CF D) way solenoid valve Servo controlled, with manual override Normally open

7 | 22Visit product website  4. Materials 4.1. Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check 5. Dimensions 5.1. Pneumatic module Type MP07 Note: Dimensions in mm n = no. of valves, maximum 12 Block mounting on wall or with DIN rail 50022 or 50023 Valve mounting on the pneumatic modules Type MP07 by means of included M4 screws 59 + (n x 33) 5/3, 5/3 - Impulse G 1/8 NPT 1/8 n x 33 87 + (n x 33) 110 + (n x 33) G 1/4 NPT 1/4 G 1/2 NPT 1/2 115 108 102.5 57.5 120 182 101.5 249 124.8 100 ø 5.5

8 | 22Visit product website  5.2. Standard version 3/2-way valve, circuit function C and D Note: Dimensions in mm With plug form B or C M7 x 0.75 SW11 24.6 ø 4.3 7.9 - 4.2 deep 13,5 G1/4 / NPT1/4 25.5 112.7 6.1 34.5 25.5 74.2 ø 4.3 ø 8 - 4.3 deep 34.5 16.4 2805 G1/4 / NPT1/4 ø 3 - 3 deep 1305 With plug form A AF14 ø 4.3 7.9 - 4.2 deep 13.5 G1/4 / NPT1/4 25.5 11.2 138.75 G1/8 34.5 25.5 69.65 ø 8 - 4.3 deep ø 4.3 20.5 G1/4 / NPT1/4 ø 3 - 3 deep 28.5 13.5

9 | 22Visit product website  5.3. Ex mb-/eb mb- version 3/2-way valve, circuit function C and D With moulded cable (3 m long) (Ex mb) Note: Dimensions in mm D ø 6.2 C 25.5 69.65 ø 8 - 4.3 deep ø 4.3 B min. R25 Length according to order AF14 25.5 138.75 ø 4.3 7.9 - 4.2 deep 13.5 69.65 G1/4 / NPT1/4 34.5 G1/8 10.9 A 28.5 ø 3 - 3 deep G1/4 / NPT1/4 13.5 With terminal box (Ex eb mb) Note: The dimensions of the housing are identical to the version with molded cable. For the coil dimensions, see chapter “5.5. ATEX version cable coil and terminal box” on page 11

10 | 22Visit product website  5.4. Ex i version 3/2-way valve, circuit function C Note: Dimensions in mm G1/8 AF14 A 11.2 145.75 25.5 G1/4 / NPT1/4 ø 4.3 7.9 - 4.2 deep 13.5 34.5 25.5 69.65 ø 8 - 4.3 deep ø 4.3 C B G1/4 / NPT1/4 ø 3 - 3 deep 28.5 13.5

11 | 22Visit product website  5.5. ATEX version cable coil and terminal box Note: Dimensions in mm 6.2 to order B C D min R25 Length according A 41.3 84.3

29.7 R84

E F M20x1.5 B A Coil size A B C D E F 5 32 20.5 46 66.8 99.8 174.7 6 40 23.5 52 74.8 102.8 177.7

12 | 22Visit product website  6. Product design and assembly 6.1. Block construction Note: Single modules or pre mounted blocks are available. No. Element

1 Connector module left

2 Basic module 3

3 intermediate supply module: supply channel pushed through for additional pressure supply or Connector module, right: supply channel closed off, there by several operational pressures possible in a single block

4 Basic module 2

5 Connector module right

6 Supply port: 3(R)

7 Supply port: 1(P)

8 Supply port: 5(S)

9 Covering plate for 3/2-way valve (to cover unused connections)

Note: Valves with Ex i coil or Ex versions with terminal boxes are not suitable for block mounting. Unit Version Article no.

1 Connector module right, G ½ 635331 

1 Basic module 2-fold universal (for 3/2-, 5/2- and 5/3-way) 635319 

1 Basic module 3-fold universal (for 3/2-, 5/2- and 5/3-way) 635343 

1 Connector module left, G ½ 635324 

5 Valves 6518 132475 

Version Article no. Connector module right, G ½ 635331  Intermediate supply module 637505  Basic module 2-fold universal (for 3/2-, 5/2- and 5/3-way) 635319  Basic module 3-fold universal (for 3/2-, 5/2- and 5/3-way) 635343  Connector module left, G ½ 635324  Covering plate for 5/2-way and 5/3-way (to cover unused valve positions) 635335  Covering plate for 3/2-way (to cover unused connections) 635337 

13 | 22Visit product website  7. Product accessories 7.1. Cable glands for ATEX/IECEx terminal box Note: A cable gland in polyamide version is included in the delivery. A nickel plated brass version can be ordered at a surcharge, see “Cable glands for ATEX/IECEx terminal box” on page Description Ex approvals Dimensions Certification Identification Ex cable gland, Brass, nickel-plated, 6…13 mm PTB 04 ATEX 1112 X, IECEx PTB 13.0027X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68 TL 29…37 mm L 6 mm D 20 mm SW 24 mm E 27 mm Ex cable gland, Polyamide, 7…13 mm PTB 13 ATEX 1015 X, IECEx PTB 13.0034X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68 TL 36…45 mm L 10 mm D 20 mm SW 24 mm E 28 mm 7.2. Special tool to turn the terminal box Note: This special tool is not supplied with the valve, see “Cable glands for ATEX/IECEx terminal box” on page 21 Description Components of the set Set SC02 AC10

