SBE320 APP | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 9
Technical content
- 115 - All Data Subject To Change Without Notice www.andersonpower.com SBE® 320 / SBX® 350 ORDERING INFORMATION SBE® 320 / SBX® 350 Connectors Up to 550 Amps [ 200.0 ] 7.88 [ 33.3 ] 1.31 [ 61.9 ] 2.44 [ 28.6 ] 1.13 [ 15.9 ] 0.63 [ 83.4 ] 3.28 [ 125.4 ] 4.94 Ø [ 6.7 ] 0.27 Top View Mated Length SBE® and SBX® connectors can integrate up to 8 auxiliary power / signal contacts along with the two primary power circuits. Sequencing within auxiliary positions is possible using the 4 pin lengths available in the 1x4 auxiliary connector. SBE ® and SBX® offer touch safe housings.
- Silver Plated Wire Contacts up to 350 mcm (185 mm²) Allows low resistance UL rated currents up to 550 amps per pole
- Up to 8 Auxiliaries Enables intelligent power switching, CAN and interlock loop circuitry, as well as power up to 20 amps per pole. Auxiliaries are all Last-mate/ First-break relative to power contacts. SBE ® 320 / SBX® 350 Housings The largest size of SBE®, X, O style housing. SBE® housings are molded from a chemical resistant PBT. SBX® housings are molded from PC. SBE® 320 and SBX® 350 housings of the same Voltage Color-Code cannot be mated. SBX® 350 housings do not meet EN1175-1 requirements for industrial trucks.
Description
SBE® 320 Part Numbers SBX® 350 Part Numbers Minimum Quantity 100 100 Yellow 2-8171G6 E6362 2-7249G6 6362 Orange 2-8171G7 E6339 2-7249G7 6339 Red 2-8171G3 E6352 2-7249G3 6352 Gray 2-8171G1 E6350 2-7249G1 6350 Blue 2-8171G2 E6351 2-7249G2 6351 Green 2-8171G4 E6353 2-7249G4 6353 Black 2-8171G5 E6361 2-7249G5 6361 Brown 2-8171G8 E6336 N/A N/A Purple 2-8171G9 E6349 N/A N/A SBE® 320 / SBX® 350 Silver Plated Primary Power Wire Contacts Silver plated contacts offer superior electrical performance and durability up to 10,000 mating cycles. See reducing bushings in accessory section for smaller wires. Dimensions A - - B - - C - - D - A WG mm² Loose Piece Part Numbers inches mm inches mm inches mm inches mm Minimum Quantity 200 150 300/350 mcm 150 6358-BK 6358 * 3.03 76.96 0.88 22.20 0.75 19.05 1.25 31.80 120 6356-BK 6356 * 3.10 78.74 0.75 19.05 0.64 16.26 1.25 31.80 6355-BK 6355 3.10 78.74 0.70 17.78 0.58 14.73 1.25 31.80 6354-BK 6354 3.10 78.74 0.64 16.26 0.49 12.45 1.25 31.80 6394-BK 6394 3.10 78.74 0.51 12.95 0.38 9.50 1.25 31.80 * Sold as pairs. 2 parts shipped for every 1 part ordered. SBE® 320 DIN Standard Silver Plated Primary Power Wire Contacts Crimp barrel O.D. are compliant with DIN standard tooling. Will also fit into SBX® 350 housings. Not recommended for cross mating with above typical contacts for SBE® & SBX®. Dimensions Loose Piece A - - B - - C - - D - A WG mm² Part Numbers inches mm inches mm inches mm inches mm Minimum Quantity 200 1341G3-BK 1341G3 2.89 73.41 0.78 19.81 0.59 14.99 0.94 23.88 1341G2-BK 1341G2 2.74 69.60 0.68 17.27 0.51 12.95 0.79 20.07 1341G1-BK 1341G1 2.65 67.31 0.57 14.48 0.43 10.92 0.79 20.07 * Sold as pairs. 2 parts shipped for every 1 part ordered. [ 20.6 ] 0.81 B A D C [ 20.6 ] 0.81 B A D C SBE® 320 / SBX® 350
- 116 - All Data Subject To Change Without Noticewww.andersonpower.com SBE® 320 / SBX® 350 CONNECTOR TEMPERATURE CHARTS - Temperature rise charts are based on a 25°C ambient temperature. SBE® 320 / SBX® 350 Derating vs. Ambient Temperature Ambient Temperature (°C) 100 125 50 150 250 350 450 550 Amperes Applied
