Features
- Electro-magnetic tamper resistant coding
- Interfaces directly to a safety relay control unit Specifications Standards EN954-1, ISO13849-1, IEC/EN60204- 1, NFPA79, EN1088, ISO14119, IEC60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 3 per EN954-1 (Sensors with controller) Approvals CE marked for all applicable directives and cULus Power Supply 24V AC/DC or 110/230V AC Power Consumption <6VA X1-X2 Contactor Monitor Loop Normally closed contactor loop Safety Inputs 1 N.O. & 1 N.C. from Ferrocode head Internal Fuse 500 mAT replaceable supply fuse Internal Switches Mains selector switch Relay Output 2 N.O. & 1 N.C. T ÜV approved Specifications (continued) Utilization Category (AC) 4A/250V AC/1000VA at COS ϕ=1 Max Switched DC Current/Volt 2A/30V DC/60W Min Switched DC Current/Volt 10mA/10V Max Output Fuse 5A quick acting Indication Green = Power ON Green = Output closed Max Drop Out Time <50mS Impulse withstand Voltage 2500V Operating T emperature -10°C to +55°C (14°F to 131°F) Contamination Level 3 Humidity 90% RH Degree of Enclosure Protection IP40 DIN 0470 T erminal Isolation IP20 DIN 0470 Max Conductor Size 1 x 2.5mm 2 (14 AWG) stranded with sleeve stripped 8mm,1 x 4mm2 (14AWG) solid conductor T erminals Plus-minus terminal screws M3.5 Box terminal with wire protection Weight 24V DC unit 110/230V unit 314g (0.69lbs) 530g (1.17lbs) Material & Colour Red polycarbonate Housing 16 way D = 120 H = 73 W = 45.5 Installation Group C in accordance with VDE 0110 Fixing Details 35mm DIN rail Switching Head Power Supply 24V DC +/– 15% Power Consumption <1VA Internal Fuse 1A output fuse Safety Distance ON = 7mm, OFF = 9mm Aux. Distance ON = 9mm, OFF = 14mm Outputs 1 N.O. & 1 N.C. Utilization Category (AC) 0.5A/120V AC/60VA at COS ϕ =1 Max Switched DC Current/Volt 1A/28V DC/28W Min Switched DC Current/Volt 10mA/10V Max Output Fuse 1A quick acting Indication LED 1 Green 1 = Guard closed Impulse withstand Voltage 2500V Operating T emperature -10°C to +55°C (14°F to 131°F) Contamination Level 3 Humidity 90% RH Degree of Protection IP67 (NEMA 6P) Weight (not including cable) Switch Actuator 30g (0.07lbs) 40g (0.09lbs) Material & Colour Red moulded ABS plastic Fixing Details M4 Cable 0.2 mm 2 (24AWG) 6 wire; Braided PVC Jacket OD 6mm (0.23in)
Note: Contacts are described with the guard door close, that is, actuator in place. Switch is shipped complete with actuator. Accessories Approximate Dimensions—mm (inches) Dimensions are not intended to be used for installation purposes. Block T ype Supply Voltage Safety Contacts Auxiliary Contacts Connection Housing Catalogue Number Control Unit 24V AC/DC 2 N.O. 1 N.C. T erminals 45mm Wide Polycarbonate 440N-C02068 110V 230V AC 440N-C02070 Switch & Actuator 24V AC/DC 1 N.C. & 1 N.O. None 2m Cable Red, ABS Plastic 440N-C02067 6m Cable 440N-C02078 8m Cable 440N-C02076 10m Cable 440N-C02079 Description Page Number Catalogue Number Actuator — 440N-A02071 Fuse, 500mA 14-6 440R-A31562 Switch Actuator Control Unit 84 (3.31) 54 (2.13) 41 (1.61) (0.16) 7 (0.28) (0.63) (0.43) 4 (0.16) 19 (0.75) 7 (0.28) 4.5 (0.18) 7 (0.28) 4.5 (0.18) 82 (3.23) 73 (2.87) 73 (2.87) 19 (0.75) 4.5 (0.18) 19 (0.75) 45.5 (1.79) 120 (4.72) 35 (1.38) DIN Rail Mounting 73 (2.87) 4.5 (0.18) A2 X2A1 14 24 13 23 31 K2K2 K3K3 VR1 Power Logic Logic Output 24V DC S13 (Black)Red S14 (White) S21 (Green) S22 (Yellow) Blue
Multiple Sensor Input, Manual Reset, Dual-Channel Output, Monitored Output Ferrocode Ground Aux Reset +24V DC Sensor 1 Actuator Sensor 2 Actuator Sensor 3 Actuator S21 X1 S22S14B2 S13B1 X2A2 14 24 13 23 31 K1 K2 M N Single Sensor Input, Automatic Reset, Dual-Channel Output, Monitored Output Ferrocode Aux Sensor 1 Actuator Red Blue Black White Y ellow Green 24V DC Supply Safety N.C. Safety N.O. Note: External Fuse is recommended when switch is not powered by a Ferrocode control unit. Recommend using 24V DC or 110V AC, 300mA fuse.
Typical Application Details Application Details Typical Configurations Typical Applications On presenting the actuator to the switch, the high-intensity electromagnetic field together with a resonant frequency signal causes the contacts to close. On removing the actuator (opening the door) the safety contacts open, isolating the machine. The switch can not be overridden by magnets, tools, etc. Safety contact operating distance: make 7mm, break 9mm Auxiliary contact operating distance: make 9mm, break 14mm On hinged doors, install switch at the opening edge. Where 2 switches are mounted adjacent, they should be no closer than 25mm. Recommend a 2mm spacing between switch and actuator. >25mm Switch Switch Actuator Actuator Actuator Spacing Actuator Approach Directions Wigan WN2 4HR 0942 55166 Actuator Made in England Ferrocode Wigan WN2 4HR 0942 55166 Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 Made in England Ferrocode TAMPER PROOF SAFETY SYSTEM Made in the EC FERROCODE pr EN 1088 EN 60204 pt.1 ISOLATE BEFORE REMOVING COVER! A1 A2 X1 X2 B1 B2 S13 S14 SEE SIDE FOR SUPPLY SUPPLY Red Blue Black White Control Unit 31 32 13 14 23 24 S21S22 AUXILIARY SAFETY 1 SAFETY 2 Green Yellow POWER OUTPUT Wigan WN2 4HR 0942 55166 Made in England Ferrocode Wigan WN2 4HR 0942 55166 Made in England Ferrocode Wigan WN2 4HR 0942 55166 Made in England Ferrocode Wigan WN2 4HR 0942 55166 Made in England Ferrocode Wigan WN2 4HR 0942 55166 Made in England Ferrocode Wigan WN2 4HR 0942 55166 Made in England Ferrocode Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 TAMPER PROOF SAFETY SYSTEM Made in the EC FERROCODE pr EN 1088 EN 60204 pt.1 ISOLATE BEFORE REMOVING COVER! SEE SIDE FOR SUPPLY SUPPLY Red Blue Black White Control Unit 31 32 13 14 23 24 S21S22 AUXILIARY SAFETY 1 SAFETY 2 Green Yellow POWER OUTPUT Wigan WN2 4HR 0942 55166 Actuator Made in England Ferrocode Wigan WN2 4HR 0942 55166 Made in England Ferrocode Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 A1 A2 X1 X2 B1 B2 S13 S14 The Ferrocode switch can be used without a control unit for low risk/low power applications. Six Ferrocode switches can be used with one control unit for high risk applications. Connect the N.C. contacts (black and white wires) in series and the N.O. contacts (green and yellow wires) in parallel. One Ferrocode switch used with a control unit provides a higher integrity system. Note: Removable guards using Non contact switches may require two switches, one at either side of the guard, or the use of a flap to prevent initial lifting of the non-interlocked edge. Sliding Guard Hinged Guard Removable Guard