  • Special wrench Service manual

14 | 22Visit product website  8. Ordering information 8.1. Bürkert eShop Bürkert eShop – Easy ordering and fast delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 8.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter

15 | 22Visit product website  8.3. Ordering chart standard version With plug form A Note: Please note that the cable plug must be ordered separately. See “Cable plug Type 2513, form A according to DIN EN 175301 803” on page or separate data sheet for Type 2513 See “Cable plug Type 2518, form A according to DIN EN 175301 803” on page or separate data sheet for Type 2518 Further variants without manual override available on request. Circuit function Ori- fice Seal material Body QNn- value air1) Pressure range2) Electrical connection Nominal power Voltage/ Frequency Article no. [mm] [l/min] [bar] [W] [V/Hz] G ¼ NPT ¼ CF C way solenoid valve Servo controlled, with manual override Normally closed 2(A) 1(P) 3(R)

8.0 NBR and

(Polyamide) 1300 2…10 Form A 2 024/DC 132457  132725  024/50…60 132458  o. r. 110/50…60 132459  o. r. 230/50…60 132460  o. r. CF D way solenoid valve Servo controlled, with manual override Normally open 2(B) 1(P) 3(R) (Polyamide) 1300 2…10 Form A 2 024/DC 132461  o. r. 024/50…60 132462  o. r. 110/50…60 132463  o. r. 230/50…60 132464  o. r. 1.) Measurement at 6 bar and + 20 °C at valve inlet and 1 bar pressure difference 2.) Pressure data: Overpressure to atmospheric pressure o. r. on request

16 | 22Visit product website  With plug form B Note: Please note that the cable plug must be ordered separately. See “Cable plug Type 2507, form B according to industry standard” on page 20 or separate data sheet for Type 2507 Further variants without manual override available on request. Circuit function Ori- fice Seal material Body QNn- value air1) Pressure range2) Electrical connection Nominal power Voltage/ Frequency Article no. [mm] [l/min] [bar] [W] [V/Hz] G ¼ NPT ¼ CF C way solenoid valve Servo controlled, with manual override Normally closed 2(A) 1(P) 3(R) (Polyamide) 1300 2…10 Form B 1.7 024/DC 20053701  20053702  024/50 o. r. o. r. 024/60 o. r. o. r. 110/50 o. r. o. r. 120/60 o. r. o. r. 230/50 o. r. o. r. 240/60 o. r. o. r. CF D way solenoid valve Servo controlled, with manual override Normally open 2(B) 1(P) 3(R) (Polyamide) 024/50 o. r. o. r. 024/60 o. r. o. r. 110/50 o. r. o. r. 120/60 o. r. o. r. 230/50 o. r. o. r. 240/60 o. r. o. r. 1.) Measurement at 6 bar and + 20 °C at valve inlet and 1 bar pressure difference 2.) Pressure data: Overpressure to atmospheric pressure o. r. on request

17 | 22Visit product website  With plug form C Note: Please note that the cable plug must be ordered separately. See “Cable plug Type 2516, form C according to DIN EN 175301 803” on page or separate data sheet for Type 2516 Further variants without manual override available on request. Circuit function Ori- fice Seal material Body QNn- value air1) Pressure range2) Electrical connection Nominal power Voltage/ Frequency Article no. [mm] [l/min] [bar] [W] [V/Hz] G ¼ NPT ¼ CF C way solenoid valve Servo controlled, with manual override Normally closed 2(A) 1(P) 3(R) (Polyamide) 1300 2…10 Form C 1.7 024/DC 20053699  20053700  024/50 o. r. o. r. 024/60 o. r. o. r. 110/50 o. r. o. r. 120/60 o. r. o. r. 230/50 o. r. o. r. 240/60 o. r. o. r. CF D way solenoid valve Servo controlled, with manual override Normally open 2(B) 1(P) 3(R) (Polyamide) 024/50 o. r. o. r. 024/60 o. r. o. r. 110/50 o. r. o. r. 120/60 o. r. o. r. 230/50 o. r. o. r. 240/60 o. r. o. r. 1.) Measurement at 6 bar and + 20 °C at valve inlet and 1 bar pressure difference 2.) Pressure data: Overpressure to atmospheric pressure o. r. on request 8.4. Ordering chart Ex mb version (with moulded cable) Note: Further variants without manual override available on request. Circuit function Orifice Seal material Body QNn- value air1) Pressure range2) Nominal power Voltage/ Frequency Article no. [mm] [l/min] [bar] [W] [V/Hz] G ¼ NPT ¼ CF C way solenoid valve Servo controlled, with manual override Normally closed 2(A) 1(P) 3(R) (Polyamide) 1300 2…10 3 024/UC 350443  o. r. 110/UC 350449  o. r. 230/UC 350451  o. r. CF D way solenoid valve Servo controlled, with manual override Normally open 2(B) 1(P) 3(R) (Polyamide) 1300 2…10 3 024/UC 350452  o. r. 110/UC o. r. o. r. 230/UC o. r. o. r. 1.) Measurement at 6 bar and + 20 °C at valve inlet and 1 bar pressure difference 2.) Pressure data: Overpressure to atmospheric pressure o. r. on request

