Visit product website DATA SHEET Standard | EU | en | 202302 | 00 3/2 way pneumatic cartridge solenoid valve
- Compact design with 11 mm width per station Orifices from 0,5 mm (9 bar) to 1,2 mm (1,5 bar) High durability and reliability Low power consumption, as well as optional ATEX Ex ib version Design for optimum integration Customer specific applications are becoming more complex. Size, fluidic performance, low power consumption and cost efficiency are critical criteria. Therefore the demands on the components used are increasing. Type 6164 was developed with the goal, to simplify pneumatic control with optimum integration of a pilot valve in block and plastic moulding parts. Thus, making a more compact design possible. This valve sets new standards with its uncompromising reliability, above aver- age life cycle span and excellent fluidic characteristics. Various certifications and conformities make the use of the valve in medical applications such as media multiplexers in dental technology and oxygen control in respirators possible. Product variants described in the data sheet may differ from the product presentation and description. Type description Type 6164 © Christian Bürkert GmbH & Co. KG, Subject to alteration
2 | 17Visit product website Table of contents 1. General technical data 3 Circuit functions Materials 3.2. Material specifications 4. Dimensions 6 4.2. Defining of the installation area .... Cartridge connection (fully sunken) Cartridge connection (half sunken) 5. Device/Process connections 9 6. Performance specifications 10 7. Product design and assembly 11 8. Product accessories 12 9. Ordering information 12 9.2. Bürkert product filter 9.3. Ordering chart Standard version ATEX/IECEx i version 9.4. Ordering chart accessories Single manifold fully sunken Further accessories
3 | 17Visit product website 1. General technical data Product properties Dimensions Detailed information can be found in chapter “4. Dimensions” on page 6 Material Seal FKM Body PEEK Further materials in contact with the medium PA, LCP, MS, Edelstahl… Detailed information can be found in chapter “3.2. Material specifications” on page Permissible leakage Vac…10 bar (dependent on the version used)1.) Weight 6 g (standard version) Nominal diameter DN 0.5 / DN 0.8 / DN 1.0 / DN 1.2 Circuit function Detailed information can be found in chapter “2. Circuit functions” on page 4 Typical product service life 100.000,000 switching cycles (accordance to endurance tests) 2.) Performance data Duty cycle 100 % ED continuous rating Switching time3.) Opening: < 5 ms (pressure rise 0…10 %) Closing: < 5 ms (pressure drop 100…90 Electrical data Operating voltage 12 or 24 V DC (other voltages on request) Power consumption 0.7 W 2.8 W/0.3 W (with external electric power reduction)
0.3 W (for explosion proof version)
Switching noise 42 dB4.) Voltage tolerance ± 10 % Medium data Operating medium Neutral gases Medium temperature - °C…+ Process/Port connection & communication Electrical connection Plug/Solder, flying leads Port connection Bürkert Cartridge Connection Approvals and certificates Explosion proof (on request) Detailed information can be found in chapter “6.1. Electrical data ATEX/IECEx i version” on page 10 BVS 16 ATEX E 088 X II 2G Ex ib IIC T6…T4 Gb II 2D Ex ib IIIB T155 °C Db IECEx BVS 16.0053 X Ex ib IIC T6…T4 Gb Ex ib IIIB T155 °C Db Conformity (on request) UL class 2 Oxygen compatible Protection class Pins IP00 Special plug IP40 Flying leads IP54 Environment and installation Installation position As required Ambient temperature5.) - 10 °C…+ 55 °C 1.) Technical vacuum (- 0.8 bar) 2.) Life span is dependent on temperature, pressure, sealing material and operating conditions. 3.) Measurement at the valve outlet according to DIN ISO 12238:2001 4.) According to ISO 3745, testing environment in brass manifold, free-hanging 5.) Depending on installation conditions (see manual), higher temperatures on request
4 | 17Visit product website 2. Circuit functions Note: See “5.1. Pin assignment standard version” on page 9 Circuit functions Description 2 (A) 1 (P) Type: A, solenoid valve 2/2 way Direct-acting Normally closed 2 (B) 1 (P) Type: B, solenoid valve 2/2 way Direct-acting Normally open 2(A) 1(P) 3(R) Type: C, solenoid valve 3/2 way Direct-acting Normally closed 2(B) 1(P) 3(R) Type: D, solenoid valve 3/2 way Direct-acting Normally open 2(A) 1(P) 3(R) Type: T, solenoid valve 3/2 way Direct-acting Flow direction optional Normally closed
