Features
- Mechanical lock
- High locking force—5500N (1236lbs.)
- Heavy duty die-cast alloy housing ideal for harsh environments
- Patented self-aligning head tolerates actuator misalignment Specifications Standards EN954-1, ISO13849-1, IEC/EN60204- 1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems Approvals CE marked for all applicable directives, cULus and CSA Safety Contacts Atlas 5 Atlas 5 trapped key (left hand) 2 N.C. direct opening action 1 N.O. direct opening action 2 N.C. direct opening action 1 N.O. direct opening action Utilization Cat. AC (Ue) (le) DC AC 15 500V 250V 100V 1A 2A 5A 250V 0.5A, 24V 2A Maximum Switched Current/ Volt/Load 500V 500VA Thermal Current (lth) 10A Min Current 5V . 5mA DC Safety Contact Gap > 2mm contact block Rtd. Insulation Voltage (Ui) 500V Rtd. Impulse withstand Volt (Uimp) 2500V Auxiliary Contacts 1 N.O. Actuator Travel for Positive Opening 8mm (.31in.) Break Contact Min Force 12N (2.7 lbs) Max Actuation Speed 160mm per sec (6.3 in. per sec) Max Actuation Frequency 2 Cycle per sec Case Material Die cast alloy Actuator Material Stainless Steel Protection IP65 Conduit Entry 3 x M20 or 3 x 1/2in NPT or quick disconnect Operating T emperature -10°C to +60°C (14°F to +140°F) Fixing 4 x M5 Mechanical Life 1,000,000 operations Electrical Life 1,000,000 operations Weight 1200g (2.65lbs) Colour Red Max Holding Force 5500N (1236lbs) Min Operating Radius 300mm end entry, 800mm entry front Power Supply 24V AC/DC or 110V AC or 230V AC (solenoid) Solenoid Power 13W typical 100% ED Solenoid Rating 100% duty
Safety Aux. M20 Conduit 1/2in NPT Quick Disconnect Atlas 5 Standard Standard 2 N.C. 1 N.O. 24V AC/DC 440G-L07264 440G-L07258 440G-L07298 110V AC/DC 440G-L07263 440G-L07257 440G-L07299 230V AC/DC 440G-L07262 440G-L07256 440G-L07300 LH Key Lock 24V AC/DC 440G-L07255 440G-L07249 440G-L07301 110V AC/DC 440G-L07254 440G-L07248 440G-L07302 230V AC/DC 440G-L07253 440G-L07247 440G-L07303 M23 mating cable 2m (6.5ft). See page 15-13 for details and additional lengths. 889M-F12AH-2 Description For Dimensions refer to page Catalogue Number Standard Actuator 14-3 440G-A07136 Replacement End Cap 14-3 440G-A07180 Fully Flex Actuator 14-3 440G-A07269
Approximate Dimensions—mm (inches) Dimensions are not intended to be used for installation purposes. Typical Wiring Diagrams Connector Pinout T erminal Contact 1A 1 Solenoid Power3A 2 45 N.C.66 77 N.C.88 91 N.O.10 2 53 N.O.24
12 Ground
(0.47) 56 (2.2) (0.91) (0.2) (0.39) (0.91) 52 (2) Ctrs 4 X M5 56 (2.2) R Min 800 (31.5)
2 Manual Lock
(0.67) (1.18) Lock Unlock 163 (6.4) Ctrs 184 (7.24)5 (0.2) 13 (0.51) 43 (1.69) 12 (0.47)25 (0.98) 16 (0.63) 80 (3.15) LH Key Lock style Only 16 (0.63) 95 (3.74) (0.2) (0.98) 56 (2.2) Front Entry Actuator Hole R Min 300 (11.8) (0.55) 90 (3.54) A2A12345 678 E 2211 A2A1 432 Aux Guard Open— Solenoid De-energized Aux Safety SafetyAC/DC Solenoid Supply T erminal Configuration Machine in Run Condition AC/DC 100% ED. Lid Illumination Only 20 12 0mm Contact Open Contact Closed Actuator withdrawal distance from full insertion Contact Action 19 13.5 210 36 11
Used with Atlas for machines with constant overruns. Gives a timed delay to the lock/release signal. Failsafe and adjustable to a range of times from 0.1 seconds up to 40 minutes. For more details, see the Safety monitoring relay section in this catalogue. CU 2 Stop Motion Detector Unit Used with Atlas for machines with constant or variable over run. Gives a timed delay to the lock/release signal. Fail safe and adjustable to a range of times from 0.1 seconds up to 40 minutes. For more details, see the Monitoring Safety Relay section in this catalogue. Minotaur MSR6R/T Monitoring Safety Relay Unit Ensures a maximum level of safety by monitoring all wiring in the safety circuit including switches and contactors. Any fault and the power to the machine is switched off. Other Minotaur units are available, see the Safety monitoring relay section in this catalogue.