18 | 22Visit product website  8.5. Ordering chart Ex eb mb version (with terminal box) Note: Further variants without manual override available on request. Circuit function Orifice Seal material Body QNn- value air1) Pressure range2) Nominal power Voltage/ Frequency Article no. [mm] [l/min] [bar] [W] [V/Hz] G ¼ NPT ¼ CF C way solenoid valve Servo controlled, with manual override Normally closed 2(A) 1(P) 3(R) (Polyamide) 1300 2…10 3 024/UC 350446  o. r. 110/UC 350450  o. r. 230/UC 368752  o. r. CF D way solenoid valve Servo controlled, with manual override Normally open 2(B) 1(P) 3(R) (Polyamide) 1300 2…10 3 024/UC o. r. o. r. 110/UC 20009771  o. r. 230/UC 20015790  o. r. 1.) Measurement at 6 bar and + 20 °C at valve inlet and 1 bar pressure difference 2.) Pressure data: Overpressure to atmospheric pressure o. r. on request 8.6. Ordering chart Ex i version (310 Ohm) Note: Please note that the cable plug must be ordered separately, see “Cable plug Type 2518, form A according to DIN EN 175301 803” on page or separate data sheet for Type 2518 Further variants with manual override available on request. Further variants with 481 Ohm available on request. Circuit function Orifice Seal material Body QNn- value air1) Pressure range2) Body material pilot valve Material threaded bushing Material threaded bushing Article no. [mm] [l/min] [bar] G ¼ NPT ¼ CF C way solenoid valve Servo controlled Normally closed 2(A) 1(P) 3(R) (Polyamide) 1300 2…10 Stainless steel 1.4305 Stainless steel 20000908  20000931  Brass, nickel plated 20000913  o. r. 1.) Measurement at 6 bar and + 20 °C at valve inlet and 1 bar pressure difference 2.) Pressure data: Overpressure to atmospheric pressure o. r. on request

19 | 22Visit product website  8.7. Ordering chart accessories Cable plug Type 2513, form A according to DIN EN 175301 - 803 Note: Cable plug Type 2513 meets the requirements of ATEX category 3 GD when assembled with a Bürkert solenoid valve. For more information on the cable plug, see data sheet Type 2513 Cable plug Circuit diagram Cable length [mm] Article no. BN BU GNYE 12000 260893  5000 260892  3000 260891  300 260890  Cable plug Type 2518, form A according to DIN EN 175301 803 Note: For further versions see data sheet Type 2518 Cable plug Dimensions Version Voltage Article no. ca. 51 35.7 3.5 1.5 29.2 Ø 19 29.2 Without circuitry (AC/DC) 0…250 V AC/DC 314802  With LED (AC/DC) 12…24 V AC/DC 314812  With LED and varistor (AC/DC) 12…24 V AC/DC 314820  With rectifier, LED and varistor 12…24 V AC/DC 314816 

20 | 22Visit product website  Cable plug Type 2507, form B according to industry standard Note: Delivery of cable plug includes a flat seal and a fixing screw. For further versions see data sheet Type 2507 Cable plug Dimensions Version Voltage Article no. ~51 32 5.5 0-1 20.8 28.6 40.6 10 Ø 18 8.5 Without circuitry (standard) 2…250 V AC/DC 423845  With LED 24 V AC/DC 423849  With LED and free wheeling diode 12…24 V AC/DC 423851  With rectifier, LED and varistor 12…24 V AC/DC 423853  Cable plug Type 2516, form C according to DIN EN 175301 803 Note: Delivery of cable plug includes a flat seal and a fixing screw. For further versions see data sheet Type 2516 Cable plug Dimensions Version Voltage Article no. 15.8 28 approx. 10 Ø 15 M2.5 (1.5) 15.8 (16.8)max. 3.4 -1 3.6 -1 Without circuitry 0…250 V AC/DC 303141  With LED 12…24 V AC/DC 303145  With LED and varistor 12…24 V AC/DC 303148  With rectifier, LED and varistor 12…24 V AC/DC 303142 

21 | 22Visit product website  Cable glands for ATEX/IECEx terminal box Note: A cable gland in polyamide version is included in the delivery. A nickel plated brass version can be ordered at surcharge. For more information on Ex cable glands, see “7.1. Cable glands for ATEX/IECEx terminal box” on page 13 For more information on Special wrench see “7.2. Special tool to turn the terminal box” on page 13 Description Article no. Ex cable gland, brass, nickelplated, 6…13 mm 1.) 773278  Ex cable gland, polyamide, 7…13 mm 1.) 773277  Set SC02 AC10: Special wrench 2.) incl. service manual 293488  1.) Cable diameter 2.) Not included in the scope of delivery of the valve

Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -