5470 BURKERT | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 18
Technical content
Visit product website DATA SHEET Type 2012 Pneumatically operated 2/2-way globe valve CLASSIC Type 2516 Cable plug, form C according to DIN EN 175301 803 Standard | EU | en | 2023 - 10 - 03 | 02 3/2- or 4/2-way solenoid valve for pneumat- ics
- Compact design in 3/2- and 4/2-way versions Extendable valve block Reduced power consumption Different pneumatic connections available Robust construction Valves of type 5470 consist of a type 6106 pilot rocker solenoid valve and a pneumatic valve. An armature with a tilting bearing, similar to a rocker, tilts within the body of the pilot valve, and switches the valve. The minimal tilting movement of the rocker is non-wearing, and basic lubrication is unnecessary. The type 5470 R is available as a 3/2 and 4/2-way valve. The valves can be mounted together individually using the module flange. In various applica- tions, they can be used advantageously as valve blocks. Different variants are available for service ports 2 and 4. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 5470 © Christian Bürkert GmbH & Co. KG, Subject to alteration
2 | 18Visit product website Table of contents 1. General technical data 3 Circuit functions Dimensions 3.2. Dimensions variants for port connection 2 (working ports) 3.3. Dimensions block installation with 18 mm extendable valves on a single base module Structure with connector lugs at side Structure with connector lugs at top 3.4. Dimensions block installation with 19 mm extendable valves on pneumatic modules Type MP05 Structure with connector lugs at side Structure with variant for supply connection with push-in coupling Ø 6 mm and threaded connection G ⅛ 4. Product design and assembly 8 Connection variants for port connection 1 Connection variants for port connection 2 (working ports) Electrical data explosion-proof version Ex ia Electrical connection with plug for extendable valves (cable plug Type 1057 for individual wiring) 4.2. Product structure block installation with 18 mm extendable valves on individual base module Structure with connector lugs at side Structure with connector lugs at top 4.3. Product structure block installation with 19 mm extendable valves on pneumatic modules Type MP05 Structure with connector lugs at side 5. Ordering information 12 5.2. Bürkert product filter 5.3. Ordering chart Extendable single valves with module flange for pressure ports 1 (P) and 3 (R) with connector lugs at top Extendable single valves with module flange for pressure ports 1 (P) and 3 (R) with rectangular electro connection For valve terminal mounting, valves with connector lugs on the side; connection with integrated connector sockets on valve terminals Type 8640 Namur EExi 3/2 and 4/2-way solenoid valve for pneumatic 5.4. Ordering table accessories Connection modules and accessories for valve blocks Cable plug Type 2516, form C according to DIN EN 175301 803 Further accessories
3 | 18Visit product website 1. General technical data Product properties Materials Body Polyamide (PA) Inner valve parts Ultramid Seal material NBR Weight Approx. 120 g Nominal diameter DN 4.0 Nominal operating mode Continuous operation Electrical data Operating voltage 24 V DC / 110…120 V DC / 220…240 V DC For alternating voltage use valves with UC coil Voltage tolerance ± Electrical power consumption Complies with the effective coil power in the ordering table Detailed information can be found in chapter “5. Ordering information” on page 12 Performance data Pressure range 2…10 bar overpressure with respect to atmospheric pressure QNn value air 300 l/min Flow rate value for air, measurement at + °C, 6 bar pressure at the valve inlet and 1 bar pressure difference Electrical nominal power 2…3 W Solenoids with integrated rectifier, LED and varistor (UC variant) solenoids Switching times DC: Opening: 15 ms, closing: 12 ms AC: Opening: 15 ms, closing: 20 ms Measurement at the valve outlet according to ISO 12238 Medium data Operating media Compressed air, neutral gases (5 µm filtration) Medium temperature - 10…+ Approvals and conformity Type of protection Standard version PTB 01 ATEX 2175: II 2 G Ex ia IIC T5, T6 Gb Explosion-proof version IECEx PTB 06.0102: Ex ia IIC T5, T6 Gb Protection class IP65 with leads or cable plug Type 2516 IP30 with cable plug Type 2505 Process/Port connection & communication Electrical connection Connector lugs according to DIN EN 175301 803, Form C, for cable plugs Type 1057 and Type 2516; rectangular plug (5.08) Detailed information can be found in chapter “5.4. Ordering table accessories” on page 16 Pressure ports 1 and 3 Module flange Working ports 2 and 4 (variants) Sleeve G ⅛ Sleeve NPT ⅛ Hose screw connection SL 6/4 mm Plug-in coupling Ø 6 mm Environment and installation Ambient temperature - 10…+ Accessories Installation position Any, preferably actuator face up
4 | 18Visit product website 2. Circuit functions Symbol Description 2(A) 1(P) 3(R) Circuit function C (CF C) 3/2-way solenoid valve Servo-controlled Normally closed 2(B) 1(P) 3(R) Circuit function D (CF D) 3/2-way solenoid valve Servo-controlled Normally open 2(B) 4(A) 1(P) 3(R) Circuit function G (CF G) 4/2-way solenoid valve Servo-controlled 3. Dimensions 3.1. Dimensions variants for port connection 1 Note: Dimensions in mm 16.5 55.2 35.35 19.9 17.1 G 1/8; NPT 1/8 G 1/8 26 16.5 55.2 35.35 19.9 3.2. Dimensions variants for port connection 2 (working ports) Note: Dimensions in mm 34.6 14 55 26.2 G 1/8; NPT 1/8 48.1 12.5 41.1 48.6 G 1/8 15 47.2 G 1/8; NPT 1/8 48.1 64.1 69.1 17.5 24 29.5
5 | 18Visit product website 3.3. Dimensions block installation with 18 mm extendable valves on a single base module Structure with connector lugs at side Note: Dimensions in mm Electrical connection rectangular plug with 2 pins (cable plug Type 2505 cable and wire version) 26.5 22 18 18 36 + ( n x 18 ) 122 13 + ( n x 18 ) G1/8; NPT1/8 Block installation n = number of valves 35.35 19.85 34.6 6.5 Depending on working port 122 0.63 15.5 5.08 29.9 Single valve
6 | 18Visit product website Structure with connector lugs at top Note: Dimensions in mm 803) 35.35 19.85 153.3 45.65 Depending on working port 121.85 15.5 26.5 22 18 18 36 + ( n x 18 ) 6.5 6.5 13 + ( n x 18 ) G1/8; NPT1/8 121.8 11.5 32.5 55.15 33.65 27.5 4.5 7.6 Depending on working port Single valve Block installation n = number of valves 3.4. Dimensions block installation with 19 mm extendable valves on pneumatic modules Type MP05 Structure with connector lugs at side Note: Dimensions in mm 6.5 6.5 13 + ( n x 19 ) 56 + ( n x 19 ) 24.5 26 G1/4; NPT1/4 115.45 9.5 19 19 n = number of valves Depending on working port 35.5 55.15 11.5 33.65 32.5 4.5 7.6
7 | 18Visit product website Structure with variant for supply connection with push-in coupling Ø 6 mm and threaded connection G ⅛ Note Banjo bolts as throttle check valve 26.1 44.1 76.2 (115.35) 15.5 17.6 29.6 3212 17.1 35 48.1 64.1 69.1 9.6 Ø 4.3 17.5 32.1 17.5 24 48.1 SW 17 9.2 9.3 27.2 32.1 17.5 Ø 5
8 | 18Visit product website 4. Product design and assembly 4.1. Product structure servo-assisted valve No. Element
1 Manual override
2 Port connection 2
3 Working port 2 (B)
4 Working port 4 (A)
5 Pressure supply 1 (P)
6 Port connection 1
(FM07 = not equipped)
7 Exhaust 3 (R)
8 Amplifier
9 Pilot control standard
Connection variants for port connection 1 Circuit function C, D, G LTA1 = port connection 1 Base module Base module with check valve in R channel Plug-in coupling Ø 6 mm Sleeve G 1/8 or NPT 1/8 Hose screw connection SL 6/4 mm
9 | 18Visit product website Connection variants for port connection 2 (working ports) Note: The corresponding properties of the connection variants can be found in the table at the end of the chapter. Variant B Plug-in coupling Ø 6mm Variant A Variant B G 1/8 or NPT 1/8 Variant C Variant D Variant E Variant F Variant G Circuit function G Circuit function C Circuit function D LTA2 = port connection 2 Namur Namur for throttle screws Variant B G 1/8 or NPT 1/8 Variant B Plug-in coupling Ø6 mm Variant D Variant E Variant F Variant C (code AF07) Namur Namur for throttle screws Variant E Variant A Variant C (code AF07) Variant Properties Variant A Plug-in coupling Ø 6 mm at bottom (circuit function C) Variant B Plug-in coupling Ø 6 mm at side and sleeve G ⅛ or NPT ⅛ with throttle check valve Variant C Plug-in coupling Ø 6 mm at bottom (circuit function D+G) Variant D Hose screw connection SL 6/4 mm at side Variant E Plug-in coupling Ø 6 mm at side Variant F Sleeve G ⅛ or NTP ⅛ at side Variant G Namur flange or Namur flange for throttle screws
10 | 18Visit product website Electrical data explosion-proof version Ex ia Note: The valve is designed to operate on 24 V DC outputs through an intermediary intrinsically safe apparatus (isolating block or barri er). Please refer to the additional instructions Type AC21 ATEX 2175 for the permissible maximum values/value pairs. Type of protection: PTB 01 ATEX 2175: II 2 G Ex ia IIC T5,T6 Gb IECEx PTB 06.0102: Ex ia IIC T5,T6 Gb SPS/ PLC Barriere/ isolating component
24 V DC ≥ Umin
+≥ lmin+ Version Resistance at 20 °C ± 4 % Minimum terminal voltage Minimum current [Ω] [V] [mA] For use with a 30 Ω supply module 320 9.3 29 High resistance version 475 10.9 23 Electrical connection with plug for extendable valves (cable plug Type 1057 for individual wiring) Cable plug Type 1057 can be selected with plug configuration at top (see “Connection variants for port connection 2 (working ports)” on page 9 ). The main prerequisite is that the base module is selected for width/station 18 mm. Neutral and protective conductors are looped through and connected centrally once. When connecting the valves, only the control line to each valve must be installed. The neutral and protective conductors are integrated in the cable plug. The major advantage of this system is that a valve can be removed from the block without difficulty. Note: The cable plug Type 1057 is available only in conjunction with the individual base module width/station 18 mm. Block installation with extendable valves Cable plug Type 1057
11 | 18Visit product website 4.2. Product structure block installation with 18 mm extendable valves on individual base module Structure with connector lugs at side 1 2 3 4 5 No. Element
1 Connection module on left
2 Extendable valves
3 Intermediate feed
(for different pressures)
4 Extendable valves
5 Connection module on
Structure with connector lugs at top 1 2 3 4 5 No. Element (for different pressures)
12 | 18Visit product website 4.3. Product structure block installation with 19 mm extendable valves on pneumatic modules Type MP05 Structure with connector lugs at side Note: Variant with connector lugs at top: Individual wiring also possible 803) 1 2 3 4 5 No. Element
1 Connection module, on left
2 Base module, 3x Type MP05
3 Connection module on right as
intermediate module (supply channels pushed through or sealed; different pressure supply P1, P2…is possible)
4 Base module, 2x Type MP05
5 Connection module, on right
6 Exhaust channel: 3 (R)
7 Supply channel: 1 (P)
- Ordering information 5.1. Bürkert eShop Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 5.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter
13 | 18Visit product website 5.3. Ordering chart Extendable single valves with module flange for pressure ports 1 (P) and 3 (R) with connector lugs at top Note: Further variants on request Delivery does not include cable plug (see “5.4. Ordering table accessories” on page 16 Details on the illustrated circuit functions see “2. Circuit functions” on page 4 18 mm stackable valves with individual basic modules, see “Electrical data explosion-proof version Ex ia” on page 10 The following applies to all the variants listed below: Nominal width: 4.0 mm QNn value air: 300 l/m Pressure range: 2…10 bar Circuit function Working ports 2 and 4 Voltage/F requency [V/Hz] Effective coil power [W] Article no. DC coil 2.) Article no. UC coil 3.) CF C 3/2-way solenoid valve Servo-controlled Normally closed 1.) 2(A) 1(P) 3(R) Plug-in coupling Ø 6 mm at bottom with check valve (Variant A) 24/DC/UC 2 136872 – 110…120/DC 3 136873 145970 220…240/DC 3 136874 145971 CF D 3/2-way solenoid valve Servo-controlled Normally open 1.) 2(B) 1(P) 3(R) Plug-in coupling Ø 6 mm at bottom with check valve (Variant C) 24/DC 2 136875 – 110…120/DC 3 136876 – 220…240/DC 3 – – CF G 4/2-way solenoid valve Servo-controlled 2(B) 4(A) 1(P) 3(R) Hose screw connection at side 6/4 (Variant D) 24/DC/UC 2 136878 – 220…240/DC/UC 3 136880 – G ⅛ at side (Variant E) 24/DC/UC 2 136881 – 110…120/DC/UC 3 136882 220…240/DC/UC 3 136883 145980 G ⅛ at side with Throttle check valve (Variant B) 24/DC/UC 2 136884 – 110…120/DC/UC 3 – 145982 220…240/DC/UC 3 136886 145983 Plug-in coupling Ø 6 mm at side (Variant F) 24/DC/UC 2 136887 – 110…120/DC/UC 3 136888 – 220…240/DC/UC 3 136889 145986 Plug-in coupling Ø 6 mm at bottom (Variant C) 24/DC/UC 2 136890 – 110…120/DC/UC 3 136891 145988 220…240/DC/UC 3 136892 145989 1.) 3/2-way variants (circuit functions C and D) with check valve in the module flange (in R channel) 2.) Only for direct current operation (DC), for alternating current (AC) connect cable plug upstream with rectifier 3.) For universal current operation (UC = DC or AC); rectifier, varistor and LED are integrated in the coil
14 | 18Visit product website Extendable single valves with module flange for pressure ports 1 (P) and 3 (R) with rectangular electro connection Note: Further variants on request Delivery does not include cable plug (see “5.4. Ordering table accessories” on page 16 Details on the illustrated circuit functions see “2. Circuit functions” on page 4 18 mm stackable valves with individual basic modules, see “Electrical data explosion-proof version Ex ia” on page 10 The following applies to all the variants listed below: Nominal width: 4.0 mm QNn value air: 300 l/m Pressure range: 2…10 bar Circuit function Working ports 2 and 4 Voltage/F requency [V/Hz] Effective coil power [W] Article no. DC coil CF C 3/2-way solenoid valve Servo-controlled Normally closed 1.) 2(A) 1(P) 3(R) Plug-in coupling Ø 6 mm at bottom with check valve (Variant A) 24/DC 2 145993 2.) CF G 4/2-way solenoid valve Servo-controlled 2(B) 4(A) 1(P) 3(R) G ⅛ at side with throttle check valve (Variant B) 24/DC 2 145997 2.) Plug-in coupling Ø 6 mm at side (Variant F) 24/DC 2 145998 2.) Plug-in coupling Ø 6 mm at bottom (Variant C) 24/DC 2 145999 2.) 1.) 3/2-way variants (circuit functions C and D) with check valve in the module flange (in R channel) 2.) Only for direct current operation (DC), for alternating current (AC) connect cable plug upstream with rectifier
15 | 18Visit product website For valve terminal mounting, valves with connector lugs on the side; connection with integrated connector sockets on valve terminals Type 8640 Circuit function Pressure range [bar] Working ports 2 and 4 Voltage/ Frequency [V/Hz] Effective coil power [W] Article no. Connector lugs via pressure input Article no. Connector lugs via pressure output CF C 3/2-way solenoid valve Servo-controlled Normally closed 2(A) 1(P) 3(R) 2…8 Plug-in coupling Ø 6 mm, below (Variant A) 24/DC 1 132479 135203 2…10 24/DC 2 133148 135204 2…10 110…120/DC 3 – 132952 2…10 220…240/DC 3 – 132953 CF D 3/2-way solenoid valve Servo-controlled Normally open 1.) 2(B) 1(P) 3(R) 2…8 Plug-in coupling Ø 6 mm (Variant C) 24/DC 1 132481 136742 2…10 24/DC 2 136741 136743 2…10 110…120/DC 3 – 136744 2…10 220…240/DC 3 – 136745 CF G 4/2-way solenoid valve Servo-controlled 2(B) 4(A) 1(P) 3(R) 2…8 Plug-in coupling Ø 6 mm, in front (Variant E) 24/DC 1 132487 135205 2…10 24/DC 2 133149 135206 2…10 110…120/DC 3 – 132954 2…10 220…240/DC 3 – 132955 2…10 Plug-in coupling Ø 6 mm, below (Variant C Code AF07) 24/DC 2 133150 135208 2…10 110…120/DC 3 132956 2…10 220…240/DC 3 132957 2…10 Plug-in coupling Ø 6 mm, in front, with throttle check valve (Variant B) 24/DC 2 133151 135210 2…10 110…120/DC 3 – 133152 2…10 220…240/DC 3 – 133153 2…10 Thread G ⅛, in front, (Variant F) 24/DC 2 133157 135212 2…10 110…120/DC 3 – 132958 2…10 220…240/DC 3 – 132959 2…10 Thread G ⅛, in front, with throttle check valve (Variant B) 24/DC 2 133159 135214 2…10 110…120/DC 3 – 133160 2…10 220…240/DC 3 – 133161 2…10 Hose screw connec- tion, SL6/4 mm, in front (Variant D) 24/DC 2 133163 135215 2…10 110…120/DC 3 – 133164 2…10 220…240/DC 3 – 133166
16 | 18Visit product website Namur EExi 3/2 and 4/2-way solenoid valve for pneumatic Note: All valves with tag connector on top; without cable plug Working ports 2 and 4 Namur flange Circuit function Nominal diameter [mm] QNn value air [I/min] Pressure range [bar] Feature Supply ports 1 and 3 Article no. CF C 3/2-way solenoid valve Servo-controlled Normally closed 2(A) 1(P) 3(R) 4.0 300 2…8 None Thread G ⅛, Variant 5 139224 Plug-in coupling Ø 6 mm, Variant 6 139402 CF G 4/2-way solenoid valve Servo-controlled 2(B) 4(A) 1(P) 3(R) 4.0 300 2…8 With throttle check valve Thread G ⅛, Variant 5 139407 Plug-in coupling Ø 6 mm, Variant 6 139408 5.4. Ordering table accessories Connection modules and accessories for valve blocks Variant Port connection valve block Article no. Connection module on left G ⅛ 133175 G ¼ 132512 NPT ¼ 132513 Plug-in coupling Ø 8 mm 623755 Plug-in coupling Ø 10 mm 623762 Connection module on right G ⅛ 133177 G ¼ 132514 Plug-in coupling Ø 8 mm 623770 Plug-in coupling Ø 10 mm 623784 NPT ¼ 132515 Intermediate feed G ⅛ 627742 G ¼ 631288 Plug-in coupling Ø 8 mm 631287 Plug-in coupling Ø 10 mm 631290 Lock screw G ⅛ 631019 G ¼ 631020 MP05 base module 2x Without check valve 132516 With check valve in R channel 132518 MP05 base module 3x Without check valve 132517 With check valve in R channel 132519 Sealing plug Ø 6 mm 015397 Ø 8 mm 900065 Protective cover For unused valve slots 643223
17 | 18Visit product website Cable plug Type 2516, form C according to DIN EN 175301 - 803 Note: Delivery of cable plug includes a flat seal and a fixing screw. For further versions see data sheet Type 2516 Cable plug Dimensions Version Voltage Article no. 15.8 28 approx. 10 Ø 15 M2.5 (1.5) 15.8 (16.8)max. 3.4 -1 3.6 -1 Without circuitry 0…250 V AC/DC 303141 With LED 12…24 V AC/DC 303145 With LED and varistor 12…24 V AC/DC 303148 With rectifier, LED and varistor 12…24 V AC/DC 303142 Further accessories Description Article no. 3x extendable cable plug Type 1057-SA, IP20, with looped-through neutral and protective conductors (only for
24 V DC)
629253 Control line with AMP plug length 540 mm 629181 Standard rail 300 mm for block 8…12-fold with intermediate feed (ZE) or for block 8…14-fold without ZE 640789 Standard rail 408 mm for block 13…17-fold with intermediate feed (ZE) or for block 15…19-fold without ZE 640788 Standard rail 498 mm for block 17…22-fold with 2 intermediate feeds (ZE) or for block 18…23-fold without 1 ZE 630579
Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -
74653 Künzelsau
www.burkert.com