6012 BURKERT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 14

Technical content

Visit product website  DATA SHEET DATA SHEET Type 2507  Cable plug - industry standard plug Form B Type 2516  Cable plug DIN EN 175301-803 - form C 1000011028 | Standard | EU | en | 202101 | 14 Plunger valve 3/2 way direct-acting

  • Direct-acting, compact small-format valve with diameter of up to DN 1.6
  • Screwed coil system
  • Banjo threaded connection for direct mounting on pneumatic valves
  • Simple and quick push-in, flange, or manifold installation
  • Service-friendly manual override Valve 6012 is a direct-acting plunger valve. The stopper and plunger guide tube are welded together to enhance pressure resistance and leak-tightness. Various seal material combinations are available depending on the applica- tion. A Bürkert-specific flange design (SFB) enables space-saving arrange- ment of valves on a manifold. Push-in fittings can be selected for flexible hose connection. A banjo connection with banjo bolt is the ideal solutio n for easy direct mounting on a pneumatic drive. Optional manual actuation enables quick commissioning and optimal maintenance. In combination with a cable plug in accordance with industry standard Form B or DIN EN 17301-803 Form C, the valves satisfy protection class IP65. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 6012 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 14 Visit product website  Table of contents 1. Gener al Technical Data 3 Cir cuit functions Materials 3.2. Material specifications Standard version Banjo version 4. Dimensions 6 Version acc. to DIN EN 175301 803 Form C (cable plug Type 2516) PIN Assignments Version acc. to industry standard connector Form B for cable plug Type 2507 4.2. Banjo version Version acc. to DIN EN 175301 803 F orm C for cable plug Type 2516 Version acc. to industry standard connector Form B for cable plug Type 2507 4.3. Multiple manifold 5. Performance specifications 9 Standard version Banjo version 6. Ordering information 9 6.2. Bürkert product filter 6.3. Or dering chart Standard version Banjo version 6.4. Or dering chart accessories Multiple manifold Accessories for manifolds Cable plug Type 2516 acc. to DIN EN 175301 803 F orm C Cable plug Type 2507 acc. to industry standard connector Form B

3 | 14 Visit product website  1. Gener al Technical Data Product properties Dimensions Detailed information can be found in chapter “4. Dimensions” on page 6. Material Body Brass, polyamide (PA), stainless steel 1.4305 Seal FKM, NBR Weight Standard version 125 g Banjo version 135 g Thermal insulation class of solenoid Polyamide: class B Epoxy: class H Manual override Optional, as a standard feature (for Type 6012, banjo version) Performance data Duty cycle/single valve for block assembly on multiple manifold 100 % continuous r ating Intermittent operation (30 min) With 2 W coil 100 (on request) Response times1.) Standard version DN 1.2 mm: Opening 7…10 ms, Closing 9…12 ms DN 1.6 mm: Opening 7…12 ms, Closing 7…12 ms Banjo version DN 1.2 mm, 4 W AC: Opening 7…10 ms, Closing 9…12 ms DN 1.2 mm, 4 W DC: Opening 7…12 ms, Closing 7…12 ms Circuit function C and D (see “2. Circuit functions” on page 4) Electrical data Operating voltage 24 V DC, 24 V

50 Hz,

Voltage tolerance ± Medium data Viscosity (max.) 21 mm2/s Medium Neutral gases and liquids (e.g. compressed air, water, hydraulic oil, technical Vacuum) Medium temperature Standard version - °C… 100 Banjo version - °C… Appr ovals and certificates Degree of protection IP65 with cable plug Process/Port connection & communication Port connection Standard version M5, G Flange Banjo version G G and tube fitting Ø 6 mm Electrical connection • Acc. to DIN EN 175301 803 Form C for cable plug Type 2516 (see “6.4. Ordering chart accessories” on page 13)

  • Acc. to industry standard connector Form B for cable plug Type 2507 (see “6.4. Ordering chart accessories” on page 13)
  • Flying leads on request Environment and installation Installation instructions As required, preferably with actuator upright Ambient temperature Standard version Max. Banjo version - °C… 1.) Response times [ms]: Measures at valve outlet at 6 bar and + 20 °C acc. to ISO 12238, opening: pressure build up 0 to 90 %, closing: pressure relief 100 to 10 %

4 | 14 Visit product website  2. Cir cuit functions Circuit functions Description 2(A) 1(P) 3(R) Type: C, solenoid valve 3/2 way Direct-acting Normally closed 2(B) 1(P) 3(R) Type: D, solenoid valve 3/2 way Direct-acting Normally opened 3. Mat erials 3.1. Chemical Resistance Char t – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? V erify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check 3.2. Mat erial specifications Standard version No. Element Material