5 | 17Visit product website 3. Materials 3.1. Chemical Resistance Chart – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check 3.2. Material specifications No. Element Material 1 Coil housing 1.4113 2 Core (wetted parts) 1.4113
3 O-Rings (wetted parts) FKM
4 Body (wetted parts) PEEK
5 Seal switch (wetted parts) PA
6 Seal (wetted parts) FKM
7 Spring (wetted parts) 1.4310
8 Fitting (wetted parts) Brass
– Coil body (wetted parts, not visible) LCP
6 | 17Visit product website 4. Dimensions 4.1. Pin and flying leads version Note: Dimensions in mm Pin version Flying leads version 0.5 8.3 19.7 (without seal) (28) 3.8 3.3 3.8 6.9 2.1 5.08 7.6 3.2 4.3 1.4 2.65 (1.65) Ø D max. Ø 9.1 Ø 1.15 19.7 (without seal) 10 (29.7) max. Ø 9.1 2.1 6.9 3.8 6.3 2.8 4.3 1.4 (2.65) 1.65 7.6 2.5 6.9 Version Measurement D DN < 0.65 Ø 2.7 DN > 0.65 Ø 3.3
7 | 17Visit product website 4.2. Defining of the installation area Cartridge connection (fully sunken) Note: For explanation see also “7. Product design and assembly” on page 11 Observe max. tightening torque of the screw (see User Manual Type 6164 Dimensions in mm M2.5 6.5 11.2 ±0.05 14.5 ±0.05 19.85 ±0.03 30° 0.3 19.55 ±0.03 13.75 ±0.03 Slot for dismantling is recommended Rmax=16 Ra0.8 M2.5 13.2 R0.2±0.10 1.4 ±0.05 4.2 8.77 ±0.05 9.1 ±0.05 1.3 ±0.03 9.2 ±0.05 0.1x30° 30° 30° Rmax=10 Ra0.8 Ra 1.6 -0.2 +0.1 * Diameter tolerance acc. to ISO 14405 E The position of the M2.5 thread is freely selectable on the diameter Ø13.2 E E E
8 | 17Visit product website Cartridge connection (half sunken) Note: For explanation see also “7. Product design and assembly” on page 11 A mounting bracket set is required for mounting, see “9.4. Ordering chart accessories” on page 15 Dimensions in mm 13.2 ±0.05 7.5 ±0.05 0.3 30° 3.8 ±0.05 9.15 ±0.03 3.05 ±0.03 8.85 ±0.03 Rmax=16 Ra0.8 1.4 ±0.05 8.77 ±0.05 0.1x30° 30° 9.1 ±0.05 1.3 ±0.03 4.2 Rmax=10 Ra0.8 1.5 -0.1 M1.6 Rmax=10 Ra0.8 -0.2 +0.1 Ra 1.6 * Diameter tolerance acc. to ISO 14405 E E E
9 | 17Visit product website 5. Device/Process connections 5.1. Pin assignment standard version Note: The pin assignment (marked No. 1, 2 and 3 in the drawing) depends on the circuit function. In the table, compare the respective pin assignment with the corresponding circuit function. The polarity must be observed only in the Ex version. Circuit functions Port 1 Port 2 Port 3 3 way A, solenoid valve 2/2 way Direct-acting Normally closed 2 (A) 1 (P) (same valve as for circuit function C by blind connection to 3) Pressure port Working port Blind Wirkungsweise C (auch als WWA einsetzbar durch Blindanschluss an 3) Wirkungsweise D (auch als WWB einsetzbar durch Blindanschluss an 3) Wirkungsweise T B, solenoid valve 2/2 way Direct-acting Normally open 2 (B) 1 (P) (same valve as for circuit function D by blind connection to 3) Pressure port Working port Blind Wirkungsweise C (auch als WWA einsetzbar durch Blindanschluss an 3) Wirkungsweise D (auch als WWB einsetzbar durch Blindanschluss an 3) Wirkungsweise T C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R) (applicable to circuit function A by using blind connectors on 3) Pressure port Working port Ventilation Wirkungsweise C (auch als WWA einsetzbar durch Blindanschluss an 3) Wirkungsweise D (auch als WWB einsetzbar durch Blindanschluss an 3) Wirkungsweise T D, solenoid valve 3/2 way Direct-acting Normally open 2(B) 1(P) 3(R) (applicable to circuit function B by using blind connectors on 3) Pressure port Working port Ventilation Wirkungsweise C (auch als WWA einsetzbar durch Blindanschluss an 3) Wirkungsweise D (auch als WWB einsetzbar durch Blindanschluss an 3) Wirkungsweise T T, solenoid valve 3/2 way Direct-acting Flow direction optional Normally closed 2(A) 1(P) 3(R) Pressure port Working port Ventilation Wirkungsweise C (auch als WWA einsetzbar durch Blindanschluss an 3) Wirkungsweise D (auch als WWB einsetzbar durch Blindanschluss an 3) Wirkungsweise T