350 MCM
300 MCM
4/0 AWG - 120mm² 3/0 AWG 2/0 AWG 1/0 AWG SBE® 320 / SBX® 350 Temperature Rise at Constant Current Temperature Rise Above Ambient (°C) 0 50 100 150 200250300350400450 550500 Amperes Applied 4/0 AWG - 120mm² 3/0 AWG 2/0 AWG 1/0 AWG SBE® 320 / SBX® 350 SBE® 320 / SBX® 350 CONNECTOR SPECIFICATIONS ELECTRICAL SBX® & SBE® SBE® Only Current Rating Amperes 1 UL CSA EN1175-1 Primary Power (350 MCM) 550 350 320 Powerpole® Auxiliary (12 AWG) 20 20 N/A 1x4 Auxiliary (12 AWG) 20 20 N/A PPMX (20 AWG) 5 5 N/A Voltage Rating AC/DC Primary Power (350 MCM) 600 150 4 Powerpole® Auxiliary (12 AWG) 600 150 1x4 Auxiliary (12 AWG) 600 N/A PPMX (20 AWG) 600 N/A Dielectric Withstanding Voltage Volts AC 2,200 * Average Mated Contact Resistance milliohms 2 1/2 " 350 MCM 0.05 MATERIALS Housings SBX® and Powerpole® Auxiliary Housings Polycarbonate SBE®, PPMX and 1x4 Auxiliary Housings Polycarbonate / PBT blend Housing Flammability Rating UL IEC (SBE® Only) SBX® / SBE® 94 V-0 960°C (GWFI) 850°C (GWIT) Contact Materials Power Contacts Au Plated Copper Powerpole® Auxiliary Au or Sn - Copper Alloy 1x4 Auxiliary Contacts Pin Au Over NI - Copper Allow Socket Au Over NI - BeCu Socket Body Sn Over Ni, Copper Alloy Retention Clip Stainless Steel PPMX Contacts Gold Plated Copper Alloy * Not UL rated Contact Terminations 3 - Crimp or Hand Solder Current - Temperature Derating per IEC 60512-5-2 Test 5B
- 117 - All Data Subject To Change Without Notice www.andersonpower.com SBE® 320 / SBX® 350 MECHANICAL Wire Size Range AWG mm² Power Contacts 1/0 to 350 MCM 53.5 to 185 Auxiliary Contacts 24 to 10 AWG 0.25 to 5.3 Max Wire Insulation Diameter in mm Power Contact 0.82 * 20.8 * Powerpole® Auxiliary 0.175 4.45 1x4 Auxiliary 0.14 3.6 PPMX Auxiliary 0.09 2.29 Operating Temperature 2 °F °C SBX® Housing with all Auxiliary -4 to 221 -20 to -105 SBE® Housing -40 to 221 -40 to 105 SBX® Housing with Powerpole® Auxiliary Housings -4 to 221 -20 to -105 SBE® Housing with 1x4 and PPMX Auxiliaries -40 to 221 -40 to 105 Mating Cycles Silver / Tin Gold Power Contacts 10,000 N/A Powerpole® Auxiliary 10,000 / 1500 N/A 1x4 Auxiliary N/A 10,000 PPMX Auxiliary N/A 5,000 Average Mating LBF N Main Connector Housing 37 165 Per Powerpole® Connector 5 22 Per 1x4 Auxiliary Housing 0.7 3 Per PPMX Housing 4.5 20 Min Contact / Spring Retention Force 150 667 Powerpole® Housing 25 111 1x4 Auxiliary Housing 10 44.5 PPMX Housing 12 53 Min Contact / Spring Retention Force 150 667 Powerpole ® Housing 25 111 1x4 Auxiliary Housing 10 44.5 PPMX Housing 12 53 1x4 Auxiliary Housing 10 44.5 PPMX Housing 12 53 Note 1: See IEC60664-1 for working voltage Note 2: Amp ratings are stated per position and based on all positions being fully loaded 1 - Based on 195°C rated or better cable of the largest size. Properly calibrated APP® recommended tooling and 25°C ambient temperature 2 - limited by thermal properties of the connector plastic housing 3 - USE APP® recommended tooling only. Alternate tools may adversely affect performance of our connectors along with UL and CSA recognition 4 - Voltage capability of SBE® housings is identical to SBX® but derated to meet EN1175-1 requirements * Refer to assembly instructions for using 300 MCM and 350 MCM wire IEC INFORMATION PROTECTION Touch Safety Main Connector Housing IEC 60950 SBE® 320 Only Pass IEC 60529 SBE® 320 & SBX® 350 IP20 Connector Series Configurations Creepage / Clearance per IEC 60950-1 Material Group SBE® 320 Unmated 5.6 mm IIIa Mated 24.7 mm ATTRIBUTES SBE® 320 AMP Rating AC/DC 320 Amp Voltage Rating AC/DC (Steady State)
600 V AC/DC (Operational)
275 Amp / 10 Cycles
(Breaking Capacity)
220 VDC
Wire Size Tested 120 mm² Contact Series Tested 6356 Climatic Testing (Cold, Heat & MFG) IEC 60512 Test -11j, 11i & 11g Cycle Life IEC 60512 Test 9a - 5,000 Cycles Mechanical Strength Impact IEC 60512-5 @ 29.5 Inches Dropped 8 Times Temperature Range -20°C to 105°C -4°F to 221°F
- 118 - All Data Subject To Change Without Noticewww.andersonpower.com SBE® 320 / SBX® 350 ACCESSORIES Cable Clamps Durable metal clamps adapt to a wide range of cable sizes. Cable clamp kit includes clamp top and bottom as well as the hardware bag. Cable Size Min / Max Min / Max
Inches O.D. mm O.D. Part Number Minimum Quantity Cable Clamp Kit 0.85 to 0.67 21.6 to 17.1 1G2 Handles * Handles are made out of durable PC plastic. Hardware to attach to connector body included in kits. , Gray 3-5074P1 Handle Only , Red 3-5074P3 Handle Only , Black 3-5074P5 Hardware Bag 106G7 Torque value 50 (in - lbs) / 5.6 (Nm) NOTE: For assembly of clamps to housing only Powerpole® Auxiliary Powerpole® auxiliary connectors are rated up to 30 amps 600 volts and can be used for auxiliary power, control or sensing. The auxiliary kit includes (1) each black and red standard Powerpole® housing, (2) Contacts, (2) Zip Cable Straps, and (2) Retaining Pins. (1) Retaining Clip can be substituted for (2) Retaining Pins. Powerpole® Auxiliary Kit 16 to 12 AWG Contact - 6305G1 Powerpole® Auxiliary Kit 20 to 16 AWG Contact - 6310G1 Black Powerpole® Housing 1327G6 - Red Powerpole® Housing 1327 - 16 to 12 AWG Contact 1331 20 to 16 AWG Contact 1332 NOTE: Finger proof PP15/45 housings should not be used for auxiliary contacts. 1x4 Auxiliary Connector The unique 1x4 auxiliary connector allows up to 4 auxiliary circuits up to 20 amps 150 volts each in SBE ®, SBO®, & SBX® housings. The genderless design holds two each of the gold plated pin & socket contacts. This innovation allows the very durable and cost effective design of SBE ®,O, X connectors to substitute for DIN 43589-1 applications where 4 auxiliary contacts are required. Multiple pin lengths allow the further benefit of sequencing between circuits. (2) Retaining Pins or (1) Retaining Clip is required to hold the auxiliary housing in place. Auxiliary Kits include (1) Auxiliary Housing, (2) Standard Length Pin Contacts, (2) Socket Contacts, (2) Retaining Pins and (1) Retaining Clip. mm² Part Numbers Minimum Quantity 1,000 250 1x4 Auxiliary Kit 440G3 1x4 Auxiliary Kit 16 to 14 1.5 to 2.5 440G1 1x4 Auxiliary Kit 20 to 16 0.75 to 1.5 440G2 1x4 Auxiliary Housing Contacts Sold Separately 3-5956P1 444G1 The given wire O.D. information is an estimate. Cable clamps should be evaluated for performance with the actual wire to be used. [ 8.4 ] 0.33 [ 10.9 ] 0.43 [ 3.8 ] 0.15 [ 41.3 ] 1.62 Socket Locations SBE® 320 / SBX® 350
- 119 - All Data Subject To Change Without Notice www.andersonpower.com [ 1.60 ] Ø 0.06 Retention Clip L Pin Contacts for 1x4 Auxiliary Connector Gold plated contacts are available in 4 lengths to allow sequencing of circuits.
