Visit product website DATA SHEET Type 2516 Cable plug, form C according to DIN EN 175301-803 Type 2505 10 mm socket for Bürkert small solenoid valves Standard | EU | en | 202302 | 06 2/2 or 3/2 way Pneumatic-Rocker-Solenoid Valve
- Compact design with 16 mm width DN 0.9 and DN 1.2 (10 bar) High lifecycle Low power consumption, ATEX Ex ia on request For pneumatic applications The direct-acting rocker solenoid valve type 6106 is designed for use on neu- tral gaseous mediums. The heat input in the medium is minimal, because the housing is separated from the coil by a stainless steel plate. The valves can be mounted directly or also single or manifold mounted. They are used for dosing, filling, mixing and distributing small quantities of medium. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 6106 © Christian Bürkert GmbH & Co. KG, Subject to alteration
2 | 17 Visit product website Table of contents 1. General technical data 3 1.2. Medium pressure 2. Product versions 4 Circuit functions Materials 4.2. Material specifications 5. Dimensions 6 5.2. Bürkert sub-base interface 3-way standard 5.3. CNOMO angled sub-base version with cable plug lateral Type 2516 5.4. CNOMO flange interface 3-way 6. Product design and assembly 8 7. Performance specifications 8 8. Ordering information 9 8.2. Bürkert product filter 8.3. Ordering chart 8.4. Ordering chart accessories Mounting set for standard rail Rectangular cable plug Type 2505 Cable plug Type 2516, form C according to DIN EN 175301 - 803 Multiple manifolds for Bürkert sub-base interface 3-way Single manifolds for Bürkert sub-base interface 3-way Multiple manifolds for CNOMO flange 3-way Single manifolds for CNOMO flange 3-way
3 | 17 Visit product website 1. General technical data 1.1. General data Product properties Dimensions Detailed information can be found in chapter “5. Dimensions” on page 6 Material Seal FKM Fluid body PA (polyamide) Minimum bending radius for flying leads version Single bending: 8.5 mm Orifice DN 0.9 or DN 1.2 (other orifices on request) Circuit function Detailed information can be found in chapter “3. Circuit functions” on page 4 Performance data Switching time1.) Standard version Opening: approx. 25 ms (pressure rise 0…10 %) Closing: approx. 25 ms (pressure drop 100 %...90 Explosion-proof version Opening: approx. 25 ms (pressure rise 0…10 Closing: approx. 35 ms (pressure drop 100 %...90 Electrical data Operating voltage 12/24 V DC (other voltages on request) Duty cycle 100 % continuous rating Nominal power Standard version 1 W or 2 W Explosion-proof version 0.5 W Voltage tolerance2.) ± 10 % Switching frequency3.) Ca. 16 Hz Medium data Operating medium Resistant to neutral gases (5 µm filtering); see chapter “4.1. Chemical Resistance Chart – Bürk- ert resistApp” on page 5 Medium temperature (max.) - °C…+ Viscosity (max.) 21 mm²/s Process/Port connection & communication Electrical connection4.) Tag connectors according to DIN EN 175301- 803 form C for cable plug Type 2516 top/lateral Two FEP-leads 0.2 mm² (AWG24), length 500 mm Rectangular plug Type 2505 Port connection Bürkert sub-base (16 27 mm) CNOMO lateral flange Approvals and certificates Degree of protection IP65 with flying leads or cable plug Type 2516 IP30 with rectangular plug Type 2505 Type of protection Standard version Without Explosion-proof version PTB 01 ATEX 2175: II 2 G Ex ia IIC T5, T6 Gb IECEx PTB 06.0102: Ex ia IIC T5, T6 Gb Environment and installation Installation position As required, preferably with actuator upright Ambient temperature (max.) - °C…+ 1.) Measurement at 6.3 bar and + 20 °C at the valve outlet acc. to DIN ISO 12238:2001 2.) Max. allowed ripple 3.) At ambient temperature 20 4.) Other electric connectors and other cable lengths are available on request.
4 | 17 Visit product website 1.2. Medium pressure Note: Pressure data: Overpressure to atmospheric pressure Different pressure ranges available on request Circuit functions Orifice Nominal power Port connection Max. differential pressure [mm] [W] [bar] C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R) 0.9 1 Sub-base Vac…8 1.2 2 Sub-base Vac…10 D, solenoid valve 3/2 way Direct-acting Normally open 2(B) 1(P) 3(R) 0.9 1 Sub-base Vac…8 1.2 2 Sub-base Vac…10 2. Product versions Bürkert sub-base version with cable plug lateral CNOMO angled sub-base version with cable plug lateral 3. Circuit functions Circuit functions Description 2(A) 1(P) 3(R) Type: C, solenoid valve 3/2 way Direct-acting Normally closed 2(B) 1(P) 3(R) Type: D, solenoid valve 3/2 way Direct-acting Normally open
5 | 17 Visit product website 4. Materials 4.1. Chemical Resistance Chart – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check 4.2. Material specifications 1 No. Element Material
1 Rounded head screw M2 Stainless steel
2 Coil Epoxy
3 Intermediate plate
(medium contact) Stainless steel and nickel solder
4 Body seal
(medium contact) FKM
5 Anchor
(medium contact) Stainless steel
6 Seat seal
(medium contact) FKM
7 Fluid body
(medium contact) PA
8 Flange seal
(medium contact) FKM 9 Rounded head screw M2.5 Stainless steel
6 | 17 Visit product website 5. Dimensions 5.1. Bürkert sub-base version with cable plug lateral Type 2516 Note: Dimensions in mm 27.1 approx. 55* approx. 27.5* M2.5 4.8 39.2 11.2 * Dimension depends on the appliance cable plug used 5.2. Bürkert sub-base interface 3-way standard Note: Dimensions in mm 21.5 10.5 M2.5 min. 6 max. Ø 2.5
7 | 17 Visit product website 5.3. CNOMO angled sub-base version with cable plug lateral Type 2516 Note: Dimensions in mm approx. 63* 4.7 27.1 approx. 27.5* 47.5 19.5 * Dimension depends on the appliance cable plug used 5.4. CNOMO flange interface 3-way Note: Dimensions in mm 9.7 1.4 7.6 min. 6 max. Ø 2.5
8 | 17 Visit product website 6. Product design and assembly 6.1. Application examples Application Description Application Description Device with plug form C lateral and tube spigot connection Device with plug form C lateral and tube coupling Device with rectangular plug and G ⅛" manifold Device with flying leads and M5 manifold 7. Performance specifications 7.1. Electrical data explosion-proof version Ex ia Note: The valve is designed to operate on 24 V DC outputs through an intermediary intrinsically safe apparatus (isolating block or barri er). Please refer to the additional instructions Type AC21 ATEX 2175 for the permissible maximum values/value pairs. Type of protection: PTB 01 ATEX 2175: II 2 G Ex ia IIC T5,T6 Gb IECEx PTB 06.0102: Ex ia IIC T5,T6 Gb SPS/ PLC Barriere/ isolating component
24 V DC ≥ Umin
+≥ lmin+ Version Resistance at 20 °C ± 4 % Minimum terminal voltage Minimum current [Ω] [V] [mA] For use with a 30 Ω supply module 320 9.3 29 High resistance version 475 10.9 23
9 | 17 Visit product website 8. Ordering information 8.1. Bürkert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 8.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter 8.3. Ordering chart Note: Valves listed below with tag connector sidewards, manual override, flange seals and fixing screws (2xM2.5x16 for Bürkert sub- base and 2xM3x30 for CNOMO flange) Also available as an option without manual override Connectors for rectangular plugs and cable plugs are not included in the delivery and must be ordered separately, see “8.4. Or- dering chart accessories” on page 10 Further versions on request Circuit function Port connection Orifice QNn value air1.) 12 QNn value air1.) 23 Voltage/ Frequency Power consumption Pressure range Article no. [mm] [l/min] [l/min] [V/Hz] [W] [bar] C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R) Bürkert sub-base 0.9 22 25 24/DC 1 Vac…8 126417 CNOMO flange 126418 Bürkert sub-base 1.2 40 47 24/DC 2 Vac…10 126411 CNOMO flange 33 38 126414 D, solenoid valve 3/2 way Direct-acting Normally open 2(B) 1(P) 3(R) Bürkert sub-base 0.9 22 25 24/DC 1 Vac…8 126421 CNOMO flange 126422 Bürkert sub-base 1.2 40 47 24/DC 2 Vac…10 126419 CNOMO flange 33 38 126420 1.) Measurement at + 20 °C, 6 bar pressure at valve inlet and 1 bar pressure difference