1 Pressure inlet P With circuit function D

2 Locknut DIN

(surface Zn5glcA) 3 Stopper Stainless steel 1.4105

4 Shading ring Copper

(silver optional) 5 Core Stainless steel 1.4105 6 Guide tube Stainless steel 1.4303 7 Spring Stainless steel 1.4310

8 O-Ring FKM/EPDM

9 Armature seal FKM/EPDM

10 Pressure inlet P With circuit function C

11 Body Brass, stainless steel 1.4305 PA (polyamide)

12 Sub-base Zn3

(brass version) Nickel-plated surface (St. st. version)

13 Coil DIN EN 175301

orm C: PA Industry standard connector Form Epoxy

5 | 14 Visit product website  Banjo version No. Element Material (surface Zn5glcA) 3 Stopper Stainless steel 1.4105 (silver optional) 5 Core Stainless steel 1.4105 6 Guide tube Stainless steel 1.4303 7 Spring Stainless steel 1.4310

8 O-Ring FKM

9 Spring Stainless steel 1.4310

10 Armature seal FKM

11 Pressure inlet P With circuit function C

12 Banjo bold Nickel-plated brass

13 Sub-base Zn3

(brass version) Nickel-plated surface (St. st. version)

14 Coil DIN EN 175301

orm C: PA Industry standard connector Form Epoxy

15 Hand lever Durethan

16 Body PA

(polyamide)

6 | 14 Visit product website  4. Dimensions 4.1. S tandard version Version acc. to DIN EN 175301 - 803 F orm C (cable plug Type 2516) Note: Dimensions in mm 4.7 32.5 4x M3.6 deep 20 C 14.75 A B D X X 20 4.7 ** ** D Port connection A B C D Thread M5 5 20 14 Thread G ⅛ 8 25 19.5 Sub-base – – 20 11 PIN Assignments For the positions marked with *, or * in the drawing, the connections are marked with the letters shown in the table above, de- pending on the circuit function. Unused connections in circuit functions A or B will be closed off with a blanking plug or cap nut. Circuit function Connection Type A P to lock A B to lock B P C P R A D R P B T P R A

7 | 14 Visit product website  Version acc. to industry standard connector Form B for cable plug Type 2507 Note: Dimensions in mm 6.4 8.9 3.1 14.75 10.6 Port connection A B C D Thread M5 5 20 14 Thread G ⅛ 8 25 19.5 Sub-base – – 20 11 4.2. Banjo version Version acc. to DIN EN 175301 - 803 F orm C for cable plug Type 2516 Note:

  • Dimensions in mm
  • Push-in connection for compressed air: Pressure inlet P can be rotated through 360°. Threaded port for compressed air Push-in connection for compressed air G L 47 R10 G SW17 3.5 54 25.3 R10 G L 6 P 3.5 G L G ⅛ 6.5 G ¼ 9.5

8 | 14 Visit product website  Version acc. to industry standard connector Form B for cable plug Type 2507 Note: Dimensions in mm Threaded port for compressed air Push-in connection for compressed air 54 20 54 20 G L G ⅛ 6.5 G ¼ 9.5 4.3. Multiple manifold Note:

  • Dimensions in mm
  • Made of aluminium, anodized
  • Can only be combined with versions Circuit function C (normally closed) A Ø7.2 4.3 10 21 G1/8 C 10 21 2.5 B C No. of valves A B C Article no. [mm] [mm] [mm] 1 20 12 – 005312  2 41 33 – 005355  3 62 54 – 005313  4 83 75 – 005314  5 104 96 – 005315  6 125 117 – 005316  7 146 138 – 005893  8 167 159 54 005166  9 188 180 54 005241  10 209 201 75 005819  11 230 222 75 005242  12 251 243 96 005222 

9 | 14 Visit product website  5. P erformance specifications 5.1. P ower consumption Standard version Orifice KV value water Pressure range Coil power Power consumption Response times 3.) Circuit function C Circuit function D Inrush Hold Opening Closing [mm] [m 3/h]1.) [bar]2.) [bar]2.) [ms] [ms] 1.2 0.045 0…10 0…10 4 W AC or 4 W DC 9 VA 6 VA (4 W) 7…10 9…12 1.6 0.06 0…6 0…6 4 W 4 W 7…12 7…12 1.) KV value: Flow rate value for water, measurement at + 20 °C, 1 bar2.) pressure at valve inlet and free outlet. 2.) Pressure data: Overpressure with respect to atmospheric pressure 3.) Response times: Measures at bar2.) and + 20 °C at valve outlet acc. to ISO 12238. Opening: pressure build up 0 to 90 %, closing: pressure relief 100 to 10 % Banjo version Nennweite Q Nn-Wert Luft Druckbereich Spulenleistung Elektr. Leistung Schaltzeiten 3.) Anzug Betrieb Öffnen Schließen [mm] [l/min] 1.) [bar]2.) [ms] [ms] 1.2 48 0…10 4 W AC oder 4 W DC 9 VA 6 VA (4 W) 7…10 9…12 0…6 4 W 4 W 7…12 7…12 1.) QNn value: Flow rate value for air, measured at + 20 °C, 6 bar2.) pressure at valve inlet and 1 bar pressure difference 2.) Pressure data: Overpressure with respect to atmospheric pressure 3.) Response times: Measures at bar2.) and + 20 °C at valve outlet acc. to ISO 12238. Opening: pressure build up 0 to 90 %, closing: pressure relief 100 to 10 % 6. Or dering information 6.1. Bürk ert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and fast delivery You want to find your desired Bürkert product or spare part quickly and order dir ectly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 6.2. Bürk ert product filter Bürkert product filter – Get quickly to the right product Y ou want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily Try out our product filter

