GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 1 of 3 45ACDR_S3 – Rev. 2019-1.0 Specifications subject to change without notice. 45ACDR_S3 Series 45W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated Industrial DIN Rail Power Supply High efficiency up to 89% Universal AC input range (90~264VAC) Suitable for critical

applications

Cooling by free air convection Over voltage protection Over current protection Short circuit protection (SCP) 100% full load burn-in test Wide operating ambient temperature (-25°C~70°C) AC-DC Converter 45 Watt The 45ACDR_S3 series features standard rail mounting, energy efficiency and is highly cost-effective. The series offers stability and high noise immunity especially for industrial control equipment, machinery and other demanding environments for industri al equipment. This converter offers a compact and light weight design with and standard rail installati- on (32mm). Furthermore this series offers Easy Fuse Tripping due and a built-in DC OK relay contact. The converter can be installed on TS-35/7.5 or TS-35/15. Example: 45ACDR_24S3 45= 45 Watts AC= AC/DC DR= Din Rail 24= Vout S= Single Output 3= 3000VAC Input specifications Input voltage range 90~264VAC Input frequency 47~63Hz Input current 115VAC

  • 1.1A (max) 230VAC
  • 0.4A (max) Inrush current Cold start 110VAC
  • 15A (max) 230VAC
  • 35A (max) Leakage current Input—output: <0.25mA Input—PE: <3.5mA Output specifications Item Test conditions Min Typ Max Units Load dynamic response Settling time 10ms R/s 1A/us load 25%~75%full load ±5 % Line regulation ±1 % Load regulation ±1 % Set-up time 115VAC/230VAC full load 2 s Rise time The output voltages shall rise from 10% to 90% of their output voltage. 100 ms Hold-up time @115VAC, full load 20 ms Overshoot and undershoot Power on/off ±5 % Switching frequency 100 KHz Note: 1) Oscilloscope should be limited at 20MHZ bandwidth. 2) At output terminals with parallel 0.1uF ceramic and 22uF electrolytic capacitors Protection specifications Over-current protection 110%~150%Io constant current limiting,Reset must be need when Output Limit current to get right. Over-voltage protection 120%~135%Vo Reset must be need when over voltage to get right. The protection time hold-up for 10 seconds or up. Common specifications Short circut protection: Long-term mode, automatic recovery Temperature rise at full load: 40°C MAX Cooling: Free air convection Operation temperature range: -20°C~+70°C (with derating) Storage temperature range: -40°C ~+85°C Storage humidity range: < 95% Temperature coefficient: 0.03%/°C MAX MTBF (using MIL-HDBK-217F): +25°C >200,000 hours Safety standards: Designed to meet the following: UL8750, UL1310-2, EN61347, EN61547 Reliability/Burn-in test: 230VAC (50Hz) input voltage applied to the power supply. Full load is applied on the product in a 40+/-5 degrees Envi- ronment in a burn-in room for 4 hours Case material: Heat-resistant Plastic (UL94-V0) and metal Dimensions: 126*102*34mm (L*W*H) Weight: 0.31kg Isolation specifications Item Test condition Min Typ Max Units Withstand voltage* • Primary-Sec. ≤10mA
  • Primary-PG ≤10mA
  • Secondary-PG ≤10mA 3000 1500 500 VAC Isolation resistance 10 MΩ * Input-Output, tested for 1 minute, 500VDC and leakage current less than 1mA Note: 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 2 of 3 45ACDR_S3 – Rev. 2019-1.0 Specifications subject to change without notice. 45W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated Industrial DIN Rail Power Supply 45ACDR_S3 Series EMC specifications EMC / CE Compliance to EN55015, Class B Conducted emission Test EMC / RE Compliance to EN55015, Class B Radiated emission Test EMC / HARMONIC Compliance to EN61000-3-2 Harmonic current emissions EMC / ESD Compliance to EN61000-4-2 Electrostatic Discharge: 8kV air discharge, 4kV contact discharge EMC / RS Compliance to EN61000-4-3 Radio-Frequency Electromagnetic Field Susceptibility Test-RS EMC / EFT Compliance to EN61000-4-4 Electrical Fast Transient / Burst-EFT±2kV EMC / SURGE Compliance to EN61000-4-5 Surge Immunity Test: AC Power Line: line to line 1 kV, line to earth 2 kV EMC / CS Compliance to EN61000-4-6 Conducted Radio Frequency Disturbances Test-CS EMC / DIP Compliance to EN61000-4-11 Voltage Dips The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. Model Power [W] Output [Vo, VDC] Rated Current [A] Current Range [A] Ripple&Noise* [mV, max] Efficiency [%, typ] 45ACDR_12S3 45 12 3.75 0~3.75 100 85 45ACDR_24S3 45 24 2 0~2 120 87 45ACDR_48S3 45 48 1 0~1 200 89 * Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. Typical characteristics Ambient temperature (°C) Load-ambient derating curve Load (%)

GAPTEC-Electronic GmbH & Co. KG sales@gaptec-electronic.com – www.gaptec-electronic.com Page 3 of 3 45ACDR_S3 – Rev. 2019-1.0 Specifications subject to change without notice. 45W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated Industrial DIN Rail Power Supply 45ACDR_S3 Series Mechanical dimensions 45ACDR_S