A WG mm² Part Numbers Minimum Quantity 500 Standard Length 7.7 mm 2.5 PM16P12S30 PM16P12S30-50 16 to 14 1.0 to 1.5 PM16P1416S30 PM16P1416S30-50 20 to 16 0.75 to 1.0 PM16P1620S30 PM16P1620S30-50 24 to 20 0.50 to 0.75 PM16P2024S30 PM16P2024S30-50 Pre-Mate 9.3 mm 2.5 PM16P12A30 PM16P12A30-50 16 to 14 1.0 to 1.5 PM16P1416A30 PM16P1416A30-50 20 to 16 0.75 to 1.0 PM16P1620A30 PM16P1620A30-50 24 to 20 0.50 to 0.75 PM16P2024A30 PM16P2024A30-50 Post-Mate 6.4 mm 2.5 PM16P12C30 PM16P12C30-50 16 to 14 1.0 to 1.5 PM16P1416C30 PM16P1416C30-50 20 to 16 0.75 to 1.0 PM16P1620C30 PM16P1620C30-50 24 to 20 0.50 to 0.75 PM16P2024C30 PM16P2024C30-50 Socket Contacts for 1x4 Auxiliary Connector Selectively gold plated contacts offer low resistance and durability up to 10,000 mating cycles. mm² Part Numbers Minimum Quantity 500 Socket Contact 2.5 PM16S12S32 PM16S12S32-50 16 to 14 1.0 to 1.5 PM16S1416S32 PM16S1416S32-50 20 to 16 0.75 to 1.0 PM16S1620S32 PM16S1620S32-50 24 to 20 0.50 to 0.75 PM16S2024S32 PM16S2024S32-50 SBE® Air Tubes Air tubes fit into SBE® housings to allow electrolyte circulation while charging the battery. Genderless tube design allows the same part to be used on both sides. (2) Retaining Pins or (1) Retaining Clip is required to hold the air tube in place. Retaining Pins are included in Air Tube Kit. Tube Kit, Black 6396G1 Air Tube Only 3-5798P1 Auxiliary Pin Contact Lengths - L - - L1 - in. mm in. mm SBE® 320 / SBX® 350 Auxiliary Socket Contacts Crimp Barrel ID Wire Gauge in. mm. 24 to 20 0.04 1.1 20 to 16 0.07 1.7 16 to 14 0.08 2.1 12 0.10 2.6 Socket Insert [ 19.6 ] 0.77 [ 2.6 ] 0.10Retention Clip ID
- 120 - All Data Subject To Change Without Noticewww.andersonpower.com 4803G3 4802G3 4827G6 Socket Locations A B PPMX Auxiliary Connector The PPMX auxiliary connector allows up to 8 auxiliary circuits to be used in the SBE®, SBO®, & SBX® housings. There are 4 auxiliary circuits per PPMX connector and two PPMX housings fit into the auxiliary port in the main connector housing. Rated up to 7 amps 300 volts per contact, the genderless design holds two each gold plated pin & socket contacts. This innovation allows the very durable and cost effective design of SBE ®, O, X connectors to be used for applications requiring up to 8 battery monitoring or equipment vehicle communication circuits. (2) Retaining Pins or (1) Retaining Clip is required to hold the auxiliary housing in place. Auxiliary Kits includes: (1) Auxiliary Housing, (2) Pin Contacts, and (2) Socket Contacts.
