440G-S36001 ALLEN-BRADLEY | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Features
- P o w e r t o r e l e a s e
- Lid mounted status indication
- High locking force—1200N (270lbs.)
- Rotatable head: 4 possible key entry slotsTypical Applications Note: Lift-off guards require good alignment when using tongue actuated interlock switches. IMPORTANT: It must not be possible to lift the guard without actuating the interlock. An interlock on either side may be required. Specifications ➊ Conductive pollution occurs, or dry, non conductive pollution occurs which becomes conductive due to condensation. Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems Approvals CE marked for all applicable directives, cULus and TUV Nord Safety Contact 2 N.C. or 3 N.C. direct opening action Utilization Cat. AC (Ue) (le) DC AC 15 500V 250V 100V 1A 2A 5A 250V/0.5A 24V/2A Maximum Switched Current/ Volt/Load 500V/500VA Thermal Current (lth) 10A Min Current 5V 5mA DC Safety Contact Gap >2mm Rtd. Insulation Voltage 500V Rtd. Impulse withstand Volt 2500V Auxiliary Contacts 1 N.O. Pollution Degree ➊ 3 Max Actuation Speed 160mm/second (6.3 in/sec) Max Actuation Frequency 1 cycle/second Case Material UL Approved glass filled polyester Actuator Material Stainless steel Protection IP 67 Conduit Entry 1 x M20 or quick disconnect style Operating T emperature -20°C to 60°C (-4°F to +140°F) Fixing 2 x M5 Mounting Any position Mechanical Life 1,000,000 operations Electrical Life 1,000,000 operations Weight 260g (0.57 lb) Colour Red Max Holding Force 1200N (270lbs) Min Operating Radius 175mm (6.9in) LED Indication Solenoid monitor LED Power Supply 24V AC/DC, 110V AC, 230V AC (solenoid) Solenoid Power Typically 7W 100% ED
Safety Aux. M20 Conduit M20 Conduit/ 1/2in Adaptor Quick Disconnect Standard
24 V AC/DC
2 N.C. 1 N.O. 440G-S36001 440G-S36044 440G-S36058 3 N.C. — 440G-S36007 440G-S36047 440G-S36059
110 V AC/DC
2 N.C. 1 N.O. 440G-S36003 440G-S36045 440G-S36060 3 N.C. -- 440G-S36009 440G-S36048 440G-S36061 230V AC/DC 2 N.C. 1 N.O. 440G-S36005 440G-S36046 440G-S36062 3 N.C. — 440G-S36011 440G-S36049 440G-S36063 Mating cable 2m (6.5ft). See page 15-13 for details and additional lengths. 889M-F12X9AE-2 Description For Dimensions refer to page Catalogue Number Replacement Actuator with Catch Retainer and Guide 14-4 440G-A36050 Emergency Override 14-4 440G-A36026
Approximate Dimensions—mm (inches) Dimensions are not intended to be used for installation purposes. Typical Wiring Diagrams Connector Pinout T erminal Contact T erminal Contact 1A 1 Solenoid Power A1 Solenoid Power3A 2 A 2 41 1 N.C. 11 N.C.61 2 1 2 72 1 N.C. 21 N.C.82 2 2 2 93 3 N.O. 31 N.C.10 34 32
12 Ground
14.5 (0.57) 120 (4.72) Conduit Entry (M20) Emergency Release Points 35 (1.38) 31 (1.22) 40 (1.57) 9 (0.35) 14 (0.55) 37 (1.46) 12 (0.47) 8 (0.31) 7 (0.28) 5 (0.2) 5.5 (0.22) 58 (2.28) 52 (2.05) 40 (1.57) Key Ø5.5 (0.22) (0.3) 34.5 (1.36) 20.5 (0.81) 22 34 33 12 11 A2 A1 32 31 12 11 21 22 21 A2 A1 Auxiliary Circuit Safety Circuit 2 Safety Circuit 1 AC/DC Solenoid Power Safety Circuit 3 Safety Circuit 2 Safety Circuit 1 AC/DC Solenoid Power Solenoid AC/DC 100% ED. Solenoid AC/DC 100% ED. 210 36 11 2 N.C. + 1 N.O. 12 0mm Contact Open Contact Closed Actuator withdrawal distance from full insertion Contact Action 2.5 3 N.C. 12 0mm 6 2.5
4 possible actuator entry positions Locking Force = ≤1200N