60DDW-3 GAPTEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 1 of 3 60DDW_3 – Rev. 2020-1.1 Specifications subject to change without notice. 60DDW_3 Series 60W - Single/Dual Output - Wide Input - Isolated & Regulated DIP DC-DC Converter High efficiency up to 88% 2:1 wide input voltage range Isolation voltage 3000VDC Six-sided metal shield Short circuit protection (SCP) (automatic recovery) Operating temperature: -40°C to +85°C Over temperature protection Industry standard pinout Under voltage lockout DC-DC Converter 60 Watt The 60DDW series offers 60W of output, wide input voltage of 9-18VDC, 18-36VDC and 36-72VDC and features 3000VDC isolation, six-sided metal shield over current and short circuit protection. All models are particularly suited to tele-communications, industrial, test equipments power etc. Example: 60DDW_2415S3 60 = 60Watt; D = DIP; D = series; W = wide input (2:1) 24 = 18-36Vin; 15Vout; S = single output; 3 = 3000VDC isolation Common specifications Cooling: Free air convection Short circuit protection: Continuous, auto-recovery Operation temperature range: -40°C~+85°C Storage temperature range: -55°C~+100°C Case temperature: 90°C MAX Lead temperature range: 265°C MAX, 1.5mm from case for 10 sec Switching frequency (PWM mode): 50kHz TYP Humidity: non-condensing, 95% MAX Case material: Six-Side Shielded Case Potting material: Epoxy (UL94V-0 rated) Radiated Emissions: EN55022, Class A Conducted Emissions: EN55022, Class A MTBF (MIL-HDBK-217F @25°C)*: >299,424 hours Weight: 227.5g Note: 1. Input voltage can’t exceed this value, or will cause the permanent damage. 2. The load shouldn‘t be less than 5%, otherwise ripple will increase dramati- cally. 3. Max. Capacitive Load is tested on Vin-nominal and full load. 4. All specifications measured at Ta = 25°C, humidity <75%, nominal input voltage and rated output load unless otherwise specified. 5. In this datasheet, all the test methods of indications are based on corporate standards. 6. Only typical models listed, other models may be different, please contact our technical person for more details. 7. Specifications subject to change without notice. Output specifications Item Test condition Min Typ Max Units Voltage tolerance Single/dual ±2 % Over load protection Input voltage range 120 150 180 % Line regulation Single & Dual (H/L to L/L) ±0.5 % Load regulation Single & Dual (25% to 100% load) ±0.5 % Minimum load 30% of full load Ripple and noise* 20MHz Bandwidth 150 mVp- p Transient respon- se setting time 50% load step change 400 µs Capacitive load 1500 µF External Trim Adj. Range ±10% of Output Voltage * Test ripple and noise by “parallel cable” method. Typical value at nominal input voltage and no load. Input specifications Item Test condition Min Typ Max Units Filter Pi network Protection Fuse recommended Isolation specifications Item Test condition Min Typ Max Units Isolation voltage Input/Output, tested for 1 minute

3000 VDC

Isolation resistance 500VDC 1000 MΩ Isolation capacitance Input/Output 2500 pF

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 2 of 3 60DDW_3 – Rev. 2020-1.1 Specifications subject to change without notice. 60DDW_3 Series 60W - Single/Dual Output - Wide Input - Isolated & Regulated DIP DC-DC Converter Part Number Input Voltage Range [VDC] Input current [mA, typ] no load full load Output Voltage [VDC] Output Current [mA] Efficiency [%, Typ.] 60DDW_1205S3 9-18 40 5208 5 10000 80 60DDW_1212S3 9-18 40 5882 12 5000 85 60DDW_1215S3 9-18 40 5814 15 4000 86 60DDW_1205D3 9-18 40 5144 ±5 ±5000 81 60DDW_1212D3 9-18 40 5747 ±12 ±2500 87 60DDW_1215D3 9-18 40 5747 ±15 ±2000 87 60DDW_2405S3 18-36 30 2572 5 10000 81 60DDW_2412S3 18-36 30 2841 12 5000 88 60DDW_2415S3 18-36 30 2841 15 4000 88 60DDW_2405D3 18-36 30 2572 ±5 ±5000 81 60DDW_2412D3 18-36 30 2874 ±12 ±2500 87 60DDW_2415D3 18-36 30 2841 ±15 ±2000 88 60DDW_4805S3 36-72 20 1270 5 10000 82 60DDW_4812S3 36-72 20 1420 12 5000 88 60DDW_4815S3 36-72 20 1420 15 4000 88 60DDW_4805D3 36-72 20 1270 ±5 ±5000 82 60DDW_4812D3 36-72 20 1437 ±12 ±2500 87 60DDW_4815D3 36-72 20 1437 ±15 ±2000 87 Typical characteristics Output voltage adjustment, Control PIN suggest circuit Output can be externally trimmed by using the method shown below. Temperature derating graph Tolerance envelope graph

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 3 of 3 60DDW_3 – Rev. 2020-1.1 Specifications subject to change without notice. 60DDW_3 Series 60W - Single/Dual Output - Wide Input - Isolated & Regulated DIP DC-DC Converter Mechanical dimensions Note: Unit: mm[inch] Pin diameter tolerances: ±0.05mm [±0.002inch] General tolerances: ±0.25mm [±0.010inch] PIN connection PIN 1 2 3 4 5 6 7 8 Single +Vin -Vin No pin Trim No pin +Vout -Vout Remote On/ Off Dual +Vin -Vin +Vout Com -Vout No pin No pin Remote On/ Off Input external filter Suggest adding input external filter (C1, C2, C3, C4, C5, L) to meet conducted emissions (EN55022 class A) requirement for the module. These components should be mounted as close as possible to the module; and all leads should be minimized to decrease radiated noise.