mm² Part Numbers Minimum Quantity 1,000 100 PPMX Auxiliary Kit 24 to 20 0.50 to 0.25 4850G6 1x4 Auxiliary Housing Contacts Sold Separately 4827G6-BK 4827G6 * No extraction tool required for contact removal. Pin & Socket Contacts for PPMX Auxiliary Connector Gold plated contacts are ideal for signal or low power use with durability up to 5,000 mating cycles. A WG mm² Part Numbers Minimum Quantity 2,000 50 Pin Contacts 24 to 20 0.50 to 0.25 4803G3-BK 4803G3 Socket Contacts 24 to 20 0.50 to 0.25 4802G3-BK 4802G3 Retaining Clip Retaining clips can be used in place of two retaining pins to hold auxiliary connectors or air tubes. Allows easier removal of auxiliary modules. De scription Part Number Minimum Quantity 100 For SBE® 320 & SBX® 350 2-8675P1 Retaining Pins Retaining pins are used to hold accessories in the auxiliary port in SBE®, SBO®, & SBX® housings. Dimension “B” is +/- 0.015 in or 0.38 mm. Dimensions A - - B - Description Part Number inches mm inches mm Minimum Quantity 1,000 SBE® 320 / SBX® 350
- 121 - All Data Subject To Change Without Notice www.andersonpower.com SBE® 320 / SBX® 350 Zip Cable Straps Zip cable straps are used to secure auxiliary wires to the side of the main power cables.
Minimum Quantity 1,000 White H1835P3 Manual Release - Battery Side * Works with the Charger / Truck side to ease mating and unmating connectors.
- T orque value 50 (in - lbs) / 5.6 (Nm) NOTE: For assembly of bracket to housing only Manual Release - Charger/ Truck Side * Works with the Battery side to ease mating and unmating connectors.
Torque value 50 (in lbs) / 5.6 (Nm) NOTE: For assembly of bracket to housing only Use cable ties to secure auxiliary contact leads to one of the main cables. 993G1 111961P1 994G1 B00511G4
- 122 - All Data Subject To Change Without Noticewww.andersonpower.com SBE® 320 / SBX® 350 Reducing Bushings: for Use with Contact Part Number 6354 and Bushing Part Number 5918 Use with contact part number 6354-BK and bushing part number 5918-BK to allow a smaller wire to be used with the connector. Electrical capability is derated with smaller wire. Bushing Part Number 5918 Dimensions Barrel Size W ire Size - ID - A WG mm² A WG mm² Part Numbers inches mm Minimum Quantity 1,500 1,000 500 100 1/0 53.5 1 42.4 5687-BK 5687 0.39 9.91 1/0 53.5 2 33.6 5690-BK 5690 0.34 8.64 1/0 53.5 4 21.2 5693-BK 5693 0.27 6.86 1/0 53.5 6 13.3 5663-BK 5663 0.22 5.59 1/0 53.5 10 to 8 5.3 to 8.4 5648-BK 5648 0.19 4.83 Reducing Bushings: for Use with Contact Part Number 6354 Use with contact part number 6354-BK to allow a smaller wire to be used with the connector. Electrical capability is derated with smaller wire. Contact Barrel Size / Wire Size Part Number Minimum Quantity 500 100 AWG (67.4 mm²) 1/0 AWG (53.5 mm²) 5918-BK 5918 Reducing Bushings: for Use with Contact Part Number 6394 Use with contact part number 6394-BK to allow a smaller wire to be used with the connector. Electrical capability is derated with smaller wire. Dimensions - ID - Contact Barrel Size / Wire Size P art Numbers inches mm Minimum Quantity 1,000 100 35 mm² 16 mm² 5920-BK 5920 0.23 5.8 ID[ 25.4 ] 1.00 Wire Entrance Wire Entrance [ 28.4 ] 1.12 [ 11.1 ] 0.44 [ 21.4 ] 0.84 Wire Entrance ID
- 123 - All Data Subject To Change Without Notice www.andersonpower.com SBO® / SBE® / SBX® - Tooling Information Wire Size Loose Piece Part Number Loose Piece Contact Crimp Tools AWG mm² Contacts Pneumatic Bench Tool + Die + Locator Number of Crimps + Hand Tools SBE® 320 / SBX® 350
300 MCM 152 6358 N/A N/A N/A N/A
1368 Series
4/0 AWG 107.2 6356 1387G2 1303G12 1303G28 Double 3/0 AWG 85 6355 2/0 AWG 67.4 6354
2 N/A 6394 1303G2 1304G28
N/A 95 mm² 1341G3 1303G17 1304G35 N/A 70 mm² 1341G2 1303G12 1304G34 N/A 50 mm² 1341G1 1303G8 1304G36 SBE® 160 / SBX® 175 1/0 AWG 53.5 6384G1 1387G2 1303G13 1304G32 Double 1368 series2 25 mm² 6384G2 1387G2 1303G13 1304G32 Double 1/0 & #2 53.5 to 5mm 2 6384G1 & 6384G2 1387G1 1388G3 1389G3 Single SBO® 60 / SBE® 80 4 25 1339G4 1387G1 1388G7 1389G9 Single N/A 6 16 1339G1 1388G6 1309G4 Powerpole® 15/45 Auxiliary Contacts ** 16 to 20 1.3 to .52 1332 N/A N/A N/A Single 1309G2 or 1309G812 to 16 3.3 to 1.3 1331 PowerMod® 1x4 Auxiliary Contacts 12 to 24 2.5 to 0.25 All Crimp Pins TP0001* N/A TL0001 Single TM0001* All Crimp Sockets TL0002 PM1000G1 PPMX Auxiliary Contacts 20 to 24 0.50 to 0.25 4803G3 TP0001* N/A TL0005 Single TM0001* or 4802G3 PM1000G1 Tools PM1002G1 - 1 x 4 Auxiliary Contact Insertion Tool - For use with PM contacts and 1x4 auxiliary housing (444G1 housings and 441G kits) PM1003G1 - 1 x 4 Auxiliary Contact Insertion Tool - For use with PM contacts and 1x4 auxiliary housing (444G1 housings and 441G kits) PM1003GX - 1x4 Auxiliary contacts Inspection Tool - For use with PM contacts and 1x4 auxiliary housing (444G1 housings and 441G kits) 969P1 - SBE® 160 / SBX® 175 Power Contact Extraction Tool 970P1 - SBE® 320 / SBX® 350 Power Contact Extraction Tool * TP0001 and TM0001 tools require locators to properly position contacts. ** See Powerpole® family tooling chart for other Powerpole® contacts The auxiliary contacts used with wire sizes 16 to 24 AWG cannot be properly inserted without the insertion tool. Properly installed auxiliary contact of all wire gauges cannot be removed from the housing without the extraction tool. SBO® / SBE® / SBX® TOOLING Your Best Connection™ 2020-0055 DS-SBEX320-350 REV C7 Anderson™ will use reasonable efforts to include accurate and up-to-date content in the data sheet. All product information contained in the data sheet including ordering information, illustrations, specifications, and dimensions, are believed to be reliable as of the date of publishing, but is subject to change without notice. Anderson™ makes no warranty or representation as to its accuracy. Content in the data sheet may contain technical inaccuracies, typographical errors and may be changed or updated without notice. Anderson™ may also make improvements and/or changes to the products and/or to the programs described in the content at any time without notice. Current sales drawings and specifications are available upon request. ©2020 Anderson Power Products, Inc. All rights reserved. APP®, A®, Anderson Power Products®, SBE®, SBO®, SBX®, PowerMod®, Powerpole® and the APP Logo are registered trademarks of Anderson Power Products, Inc. Anderson™ and Your Best Connection™ are trademarks of Anderson Power Products, Inc.