10 | 14 Visit product website  6.3. Or dering chart Standard version Note:

  • All valves with FKM seal and without cable plug
  • Further versions on request Circuit function Orifice Port con- nection KVvalue water Pressure range Voltage/ frequency Article no. Brass body without manual override Article no. Brass body with manual override Article no. St. st. body without manual override Article no. PA body with manual override [mm] [m 3/h] [bar] 1.) [V/Hz] Solenoid valve in threaded port or sub-base version with polyamide electrical coil acc. to DIN EN 175301 803 F orm C for cable plug Type 2516 C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R) 1.2 M5 0.045 0…10 24/DC 134143  – – – 24/50 134144  – – – 110/50 134145  – – – 230/50 134146  – – – 1.6 M5 0.06 0…6 24/DC 134147  – – – 24/50 134148  – – – 110/50 134149  – – – 230/50 134150  – – – 1.2 G ⅛ 0.045 0…10 24/DC 134151  134159  134167  – 24/50 134152  134160  134168  – 110/50 134153  134161  134169  – 230/50 134154  134162  134170  – 1.6 G ⅛ 0.06 0…6 24/DC 134155  134163  134171  – 24/50 134156  134164  134172  – 110/50 134157  134165  134173  – 230/50 134158  134166  134174  – 1.2 Sub-base 0.045 0…10 24/DC 134175  – 134183  134191  24/50 134176  – 134184  134192  110/50 134177  – 134185  134193  230/50 134178  – 134186  134194  1.6 Sub-base 0.06 0…6 24/DC 134179  – 134187  134195  24/50 134180  – 134188  134196  110/50 134181  – 134189  134197  230/50 134182  – 134190  134198  D, solenoid valve 3/2 way Direct-acting Normally opened 2(B) 1(P) 3(R) 1.2 M5 0.045 0…10 24/DC 134199  – – – 24/50 134200  – – – 110/50 134201  – – – 230/50 134202  – – – 1.6 M5 0.06 0…6 24/DC 134204  – – – 24/50 134205  – – – 110/50 134206  – – – 230/50 134207  – – – 1.2 G ⅛ 0.045 0…10 24/DC 134208  – 134216  – 24/50 134209  – 134217  – 110/50 134210  – 134218  – 230/50 134211  – 134219  – 1.6 G ⅛ 0.06 0…6 24/DC 134212  – 134220  – 24/50 134213  – 134221  – 110/50 134214  – 134222  – 230/50 134215  – 134223  – 1.) Pressure data: Overpressure with respect to atmospheric pressure

11 | 14 Visit product website  Circuit function Orifice Port con- nection KVvalue water Pressure range Voltage/ frequency Article no. Brass body without manual override Article no. Brass body with manual override Article no. St. st. body without manual override Article no. PA body with manual override [mm] [m 3/h] [bar] 1.) [V/Hz] Solenoid Valve with threaded port or sub-base version with polyamide electrical coil acc. to industry standard connector Form B for cable plug Type 2507 C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R) 1.2 M5 0.045 0…10 24/DC 163569  – – – 24/50 163570  – – – 110/50 163571  – – – 230/50 163572  – – – 1.6 M5 0.06 0…6 24/DC 163573  – – – 24/50 163574  – – – 110/50 163575  – – – 230/50 163576  – – – 1.2 G ⅛ 0.045 0…10 24/DC 161904  163584  163592  – 24/50 163577  163585  163593  – 110/50 163578  163586  163594  – 230/50 163579  163587  163595  – 1.6 G ⅛ 0.06 0…6 24/DC 163580  163588  163596  – 24/50 163581  163589  163597  – 110/50 163582  163590  163598  – 230/50 163583  163591  163599  – 1.2 Sub-base 0.045 0…10 24/DC 163600  – 163608  161063  24/50 163601  – 163609  163616  110/50 163602  – 163610  163617  230/50 163603  – 163611  163618  1.6 Sub-base 0.06 0…6 24/DC 163604  – 163612  163619  24/50 163605  – 163613  163620  110/50 163606  – 163614  163621  230/50 217634  – 163615  163622  D, solenoid valve 3/2 way Direct-acting Normally opened 2(B) 1(P) 3(R) 1.2 M5 0.045 0…10 24/DC 163623  – – – 24/50 163624  – – – 110/50 163625  – – – 230/50 163626  – – – 1.6 M5 0.06 0…6 24/DC 163627  – – – 24/50 163628  – – – 110/50 163629  – – – 230/50 163630  – – – 1.2 G ⅛ 0.045 0…10 24/DC 163631  – 163639  – 24/50 163632  – 163640  – 110/50 163633  – 163641  – 230/50 163634  – 163642  – 1.6 G ⅛ 0.06 0…6 24/DC 163635  – 163643  – 24/50 163636  – 163644  – 110/50 163637  – 163645  – 230/50 163638  – 163646  – 1.) Pressure data: Overpressure with respect to atmospheric pressure

12 | 14 Visit product website  Banjo version Note:

  • All valves with PA body, NBR seal and manual override and without cable plug
  • F urther versions on request Circuit function Orifice Pressure inlet P (valve body) Service port A (banjo bolt) Q Nn value air Pressure range Voltage/ fr equency Article no. [mm] [l/min] [bar] 1.) [V/Hz] Banjo version complete for direct mounting on pneumatic actuator with polyamide coil acc. to DIN EN 175301 803 F orm C for cable plug Type 2516 C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R)

1.2 G ⅛ G ⅛ 48 0…10 24/DC 429112 

24/50 429113  110/50 429115  230/50 429117  G ¼ G ⅛ 48 0…10 24/DC 429126  24/50 429127  110/50 429128  230/50 429129  G ¼ G ¼ 48 0…10 24/DC 427919  24/50 427920  110/50 427921  230/50 427922  Tube fitting Ø 6 mm G ⅛ 48 0…10 24/DC 425299  24/50 425300  110/50 428570  230/50 425304  Tube fitting Ø 6 mm G ¼ 48 0…10 24/DC 425285  24/50 425286  110/50 428569  230/50 425290  Banjo version complete for direct mounting on pneumatic actuator with epoxy coil acc. to industry standard connector Form B for cable plug Type 2507 C, solenoid valve 3/2 way Direct-acting Normally closed 2(A) 1(P) 3(R)

1.2 G ⅛ G ⅛ 48 0…10 24/DC 552299 

24/50 552300  110/50 552301  230/50 552302  G ¼ G ⅛ 48 0…10 24/DC 552295  24/50 552296  110/50 552297  230/50 552298  G ¼ G ¼ 48 0…10 24/DC 552291  24/50 552292  110/50 552293  230/50 552294  Tube fitting Ø 6 mm G ⅛ 48 0…10 24/DC 552287  24/50 552288  110/50 552289  230/50 552290  Tube fitting Ø 6 mm G ¼ 48 0…10 24/DC 552283  24/50 552284  110/50 552285  230/50 552286  1.) Pressure data: Overpressure with respect to atmospheric pressure

13 | 14 Visit product website  6.4. Or dering chart accessories Multiple manifold Note: Detailed order information can be found in chapter “4.3. Multiple manifold” on page 8. Accessories for manifolds Accessory Features Article no. Blanking plug with seal ring, G ⅛ 005041  Cover plate for unused valves 005100  Cable plug Type 2516 acc. to DIN EN 175301 803 F orm C Note:

  • Delivery of cable plug includes a flat seal and a fixing screw.
  • Further versions of cable plug with circuitry acc. to DIN EN 175 301 803 F orm C as well as detailed technical data, see datasheet Type 2516 Cable plug Version Voltage Current Article no. Without circuitry 0…250 V AC/DC Max. 6 A 303141  With LED 12…24 V AC/DC Max.

3 A 303145 

With LED and varistor 12…24 V AC/DC Max.

3 A 303148 

rectifier, LED and varist or 12…24 V AC/DC Max.

1 A 303142 

Cable plug Type 2507 acc. to industry standard connector Form B Note:

  • Delivery of cable plug includes a flat seal and a fixing screw.
  • Further versions of cable plug with circuitry acc. to industry standard connector Form B as well as detailed technical data, see datasheet Type 2507 Cable plug Version Voltage Article no. Without circuitry (standard) 2…250 V A C/DC 423845  With LED 24 V AC/DC 423849  With LED and free-wheeling diode 12…24 V AC/DC 423851  With rectifier, LED and varistor 12…24 V AC/DC 423853 

Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa Russia United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -

74653 Künzelsau

www.burkert.com