5077-S2 TIME-ELECTRONICS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Features

  • 0 to 1050 V AC/DC voltage
  • 0 to 22 A AC/DC current
  • Single-phase power simulation
  • Up to 23 kVA or 23 kW
  • Phase angle ± 90.0°
  • Power factor 0.00 to 1.00
  • Adjustable frequency from 40 to 500 Hz
  • 100 A AC current transformer option
  • Single/50-turn current clamp adaptor option
  • RS-232, GPIB, and USB interfaces
  • Calibrator control software included EasyCal Calibration Software The 5077 can be controlled via Time Electronics EasyCal software to automate the calibration process. This provides increased speed of calibration and consistency of results. Produce traceable calibration certificates and test reports for quality standards with additional uncertainty information for ISO 17025 conformance.

5077 Series 2 Multifunction Power Calibrator

Time Electronics Ltd, Unit 5, T O N Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com Technical Specifications (for full technical data see extended specifications sheet) Function Range / Values Best 1 year Specification DC Voltage 0 to ± 1050 V ± 40 ppm of setting DC Current 0 to ± 22 A

1000 A with clamp meter adaptor (option 9780) ± 120 ppm of setting

(simultaneous output of V & I) 23 kW / 23 kVA DCV: 2 mV to 1050 V DCI: 2 mA to 22 A ± 100 ppm of setting ± 150 ppm of setting AC Voltage 2 mV to 1050 V / 20 Hz to 20 kHz sine-wave ± 0.05 % of setting AC Current 10 μA to 22 A / 20 Hz to 5 kHz sine-wave

100 A with current transformer (option 9790)

1000 A with clamp meter adaptor (option 9780)

± 0.07 % of setting AC Power (simultaneous output of V & I) 23 kW / 23 kVA, 40 to 500 Hz ACV: 2 mV to 1050 V ACI: 2 mA to 22 A ± 0.05 % ± 0.1 % Phase ± 90.0°, 40 to 500 Hz ± 0.25° Power Factor 0.00 to 1.00, 40 to 500 Hz Option 9780: Clamp meter adaptor AC/DC Current up to 1000 A (DC, 45 to 90 Hz) ± 0.5 % * The accuracy of the power is complex and is determined by using a formula, which combines the errors due to Voltage, Current, and Phase. Power Accuracy (%) = SqrRt (Voltage Accuracy2 + Current Accuracy2 + Phase Correction2). Where Phase Correction (%) = 100x(1-Cos(Phase+PhaseAcc)/Cos Phase) External Options External Adaptors/Instruments 9780: Clamp meter adaptor (1 and 50 turn coil) • 9790: 100 Amp AC current transformer Accessories 9085: Soft carry case • 9059: Hard transit case • 9728: 19 " Universal rack mount kit • 9796: Premium test lead set EasyCal Software ECFLA: EasyCal full license • 9777: Bar code reader • 9779: Job and address label printer EC2FL/EC2WL: Additional user licenses • EAD: EasyAdmin add-on • CREP: Crystal Reports software General Specifications

Ordering Information

Due to continuous development Time Electronics reserves the right to change specifications without prior notice. v1b