Visit product website  DATA SHEET Type 8605  PWM control electron- ics for electromagnetic proportional valves Type 2518  Cable Plug DIN EN 175301-803 - Form A Type 8611  eCONTROL - Universal controller 1000017535 | Standard | EU | en | 202101 | 09 Direct-acting 2-way low differential pressure solenoid control valve

  • For high flow rates with low inlet pressure
  • Direct-acting, normally closed
  • Operating pressure 0 ... 0.7 bar
  • Orifice sizes ... mm
  • Port connection 1/2” and 3/4” The direct-acting proportional valve Type 6024 works as an electromagnet- ically actuated control valve with relatively high flow rates at low operating pr essures. The valve is normally closed. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 6024 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 11 Visit product website  Table of contents 1. Gener al Technical Data 3 Cir cuit functions Materials 4. Dimensions 4 4.2. Brass version with coil size K 4.3. Stainless steel version with coil size 4.4. Stainless steel version with coil size K 5. Performance specifications 8 Det ermination of the 5.2. Ex emplary characteristic curve of a proportional valve 6. Or dering information 8 6.2. Recommendation r egarding product selection 6.3. Bürkert product filter 6.4. Or dering chart 6.5. Or dering chart accessories Cable plug Type 2518, Form A according to DIN EN 175301 803 Control unit Type 8605

3 | 11 Visit product website  1. Gener al Technical Data Product properties Dimensions Detailed information can be found in chapter “4. Dimensions” on page 4. Material Body Brass, stainless steel Seal FKM, others on request Performance data Typical values of positioning behaviour1.) Hysteresis < 7% Reproducibility < 0.5% of end value2.) Response sensitivity < 0.5% of end value2.) Setting range 1:25 KV value3.) 1.4…2.8 m³/h Maximum operating pressure4.) 0.1…0.7 bar (depending on DN) Nominal oper ating mode 100 % continuous oper ation Electrical data Operating voltage 24 V DC (12 V on request) Power consumption 18 W Maximum coil current5.) 620 mA PWM frequency6.) 280 Hz Medium data Operating medium Neutral gases, liquids Medium temperature °C… V iscosity Maximum 21 mm2/s (21 cSt) P rocess/Port connection & communication Port connection size G G (NPT and NPT on request) Electrical connection Cable plug Type 2518 acc. to DIN EN 175301 803 form A Detailed information can be found in chapt er “Cable plug Type 2518, Form A accord- ing to DIN EN 175301 803” on page 10. Approvals and certificates Degree of protection IP65 Environment and installation Installation position Any, preferably actuator face up Ambient temperature Maximum 1.) Characteristic data of control behaviour depends on process conditions. 2.) By flow measurement 3.) KVS value: Flow rate value for water 4.) Pressure data: Overpressure with respect to atmospheric pressure, depending on nominal diameter, tightness seal or nominal pressure 5.) Maximum value: value depends on operating pressure 6.) PWM: pulse width modulation 2. Cir cuit functions Circuit functions Description 2 (A) 1 (P) Type: A, proportional control valve 2/2 way Direct-acting Normally closed

4 | 11 Visit product website  3. Mat erials 3.1. Chemical Resistance Char t – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our r esistApp. Start Chemical Resistance Check 4. Dimensions 4.1. Br ass version with coil size 8 Note: Dimensions in mm BB A A SW 32 64 7 44.5 125 24.5 SW 22 50.5 Port connection A B G ½ G ½ 14 NPT (on request) NPT ½ 14 G ¾ G ¾ 16 NPT (on request) NPT ¾ 16

5 | 11 Visit product website  4.2. Br ass version with coil size K Note: Dimensions in mm BB A A SW 32 7 64 55.5 44.5 125 50.5 SW 22 Port connection A B G ½ G ½ 14 NPT (on request) NPT ½ 14 G ¾ G ¾ 16 NPT (on request) NPT ¾ 16

6 | 11 Visit product website  4.3. S tainless steel version with coil size 8 Note: Dimensions in mm A B B A SW 32 64 7 44.5 125 24.5 SW 22 50.5 Port connection A B G ½ G ½ 14 NPT (on request) NPT ½ 14 G ¾ G ¾ 16 NPT (on request) NPT ¾ 16

7 | 11 Visit product website  4.4. S tainless steel version with coil size K Note: Dimensions in mm A A B B 7 64 SW 32 55.5 44.5 125 50.5 SW 22 Port connection A B G ½ G ½ 14 NPT (on request) NPT ½ 14 G ¾ G ¾ 16 NPT (on request) NPT ¾ 16

8 | 11 Visit product website  5. P erformance specifications 5.1. Flow char acteristic Determination of the KV value Pressure drop KV value for liquids KV value for gases [m3/h] [m3/h] Sub-critical p2 > 2 = Q ρ Δp1000 = Q 514 QN ρNT1 Δ pp2 Supercritical p2 < 2 = Q ρ Δp1000 = Q QN ρNT1 257 p1 KV Flow coefficient [m3/h]1.) QN Standard flow rate [mN 3/h]2.) p1 Inlet pressure [bar]3.) p2 Outlet pressure [bar]3.) ∆p Differential pressure p1-p2 [bar] ρ Density [kg/m3] ρN Standard density [kg/m3] T1 Medium temperature [(273+t)K] 1.) Measured for water, 1 bar over the value 2.) At reference conditions 1.013 bar and (273 3.) Absolute pressure 5.2. Ex emplary characteristic curve of a proportional valve Note: In continuous flow applications, the choice of an appropriate valve size is much more important than with on/off valves. The optimum siz e should be selected such that the resulting flow in the system is not unnecessarily reduced by the valve. However, a sufficient par t of the pressure drop should be taken across the valve even when it is fully opened. Recommended value: Δpvalve > 25 % of total pressure drop within the system Otherwise, an ideal, linear valve characteristic is deformed into a curved system characteristic. If the differential pressure (difference between inlet and outlet pressure) exceeds half the value of the nominal pressure discontinuities may occur For that reason take advantage of Bürkert competent engineering services during the planning phase! 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 K V KVS 0 5 10 [V] 4 12 20 [mA] 0 10 20 [mA]

9 | 11Visit product website  6. Or dering information 6.1. Bürk ert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and fast delivery You want to find your desired Bürkert product or spare part quickly and order dir ectly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 6.2. Recommendation r egarding product selection Note:

  • Please use the “Product Inquiry Form” at the end of this data sheet for the specifications of the device configuration and send us a copy of the inquiry with information about the application.
  • Please note the chapter “5.2. Exemplary characteristic curve of a proportional valve” on page 8 of product selection. 6.3. Bürk ert product filter Bürkert product filter – Get quickly to the right product Y ou want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily Try out our product filter 6.4. Or dering chart Note:
  • All valves with FKM seal
  • Please note that the cable plug must be ordered separately, see “Cable plug Type 2518, Form A according to DIN EN 175301 803” on page 10 or separate data sheet for Type 2518 Circuit function Orifice Port connection KVS value water1.) Maximum pressure 2.) Coil power Maximum coil current Article no. brass body Article no. stainless steel body [mm] [m 3/h] [bar] [W] [mA] A, proportional control valve 2/2 way Direct-acting Normally closed 2 (A) 1 (P) 8 G ½ 1.4 0.7 18 620 150401  – G ¾ 1.4 0.7 18 620 150427  – 10 G ½ 2.0 0.4 18 620 150402  150404  G ¾ 2.0 0.4 18 620 150428  150429  12 G ½ 2.8 0.2 18 620 – 150426  G ¾ 2.8 0.2 18 620 150406  150408  1.) Flow rate value for water, measured at + 20 °C and 1 bar pressure differential over a fully opened valve 2.) Pressure data: Overpressure with respect to atmospheric pressure

10 | 11Visit product website  6.5. Or dering chart accessories Cable plug Type 2518, Form A according to DIN EN 175301 - 803 Not Further versions see data sheet Type 2518 Cable plug Dimensions Version Voltage Article no. ca. 51 35.7 3.5 1.5 29.2 Ø 19 29.2 Without circuitry (AC/DC) 0…250 V A C/DC 314802 Control unit Type 8605 Note: Further versions see data sheet Type 8605 Control unit Version Max. coil current range Type 6024 Type 6024 Article no. [mA] 24 V DC 12 V DC Cable plug with PG cable gland 200…1000 x – 316530  C able plug with M12 connection 200…1000 x – 316528  Cable plug with PG cable gland 500…2000 x x 316529  Cable plug with M12 connection 500…2000 x x 316526  Cable plug with PG cable gland without operating element 200…1000 x – 316521  C able plug with M12 connection without operating element 200…1000 x – 316522  Cable plug with PG cable gland without operating element 500…2000 x x 316523  Cable plug with M12 connection without operating element 500…2000 x x 316525  Standard rail 200…1000 x – 316532  Standard rail 500…2000 x x 316533  x: on request

Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa Russia United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -

74653 Künzelsau

www.burkert.com

1 | 1Visit this product area on the website  © Christian Bürkert GmbH & Co. KG, subject to change Product Enquiry Form - Proportional valve Thank you for your interest in our products! In order to provide you with optimum advice, please fill out the following form and send it to your Bürkert r epresentative or e-mail address: info@burkert.com. All information submitted will of course be kept strictly confidential. Please fill in the required fields! *Note: The interactive functions of this PDF may be restricted depending on the PDF reader used. Personal Information Company Contact person Customer no. Department Street Postcode / Town Telephone no. Email Delivery Quantity Required delivery date Operating data Function (Function of the control valve in the pr ocess / process description) Operating medium Type of medium Fluid S team Gas Supply voltage V Ambient t emperature (max.) tu max = ºC / ºF Fluidic data Flow range Q Nom min. max. unit Inlet pressure at QNom p1 = barg1.) Outlet pressure at QNom p2 = barg1.) Max. inlet pressure p1max = barg1.) Medium temperature (min./ max.) tm min = tm max = ºC / ºF Port connection G (DIN ISO 228/1) NPT (ANSI B1.2) Flange Other 1.) Please indicate all pressure values as overpressure to atmospheric pressure [barg] (g = relative pressure) Material specifications Body S tainless steel Br ass Other Seals F K M EPDM Other Approvals / Conformities UL/UR, KTW W270, DVGW Gas, ATEX/IECEx, EAC, etc. Additional Requirements / Comment