10 | 17Visit product website 6. Performance specifications 6.1. Electrical data ATEX/IECEx i version Note: The valve is designed to operate on 24 V DC outputs through an intermediary intrinsically safe apparatus (isolating block or barri er). Please refer to the Type 6164 Instruction Manual for the permissible maximum values/value pairs. Type of protection: BVS 16 ATEX E 088 X: II 2G Ex ib IIC T6…T4 Gb & II 2D Ex ib IIIB T155 °C Db IECEx BVS 16.0053 X: Ex ib IIC T6…T4 Gb & Ex ib IIIB T155 °C Db SPS Barrier/ isolation module 24 V DC > 9.3 V DC +≥ 30 mA+ Version Resistance at 20 °C ± 4 % Minimum terminal voltage Minimum current [Ohm] [V] [mA] Version for use with 300 Ω supply module 320 9.3 29 High-resistance version 510 11.7 23
11 | 17Visit product website 7. Product design and assembly 7.1. Application examples Single block with Cartridge Cartridge installation position Fully sunken multi-manifold Semi-sunken multi-manifold
12 | 17Visit product website 8. Product accessories 8.1. Single manifold fully sunken Note: Dimensions in mm Max. tightening torque of the screw must be observed (see operating instructions Type 6164 10.7 17.6 Ø 4.5 3.8 4.5 M2.5 6.5 19.55 13.75 Description Article no. Manifold 1 place, brass 695913 9. Ordering information 9.1. Bürkert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 9.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter
13 | 17Visit product website 9.3. Ordering chart Standard version Circuit functions Port connection Orifice ventilation Orifice ventilation QNn value air1.) QNn value air1.) Voltage/ Frequency Nominal power Pressure range2.) Article no. with connection pins[mm] [mm] [l/min] [l/min] [V/Hz] [W] [bar] C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R) Bürkert Cartridge connection 0.5 0.65 6 9.55 12/DC 0.7 Vac…9 273612 24/DC Vac…9 272893 24/DC 2.5…10 281022 1.0 1.1 20 20 Vac…5 285700 1.2 1.1 25 22 Vac…1.5 272894 D, solenoid valve 3/2 way Direct-acting Normally open 2(B) 1(P) 3(R) Bürkert Cartridge connection 0.65 0.5 6.5 6 12/DC 0.7 Vac…6 273615 24/DC 0.7 273614 T, solenoid valve 3/2 way Direct-acting Flow direction optional Normally closed 2(A) 1(P) 3(R) Bürkert Cartridge connection 0.5 0.65 6 6 24/DC 0.7 Vac…4 292608 1.) Measurement at 6 bar and + 20 °C at the valve inlet and 1 bar pressure difference 2.) Technical vacuum (- 0.8 bar) 3.) External power reduction electronics necessary
14 | 17Visit product website ATEX/IECEx i version Note: BVS 16 ATEX E 088 X II 2G Ex ib IIC T6…T4 Gb & II 2D Ex ib IIIB T155 °C Db IECEx BVS 16.0053 X Ex ib IIC T6…T4 Gb & Ex ib IIIB T155 °C Db Circuit functions Port connection Orifice ventilation Orifice ventilation QNn value air1.) QNn value air1.) Pressure range2.) Resist- ance at Min. holding current Article no. with connection pins [mm] [mm] [l/min] [l/min] [bar] [Ω] [mA] C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R) Bürkert Cartridge connection 0.5 0.65 6 9.5 Vac…6 320 29 289027 510 23 289028 D, solenoid valve 3/2 way Direct-acting Normally open 2(B) 1(P) 3(R) Bürkert Cartridge connection 0.65 0.5 6.5 6 Vac…4 320 29 auf Anfrage 1.) Measurement at 6 bar and + 20 °C at the valve inlet and 1 bar pressure difference 2.) Technical vacuum (- 0.8 bar) Further versions on request Additional Leads version up to 300 mm Voltage Voltages 9 V, 6 V, 3 V Approval Oxygen compatibility: Suitable for the oxygen application labeled with a blue sticker
15 | 17Visit product website 9.4. Ordering chart accessories Single manifold fully sunken Ordering information and dimensions of the single manifold fully sunken can be found in chapter “8.1. Single manifold fully sunken” on page 12 Further accessories Accessories Description Article no. Valve and manifold block not included in spare parts set Mounting bracket set for semi-recessed mounting for type 6164 Scope of delivery: 2 x fixing screws; M1.6x5; stainless steel A2 1 x mounting bracket; 1.4310 696032 Plug for Type 6164 with two PVC wires; AWG 24; length 300 mm 695951
16 | 17Visit product website Accessories Description Article no. Valve not included in spare parts set Spare parts set for Type 6164 Scope of delivery: 1 x cheese head screw with internal TORX T8; M2.5x5; stainless steel A2 2 x O-ring large; FKM 1 x O-ring small; FKM 696033
Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa Russia United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -