500ACMUP GAPTEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 1 of 6 500ACMUP_S4 – Rev. 2019-1.0 Specifications subject to change without notice. Approval Model1) Power [W] Output voltage [V] Load [A] max. 2) max. convection 3) Ripple&Noise [mV, V1] O/P regulation 4) [%] Efficiency 5) [230VAC, %, typ] UL/CE 500ACMUP_12S4 500 12 30 41.67 120 ±1 >83 UL/CE 500ACMUP_24S4 500 24 15 20.84 240 ±1 >83 UL/CE 500ACMUP_30S4 500 30 12 16.67 300 ±1 >83 UL/CE 500ACMUP_36S4 500 36 10 13.89 360 ±1 >83 UL/CE 500ACMUP_48S4 500 48 7.5 10.42 480 ±1 >83 UL/CE 500ACMUP_54S4 500 54 6.67 9.26 540 ±1 >83 UL/CE 500ACMUP_57S4 500 57 6.32 8.78 570 ±1 >83 1. U= U-channel; Suffix S for End fan, suffix T for Fan on top 2. max output 500W force air 30CFM cooling, Option S and T: max output 500W, +50°C ambient max. 3. max output 270W @ +40°C ambient max. 4. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings 5. Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 10uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector. 500ACMUP_S4 Series 500W - Open Frame Type Switching Power Supply - Universal Input - Isolated & Regulated Universal input: 90~264VAC High efficiency: >83% typical Short circuit protection (SCP) Over load protection (OLP) Over voltage protection (OVP) RoHS compliant Medical 60601-1 3rd Edition approved U-Channel, End fan and Top fan types available AC-DC Converter 500 Watt The 500ACMUP_S4 series is a compact size power converter offered by Gaptec. It features universal input voltage, taking AC input voltage, low power consumption, high efficiency, high reliability, safer isolation. It offers good EMC performance, meets IEC/EN60601-1, UL60601-1 and EN60601-1-2 standards, and is widely used in medical instrumentation and critical applications in commercial and industrial elec-tronic equip - ment. Input specifications Input voltage range 90-264 VAC Input frequency 47~63Hz Power factor 115VAC

  • 0.95(max) 230VAC
  • 0.90 (max) Input current 115VAC
  • 6A (max) 230VAC
  • 3A (max) Inrush current (cold start @25°C) 115VAC
  • <25A peak 230VAC
  • <50A peak Leakage current < 300µA/264VAC Example: 500ACMUP_12S4 500= 500Watt; AC= AC-DC; MUP= series; 12Vout; S= Single Output; 4= 4kVAC Output specifications Item Test conditions Min Typ Max Units Maximum power with 30CFM forced air cooling (U-channel type) 500 W Output voltage accuracy Full load ±2 % Hold-up time @full load, 115VAC 20 ms Current share (single wire) Up to 4 units can be paralleled [Optional] within 10% accuracy at full load DC fan output +12V/1A Note: 1. This product is not designed for use in critical life support systems, equipment used in hazardous environment, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 2. Output connector options: Z=T ( Terminal block type, pitch 8.25mm): Suitable for all voltages Z=C ( Connector type, pitch=3.96mm ): Suitable for 24V up 3. All models are equiped with 5Vsb & 12V fan outputs. 4. All models have total power 250W Max. convection or 360W Max. forced air cooling. 5. Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 10uF elect- rolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector. Protection specifications Short circuit protection Protection type: Auto-recovery Over-voltage protection Protection type: 130% max. above nominal output, shutdown and latch off Over-load protection Protection type: 110% to 150% maximum rating, auto-recovery

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 2 of 6 500ACMUP_S4 – Rev. 2019-1.0 Specifications subject to change without notice. 500ACMUP_S4 Series 500W - Open Frame Type Switching Power Supply - Universal Input - Isolated & Regulated Common specifications Operating temperature range 0°C ~ +70°C (with derating) Storage temperature range -20°C ~ +85°C Humidity (non-condensing) 0-90% MAX Cooling +5VSB/0.25A convection cooling, 1.0A forced air cooling Temperature coefficient ±0.05%/°C I/O-isolation voltage 4000VAC Remote control (Inhibit) function EMC / EMI / Conducted and radiated EMI EN55011 class B (Radiation Class A for 500ACMUP_S4 series) EMC / EMS / ESD IEC/EN 61000-4-2 Contact ±8KV / Air ±15KV perf. Criteria B EMC / EMS / Radiated Immunity IEC/EN 61000-4-3 3V/m perf. Criteria A EMC / EMS / Fast Transient IEC/EN 61000-4-4 ±2kV perf. Criteria B EMC / EMS / Surge IEC/EN 61000-4-5 Line to Line: ±2KV Line to PE: ±4KV perf. Criteria B EMC / EMS / Conducted immunity IEC/EN 61000-4-6 10Vr.m.s perf. Criteria A EMC / EMS / PFMF IEC/EN 61000-4-8 30A/m perf. Criteria A EMC / EMS / Dips IEC/EN 61000-4-11 30% / 500ms perf. Criteria B EMC / EMS / Interruption EN61000-4-11 >95% 5000ms Safety standards UL60601-1 3rd Edition CSA-C22.2 No.60601-1 3rd Edition EN60601-1 3rd Edition EN60601-1 3rd Edition EMC standards EN60601-1-2 EN 55011 Class B FCC Part 18 Class B CE MTBF 100,000 h @25°C ambient temperature, full load Weight 860g / End fan type: 980g / Top fan type: 990g Typical characteristics Derating curve

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 3 of 6 500ACMUP_S4 – Rev. 2019-1.0 Specifications subject to change without notice. 500ACMUP_S4 Series 500W - Open Frame Type Switching Power Supply - Universal Input - Isolated & Regulated Mechanical specifications

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 4 of 6 500ACMUP_S4 – Rev. 2019-1.0 Specifications subject to change without notice. 500ACMUP_S4 Series 500W - Open Frame Type Switching Power Supply - Universal Input - Isolated & Regulated Mechanical dimensions U channel

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 5 of 6 500ACMUP_S4 – Rev. 2019-1.0 Specifications subject to change without notice. 500ACMUP_S4 Series 500W - Open Frame Type Switching Power Supply - Universal Input - Isolated & Regulated Mechanical dimensions End fan type

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 6 of 6 500ACMUP_S4 – Rev. 2019-1.0 Specifications subject to change without notice. 500ACMUP_S4 Series 500W - Open Frame Type Switching Power Supply - Universal Input - Isolated & Regulated Mechanical dimensions Top fan type