10 | 17 Visit product website Further versions on request Approval ATEX EEX I, UL /CSA Electrical connection Industrial plug form C, Bürkert rectangular plug, flying leads connection Process connection Bürkert sub-base, CNOMO flange, plug-in coupling, tube body 8.4. Ordering chart accessories Mounting set for standard rail Note: Suitable for standard rail TS35 7.5 mm Description Article no. Mounting set 629254 Rectangular cable plug Type 2505 Note: For further versions see data sheet Type 2505 Accessories Description Article no. Rectangular cable plug Type 2505 with 3 m cable 252572 Rectangular cable plug Type 2505 with 5 m cable 255194 Rectangular cable plug Type 2505 with 300 mm flying leads 644068 Rectangular cable plug Type 2505 with 600 mm flying leads 162144
11 | 17 Visit product website Cable plug Type 2516, form C according to DIN EN 175301 - 803 Note: Delivery of cable plug includes a flat seal and a fixing screw. For further versions see data sheet Type 2516 Cable plug Dimensions Version Voltage Article no. 15.8 28 approx. 10 Ø 15 M2.5 (1.5) 15.8 (16.8)max. 3.4 -1 3.6 -1 Without circuitry 0…250 V AC/DC 303141 With LED 12…24 V AC/DC 303145 With LED and varistor 12…24 V AC/DC 303148
12 | 17 Visit product website Multiple manifolds for Bürkert sub-base interface 3-way Note: Dimensions in mm Port connection 1: G ⅛" Port connection 2: M5 Material aluminium (black anodized) Consider the screw protrusion! Further versions on request A (18) B 12.5 G⅛" 3 16.5 Ø 8.5 5 10 A-10 Manifold A B n Article no. 2-fold 63 18 2 658695 3-fold 81 36 3 658696 4-fold 99 54 4 658697 5-fold 117 72 5 658698 6-fold 135 90 6 658699 8-fold 171 126 8 658700 10-fold 207 162 10 658701 12-fold 243 198 12 658703 Blanking plate kit for non-configured valve positions 629327
13 | 17 Visit product website Single manifolds for Bürkert sub-base interface 3-way Note: Dimensions in mm Port connection M5 Material aluminium (black anodized) Consider the screw protrusion! Further versions on request M 2.5 10.5 6.5 (M 3) M 2.5 8.5 M 5 21.5 8.5 Manifold Article no. 1-fold 623873
14 | 17 Visit product website Note: Dimensions in mm Port connection G ⅛” Material aluminium (black anodized) Consider the screw protrusion! Further versions on request 10.5 13.5 21.5 10.5 G ⅛" 9.2 6.5 6.5 14.5 (M 2.5) Manifold Article no. 1-fold 634917
15 | 17 Visit product website Multiple manifolds for CNOMO flange 3-way Note: Dimensions in mm Port connection 1: G ⅛" Port connection 2: M5 Material aluminium (black anodized) Consider the screw protrusion! Further versions on request32 L 9.7 17.4 16.5 7.6 5.5 12.2 8.25 A A G 1/8" (16.5) 17 7 Ø 2.5 A-A Manifold L Article no. 2 fold 33 639887 3 fold 49.5 639862 4 fold 66 639863 5 fold 82.5 639864 6 fold 99 639865 8 fold 132 639866 10 fold 165 639867 12 fold 198 639868 Blanking plate kit for non-configured valve positions 639695
16 | 17Visit product website Single manifolds for CNOMO flange 3-way Note: Dimensions in mm Port connection M5 Material aluminium (black anodized) Consider the screw protrusion! Further versions on request 12.5 4.5 4.5 9.7 2.65 5 5 3.2 3.8 7.6 9.7 Manifold Article no. 1-fold 639885
Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa Russia United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -