5411 BURKERT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 14

Technical content

Visit product website  DATA SHEET Type 2518  Cable Plug DIN EN 175301 803 - F orm A Type 1087  Timer Type 2513  Cable plug acc. to DIN EN 175301 803 F orm A 1000011018 | Standard | EU | en | 202202 | 07 3/2 way solenoid valve for pneumatic applica- tions

  • Robust servo-piston valve
  • Service-friendly manual override
  • Single or block assembly
  • Explosion-proof versions available Type 5411 is a pilot operated 3/2 way solenoid valve with manual override as standar The body includes a servo piston with the seat seals. Through pilot channels, the servo piston is either loaded with input pressure or released. A minimum pressure difference of 1 bar is required for switching. The vent por t is integrated as a sintered bronze silencer directly in the valve body. The valves can be combined (up to valves) on a single-channel manifold with common pr essure supply. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 5411 © Christian Bürkert GmbH & Co. KG, Subject to alteration Type 5411: available until August 2023

2 | 14 Visit product website  Table of contents 1. Gener al Technical Data 3 P roduct versions 2.2. A TEX/IECCEx version 3. Cir cuit functions 5 3.2. Circuit function Type: solenoid valve 4. Materials 6 4.2. Material specifications 5. Dimensions 7 5.2. Ex m version Version with 3 m moulded cable Version with junction box 6. P roduct installation 9 7. P roduct accessories 9 7.2. Special tool to turn the junction box 8. Or dering information 10 8.2. Bürkert product filter 8.3. Ordering chart Standard version with manual override and NBR seal Ex m version with manual override, NBR seal and moulded 3 m cable Ex me version with manual override, NBR seal and terminal box 8.4. Ordering chart accessories Cable plug Type 2518, Form A according to DIN EN 175301 803 Cable plug Type 2513, Form A according to DIN EN 175301 803 Single-channel manifold blocks Accessories for ATEX/IECEX terminal box

3 | 14 Visit product website  1. Gener al Technical Data Product properties Dimensions Detailed information can be found in chapter “5. Dimensions” on page 7. Material Body Polyamide (reinforced) with moulded-in brass threads Coil Polyamide, Epoxy Seal NBR Nominal diameter DN 6.0 mm Performance data Compressed air quality ISO 8573 1:2010, class 7.4.41.) Flow (QNn value air) 900 l/min (measured at + 20 °C, 6 bar pressure at valve inlet and 1 bar pressure difference) Nominal operating mode 100 % ED continuously r ated Switching times2.) Opening 50 ms pressure rise 0…90 % Closing 30 ms pressure drop 100…10 Electrical data Oper ating voltage 24 V DC 24/110/230 V, 50…60 Hz Power consumption (max.) Version with V DC: 2 W Version with V AC: 11 VA (inrush), 6 VA (hold) Voltage tolerance ± Medium data Type of medium Neutral medium, e.g. lubricated or unlubricated compressed air Medium temperature - °C…+ P rocess/Port connection & communication Port connection size G Electrical connection Tag connectors according to DIN EN 175 301 803 F orm A for cable plug Type 2518 Detailed information can be found in chapter “Cable plug Type 2518, Form A accord- ing to DIN EN 175301 803” on page 12. Approvals and certificates Degree of protection IP65 with cable plug Environment and installation Installation position As required, preferably with solenoid system upright; air exhausted from the relief port with pressed sintered bronze silencer must not be impeded Ambient temperature 55 1.) To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. 2.) Measured at °C, 6 bar pressure at valve inlet and 1 bar pressure difference.

4 | 14 Visit product website  2. P roduct versions 2.1. S tandard version Product properties Dimensions Detailed information can be found in chapter “5.1. Standard ver- sion” on page 7. Electrical data Operating voltage 24 V DC 24/110/230 V, 50…60 Hz Power consumption Inrush AC: 11 VA Hold (hot coil) AC: 6/2 VA/W DC: 2 W Voltage tolerance + P rocess/Port connection & communication Port connection size G Electrical connection Tag connectors according to DIN EN 175 301 803 F orm A for cable plug Type 2518 Detailed information can be found in chapter “Cable plug Type 2518, Form A according to DIN EN 175301 803” on page 12. Environment and installation Installation position As required, preferably with solenoid system upright; air exhausted fr om the relief port with pressed sintered bronze silencer must not be impeded. Ambient t emperature (max.) 55 2.2. A TEX/IECCEx version Note: The approval Ex m is achieved by the mounting of an approved push-over coil. The cable connection and the cable are non-detacha- ble and sealed together with the valve. The valves can be used individually or in blocks. Product properties Dimensions Detailed information can be found in chapter “5.2. Ex m version” on page 8. Electrical data Operating voltage 24/110/230 V UC Voltage tolerance + P rocess/Port connection & communication Port connection size G Electrical connection 3 m cable, moulded Junction box (without fuse) Approvals and certificates Type of protection (ATEX and IECEx) With moulded cable EPS 18 ATEX 1232 X / IECEx EPS 18.0110X II Ex mb IIC (T4/T5/T6) Gb II Ex mb IIIC T (130 °C/95 °C/80 °C) Db With junction box EPS 16 ATEX 1046 X / IECEx EPS 16.0021 X II EX eb mb IIC (T4/T5/T6) Gb II EX mb tb IIIC (130 °C/ °C/ °C) Db Environment and installation Installation position As required, preferably with actuator upright Ambient temperature Single mounting: °C…+ Block mounting: °C…+

5 | 14 Visit product website  3. Cir cuit functions Circuit functions Description 2(A) 1(P) 3(R) Type: C, solenoid valve 3/2 way servo-controlled normally closed 2(B) 1(P) 3(R) Type: D, solenoid valve 3/2 way servo-controlled normally open 3.1. Cir cuit function Type: C, solenoid valve Overview Description Position power-off: The space below the piston is normally relived to the outside via the pilot valve. The compressed air from the connection (P) pushes the piston downward and closes the upper seat, the connection (A) is relieved via the lower seat. Position after switching on the current: The pilot valve opens the pilot bore and exposes the piston from below to pr essure. Through the large surfaces on the actuation side, the piston is push- es up, closes the lower seat, and opens the connection from (P) to (A) through the upper seat. 3.2. Cir cuit function Type: D, solenoid valve Overview Description Position power-off: Without current, the space below the piston is relieved to the outside via the pilot valve. The compressed air from port (P) pushes the piston down and closes the upper seat, port (A) is relieved above the lower seat. Position after switching on the current: When switching on, the pilot valve opens the control bore and applies pressure t o the servo piston from below. Due to the large surfaces on the actuating side, the piston is pushed upwards, closes the lower seat and opens the connection fr om (P) to (A) via the upper seat.

6 | 14 Visit product website  4. Mat erials 4.1. Chemical Resistance Char t – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our r esistApp. Start Chemical Resistance Check 4.2. Mat erial specifications No. Element Material

1 Nut Steel,

(brass version) S tainless steel 1.4305 PTFE coated

2 Coil Standard:

Polyamide, epoxy Ex version: epoxy 3 Stopper 1.4105 4 Magnet core 1.4105

5 Flange Steel,

(brass version) S tainless steel 1.4301 (stainless steel version)

6 Core seal FKM

7 Seal poppet NBR

8 Poppet Plastic

9 Moulded-in

10 Seal poppet NBR

11 Body Polyamide (reinforced)

12 Silencer Sintered bronze

7 | 14 Visit product website  5. Dimensions 5.1. S tandard version Note: Dimensions in mm 41.3 6.8 32.5

20.5 G1/8

122.6 G1/4 33.5 11.2

8 | 14 Visit product website  5.2. Ex m version Version with 3 m moulded cable Note: Dimensions in mm G1/8 G1/4 33.5 29.7 32.5 6.8 122.6 10.9 6.2 20.5 68.8 min. R25 1 2 Length according to order specification Version with junction box Note: Dimensions in mm 29.7 41.3 84.3 6.8 32.5 R84 Pivot radius M20x1.5 20.5 174.7 G1/8 SW 14 10.9 122.6 G1/4 33.5 99.8

9 | 14 Visit product website  6. P roduct installation 6.1. Mounting options Note: The following figure (right) serves as an example of a block mounting. 7. P roduct accessories 7.1. C able glands for ATEX/IECEx terminal box Note: A cable gland in polyamide version is included in the delivery. A nickel-plated brass version can be ordered at a surcharge. Description Ex approvals Dimensions Certification Identification Ex cable gland, Brass, nickel-plated, 6…13 mm PTB 04 ATEX 1112 X, IECEx PTB 13.0027X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68 TL 29…37 mm L 6 mm D 20 mm SW 24 mm E 27 mm Ex cable gland, Polyamide, 7…13 mm PTB 13 ATEX 1015 X, IECEx PTB 13.0034X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68 TL 36…45 mm L 10 mm D 20 mm SW 24 mm E 28 mm

10 | 14 Visit product website  7.2. Special t ool to turn the junction box Note:

  • This special tool is not supplied with the valve (see “Accessories for ATEX/IECEX terminal box” on page 13).
  • This special tool can only be used with ATEX AC10 coils. Description Components of the set Set SC02-AC10
  • Special wrench
  • Service manual 8. Or dering information 8.1. Bürk ert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and fast delivery You want to find your desired Bürkert product or spare part quickly and order dir ectly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 8.2. Bürk ert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily Try out our product filter

11 | 14 Visit product website  8.3. Or dering chart Standard version with manual override and NBR seal Note:

  • Please note that the cable plug has to be ordered separately, see “Cable plug Type 2513, Form A according to DIN EN 175301 803” on page 13 or separate data sheet Type 2513
  • Please note that the cable plug has to be ordered separately, see “Cable plug Type 2518, Form A according to DIN EN 175301 803” on page 12 or separate data sheet Type 2518
  • To switch a pressure difference of 1 bar is required. NPT connection on request. Circuit function Nominal diameter Port connection QNn value air1.) Pressure range 2.) Power con- sumption Voltage/ Frequency Article no. [mm] [inch] [l/min] [bar] [W] [V/Hz] Type: C, solenoid valve 3/2 way servo-controlled solenoid valve, normally closed 2(A) 1(P) 3(R)

6.0 G ¼ 900 1…10 2 024/DC 134607 

024/50…60 134608  110/50…60 134609  230/50…60 134610  Type: D, solenoid valve 3/2 way servo-controlled solenoid valve, normally open 2(B) 1(P) 3(R)

6.0 G ¼ 900 1…10 2 024/DC 134611 

024/50…60 134612  110/50…60 134613  230/50…60 134614  1.) Flow rate: QNn value air: measurement at + 20 °C, 6 bar pressure at valve inlet, 1 bar pressure difference 2.) Pressure data: overpressure to atmospheric pressure Ex m version with manual override, NBR seal and moulded 3 m cable Note:

  • The maximum medium temperature must not exceed the permissible temperature class (T4: 135 °C, T5: 100 °C, T6: °C) minus K in any case.
  • A pressure difference of 1 bar is required for switching. NPT connection on request. Circuit function Nominal diameter Port connection QNn value air1.) Pressure range 2.) Power con- sumption Voltage/ Frequency Article no. [mm] [inch] [l/min] [bar] [W] [V/Hz] Type: C, solenoid valve 3/2 way servo-controlled solenoid valve, normally closed 2(A) 1(P) 3(R)

6.0 G ¼ 900 1…10 3 024/UC 350432 

Type: D, solenoid valve 3/2 way servo-controlled solenoid valve, normally open 2(B) 1(P) 3(R)

6.0 G ¼ 900 1…10 3 024/UC 350428 

1.) Flow rate: QNn value air: measurement at + 20 °C, 6 bar pressure at valve inlet, 1 bar pressure difference 2.) Pressure data: overpressure to atmospheric pressure

12 | 14 Visit product website  Ex me version with manual override, NBR seal and terminal box Note:

  • The maximum media temperature must not exceed the permissible temperature class (T4: 135 °C, T5: 100 °C, T6: °C) minus K under any circumstances.
  • A pressure difference of 1 bar is required for switching. NPT connection on request.
  • Terminal box without fuse. Circuit function Nominal diameter Port con- nection QNn value air1.) Pressure range 2.) Power con- sumption Voltage/Fre- quency Article no. [mm] [inch] [l/min] [bar] [W] [V/Hz] Type: C, solenoid valve 3/2 way servo-controlled solenoid valve, normally closed 2(A) 1(P) 3(R)

6.0 G ¼ 900 1…10 3 024/UC 350422 

230/UC 350427  Type: D, solenoid valve 3/2 way servo-controlled solenoid valve, normally open 2(B) 1(P) 3(R)

6.0 G ¼ 900 1…10 3 024/UC On request

1.) Flow rate: QNn value air: measurement at + 20 °C, 6 bar pressure at valve inlet, 1 bar pressure difference 2.) Pressure data: overpressure to atmospheric pressure 8.4. Or dering chart accessories Cable plug Type 2518, Form A according to DIN EN 175301 - 803 Not Further versions see data sheet Type 2518 Cable plug Dimensions Version Voltage Article no. ca. 51 35.7 3.5 1.5 29.2 Ø 19 29.2 Without circuitry (AC/DC) 0…250 V A C/DC 314802  With LED (AC/DC) 12…24 V AC/DC 314812  With LED and varistor (AC/DC) 12…24 V AC/DC 314820  With rectifier, LED and varistor 12…24 V AC/DC 314816 

13 | 14Visit product website  Cable plug Type 2513, Form A according to DIN EN 175301 - 803 Not

  • The cable plug Type 2513 meets the requirements of ATEX category GD.
  • For more information on the cable plug, see data sheet Type 2513 Cable plug Circuit diagram Cable length Article no. [mm] BN BU GNYE 12000 260893  5000 260892  3000 260891  300 260890  Single-channel manifold blocks Note: For common pressure port made of aluminium with banjo bolts and seals common balanced pressure port R is possible) Dimensions Manifold Hole spacing A Total length B Article no. [mm] [mm] 2 fold 77 93 005811  3 fold 110 126 005717  4 fold 143 159 005843  5 fold 176 192 005776  6 fold 209 225 005718  Accessories for ATEX/IECEX terminal box Note:
  • A cable gland in polyamide version is included in the delivery. A nickel-plated brass version can be ordered at surcharge.
  • For more information on Ex cable glands, see “7.1. Cable glands for ATEX/IECEx terminal box” on page 9. Description Article no. Ex cable gland, brass, nickel-plated, 6…13 mm1.) 773278  Ex cable gland, polyamide, 7…13 mm1.) 773277  Set SC02-AC10: Special wrench2.) incl. service manual 293488  1.) Cable diameter 2.) Not included in the scope of delivery of the valve

Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa Russia United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -

74653 Künzelsau

www.burkert.com